Hrvoje Šobat
Hrvoje Šobat has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Adlan Čehobašić
Specijalna bolnica Radiochirurgia Zagreb, Ulica Dr. Franje Tuđmana 4, 10431 Sveta Nedelja, Croatia
2 shared publications - Andreas Mack
Swiss NeuroRadiosurgery Center, Bürglistrasse 29, 8002 Zürich, Switzerland
2 shared publications - Domagoj Kosmina
Specialty Hospital Radiochirurgia Zagreb, 10431 Sveta Nedelja, Croatia
2 shared publications - Dragan Schwarz
Specialty Hospital Radiochirurgia Zagreb, 10431 Sveta Nedelja, Croatia
2 shared publications - Hrvoje Kaučić
Specialty Hospital Radiochirurgia Zagreb, 10431 Sveta Nedelja, Croatia
2 shared publications - Mihaela Mlinarić
Specialty Hospital Radiochirurgia Zagreb, 10431 Sveta Nedelja, Croatia
2 shared publications
Latest Publications
- Open Access
Stereotactic Ablative Radiotherapy Using CALYPSO® Extracranial Tracking for Intrafractional Tumor Motion Management—A New Potential Local Treatment for Unresectable Locally Advanced Pancreatic Cancer? Results from a Retrospective Study
(1) Background: The aim of this study was to evaluate the efficacy and safety of SABR for LAPC using Calypso® Extracranial Tracking for intrafractional, fiducial-based motion management, to present this motion management technique, as there are yet no published data on usage of Calypso® during SABR for LAPC, and to report on our clinical outcomes. (2) Methods: Fifty-four patients were treated with SABR in one, three, or five fractions, receiving median BED10 = 112.5 Gy. Thirty-eight patients received systemic treatment. End points were OS, FFLP, PFS, and toxicity. Actuarial survival analysis and univariate analysis were investigated. (3) Results: Median follow-up was 20 months. Median OS was 24 months. One-year FFLP and one-year OS were 100% and 90.7%, respectively. Median PFS was 18 months, and one-year PFS was 72.2%. Twenty-five patients (46.3%) were alive at the time of analysis, and both median FU and OS for this subgroup were 26 months. No acute/late toxicity > G2 was reported. (4) Conclusions: SABR for LAPC using Calypso® presented as an effective and safe treatment and could be a promising local therapeutic option with very acceptable toxicity, either as a single treatment or in a multimodality regimen. Dose escalation to the tumor combined with systemic treatment could yield better clinical outcomes.
Open AccessStereotactic Ablative Radiotherapy Using CALYPSO® Extracranial Tracking for Intrafractional Tumor Motion Management—A New Potential Local Treatment for Unresectable Locally Advanced Pancreatic Cancer? Results from a Retrospective Study
(1) Background: The aim of this study was to evaluate the efficacy and safety of SABR for LAPC using Calypso® Extracranial Tracking for intrafractional, fiducial-based motion management, to present this motion management technique, as there are yet no published data on usage of Calypso® during SABR for LAPC, and to report on our clinical outcomes. (2) Methods: Fifty-four patients were treated with SABR in one, three, or five fractions, receiving median BED10 = 112.5 Gy. Thirty-eight patients received systemic treatment. End points were OS, FFLP, PFS, and toxicity. Actuarial survival analysis and univariate analysis were investigated. (3) Results: Median follow-up was 20 months. Median OS was 24 months. One-year FFLP and one-year OS were 100% and 90.7%, respectively. Median PFS was 18 months, and one-year PFS was 72.2%. Twenty-five patients (46.3%) were alive at the time of analysis, and both median FU and OS for this subgroup were 26 months. No acute/late toxicity > G2 was reported. (4) Conclusions: SABR for LAPC using Calypso® presented as an effective and safe treatment and could be a promising local therapeutic option with very acceptable toxicity, either as a single treatment or in a multimodality regimen. Dose escalation to the tumor combined with systemic treatment could yield better clinical outcomes.
- Open Access
- 11 November 2021
- Published by MDPI AG in Current Oncology
- Vol. 28 (6) , 4597-4610
An Evaluation of Total Internal Motions of Locally Advanced Pancreatic Cancer during SABR Using Calypso® Extracranial Tracking, and Its Possible Clinical Impact on Motion Management
(1) Background: the aims of this study were to determine the total extent of pancreatic cancer’s internal motions, using Calypso® extracranial tracking, and to indicate possible clinical advantages of continuous intrafractional fiducial-based tumor motion tracking during SABR. (2) Methods: thirty-four patients were treated with SABR for LAPC using Calypso® for motion management. Planning MSCTs in FB and DBH, and 4D-CTs were performed. Using data from Calypso® and 4D-CTs, the movements of the lesions in the CC, AP and LR directions, as well as the volumes of the 4D-CT-based ITV and the volumes of the Calypso®-based ITV were compared. (3) Results: significantly larger medians of tumor excursions were found with Calypso® than with 4D-CT: CC: 29 mm (p < 0.001); AP: 14 mm (p < 0.001) and LR: 11 mm (p < 0.039). The median volume of the Calypso®-based ITV was significantly larger than that of the 4D-CT based ITV (p < 0.001). (4) Conclusion: beside known respiratory-induced internal motions, pancreatic cancer seems to have significant additional motions which should be considered during respiratory motion management. Only direct and continuous intrafractional fiducial-based motion tracking seems to provide complete coverage of the target lesion with the prescribed isodose, which could allow for safe tumor dose escalation.
- 11 November 2021
- Published by MDPI AG in Current Oncology
- Vol. 28 (6) , 4597-4610
Open AccessAn Evaluation of Total Internal Motions of Locally Advanced Pancreatic Cancer during SABR Using Calypso® Extracranial Tracking, and Its Possible Clinical Impact on Motion Management
(1) Background: the aims of this study were to determine the total extent of pancreatic cancer’s internal motions, using Calypso® extracranial tracking, and to indicate possible clinical advantages of continuous intrafractional fiducial-based tumor motion tracking during SABR. (2) Methods: thirty-four patients were treated with SABR for LAPC using Calypso® for motion management. Planning MSCTs in FB and DBH, and 4D-CTs were performed. Using data from Calypso® and 4D-CTs, the movements of the lesions in the CC, AP and LR directions, as well as the volumes of the 4D-CT-based ITV and the volumes of the Calypso®-based ITV were compared. (3) Results: significantly larger medians of tumor excursions were found with Calypso® than with 4D-CT: CC: 29 mm (p < 0.001); AP: 14 mm (p < 0.001) and LR: 11 mm (p < 0.039). The median volume of the Calypso®-based ITV was significantly larger than that of the 4D-CT based ITV (p < 0.001). (4) Conclusion: beside known respiratory-induced internal motions, pancreatic cancer seems to have significant additional motions which should be considered during respiratory motion management. Only direct and continuous intrafractional fiducial-based motion tracking seems to provide complete coverage of the target lesion with the prescribed isodose, which could allow for safe tumor dose escalation.