Daria Yu. Subbotina
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Daria Yu. Subbotina has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Tatiyana V. Nurislamova
Federal Scientific Center for Medical and Preventive Health Risk Management Technologies of the Federal Service for Surveillance over Consumer Rights Protection and Human Wellbeing
4 shared publications - Olga Andreevna Maltseva
Federal Scientific Center for Medical and Preventive Health Risk Management Technologies
3 shared publications - Nina Anatolyevna Popova
Federal Scientific Center for Medical and Preventive Health Risk Management Technologies
2 shared publications - Tatyana V. Chinko
ФбУН «ФНЦ медико-профилактических технологий управления рисками здоровью населения
2 shared publications - Ekaterina A. Yakusheva
Federal Scientific Center for Medical and Preventive Health Risk Management Technologies
1 shared publication - Gennady I. Terentyev
Federal Scientific Center for Medical and Preventive Health Risk Management Technologies
1 shared publication
Latest Publications
- 19 December 2025
- Published by Federal Scientific Center for Hygiene F.F.Erisman in Hygiene and sanitation
- Vol. 104 (11)
Developing an express method for quantification of fatty acids in urine based on chromatography-mass spectrometric analysis
Introduction. Quantitative determination of fatty acids (FA) in biological fluids allows assessing of dietary intake, their role in biochemical processes, physiological functions, such as normal brain and heart function. Objective. To develop a rapid method for the quantitative determination of fatty acids in urine based on chromatograph mass spectrometry analysis for assessing nutritional status. Materials and Methods. Preparation of urine samples for chemical analysis of fatty acids included alkaline methylation by treating the biosample with potassium methylate, which enabled rapid and quantitative methylation of both free fatty acids and triglycerides. A capillary column with an FFAP with a programmable heating mode of 70–245 °C was used to separate fatty acid esters. The quadrupole mass spectrometer with electron ionization.Results. The developed rapid method based on chromatographic mass spectrometry (CMS) allows analysing the fatty acid composition in urine, identifying 34 of their derivatives in a concentration range from 0.004 to 9.975 µg/cm³. The conducted studies revealed the following maximum fatty acid concentrations: eicosatrienoic acid (3.608 µg/cm3) in 100% and tricosanoic acid (0.351 µg/cm3) in 91.2% of healthy individuals. Limitations. Study limitations may be related to the need to exclude the determination of an incomplete spectrum of fatty acids, such as hydroxy acids. Conclusion. Metabolomic analysis of urine for FA composition may be a promising direction for assessing nutritional status and identifying biomarkers characterizing changes in alimentary factors. Compliance with ethical standards. The study was approved by the local ethics committee of the Rospotrebnadzor’s Federal Scientific Center for Medical and Preventive Health Risk Management Technologies (the meeting protocol No. 3 dated March 28, 2025). All participants gave informed voluntary written consent to participate in the study.Contribution: Nurislamova T.V., Lear D.N. – concept, study design, editing; Terentyev G.I. – collection and treatment of material, analysis of obtained data, writing the text; Subbotina D.Yu., Yakusheva E.A. – collection and treatment of material, analysis of obtained data; Suvorov D.V. – collection and treatment of material. All authors are responsible for the integrity of all parts of the manuscript and approval of the manuscript final version.Conflict of interest. The authors declare no conflict of interest.Funding. The study had no sponsorship.Received: September 9, 2025 / Revised: October 24, 2025 / Accepted: November 3, 2025 / Published: December 19, 2025
- 19 December 2025
- Published by Federal Scientific Center for Hygiene F.F.Erisman in Hygiene and sanitation
- Vol. 104 (11)
Developing an express method for quantification of fatty acids in urine based on chromatography-mass spectrometric analysis
Introduction. Quantitative determination of fatty acids (FA) in biological fluids allows assessing of dietary intake, their role in biochemical processes, physiological functions, such as normal brain and heart function. Objective. To develop a rapid method for the quantitative determination of fatty acids in urine based on chromatograph mass spectrometry analysis for assessing nutritional status. Materials and Methods. Preparation of urine samples for chemical analysis of fatty acids included alkaline methylation by treating the biosample with potassium methylate, which enabled rapid and quantitative methylation of both free fatty acids and triglycerides. A capillary column with an FFAP with a programmable heating mode of 70–245 °C was used to separate fatty acid esters. The quadrupole mass spectrometer with electron ionization.Results. The developed rapid method based on chromatographic mass spectrometry (CMS) allows analysing the fatty acid composition in urine, identifying 34 of their derivatives in a concentration range from 0.004 to 9.975 µg/cm³. The conducted studies revealed the following maximum fatty acid concentrations: eicosatrienoic acid (3.608 µg/cm3) in 100% and tricosanoic acid (0.351 µg/cm3) in 91.2% of healthy individuals. Limitations. Study limitations may be related to the need to exclude the determination of an incomplete spectrum of fatty acids, such as hydroxy acids. Conclusion. Metabolomic analysis of urine for FA composition may be a promising direction for assessing nutritional status and identifying biomarkers characterizing changes in alimentary factors. Compliance with ethical standards. The study was approved by the local ethics committee of the Rospotrebnadzor’s Federal Scientific Center for Medical and Preventive Health Risk Management Technologies (the meeting protocol No. 3 dated March 28, 2025). All participants gave informed voluntary written consent to participate in the study.Contribution: Nurislamova T.V., Lear D.N. – concept, study design, editing; Terentyev G.I. – collection and treatment of material, analysis of obtained data, writing the text; Subbotina D.Yu., Yakusheva E.A. – collection and treatment of material, analysis of obtained data; Suvorov D.V. – collection and treatment of material. All authors are responsible for the integrity of all parts of the manuscript and approval of the manuscript final version.Conflict of interest. The authors declare no conflict of interest.Funding. The study had no sponsorship.Received: September 9, 2025 / Revised: October 24, 2025 / Accepted: November 3, 2025 / Published: December 19, 2025
- 20 October 2025
- Published by Federal Scientific Center for Hygiene F.F.Erisman in Hygiene and sanitation
- Vol. 104 (9) , 1216-1222
Methods for measuring mass concentrations of xylene isomers in ambient air (literature review)
Ambient air is the most important life-support component of the ecosystem, so its pollution is a powerful and permanent factor influencing on both humans and the environment. Volatile organic aromatic compounds are the main group of pollutants that affect human health. For effective analytical control of the environmental quality, highly sensitive and selective methods for determining xylenes in ambient air are necessary.The aim of this study. To examine the results of theoretical and experimental research, methods and procedures for measuring mass concentrations of xylene isomers in ambient air.The review focuses on data available in scientific literature published in the abstract databases of Web of Science, Pubmed, Scopus, and Elibrary, devoted to studying the content of xylenes in ambient air.A review of Russian and foreign scientific literature on physicochemical methods for controlling determination of xylenes in air has revealed organic compounds to be determined using chromato-mass-spectrometry with thermal desorption involved in the sampling stage.Conclusion. This analysis of scientific and methodological literature has shown sorption concentration on solid sorbents (porous polymer sorbents) to be the most widely used sampling method to determine the content of xylenes in ambient air. The optimal way to extract xylenes from a sorbent is thermal desorption of the selected sample directly into the column of gas chromatograph and subsequent gas chromatographic analysis.Contribution: Nurislamova T.V. — study concept and design, editing the text; Popova N.A. — study concept and design, editing the text; Maltseva O.A. — study concept and design, editing the text; Kolmogortseva D.Yu. — literature data collection and analysis, writing the text. All authors are responsible for the integrity of all parts of the manuscript and approval of its final version.Conflict of interest. The authors declare no conflict of interest.Funding. The study had no sponsorship.Received: June 10, 2025 / Revised: August 8, 2025 / Accepted: September 25, 2025 / Published: October 20, 2025
- 20 October 2025
- Published by Federal Scientific Center for Hygiene F.F.Erisman in Hygiene and sanitation
- Vol. 104 (9) , 1216-1222
Methods for measuring mass concentrations of xylene isomers in ambient air (literature review)
Ambient air is the most important life-support component of the ecosystem, so its pollution is a powerful and permanent factor influencing on both humans and the environment. Volatile organic aromatic compounds are the main group of pollutants that affect human health. For effective analytical control of the environmental quality, highly sensitive and selective methods for determining xylenes in ambient air are necessary.The aim of this study. To examine the results of theoretical and experimental research, methods and procedures for measuring mass concentrations of xylene isomers in ambient air.The review focuses on data available in scientific literature published in the abstract databases of Web of Science, Pubmed, Scopus, and Elibrary, devoted to studying the content of xylenes in ambient air.A review of Russian and foreign scientific literature on physicochemical methods for controlling determination of xylenes in air has revealed organic compounds to be determined using chromato-mass-spectrometry with thermal desorption involved in the sampling stage.Conclusion. This analysis of scientific and methodological literature has shown sorption concentration on solid sorbents (porous polymer sorbents) to be the most widely used sampling method to determine the content of xylenes in ambient air. The optimal way to extract xylenes from a sorbent is thermal desorption of the selected sample directly into the column of gas chromatograph and subsequent gas chromatographic analysis.Contribution: Nurislamova T.V. — study concept and design, editing the text; Popova N.A. — study concept and design, editing the text; Maltseva O.A. — study concept and design, editing the text; Kolmogortseva D.Yu. — literature data collection and analysis, writing the text. All authors are responsible for the integrity of all parts of the manuscript and approval of its final version.Conflict of interest. The authors declare no conflict of interest.Funding. The study had no sponsorship.Received: June 10, 2025 / Revised: August 8, 2025 / Accepted: September 25, 2025 / Published: October 20, 2025
- 30 August 2023
- Published by Federal Scientific Center for Hygiene F.F.Erisman in Hygiene and sanitation
- Vol. 102 (7) , 713-719
Methodical support for controlling safety of cereals for children (exemplified by furan and methylfuran)
Introduction. The study addresses issues related to developing a procedure for identification of chemicals in food products in practical instrumental investigations. We have validated the method for quantification of a heterocyclic compound (furan) and sylvan (methylfuran) in grain-based cereals for children. The aim of this study was to develop a precise GC-MS-method for quantifying a heterocyclic compound and sylvan in food products to control their safety for children, especially infants. Materials and methods. The research objects were quantification means (QM) as a certain amount of an analyzed heterocyclic compound and sylvan (the mass share of the analyzed compound is 99%) provided by Sigma Aldrich Corporation (USA), as well as milk and milk-free dry cereals for babies. The study involved using an Agilent 7890А gas chromatographer with 5975С quadrupole mass-spectrometric detector. Sample preparation involved extraction and concentration of furan and methylfuran from food samples by statistical vapour-liquid equilibrium analysis and subsequent gas-chromatographic analysis of vapour phase. Results. The procedure for quantification of furan and methylfuran is an original scientific and technical development based on experimental data. It gives an opportunity to identify furan and methylfuran micro-admixtures in food samples with high precision and sensitivity with a range of concentrations between 0.93 and 9.37 ng and between 0.91 and 9.13 ng accordingly. The ultimate indicators describing acceptability of the results obtained by furan and methylfuran quantification included error not higher than 24%, пintra-laboratory precision (σRл ) not higher than 10%, correctness (± σCл ) not higher than 22%. Conclusion. The developed technique has shown high selectivity, sensitivity, reliability and satisfactory accuracy. The methodology meets the criteria of the State Standard of the Russian Federation GOST R ISO 5725-1-6-2002 and can be used for laboratory studies of food safety by enterprises and institutions engaged in quality control and research of food products and food raw materials.
- 30 August 2023
- Published by Federal Scientific Center for Hygiene F.F.Erisman in Hygiene and sanitation
- Vol. 102 (7) , 713-719
Methodical support for controlling safety of cereals for children (exemplified by furan and methylfuran)
Introduction. The study addresses issues related to developing a procedure for identification of chemicals in food products in practical instrumental investigations. We have validated the method for quantification of a heterocyclic compound (furan) and sylvan (methylfuran) in grain-based cereals for children. The aim of this study was to develop a precise GC-MS-method for quantifying a heterocyclic compound and sylvan in food products to control their safety for children, especially infants. Materials and methods. The research objects were quantification means (QM) as a certain amount of an analyzed heterocyclic compound and sylvan (the mass share of the analyzed compound is 99%) provided by Sigma Aldrich Corporation (USA), as well as milk and milk-free dry cereals for babies. The study involved using an Agilent 7890А gas chromatographer with 5975С quadrupole mass-spectrometric detector. Sample preparation involved extraction and concentration of furan and methylfuran from food samples by statistical vapour-liquid equilibrium analysis and subsequent gas-chromatographic analysis of vapour phase. Results. The procedure for quantification of furan and methylfuran is an original scientific and technical development based on experimental data. It gives an opportunity to identify furan and methylfuran micro-admixtures in food samples with high precision and sensitivity with a range of concentrations between 0.93 and 9.37 ng and between 0.91 and 9.13 ng accordingly. The ultimate indicators describing acceptability of the results obtained by furan and methylfuran quantification included error not higher than 24%, пintra-laboratory precision (σRл ) not higher than 10%, correctness (± σCл ) not higher than 22%. Conclusion. The developed technique has shown high selectivity, sensitivity, reliability and satisfactory accuracy. The methodology meets the criteria of the State Standard of the Russian Federation GOST R ISO 5725-1-6-2002 and can be used for laboratory studies of food safety by enterprises and institutions engaged in quality control and research of food products and food raw materials.
- 31 October 2021
- Published by Federal Scientific Center for Hygiene F.F.Erisman in Hygiene and sanitation
- Vol. 100 (10) , 1145-1150
Chromatography-mass spectrometric determination of highly toxic and carcinogenic N-nitrosamines in water
Introduction. In Russia, the current condition regarding water quality in the water bodies of the Russian Federation used for drinking purposes “continues to remain unfavourable (according to the Strategy of the Environmental Safety of the Russian Federation until 2025). It takes place primarily due to the discharges of industrial and domestic wastewater.” Thus, 19% of wastewater is discharged into water bodies without purification, 70% - insufficiently purified, and only 11% - purified to the established acceptable discharge standards. Therefore, 30-40% of the country’s population regularly uses water that does not correspond to the hygienic standards, which leads to an increased risk of morbidity among the population of Russia. This study aims to execute chromatography-mass spectrometric determination of highly toxic and carcinogenic N-nitrosamines in drinking water. Materials and methods. Within the framework of the study, we reviewed standard samples of N-nitrosamines Mix, 1X1ML, 2000 ug/ml, methanol, experimental diagrams of solid-phase extraction. The practical charts of solid-phase extraction were tested with the help of a susceptible and accurate analytical mass-spectrometric method, a gas chromatograph with a mass selective detector (MSD). An internal laboratory control was carried out according to CIS standardization recommendations 76-2014 of the State System for Ensuring Uniform Measurement to ensure the reliability of the analytical results obtained to determine N-nitrosamines in water. The quality indicators for the analysis results were experimentally established: the accuracy, correctness, precision of the analysis technique, and the methods for their assessment according to GOST R ISO 5725-2002 standards. Results. In the course of the performed experimental studies, it was found that the degree of N-nitrosamines extraction from water samples of 100 ml volume, through scavenging analytes on a carbon cartridge (Coconut 6 cm3) and using four optimal diagrams of solid-phase extraction - SPE for N-dimethyl nitrosamine, N-diethyl nitrosamine, N-dipropyl nitrosamine, N-piperidine nitrosamine was 73.9%, 90.8%, 100 and 95.4% respectively. Optimal elution scheme 4: stage 1 - conditioning the cartridge to activate it: 5 ml methylene chloride for 3 seconds, 5 ml ethyl acetate for 3 seconds, rinsing the cartridge with 5 ml water for 10 seconds. Stage 2 - adsorption of a 100 ml water sample on a 6 ml Coconut cartridge for 1 minute; stage 3 - rinsing the cartridge with 5% sodium chloride solution of 10 ml for 30 seconds; stage 4-elution of N-nitrosamines from the cartridge with methylene chloride of 3 ml for 3 min. into a test tube in position 1 of the carriage of the automatic TFE system. The method for the determination of N-nitrosamines in water is based on the concentration of the analyzed compounds of water samples on a carbon cartridge - solid-phase extraction (SPE), identification of substances by library mass spectra and retention time, quantitative determination according to the calibration graph on a high polarity capillary column HP-FFAP-50 m • 0.32 mm • 0.50 μm. Conclusion. The developed guidelines for measuring the N-nitrosamines content in the water of centralized water supply systems let us determine highly toxic compounds at the lower limit of 0.00004 μg/cm3 with an error of more than 35.0%.
- 31 October 2021
- Published by Federal Scientific Center for Hygiene F.F.Erisman in Hygiene and sanitation
- Vol. 100 (10) , 1145-1150
Chromatography-mass spectrometric determination of highly toxic and carcinogenic N-nitrosamines in water
Introduction. In Russia, the current condition regarding water quality in the water bodies of the Russian Federation used for drinking purposes “continues to remain unfavourable (according to the Strategy of the Environmental Safety of the Russian Federation until 2025). It takes place primarily due to the discharges of industrial and domestic wastewater.” Thus, 19% of wastewater is discharged into water bodies without purification, 70% - insufficiently purified, and only 11% - purified to the established acceptable discharge standards. Therefore, 30-40% of the country’s population regularly uses water that does not correspond to the hygienic standards, which leads to an increased risk of morbidity among the population of Russia. This study aims to execute chromatography-mass spectrometric determination of highly toxic and carcinogenic N-nitrosamines in drinking water. Materials and methods. Within the framework of the study, we reviewed standard samples of N-nitrosamines Mix, 1X1ML, 2000 ug/ml, methanol, experimental diagrams of solid-phase extraction. The practical charts of solid-phase extraction were tested with the help of a susceptible and accurate analytical mass-spectrometric method, a gas chromatograph with a mass selective detector (MSD). An internal laboratory control was carried out according to CIS standardization recommendations 76-2014 of the State System for Ensuring Uniform Measurement to ensure the reliability of the analytical results obtained to determine N-nitrosamines in water. The quality indicators for the analysis results were experimentally established: the accuracy, correctness, precision of the analysis technique, and the methods for their assessment according to GOST R ISO 5725-2002 standards. Results. In the course of the performed experimental studies, it was found that the degree of N-nitrosamines extraction from water samples of 100 ml volume, through scavenging analytes on a carbon cartridge (Coconut 6 cm3) and using four optimal diagrams of solid-phase extraction - SPE for N-dimethyl nitrosamine, N-diethyl nitrosamine, N-dipropyl nitrosamine, N-piperidine nitrosamine was 73.9%, 90.8%, 100 and 95.4% respectively. Optimal elution scheme 4: stage 1 - conditioning the cartridge to activate it: 5 ml methylene chloride for 3 seconds, 5 ml ethyl acetate for 3 seconds, rinsing the cartridge with 5 ml water for 10 seconds. Stage 2 - adsorption of a 100 ml water sample on a 6 ml Coconut cartridge for 1 minute; stage 3 - rinsing the cartridge with 5% sodium chloride solution of 10 ml for 30 seconds; stage 4-elution of N-nitrosamines from the cartridge with methylene chloride of 3 ml for 3 min. into a test tube in position 1 of the carriage of the automatic TFE system. The method for the determination of N-nitrosamines in water is based on the concentration of the analyzed compounds of water samples on a carbon cartridge - solid-phase extraction (SPE), identification of substances by library mass spectra and retention time, quantitative determination according to the calibration graph on a high polarity capillary column HP-FFAP-50 m • 0.32 mm • 0.50 μm. Conclusion. The developed guidelines for measuring the N-nitrosamines content in the water of centralized water supply systems let us determine highly toxic compounds at the lower limit of 0.00004 μg/cm3 with an error of more than 35.0%.