MAMohamed Abdelkawy

Mohamed Abdelkawy

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mohamed Abdelkawy has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Green Electrochemical Sensing: Novel Ion-Selective Electrode Method for Precise Determination of Dimenhydrinate and its Metabolite along with Cinnarizine in Pharmaceutical and Plasma Samples

    by Shereen A. Boltia, Eman M. Morgan, Reem H. Obaydo, Yasmin M. Fayez, M. Abdelkawy, Hayam M. Lotfy

    Green and sustainable scientific research is crucial for health and environmental improvement. Electrochemical analysis simplifies complex processes, saving time and cost. Ion selective electrode method, a key in green analytical chemistry, was utilized. A highly selective solid contact sensor was developed for two applications, detecting cinnarizine (CIN) and dimenhydrinate (DMH) in pharmaceuticals, and identifying CIN and diphenhydramine (DIP) in human plasma. Careful selection of ionophores ensured accurate detection. Multi-wall carbon-nanotubes (MWCNTs) facilitate rapid and precise measurement. The concentration range for CIN, DMH, and DIP was 1 × 10−6 M to 1 × 10−2 M, with mean recovery% of 100.07 ± 0.80, 100.12 ± 0.76, and 100.07 ± 0.53, respectively. Validation parameters exhibited accuracy and precision, with accuracy results of 100.87 ± 0.89, 99.96 ± 0.42, and 99.82 ± 0.31, and LODs of 0.5 × 10−6, 1.0 × 10−7, and 0.2 × 10−6 for CIN, DMH, and DIP, respectively. The study highlighted benefits like speed, economy, and sustainability, emphasizing the electrode’s reusability. SWOT analysis and environmental assessments further underscored its advantages, promising applications in pharmaceutical analysis and quality control.


  • Novel Carbon Nanotubes/Gold Nanoparticles Modified Carbon Paste Electrochemical Sensor for Antazoline Determination in Aqueous Humor

    by Yasmin Rostom, Ola G. Hussein, Amr M. Mahmoud, Mohamed Abdelkawy, Mamdouh R. Rezk, Dina A. Ahmed

    Antazoline (ANT) is a H1 histamine receptor antagonist having anticholinergic properties used to decrease nasal congestion. It is found in eye drops usually in combination with either tetryzoline (TET) or xylometazoline (XLO). In this work, a novel electrochemical sensor based on carbon paste electrode (CPE) is developed for simple, rapid, sensitive, and selective determination of antazoline in pure form, different pharmaceutical formulations and in presence of aqueous humor. CPE is modified with nanoparticles multiwalled carbon nanotube (MWCNT) composite and further decorated with gold nanoparticles using amperometric electrodeposition technique to attain Au-NP@MWCNT/CPE for enhancing sensor sensitivity. Linearity is divided into two linear segments and found to be 2 × 10–7 − 2 × 10−6 (1st Linear segment) and 2 × 10–6 − 2 × 10−5 (2nd Linear segment) with limit of detection and quantification of 1.77 × 10−7 and 5.37 × 10−7, respectively. High sensitivity, selectivity, and reproducibility of the modified electrode towards determination of antazoline have promoted its applicability in different dosage forms and in rabbit aqueous humor. This method has noticeable potential applications in quality control, pharmacokinetic studies, and routine determination of antazoline drug in binary pharmaceutical formulations.


  • Comparative Study of the Selectivity Power of Colorimetric Method Over Chromatographic Methods for the Analysis of Valaciclovir Hydrochloride

    by Eman M Morgan, Hayam Mahmoud Lotfy, Yasmin Mohammed Fayez, Mohamed Abdelkawy

    Background: Valaciclovir hydrochloride (VAL) is an essential antiviral prodrug used to cure various types of herpes. Analysis of VAL by different analytical techniques demonstrates a persuasive aspect that is favorable in quality control application. Objective: This study describes a comparison between colorimetric and chromatographic (RP-high performance liquid chromatography (HPLC) and thin-layer chromatography (TLC)-densitometric) methods concerning selectivity and specificity for the determination of VAL in all possible degradation products (alkali- and acid-induced degradation products, namely aciclovir [ACI] and guanine [GUA], respectively) in their synthetic mixture and pharmaceutical formulations. Method: The colorimetric method was accomplished by forming a highly colored complex with ferric hydroxamate reagent measured at 493 nm in the concentration range (0.20–1.60 mg/mL). Both chromatographic methods were successfully applied using ultraviolet (UV) detection at 256 nm in the concentration range (2.00–5.00 µg/mL) for the RP-HPLC method and (10.00–900.00 ng/band) for the TLC-densitometric method. Results: The linearity studies, regression equations, assay parameters, and validation sheet of the proposed colorimetric and chromatographic methods to determine VAL were obtained with highly acceptable values. Conclusions: The International Council for Harmonization (ICH) guidelines were followed to validate the described methods and the statistical comparison regarding both accuracy and precision, and satisfactory results were accomplished. Highlights: In this study, we configure a full comparative study between different analytical methods for the analysis of challengeable mixture containing the drug of interest, VAL, along with its degradation products, ACI and GUA.


  • Green and Cost-Effective Extraction Techniques of Quercetin from Mixture of Nutraceuticals with Yield Analysis via Spectrophotometry and High-Performance Liquid Chromatography Methods

    by Mohammed Gamal, Heba-Alla H Abd-ElSalam, Ibrahim A Naguib, Medhat A Al-Ghobashy, Hala E Zaazaa, M Abdelkawy

    Background: Extraction is the leading critical stage in the analysis of nutraceuticals. Ginkgo biloba (GB) has gained interest because of its therapeutic usages. Objectives: The aim was to develop four cost-effective extraction techniques for the extraction of quercetin from GB in a sachet containing a mixture of nutraceuticals. These techniques are solid-phase extraction (SPE), liquid–liquid extraction, inverted dispersive liquid–liquid microextraction, and the QuEChERS (quick, easy, cheap, effective, rugged, and safe) method. Method: Direct spectrophotometry was used to monitor the recovery of the standard quercetin throughout the optimization steps. The HPLC–UV method of analysis was optimized to quantify the yields from the extracts present in the complicated contents of the sachets. The present study was assessed by analytical Eco-Scale assessment (ESA) and the National Environmental Method Index (NEMI) for greenness in comparison with the literature. Results: SPE showed the best cleanup outcomes. ESA and NEMI showed an adequate greenness of the proposed extraction protocol. Conclusions: Quercetin (marker for GB) extraction from market nutraceutical sachets is considered an exemplar for analysis in the QC of nutraceuticals. Regarding the greenness results, the proposed method of extraction is better even with adequate greenness as the extraction was a one-step process, in comparison with multistep processes of previously published protocols. Accordingly, it is recommended for use in routine extraction and analysis of such nutraceuticals. Highlights: Four extraction protocols have been developed. For GB ternary-mixture sachets, proper recovery was obtained using C18 SPE. The assessment of greenness of the proposed protocol guaranteed the superiority of the presented method. Safer sorbents and chemicals are favored for use in routine extraction of nutraceuticals.