LSLifang Shen

Lifang Shen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Lifang Shen has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Study on the Effect of Electron/Hole Injection on the Energy-Storage Properties of Polymer Dielectrics

    by Guang Liu, Yuhao Chen, Yang Cui, Lifang Shen, Taiquan Wu, Chen Chen, Yunxia Luo, Shubin Yan

    As a critical component of electrostatic capacitors, the polymer dielectric directly affects the performance of the capacitor. In this work, Polycarbonate (PC)/Polyvinylidene fluoride (PVDF) asymmetric bilayer polymer dielectrics were prepared, and the influence of different polymer materials’ barrier characteristics on various electrical properties of composite dielectrics was studied by changing the direction of applied electric fields. Research has found that the dielectric constant of a composite dielectric is between PVDF and PC (approximately 4.8 at 10 Hz) and is independent of the relative position of PVDF and PC in the dielectric. However, the relative position of PC and PVDF has a significant impact on the energy-storage characteristics of composite dielectrics. When PVDF comes into contact with the negative electrode, even though PC has a higher hole barrier, the composite dielectric can only withstand a maximum electric-field strength of 400 MV/m, which is much lower than the maximum electric-field strength that pure PC can withstand (520 MV/m), and it only achieves an energy-storage density of 3.7 J/cm3. When the PC comes into contact with the negative electrode, the high electron barrier of the PC effectively suppresses the injection of electrons at the electrode. It can withstand the same electric-field strength as PC (520 MV/m), achieving an energy-storage density of 5.48 J/cm3, which is 1.46 times that of pure PC and 1.64 times that of PVDF. This experiment effectively combined the advantages of PC and PVDF by utilizing the electron/hole barrier of polymer materials to obtain a fully organic dielectric with excellent energy-storage performance.


  • Open Access

    Improved Energy Storage Performance of Composite Films Based on Linear/Ferroelectric Polarization Characteristics

    by Chen Chen, Lifang Shen, Guang Liu, Yang Cui, Shubin Yan

    The development and integration of high-performance electronic devices are critical in advancing energy storage with dielectric capacitors. Poly(vinylidene fluoride-trifluoroethylene-chlorofluoroethylene) (PVTC), as an energy storage polymer, exhibits high-intensity polarization in low electric strength fields. However, a hysteresis effect can result in significant residual polarization, leading to a severe energy loss, which impacts the resultant energy storage density and charge/discharge efficiency. In order to modify the polarization properties of the polymer, a biaxially oriented polypropylene (BOPP) film with linear characteristics has been selected as an insulating layer and combined with the PVTC ferroelectric polarization layer to construct PVTC/BOPP bilayer films. The hetero-structure and polarization characteristics of the bilayer film have been systematically studied. Adjusting the BOPP volume content to 67% resulted in a discharge energy density of 10.1 J/cm3 and an energy storage efficiency of 80.9%. The results of this study have established the mechanism for a composite structure regulation of macroscopic energy storage performance. These findings can provide a basis for the effective application of ferroelectric polymer-based composites in dielectric energy storage.


  • Open Access

    Nanoscale Refractive Index Sensors Based on Fano Resonance Phenomena

    by Yifeng Ren, Qiang Wang, Lifang Shen, Feng Liu, Yang Cui, Chuanhui Zhu, Zhanbo Chen, Biyi Huang, Shubin Yan

    In this paper, a new refractive index sensor based on Fano resonance is introduced. It is mainly composed of two parts: a metal–insulator–metal as a base waveguide and an annular resonant cavity with a double notch and a double convex circle as a coupling structure. The sensing characteristics of the design are investigated via finite element calculations. The influence of the remaining structure parameters on the system’s sensing performance and the relationship between the wavelength corresponding to the Fano trough and the refractive index are also investigated. Furthermore, the structure is applied to refractive index sensors, resulting in a type with a sensitivity of 2740 nm/RIU and a figure of merit of 52.69.


  • Open Access

    A Nano Refractive Index Sensing Structure for Monitoring Hemoglobin Concentration in Human Body

    by Guoquan Zhou, Shubin Yan, Lili Chen, Xiaoyu Zhang, Lifang Shen, Pengwei Liu, Yang Cui, Jilai Liu, Tingsong Li, Yifeng Ren

    This paper proposes a nanosensor structure consisting of a metal–insulator–metal (MIM) waveguide with a rectangular root and a double-ring (SRRDR) with a rectangular cavity. In this paper, the cause and internal mechanism of Fano resonance are investigated by the finite element method (FEM), and the transport characteristics are optimized by changing various parameters of the structure. The results show that the structure can achieve double Fano resonance. Due to the destructive disturbance between the wideband mode of the inverted rectangle on the bus waveguide and the narrowband mode of the SRRDR, the output spectrum of the system shows an obvious asymmetric Fano diagram, and the structural parameters of the sensor have a great influence on the Fano resonance. By changing the sensitive parameters, the optimal sensitivity of the refractive index nanosensor is 2280 nm/RIU, and the coefficient of excellence (FOM) is 76.7. In addition, the proposed high-sensitivity nanosensor will be used to detect hemoglobin concentration in blood, which has positive applications for biosensors and has great potential for future nanosensing and optical integration systems.


  • Open Access

    Refractive Index and Alcohol-Concentration Sensor Based on Fano Phenomenon

    by Qiang Wang, Shubin Yan, Jilai Liu, Xiaoyu Zhang, Lifang Shen, Pengwei Liu, Yang Cui, Tingsong Li, Yifeng Ren

    A novel nano-refractive index sensor based on the Fano resonance phenomenon is proposed in this paper. The sensor consists of the metal-insulator-metal (MIM) waveguide and a V-ring cavity with a groove (VRCG). We analyzed the performance of the nanoscale sensor using the finite element method. The simulation results show that the asymmetry of the geometric structure itself is the main factor leading to Fano resonance splitting. In Fano splitting mode, the Fano bandwidth of the system can be significantly reduced when the sensor sensitivity is slightly reduced, so that the figure of merit (FOM) of the sensor can be substantially improved. Based on the above advantages, the sensor’s sensitivity in this paper is as high as 2765 nm/RIU, FOM = 50.28. In addition, we further applied the sensor to alcohol concentration detection. The effect is good, and the sensitivity achieves about 150. This type of sensor has a bright future in the precision measurement of solution concentrations.


  • Open Access

    Novel Nanoscale Refractive Index Sensor Based on Fano Resonance

    by Shubin Yan, Qiang Wang, Lifang Shen, Feng Liu, Yiru Su, Yi Zhang, Yang Cui, Guoquan Zhou, Jilai Liu, Yifeng Ren

    This paper proposes a novel nano-sized refractive index sensor based on the Fano resonance phenomenon. The main structure consists of two short tubes of the metal-insulation-metal waveguide and an internal Z-ring resonator. The authors used a finite element approach to analyze the nanoscale sensing performance of the system. Simulation results show that asymmetries in the geometry will lead to Fano resonance splitting. This paper explicitly explores whether the structure’s top and bottom asymmetry is a significant factor in the Fano resonance of the internal Z-ring resonator structure. After Fano resonance splitting, the obtained transmission curve was sharper, the bandwidth was significantly reduced, and the system’s figure of merit was significantly improved. This paper further extends the internal Z-ring resonator structure to the sensor field. The resulting refractive index sensor has a sensitivity of 2234 nm/RIU and a figure of merit of 49.65.


  • Open Access

    A Nanoscale Sensor Based on a Toroidal Cavity with a Built-In Elliptical Ring Structure for Temperature Sensing Application

    by Feng Liu, Shubin Yan, Lifang Shen, Pengwei Liu, Lili Chen, Xiaoyu Zhang, Guang Liu, Jilai Liu, Tingsong Li, Yifeng Ren

    In this article, a refractive index sensor based on Fano resonance, which is generated by the coupling of a metal–insulator–metal (MIM) waveguide structure and a toroidal cavity with a built-in elliptical ring (TCER) structure, is presented. The finite element method (FEM) was employed to analyze the propagation characteristics of the integral structure. The effects of refractive index and different geometric parameters of the structure on the sensing characteristics were evaluated. The maximum sensitivity was 2220 nm/RIU with a figure of merit (FOM) of 58.7, which is the best performance level that the designed structure could achieve. Moreover, due to its high sensitivity and simple structure, the refractive index sensor can be applied in the field of temperature detection, and its sensitivity is calculated to be 1.187 nm/℃.


  • Open Access

    Multiwalled Carbon Nanotube/Graphite Powder Film for Wearable Pressure Sensors with High Sensing Performance

    by Shubin Yan, Xiaoyu Zhang, Jilai Liu, Haoqian Xu, Feng Wen, Tingsong Li, Jiamin Cui, Pengwei Liu, Lifang Shen, Yang Cui, et al.

    With the continuous progress of artificial intelligence and other manufacturing technologies, there is promising potential for wearable piezoresistive sensors in human physiological signal detection and bionic robots. Here, we present a facile solution-mixing process to fabricate a multiwalled carbon nanotube/graphite powder (MWCNT@Gp) film, which has high sensitivity and great linearity and is more oriented to flexible piezoresistive sensors. The sensor consists of two parts: a spinosum microstructure shaped by a sandpaper template and polydimethylsiloxane (PDMS) as the top substrate and interdigital electrodes as the bottom substrate. The experiments we have conducted show that these two parts provide good protection to the MWCNTs@Gp film and improve sensor sensitivity. Additionally, the sensitivity of the optimal ratio of multiwalled carbon nanotubes and graphite powder is analyzed. The 5%MWCNT@5%Gp composites were found to have relatively good conductivity, which is convenient for the fabrication of conductive films of piezoresistive sensors. Finally, we conducted application experiments and found that the flexible piezoresistive sensor can detect minute signals of human motion and different pressure points. This indicates the feasibility of portable sensors in electronic skin and smart devices.


  • Open Access

    High-Property Refractive Index and Bio-Sensing Dual-Purpose Sensor Based on SPPs

    by Shubin Yan, Pengwei Liu, Zhanbo Chen, Jilai Liu, Lifang Shen, Xiaoyu Zhang, Jiaming Cui, Tingsong Li, Yang Cui, Yifeng Ren

    A high-property plasma resonance-sensor structure consisting of two metal-insulator-metal (MIM) waveguides coupled with a transverse ladder-shaped nano-cavity (TLSNC) is designed based on surface plasmon polaritons. Its transmission characteristics are analyzed using multimode interference coupling mode theory (MICMT), and are simulated using finite element analysis (FEA). Meanwhile, the influence of different structural arguments on the performance of the structure is investigated. This study shows that the system presents four high-quality formants in the transmission spectrum. The highest sensitivity is 3000 nm/RIU with a high FOM* of 9.7 × 105. In addition, the proposed structure could act as a biosensor to detect the concentrations of sodium ions (Na+), potassium ions (K+), and the glucose solution with maximum sensitivities of 0.45, 0.625 and 5.5 nm/mgdL−1, respectively. Compared with other structures, the designed system has the advantages of a simple construction, a wide working band range, high reliability and easy nano-scale integration, providing a high-performance cavity choice for refractive index sensing and biosensing devices based on surface plasmons.


  • Open Access

    Refractive Index Sensor Based on a Metal-Insulator-Metal Bus Waveguide Coupled with a U-Shaped Ring Resonator

    by Xiaoyu Zhang, Shubin Yan, Jilai Liu, Yifeng Ren, Yi Zhang, Lifang Shen

    In this study, a novel refractive index sensor structure was designed consisting of a metal-insulator-metal (MIM) waveguide with two rectangular baffles and a U-Shaped Ring Resonator (USRR). The finite element method was used to theoretically investigate the sensor’s transmission characteristics. The simulation results show that Fano resonance is a sharp asymmetric resonance generated by the interaction between the discrete narrow-band mode and the successive wide-band mode. Next, the formation of broadband and narrowband is further studied, and finally the key factors affecting the performance of the sensor are obtained. The best sensitivity of this refractive-index sensor is 2020 nm/RIU and the figure of merit (FOM) is 53.16. The presented sensor has the potential to be useful in nanophotonic sensing applications.