Johncy Panicker
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Johncy Panicker has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Jai Thilak
Department of Orthopedics, Amrita Institute of Medical Sciences and Research Centre, Kochi, India
3 shared publications Druvan Shaji
Department of Orthopaedics, Amrita Institute of Medical Sciences and Research Centre, Kochi, India
1 shared publicationHarsha Hari
Department of Biostatistics, Amrita Institute of Medical Sciences and Research Centre, Kochi, Kerala, India
1 shared publicationJai Thilak
Department of Orthopaedics, Amrita Institute of Medical Sciences and Research Centre, Kochi, India
1 shared publicationThadi Mohan
Department of Orthopaedics, Amrita Institute of Medical Sciences and Research Centre, Kochi, India
1 shared publication- Vivek Joy
Department of Orthopedics, Amrita Institute of Medical Sciences and Research Centre, Kochi, India
1 shared publication
Latest Publications
- Open Access
- 11 February 2026
- Published by Elsevier in Journal of ISAKOS
- Vol. 17, 101081
Short-term follow-up of arthroscopic anterior cruciate ligament reconstruction using quadrupled hamstring autograft with suture tape reinforcement as an internal brace
- 11 February 2026
- Published by Elsevier in Journal of ISAKOS
- Vol. 17, 101081
Open AccessShort-term follow-up of arthroscopic anterior cruciate ligament reconstruction using quadrupled hamstring autograft with suture tape reinforcement as an internal brace
- Open Access
- 24 June 2025
- Published by Elsevier in Journal of ISAKOS
- Vol. 13, 100918
Arthroscopic remnant preservation anterior cruciate ligament reconstruction using quadrupled semitendinosus autograft with internal brace: A current technique
- 24 June 2025
- Published by Elsevier in Journal of ISAKOS
- Vol. 13, 100918
Open AccessArthroscopic remnant preservation anterior cruciate ligament reconstruction using quadrupled semitendinosus autograft with internal brace: A current technique
- Open Access
- 27 January 2023
- Published by EDP Sciences in SICOT-J
- Vol. 9, 4
A computed tomographic evaluation of femoral and tibial rotational reference axes in total knee arthroplasty
Introduction: The surgical trans epicondylar axis (sTEA) is considered the gold standard for optimum rotation of the femoral component; however, no consensus exists on tibial component positioning. The objectives of this study were to determine the relationship of sTEA to various femoral and tibial reference axes in varus osteoarthritis (OA) knees and (ii) to study the intra-observer and inter-observer variability of the axis relationships. Materials and methods: The study was done on preoperative computerised tomogram (CT) scans of 110 varus knees to assess the rotational relationships respectively of femoral side sTEA with whitesides line (WSL), posterior condylar axis (PCA), clinical trans epicondylar axis (cTEA) and on the tibial side sTEA with posterior tibial margin (PTM), anterior condylar axis (ACA), Akagi’s line and line from the geometric centre of the tibial plateau to 1/3rd tibial tubercle (line GC 1/3rd TT). Results: On the femoral side the mean angles of sTEA with WSL, PCA, cTEA were 95.64° ± 2.85°, 1.77° ± 1.88°, 4.19° ± 0.99° respectively. On the tibial side, the mean angles of sTEA with, PTM, ACA, Akagi’s line, and line GC 1/3rd TT were 1.10° ± 4.69°, 11.98° ± 4.51°, 2.43° ± 4.35°, 16.04° ± 5.93° respectively. Conclusion: Contrary to the generalization, TEA has variable relationships. The surgical trans epicondylar axis was not at the assumed 3° of external rotation to PCA in 85% of knees, nor perpendicular to WSL in >95% of knees. Of the four tibial axes, Akagi’s line was the least variable with sTEA. Furthermore, surgeons should also be aware of the multiple reference axes and the range of deviation from sTEA to optimize the rotational alignment of components.
- 27 January 2023
- Published by EDP Sciences in SICOT-J
- Vol. 9, 4
Open AccessA computed tomographic evaluation of femoral and tibial rotational reference axes in total knee arthroplasty
Introduction: The surgical trans epicondylar axis (sTEA) is considered the gold standard for optimum rotation of the femoral component; however, no consensus exists on tibial component positioning. The objectives of this study were to determine the relationship of sTEA to various femoral and tibial reference axes in varus osteoarthritis (OA) knees and (ii) to study the intra-observer and inter-observer variability of the axis relationships. Materials and methods: The study was done on preoperative computerised tomogram (CT) scans of 110 varus knees to assess the rotational relationships respectively of femoral side sTEA with whitesides line (WSL), posterior condylar axis (PCA), clinical trans epicondylar axis (cTEA) and on the tibial side sTEA with posterior tibial margin (PTM), anterior condylar axis (ACA), Akagi’s line and line from the geometric centre of the tibial plateau to 1/3rd tibial tubercle (line GC 1/3rd TT). Results: On the femoral side the mean angles of sTEA with WSL, PCA, cTEA were 95.64° ± 2.85°, 1.77° ± 1.88°, 4.19° ± 0.99° respectively. On the tibial side, the mean angles of sTEA with, PTM, ACA, Akagi’s line, and line GC 1/3rd TT were 1.10° ± 4.69°, 11.98° ± 4.51°, 2.43° ± 4.35°, 16.04° ± 5.93° respectively. Conclusion: Contrary to the generalization, TEA has variable relationships. The surgical trans epicondylar axis was not at the assumed 3° of external rotation to PCA in 85% of knees, nor perpendicular to WSL in >95% of knees. Of the four tibial axes, Akagi’s line was the least variable with sTEA. Furthermore, surgeons should also be aware of the multiple reference axes and the range of deviation from sTEA to optimize the rotational alignment of components.
- 12 November 2021
- Published by Springer Nature in Indian Journal of Orthopaedics
- Vol. 56 (4) , 655-663
Short-Term Outcomes of Robotic Lateral Unicompartmental Knee Arthroplasty: An Indian Perspective
Background Lateral UKA is a technically more challenging procedure than medial UKA accounting for < 1% of all knee arthroplasties. Robotic UKA for lateral compartment arthritis is rare and has not been reported in India. Materials and Methods This is a prospective single-centre clinical study of six patients (five females and one male) who underwent robotic-arm-assisted lateral UKA (RALUKA) between May 2018 and January 2020 with patient-specific 3D-CT preoperative plan. Overall satisfaction on a five-level Likert scale, clinical outcome based on the KOOS and MFJS and radiological outcomes based on the HKA axis, femorotibial angle (FTA), tibial posterior slope (PS) obtained were compared preoperatively and postoperatively. Results At a mean follow-up period of 23.84 months, among six patients 33.3% very satisfied, 50% satisfied and 16.7% felt neutral. The mean KOOS changed from 63.03 ± 3.52 to 93.95 ± 3.25 and the mean MFJS was 75.41 ± 10.29 postoperatively. The mean HKA axis changed from 175.81° ± 2.88 valgus to 179.99° ± 2.14 neutral alignment. The mean correction attained was from 4.19° ± 2.88 valgus deformity to 0.01° ± 2.14. The mean FTA and the mean PS changed from 7.34° ± 4.14 of valgus to 1.92° ± 1.85 of valgus and 83.44° ± 1.77 to 85.38° ± 2.10, respectively. Conclusions The mean preoperative and postoperative KOOS showed a statistical significance with a p value of < 0.001 (< 0.05), showing significant improvement with RALUKA. RALUKA is a promising surgical option for lateral compartment OA of the knee.
- 12 November 2021
- Published by Springer Nature in Indian Journal of Orthopaedics
- Vol. 56 (4) , 655-663
Short-Term Outcomes of Robotic Lateral Unicompartmental Knee Arthroplasty: An Indian Perspective
Background Lateral UKA is a technically more challenging procedure than medial UKA accounting for < 1% of all knee arthroplasties. Robotic UKA for lateral compartment arthritis is rare and has not been reported in India. Materials and Methods This is a prospective single-centre clinical study of six patients (five females and one male) who underwent robotic-arm-assisted lateral UKA (RALUKA) between May 2018 and January 2020 with patient-specific 3D-CT preoperative plan. Overall satisfaction on a five-level Likert scale, clinical outcome based on the KOOS and MFJS and radiological outcomes based on the HKA axis, femorotibial angle (FTA), tibial posterior slope (PS) obtained were compared preoperatively and postoperatively. Results At a mean follow-up period of 23.84 months, among six patients 33.3% very satisfied, 50% satisfied and 16.7% felt neutral. The mean KOOS changed from 63.03 ± 3.52 to 93.95 ± 3.25 and the mean MFJS was 75.41 ± 10.29 postoperatively. The mean HKA axis changed from 175.81° ± 2.88 valgus to 179.99° ± 2.14 neutral alignment. The mean correction attained was from 4.19° ± 2.88 valgus deformity to 0.01° ± 2.14. The mean FTA and the mean PS changed from 7.34° ± 4.14 of valgus to 1.92° ± 1.85 of valgus and 83.44° ± 1.77 to 85.38° ± 2.10, respectively. Conclusions The mean preoperative and postoperative KOOS showed a statistical significance with a p value of < 0.001 (< 0.05), showing significant improvement with RALUKA. RALUKA is a promising surgical option for lateral compartment OA of the knee.