Gideon Shafir
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Gideon Shafir has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Arthur Shiyovich
Heart and Vascular Institute, Brigham and Women’s Hospital, Boston, MA 02115, USA
2 shared publications Hana Vaknin Assa
Department of Cardiology, Rabin Medical Center , 39 Jabotinsky Street, Petach Tikva 49414 , Israel
2 shared publications- Yaron Aviv
Rabin Medical Centre
2 shared publications - Ygal Plakht
Faculty of Health Sciences, Ben-Gurion University of the Negev, Beer Sheva 8410501, Israel
2 shared publications - Alon Barsheshet
Department of Cardiology, Rabin Medical Center, Petah-Tikva and The Gray Faculty of Medical and Health sciences, Tel Aviv University, Tel Aviv, Israel
1 shared publication Ashraf Hamdan
Department of Cardiology
1 shared publication
Latest Publications
- Open Access
- 1 May 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (5)
Interventricular septal thickness on cardiac computed tomography as a novel risk factor for conduction disturbances in patients undergoing transcatheter aortic valve replacement
We examined whether thickness of the basal muscular interventricular septum (IVS), as measured by pre-procedural computed tomography (CT), could be used to identify the risk of conduction disturbances following transcatheter aortic valve replacement (TAVR). The IVS is a pivotal region of the electrical conduction system of the heart where the atrioventricular conduction axis is located. Included were 78 patients with severe aortic stenosis who underwent CT imaging prior to TAVR. The thickness of muscular IVS was measured in the coronal view, in systolic phases, at 1, 2, 5, and 10 mm below the membranous septum (MS). The primary endpoint was a composite of conduction disturbance following TAVR. Conduction disturbances occurred in 24 out of 78 patients (30.8%). Those with conduction disturbances were significantly more likely to have a thinner IVS than those without conduction disturbances at every measured IVS level (2.98 ± 0.52 mm vs. 3.38 ± 0.52 mm, 4.10 ± 1.02 mm vs. 4.65 ± 0.78 mm, 6.11 ± 1.12 mm vs. 6.88 ± 1.03 mm, and 9.72 ± 1.95 mm vs. 10.70 ± 1.55 mm for 1, 2, 5 and 10 mm below MS, respectively, P < 0.05 for all). Multivariable logistic regression analysis showed that pre-procedural IVS thickness (P = 0.003). Pre-procedural CT assessment of basal IVS thickness is a novel predictive marker for the risk of conduction disturbances following TAVR. The IVS thickness potentially acts as an anatomical barrier protecting the underlying conduction system from mechanical compression during TAVR.
- 1 May 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (5)
Open AccessInterventricular septal thickness on cardiac computed tomography as a novel risk factor for conduction disturbances in patients undergoing transcatheter aortic valve replacement
We examined whether thickness of the basal muscular interventricular septum (IVS), as measured by pre-procedural computed tomography (CT), could be used to identify the risk of conduction disturbances following transcatheter aortic valve replacement (TAVR). The IVS is a pivotal region of the electrical conduction system of the heart where the atrioventricular conduction axis is located. Included were 78 patients with severe aortic stenosis who underwent CT imaging prior to TAVR. The thickness of muscular IVS was measured in the coronal view, in systolic phases, at 1, 2, 5, and 10 mm below the membranous septum (MS). The primary endpoint was a composite of conduction disturbance following TAVR. Conduction disturbances occurred in 24 out of 78 patients (30.8%). Those with conduction disturbances were significantly more likely to have a thinner IVS than those without conduction disturbances at every measured IVS level (2.98 ± 0.52 mm vs. 3.38 ± 0.52 mm, 4.10 ± 1.02 mm vs. 4.65 ± 0.78 mm, 6.11 ± 1.12 mm vs. 6.88 ± 1.03 mm, and 9.72 ± 1.95 mm vs. 10.70 ± 1.55 mm for 1, 2, 5 and 10 mm below MS, respectively, P < 0.05 for all). Multivariable logistic regression analysis showed that pre-procedural IVS thickness (P = 0.003). Pre-procedural CT assessment of basal IVS thickness is a novel predictive marker for the risk of conduction disturbances following TAVR. The IVS thickness potentially acts as an anatomical barrier protecting the underlying conduction system from mechanical compression during TAVR.
- 1 January 2022
- Published by Elsevier in The American Journal of Cardiology
- Vol. 163, 71-76
Relation of Serum Albumin Levels to Myocardial Extracellular Volume in Patients With Severe Aortic Stenosis
- 1 January 2022
- Published by Elsevier in The American Journal of Cardiology
- Vol. 163, 71-76
Relation of Serum Albumin Levels to Myocardial Extracellular Volume in Patients With Severe Aortic Stenosis