Elzbieta Marciniak
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Elzbieta Marciniak has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Tomasz Marciniak
Division of Electronic Systems and Signal Processing, Institute of Automatic Control and Robotics, Poznan University of Technology, 60-965 Poznan, Poland
6 shared publications - Agnieszka Stankiewicz
Division of Electronic Systems and Signal Processing, Institute of Automatic Control and Robotics, Poznan University of Technology, 60-965 Poznan, Poland
5 shared publications - Marcin Stopa
Department of Ophthalmology, Chair of Ophthalmology and Optometry, Poznan University Hospital, Poznan University of Medical Sciences, Poznan, Poland
5 shared publications - Adam Dąbrowski
Poznan University of Technology, Faculty of Control, Robotics & Electrical Engineering, Institute of Automatic Control and Robotics, ul. Piotrowo 3a, 60-965 Poznan, Poland
4 shared publications - Alicja Anna Ignatowicz
Division of Electronic Systems and Signal Processing, Institute of Automatic Control and Robotics, Faculty of Control, Robotics and Electrical Engineering, Poznan University of Technology, Poznan, Poland
2 shared publications Piotr Rakowicz
Clinical Eye Unit and Pediatric Ophthalmology Service, Heliodor Swiecicki University Hospital, Poznan University of Medical Sciences, Poznan, Poland
2 shared publications
Latest Publications
- Open Access
- 5 August 2026
- Published by Springer Nature in Scientific Data
CAVRI-H5: A Homogeneous OCT Dataset for Retinal Classification Featuring VMA-VMT Pathologies
- 5 August 2026
- Published by Springer Nature in Scientific Data
Open AccessCAVRI-H5: A Homogeneous OCT Dataset for Retinal Classification Featuring VMA-VMT Pathologies
- Open Access
AI-Powered Mobile App for Nuclear Cataract Detection
Cataract remains the leading cause of blindness worldwide, and the number of individuals affected by this condition is expected to rise significantly due to global population ageing. Early diagnosis is crucial, as delayed treatment may result in irreversible vision loss. This study explores and presents a mobile application for Android devices designed for the detection of cataracts using deep learning models. The proposed solution utilizes a multi-stage classification approach to analyze ocular images acquired with a slit lamp, sourced from the Nuclear Cataract Database for Biomedical and Machine Learning Applications. The process involves identifying pathological features and assessing the severity of the detected condition, enabling comprehensive characterization of the NC (nuclear cataract) of cataract progression based on the LOCS III scale classification. The evaluation included a range of convolutional neural network architectures, from larger models like VGG16 and ResNet50, to lighter alternatives such as VGG11, ResNet18, MobileNetV2, and EfficientNet-B0. All models demonstrated comparable performance, with classification accuracies exceeding 91–94.5%. The trained models were optimized for mobile deployment, enabling real-time analysis of eye images captured with the device camera or selected from local storage. The presented mobile application, trained and validated on authentic clinician-labeled pictures, represents a significant advancement over existing mobile tools. The preliminary evaluations demonstrated a high accuracy in cataract detection and severity grading. These results confirm the approach is feasible and will serve as the foundation for ongoing development and extensions.
Open AccessAI-Powered Mobile App for Nuclear Cataract Detection
Cataract remains the leading cause of blindness worldwide, and the number of individuals affected by this condition is expected to rise significantly due to global population ageing. Early diagnosis is crucial, as delayed treatment may result in irreversible vision loss. This study explores and presents a mobile application for Android devices designed for the detection of cataracts using deep learning models. The proposed solution utilizes a multi-stage classification approach to analyze ocular images acquired with a slit lamp, sourced from the Nuclear Cataract Database for Biomedical and Machine Learning Applications. The process involves identifying pathological features and assessing the severity of the detected condition, enabling comprehensive characterization of the NC (nuclear cataract) of cataract progression based on the LOCS III scale classification. The evaluation included a range of convolutional neural network architectures, from larger models like VGG16 and ResNet50, to lighter alternatives such as VGG11, ResNet18, MobileNetV2, and EfficientNet-B0. All models demonstrated comparable performance, with classification accuracies exceeding 91–94.5%. The trained models were optimized for mobile deployment, enabling real-time analysis of eye images captured with the device camera or selected from local storage. The presented mobile application, trained and validated on authentic clinician-labeled pictures, represents a significant advancement over existing mobile tools. The preliminary evaluations demonstrated a high accuracy in cataract detection and severity grading. These results confirm the approach is feasible and will serve as the foundation for ongoing development and extensions.
- Open Access
Segmentation of Preretinal Space in Optical Coherence Tomography Images Using Deep Neural Networks
This paper proposes an efficient segmentation of the preretinal area between the inner limiting membrane (ILM) and posterior cortical vitreous (PCV) of the human eye in an image obtained with the use of optical coherence tomography (OCT). The research was carried out using a database of three-dimensional OCT imaging scans obtained with the Optovue RTVue XR Avanti device. Various types of neural networks (UNet, Attention UNet, ReLayNet, LFUNet) were tested for semantic segmentation, their effectiveness was assessed using the Dice coefficient and compared to the graph theory techniques. Improvement in segmentation efficiency was achieved through the use of relative distance maps. We also show that selecting a larger kernel size for convolutional layers can improve segmentation quality depending on the neural network model. In the case of PVC, we obtain the effectiveness reaching up to . The proposed solution can be widely used to diagnose vitreomacular traction changes, which is not yet available in scientific or commercial OCT imaging solutions.Open AccessSegmentation of Preretinal Space in Optical Coherence Tomography Images Using Deep Neural Networks
This paper proposes an efficient segmentation of the preretinal area between the inner limiting membrane (ILM) and posterior cortical vitreous (PCV) of the human eye in an image obtained with the use of optical coherence tomography (OCT). The research was carried out using a database of three-dimensional OCT imaging scans obtained with the Optovue RTVue XR Avanti device. Various types of neural networks (UNet, Attention UNet, ReLayNet, LFUNet) were tested for semantic segmentation, their effectiveness was assessed using the Dice coefficient and compared to the graph theory techniques. Improvement in segmentation efficiency was achieved through the use of relative distance maps. We also show that selecting a larger kernel size for convolutional layers can improve segmentation quality depending on the neural network model. In the case of PVC, we obtain the effectiveness reaching up to . The proposed solution can be widely used to diagnose vitreomacular traction changes, which is not yet available in scientific or commercial OCT imaging solutions. - 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 31, 279-283
Reliability of Fovea Features Measurement from 3D OCT Images for Monitoring Treatment Outcome
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 31, 279-283
Reliability of Fovea Features Measurement from 3D OCT Images for Monitoring Treatment Outcome
- 1 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Automatic modeling and classification of vitreomacular traction pathology stages
Retinal pathologies that are detected too late and/or left untreated can seriously damage eyesight. It is important to monitor the retina and react to any pathological changes. A fast, accurate, non-invasive, and even three-dimensional retina examination is the optical coherence tomography (OCT). In this paper we propose a new automated classification method for evaluation of vitreomacular interface (VRI) in human eyes. We present an approach for modelling changes in retina structure during the progression of vitreomacular traction (VMT) pathology. Presented experiments were performed on volumetric data acquired from adult patients with the use of Avanti RTvue device. Advanced digital image processing algorithms were subsequently applied to each OCT cross-section (B-scan) for image denoising and flattening, as well as retina layers segmentation. The proposed solution has a good accuracy and almost all subjects were successfully classified into one of 4 groups corresponding to various stages of VMT. The developed models of VMT stages show a high potential of the proposed method to support ophthalmologists in making appropriate clinical decisions.
- 1 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Automatic modeling and classification of vitreomacular traction pathology stages
Retinal pathologies that are detected too late and/or left untreated can seriously damage eyesight. It is important to monitor the retina and react to any pathological changes. A fast, accurate, non-invasive, and even three-dimensional retina examination is the optical coherence tomography (OCT). In this paper we propose a new automated classification method for evaluation of vitreomacular interface (VRI) in human eyes. We present an approach for modelling changes in retina structure during the progression of vitreomacular traction (VMT) pathology. Presented experiments were performed on volumetric data acquired from adult patients with the use of Avanti RTvue device. Advanced digital image processing algorithms were subsequently applied to each OCT cross-section (B-scan) for image denoising and flattening, as well as retina layers segmentation. The proposed solution has a good accuracy and almost all subjects were successfully classified into one of 4 groups corresponding to various stages of VMT. The developed models of VMT stages show a high potential of the proposed method to support ophthalmologists in making appropriate clinical decisions.
- Open Access
- 1 June 2016
- Published by Walter de Gruyter GmbH in Metrology and Measurement Systems
- Vol. 23 (2) , 269-280
Improving Segmentation of 3D Retina Layers Based on Graph Theory Approach for Low Quality OCT Images
This paper presents signal processing aspects for automatic segmentation of retinal layers of the human eye. The paper draws attention to the problems that occur during the computer image processing of images obtained with the use of the Spectral Domain Optical Coherence Tomography (SD OCT). Accuracy of the retinal layer segmentation for a set of typical 3D scans with a rather low quality was shown. Some possible ways to improve quality of the final results are pointed out. The experimental studies were performed using the so-called B-scans obtained with the OCT Copernicus HR device
- 1 June 2016
- Published by Walter de Gruyter GmbH in Metrology and Measurement Systems
- Vol. 23 (2) , 269-280
Open AccessImproving Segmentation of 3D Retina Layers Based on Graph Theory Approach for Low Quality OCT Images
This paper presents signal processing aspects for automatic segmentation of retinal layers of the human eye. The paper draws attention to the problems that occur during the computer image processing of images obtained with the use of the Spectral Domain Optical Coherence Tomography (SD OCT). Accuracy of the retinal layer segmentation for a set of typical 3D scans with a rather low quality was shown. Some possible ways to improve quality of the final results are pointed out. The experimental studies were performed using the so-called B-scans obtained with the OCT Copernicus HR device