YKYu-Ting Kuo

Yu-Ting Kuo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yu-Ting Kuo has a total of 71 co-authors. Here are the top co-authors by number of shared publications:

  • Hsiu-Po Wang

    Department of Internal Medicine, College of Medicine, National Taiwan University, Taipei, Taiwan

    5 shared publications
  • Chen-Ling Peng

    Division of Endoscopy, Department of Integrated Diagnostics and Therapeutics, National Taiwan University Hospital, Taipei, Taiwan

    3 shared publications
  • Hsiu-Po Wang

    Department of Internal Medicine, National Taiwan University College of Medicine, Taipei, Taiwan

    3 shared publications
  • Hsiu‐Po Wang

    Department of Internal Medicine National Taiwan University Hospital Taipei Taiwan

    2 shared publications
  • Juan Alfonso Maclang Mendoza

    Division of Endoscopy, Department of Integrated Diagnostics and Therapeutics, National Taiwan University Hospital, Taipei, Taiwan

    2 shared publications
  • Jung-Chun Lin

    Division of Gastroenterology, Department of Internal Medicine, Tri-Service General Hospital, National Defense Medical University, Taipei, Taiwan

    2 shared publications

Latest Publications

  • Open Access

    EUS ‐Guided Gastroenterostomy for Malignant Gastric Outlet Obstruction: Morphological Classification to Prevent Stent Misdeployment

    by Yu-Ting Kuo, Chi-Ying Yang, Jiann-Hwa Chen, Szu-Chia Liao, Cheng-Lin Hsieh, Chia-Hsien Wu, Meng-Ying Lin, Chen-Shuan Chung, Kuan-Chih Chen, Mu-Hsien Lee, et al.

    Objective: Stent misdeployment is the most critical adverse event (AE) during endoscopic ultrasound‐guided gastroenterostomy (EUS‐GE). This study aimed to identify predictors of misdeployment in EUS‐GE for malignant gastric outlet obstruction (mGOO). Methods: This multicenter observational study utilized a prospectively maintained registry of consecutive patients undergoing EUS‐GE for mGOO at 13 tertiary centers in Taiwan, with mixed retrospective‐prospective assessment of fluoroscopic morphology (FM) of the gastrointestinal tract near the ligament of Treitz (four types) and EUS morphology (EM) of the target bowel (three types). The primary outcome was the misdeployment. Multivariable analysis identified predictors of misdeployment and survival. Results: Between July 2020 and June 2025, 165 patients were enrolled. Technical and clinical success rates were 98.2% and 95.2%, respectively. Overall AE rate and misdeployment rates were 7.3% and 4.8%, respectively. Same‐session endoscopic salvage succeeded in 87.5% of misdeployment cases. EM type C (cross‐sectional bowel view) carried the highest misdeployment risk (33%) and was the sole independent predictor (adjusted odds ratio 16.9; p = 0.001). FM provided essential complementary risk stratification; FM type II was more common among misdeployment cases (25.0% vs. 3.8%; p = 0.030). Implementation of a stepwise strategy in 2023—prioritizing EM type A/B, avoiding type C, and minimizing stomach–bowel distance—resulted in zero misdeployment. Independent predictors of poor survival included pancreatic cancer, malnutrition, poor performance status, ascites, metastasis, and misdeployment. Conclusion: Stent misdeployment is a significant complication adversely impacting survival. Utilizing integrated EM and FM risk stratification within a stepwise strategy can minimize misdeployment and optimize clinical outcomes. Trial Registration: ClinicalTrials.gov: NCT07230665

  • Open Access

    Impact of wet suction on specimen quality and diagnostic accuracy in EUS-guided tissue acquisition: a systematic review and meta-analysis of randomized controlled trials

    by Po-Feng Huang, Jung-Chun Lin, Tien-Yu Huang, Peng-Jen Chen, Chi-Wei Yang, Yu-Ting Kuo, Hsuan-Wei Chen

    Background and aims: Endoscopic ultrasound-guided tissue acquisition (EUS-TA) is critical for diagnosing solid lesions. The wet-suction technique, which pre-fills the needle lumen with saline, has been proposed to improve specimen quality compared with conventional dry suction. This study aimed to evaluate the efficacy of wet suction versus dry suction in EUS-TA. Objectives: This study aimed to evaluate the efficacy of wet suction versus dry suction in EUS-TA. Design: We conducted a systematic review and meta-analysis of randomized controlled trials (RCTs) following PRISMA 2020 guidelines. Methods: Electronic searches of PubMed, Embase, Cochrane CENTRAL, and additional databases were performed through January 2025. Primary outcomes were blood contamination, cellularity, and integrity scores; secondary outcomes were diagnostic accuracy and specimen adequacy. Effect sizes were calculated using Hedges’ g or risk ratios (RRs) with 95% confidence intervals (CIs). Results: Seven RCTs (784 patients; 1566 specimens) were included. Wet suction significantly reduced blood contamination (Hedges’ g = 0.289, 95% CI: 0.178–0.401, p < 0.0001) and improved cellularity (Hedges’ g = 0.420, 95% CI: 0.241–0.599, p < 0.0001) with low heterogeneity. Integrity score showed no significant difference ( p = 0.054). Overall diagnostic accuracy was similar between techniques (RR = 1.025, p = 0.548), but subgroup analysis revealed higher accuracy for wet suction in EUS-fine needle aspiration (FNA; RR = 1.162, p = 0.001). Specimen adequacy did not differ significantly ( p = 0.074). Conclusion: Wet suction improves sample quality by reducing blood contamination and increasing cellularity, with potential diagnostic benefit in FNA procedures. Effects on integrity and adequacy remain inconclusive. Larger, standardized trials are warranted to confirm these findings.

    • 4 September 2025
      • Vol. 57  (S 01) , E1003-E1005
    Open Access

    Fistulography-assisted endoscopic ultrasound-guided pancreatic drainage for cannulation of a non-dilated pancreatic duct in postoperative pancreaticocutaneous fistula.

    by Juan Alfonso M Mendoza, Yu-Ting Kuo, Jirat Jiratham-Opas, Chen-Ling Peng, Thawee Ratanachu-Ek, Hsiu-Po Wang

  • Open Access

    Transforming endoscopic approaches to post-pancreaticoduodenectomy anastomotic strictures: beyond the surface

    by Yu-Ting Kuo

    Transforming endoscopic approaches to post-pancreaticoduodenectomy anastomotic strictures: beyond the surface

  • Open Access

    Consensus statements on endoscopic ultrasound‐guided tissue acquisition. Guidelines from the Asian Endoscopic Ultrasound Group

    by Charing Ching‐Ning Chong, Rapat Pittayanon, Nonthalee Pausawasdi, Vikram Bhatia, Nozomi Okuno, Raymond Shing‐Yan Tang, Tsu‐Yao Cheng, Yu‐Ting Kuo, Dongwook Oh, Tae Jun Song, et al.

    Objectives: This consensus was developed by the Asian EUS Group (AEG), who aimed to formulate a set of practice guidelines addressing various aspects of endoscopic ultrasound‐guided tissue acquisition (EUS‐TA).Methods: The AEG initiated the development of consensus statements and formed an expert panel comprising surgeons, gastroenterologists, and pathologists. Three online consensus meetings were conducted to consolidate the statements and votes. The statements were presented and discussed in the first two consensus meetings and revised according to comments. Final voting was conducted at a third consensus meeting. The Grading of Recommendations, Assessment, Development, and Evaluation system was adopted to define the strength of the recommendations and quality of evidence.Results: A total of 20 clinical questions and statements regarding EUS‐TA were formulated. The committee recommended that fine‐needle biopsy (FNB) needles be preferred over conventional fine‐needle aspiration (FNA) needles for EUS‐TA of subepithelial lesions. For solid pancreatic masses, rapid on‐site evaluation is not routinely recommended when FNB needles are used. For dedicated FNB needles, fork‐tip and Franseen‐tip needles have essentially equivalent performance.Conclusion: This consensus provides guidance for EUS‐TA, thereby enhancing the quality of EUS‐TA.


  • Open Access

    Cholecystohepaticogastrostomy: novel endoscopic gallbladder drainage technique to prevent acute cholecystitis following endoscopic ultrasound-guided biliary drainage

    by Juan Alfonso Maclang Mendoza, Yu-Ting Kuo, Chen-Ling Peng, Hsiu-Po Wang

    For malignant distal biliary obstruction (DBO), placing a stent in an antegrade manner across the obstruction and papilla, followed by endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS), establishes dual biliary drainage pathways and may prolong stent patency [1]. However, acute cholecystitis can occur after biliary drainage with a fully covered self-expandable metal stent (FCSEMS) in cases of DBO [2]. We present a novel endoscopic approach for gallbladder drainage via the HGS tract, offering a viable option for high-risk patients who develop acute cholecystitis following FCSEMS placement. A 72-year-old woman with advanced pancreatic adenocarcinoma presented with fever, chills, and hyperbilirubinemia. She had previously undergone EUS-guided gastrojejunostomy for gastric outlet obstruction and EUS-HGS for DBO 1 month prior. Imaging revealed dilated intrahepatic ducts and common bile duct, as well as gallbladder distention, suggesting biliary infection due to HGS stent occlusion. Upon admission, EUS-HGS was performed, and biliary access was obtained via the HGS route, with aspiration of purulent bile. Following successful cystic duct cannulation, selective gallbladder cannulation was confirmed through contrast injection ([Fig. 1], [Video 1]). A plastic stent (7-Fr diameter; 18 cm length; Through & Pass double-pigtail stent; Gadelius Medical, Tokyo, Japan) was placed between the gallbladder and stomach ([Fig. 2]). Additionally, an FCSEMS (10 mm diameter; 7 cm length; SciTech Inc., Seoul, Korea) was placed across the biliary obstruction and the major duodenal papilla following balloon dilation of the HGS tract ([Fig. 3]). Subsequently, an HGS stent (7-Fr diameter; 14 cm length; Through & Pass Type IT; Gadelius Medical) was placed between the intrahepatic duct and the stomach ([Fig. 4]). The patient’s symptoms improved, and she was discharged in stable condition. This novel gallbladder drainage technique via the HGS tract broadens treatment options for high-risk patients at risk of acute cholecystitis following EUS-HGS with FCSEMS. Endoscopy_UCTN_Code_TTT_1AR_2AZ Article published online: 26 November 2024 © 2024. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany

  • Open Access

    Lotus sign: The lumen-apposing metal stent that failed to bloom

    by Gabriel Liu Yuan Cher, Yu-Ting Kuo, Chen-Ling Peng, Hsiu-Po Wang

    Endoscopic ultrasound-guided gastroenterostomy (EUS-GE) with the use of a lumen-apposing metal stent (LAMS) has emerged as a promising modality for the treatment of a malignant gastric outlet obstruction (MGOO) [1]. The design of single-step delivery systems of LAMSs can significantly reduce the risk of adverse events. However, the process of stent deployment is the crucial step in determining the success of EUS-GE. This report describes the case of a patient who underwent EUS-GE with the deployment of the proximal flange of the LAMS failing to open. A 54-year-old man with advanced pancreatic adenocarcinoma presented with vomiting due to MGOO. After admission, EUS-GE with the wireless simplified technique [2] was performed using a 20-mm LAMS (Hot AXIOS stent; Boston Scientific, Marlborough, Massachusetts, USA). The distal flange of the LAMS deployed successfully. However, on deployment of the proximal portion, the most proximal end of the LAMS failed to open, resulting in a lotus-shaped flange in the stomach ([Fig. 1], [Video 1]). Despite gentle manipulation of the internal sheath and allowing some time for the flange to expand, it still failed to bloom. A 20-mm extraction balloon catheter was passed through the narrow opening of the proximal end and inflated carefully to dilate the flange ([Fig. 2], [Video 1]). This was followed by gushing of methylene-blue colored saline that had been previously irrigated into the jejunum. Fluoroscopy confirmed successful placement of the LAMS ([Fig. 3]). A follow-up abdominal X-ray the next day revealed the stable position of the LAMS and the patient progressed uneventfully from a liquid to a regular diet. Caution should be taken in the event of a rare incomplete blooming of a LAMS flange, which indicates that the lumen-apposing force may be reduced and stent migration can occur. Early recognition and intervention may prevent stent misdeployment [3]. Endoscopy_UCTN_Code_CPL_1AL_2AG Article published online: 09 April 2024 © 2024. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany