Marco Maria Lirici
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Marco Maria Lirici has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- L. Angelini
Department of Surgical Sciences and Applied Technologies, Policlinico Umberto I, Rome, Italy
2 shared publications V. Papaspyropoulos
FOurth Department of Surgery, University La Sapienza, Rome, Italy
2 shared publicationsAlessia Fassari
Department of Surgery, San Giovanni Addolorata Hospital Complex, Rome, Italy
1 shared publication- Andreas Melzer
IMSaT Institute for Medical Science and Technology, Dundee, UK
1 shared publication - Eiji Kanehira
Department of Surgery, Medical Topia Soka, 1-11-18 Yatsuka, Soka City, Saitama, 3400028, Japan.
1 shared publication Emanuele Santoro
Department of Surgery, San Giovanni Addolorata Hospital Complex, Rome, Italy
1 shared publication
Latest Publications
- 11 November 2021
- Published by Springer Nature in Updates in Surgery
- Vol. 73 (6) , 2381-2384
Trans-vaginal repair of recurrent rectovaginal fistula with interposition of BIO-A Tissue Reinforcement
Rectovaginal fistulas (RVFs) represent the majority of all symptomatic leakages after anterior and low anterior resection in women. Conservative management is useful in paucisymptomatic patients with small fistulas but is usually unsuccessful in all other cases. The surgical strategies are various and heavily dependent on the type and extent of anatomic involvement. We present a case of a 51-year-old female with a multi-recurrent rectovaginal fistula that occurred since a laparoscopic sigmoidectomy was performed for a complicated diverticular disease in May 2015. An attempt to close the fistula was undertaken three times. In July 2019, a transvaginal repair was performed with interposition in the rectovaginal septum of GORE® BIO-A® Tissue Reinforcement. The postoperative course was uneventful. There was no recurrence and functional outcome was good at 24-months follow-up. Rectovaginal fistula can be successfully treated using the interposition of a GORE® BIO-A® Tissue Reinforcement with significant economic savings and good functional outcomes even through a transvaginal approach. It represents a therapeutic option for an otherwise difficult-to-treat complex fistula.
- 11 November 2021
- Published by Springer Nature in Updates in Surgery
- Vol. 73 (6) , 2381-2384
Trans-vaginal repair of recurrent rectovaginal fistula with interposition of BIO-A Tissue Reinforcement
Rectovaginal fistulas (RVFs) represent the majority of all symptomatic leakages after anterior and low anterior resection in women. Conservative management is useful in paucisymptomatic patients with small fistulas but is usually unsuccessful in all other cases. The surgical strategies are various and heavily dependent on the type and extent of anatomic involvement. We present a case of a 51-year-old female with a multi-recurrent rectovaginal fistula that occurred since a laparoscopic sigmoidectomy was performed for a complicated diverticular disease in May 2015. An attempt to close the fistula was undertaken three times. In July 2019, a transvaginal repair was performed with interposition in the rectovaginal septum of GORE® BIO-A® Tissue Reinforcement. The postoperative course was uneventful. There was no recurrence and functional outcome was good at 24-months follow-up. Rectovaginal fistula can be successfully treated using the interposition of a GORE® BIO-A® Tissue Reinforcement with significant economic savings and good functional outcomes even through a transvaginal approach. It represents a therapeutic option for an otherwise difficult-to-treat complex fistula.
- 12 December 2013
- Published by Taylor & Francis in Minimally Invasive Therapy & Allied Technologies
- Vol. 23 (1) , 1-4
The outburst age: How TEM ignited the MIS revolution
- 12 December 2013
- Published by Taylor & Francis in Minimally Invasive Therapy & Allied Technologies
- Vol. 23 (1) , 1-4
The outburst age: How TEM ignited the MIS revolution
- 1 January 1998
- Published by Taylor & Francis in Minimally Invasive Therapy & Allied Technologies
- Vol. 7 (2) , 89-95
Telemanipulation for application of diagnostic and interventional ultrasound
- 1 January 1998
- Published by Taylor & Francis in Minimally Invasive Therapy & Allied Technologies
- Vol. 7 (2) , 89-95
Telemanipulation for application of diagnostic and interventional ultrasound
- 1 January 1997
- Published by Taylor & Francis in Minimally Invasive Therapy & Allied Technologies
- Vol. 6 (5-6) , 364-378
Telerobotics in medicine and surgery
Summary. The application of telerobotic technologies to medicine and surgery strictly depends on research and development in five main areas: functionality, environment, physical constraints, communication, and security. The clinical application of robotic technology in the field of microsurgery, orthopaedic surgery, and minimally invasive surgery has shown promising results, pushing researchers to further develop computer-aided surgery as well as diagnostics systems and microrobots. Telemanipulation, interface technologies, sensors, vision systems, virtual reality and function integration are employed to re-design the operating theatre, thus enhancing future applications of robotics in surgery. Because of the restrictions in the surgical field, the construction of miniaturized mechanisms is required, being grounded on different technologies: silicon micro-mechanics, surface micro-engineering and LIGA technology. Nanotechnology, memory alloys and superelastic materials are also employed. Other technological issues are: the communication of vocal, visual, textual and numerical information via cable, satellite or laser satellite transmission. Security and confidentiality of data are fundamental for telematics applied to medicine. Problems to be solved are the quality of image transmission and the signal delay as well as those related to working in a dynamic environment.
- 1 January 1997
- Published by Taylor & Francis in Minimally Invasive Therapy & Allied Technologies
- Vol. 6 (5-6) , 364-378
Telerobotics in medicine and surgery
Summary. The application of telerobotic technologies to medicine and surgery strictly depends on research and development in five main areas: functionality, environment, physical constraints, communication, and security. The clinical application of robotic technology in the field of microsurgery, orthopaedic surgery, and minimally invasive surgery has shown promising results, pushing researchers to further develop computer-aided surgery as well as diagnostics systems and microrobots. Telemanipulation, interface technologies, sensors, vision systems, virtual reality and function integration are employed to re-design the operating theatre, thus enhancing future applications of robotics in surgery. Because of the restrictions in the surgical field, the construction of miniaturized mechanisms is required, being grounded on different technologies: silicon micro-mechanics, surface micro-engineering and LIGA technology. Nanotechnology, memory alloys and superelastic materials are also employed. Other technological issues are: the communication of vocal, visual, textual and numerical information via cable, satellite or laser satellite transmission. Security and confidentiality of data are fundamental for telematics applied to medicine. Problems to be solved are the quality of image transmission and the signal delay as well as those related to working in a dynamic environment.