Latest Publications

  • Online Error Inversion-Based Assessment of the Internal Insulation Performance of a Capacitor Voltage Transformer

    by Zhu Zhang, Heng Lu, Binbin Li, Shaorui Qin, Lijian Ding

    The internal insulation parameters of capacitor voltage transformers (CVTs) are susceptible to the influence of environment and aging during operation, which leads to the degradation of its insulation performance and affects the safe and stable operation of power system. Since the current insulation testing method is essentially a periodic testing of power outage, which has the problems of difficulty of power outage and untimely testing, this article proposes an online assessment method of CVT internal insulation performance based on error inversion. This method innovatively takes the measurement error of CVT as a characteristic parameter to characterize the insulation state of CVT, establishes a feature set of insulation state composed of specific and angular differences, and then uses a convolutional neural network (CNN) and fuzzy analysis to form a data-knowledge double-layer-driven online assessment model of CVT’s internal insulation performance. The experimental results show that the proposed method has an accuracy of 99.76% for the identification of typical internal insulation states, and the average error of quantitative evaluation of internal insulation parameters is better than 3%, which effectively realizes the online evaluation of CVT internal insulation parameters.


  • Improving the sensitivity of a PCB Rogowski coil current sensor with split-plate summation

    by Zhang Zhu, Wang Tenghui, Li Binbin, Qin Shaorui, Ding Lijian

    As a promising current sensor for high-frequency pulsed current monitoring, printed circuit board (PCB) Rogowski coils demonstrate distinct advantages, including extended bandwidth capability and inherent immunity to magnetic saturation. However, their practical implementation is constrained by an intrinsic trade-off between bandwidth optimization and sensitivity enhancement. To address this challenge, a high-sensitivity, wide-bandwidth current sensor is designed in this paper. Through analysis of the PCB Rogowski coil structure and the distribution parameter model of the coil, an optimal sampling resistance value is selected, and a new type of second-order RC integration circuit is designed. In addition, the effects of integrating resistance, integrating capacitance, the number of turns in the coil, the thickness of the PCB, and the inner and outer diameters of the coil on the operating bandwidth and sensitivity of the sensor are analyzed and investigated to determine the optimal parameters of PCB Rogowski coils and provide a basis for the selection of coil parameters. Finally, a multi-PCB Rogowski coil split-board output method is proposed to improve the sensitivity and measurement accuracy of the sensor while keeping its operating bandwidth unchanged. Simulation and experimental test results show that the multi-PCB Rogowski coil split-board output method can improve the sensitivity and measurement accuracy of the sensor while keeping its operating bandwidth constant.


  • Harmonic Measurement Method and System Design Based on Self-Compensating FFT

    by Zhu Zhang, Shuailong Lu, Shaorui Qin, Binbin Li, Lijian Ding

    Harmonics in power systems not only affect the operational efficiency of equipment but also have the potential to cause system failures and stability issues. Therefore, accurate measurements and analyses of harmonics are of great significance. The conventional fast Fourier transform (FFT) is widely used for harmonic analysis; however, its performance can be affected by issues such as spectral leakage and the fence effect. These issues can result in significant errors in frequency and amplitude estimation, often failing to meet the requirements for high-precision signal processing. To address this challenge, this study proposes a harmonic analysis method based on the self-compensating FFT. After signal preprocessing steps such as windowing and zero-padding, the self-compensating FFT integrates frequency and amplitude correction into a unified framework. It first estimates the frequency deviation using a three-point interpolation method based on the energy distribution of adjacent spectral peaks, and then constructs a data-driven amplitude correction model based on the updated frequency - amplitude relationship. This method improves harmonic analysis accuracy by optimizing frequency and amplitude corrections in tandem, effectively eliminating frequency offset and amplitude errors inherent in the conventional FFT. Experimental results demonstrate that compared to conventional FFT, the self-compensating FFT reduces errors in frequency and amplitude estimation by 99.6%-99.8% and 95%-98%, respectively. These findings demonstrate the significant optimization performance of the proposed method.


  • Research on Self-Detection Method of Current Transformer Measurement Error Based on Data Secondary Correction

    by Zhu Zhang, Chang Rui, Binbin Li, Shaorui Qin, Lijian Ding

    The current transformer is a critical sensing device for real-time monitoring of power system operations. However, its performance can degrade over time, leading to measurement errors that compromise accurate detection of primary signals. Traditional error detection methods rely on periodic comparisons with standard current transformers under live or offline conditions, which lack real-time responsiveness. To address this limitation, this paper proposes an online self-detection method for current transformer measurement errors based on secondary data correction. The proposed method consists of three main steps: (1) using affine transformation to correct synchronous three-phase current data from nodes, establishing a new correlation-constrained comparison standard; (2) extracting residual components containing error information via the empirical wavelet transform-auto-regressive moving average method, followed by a secondary correction to enhance error features; and (3) dynamically evaluating the corrected data using an improved moving window principal component analysis approach. This framework enables long-term, real-time error self-detection. Experimental results from field data demonstrate that the method achieves a minimum detectable error that meets the 0.2 accuracy requirement.

  • Online Detection Method for Capacitor Voltage Transformer Measurement Error Adapted to Nonstationary Random Processes

    by Zhu Zhang, Heng Lu, Binbin Li, Shaorui Qin, Lijian Ding

    Capacitor Voltage Transformers (CVTs) are measurement devices widely used in high-voltage power grids, and the long-term stability of their measurement errors affects the safe operation of power systems. To address the problem of insufficient real-time periodic calibration using standard transformers, this paper proposes an online detection method for CVT measurement error based on enhanced integrated principal component analysis (EIPCA). Considering that the secondary output voltage of CVTs is characterized by a non-stationary random distribution, the method combines the advantages of principal component analysis (PCA) and Kernel Principal Component Analysis (KPCA) to enhance its ability to process mixed linear and nonlinear data. It performs variational mode decomposition (VMD) of the linear residuals mapped in the cascade process to eliminate the modeling error caused by non-stationary data. Finally, the residual component characterizing the integrated error information of the CVT is separated from the primary voltage fluctuation, and the T 2 statistic is established as the index of measurement error detection. The experimental results show that the EIPCA-based online error detection method proposed in this paper can effectively detect the 0.2-level error of the CVT, significantly improving detection performance compared with traditional PCA.


  • Research on Data-Driven Self-Diagnosis for Measurement Errors in Capacitor Voltage Transformers

    by Zhu Zhang, Heng Lu, Binbin Li, Lijian Ding

    Capacitor voltage transformers (CVTs) are widely used in high-voltage power systems. Their main problem is poor stability in measurement errors. The existing approach of utilizing standard voltage transformers for regular offline error calibration is insufficient in real-time and cannot meet the requirements of intelligent substations for online operations monitoring of key equipment. Therein, this paper proposes a data-driven self-diagnosis method based on metering errors of operational CVTs. This method synchronously collects the secondary signals of three-phase CVT outputs. Firstly, under the rigid constraints of three-phase symmetrical power system operations, the residual subspace parameters that characterize the measurement errors are extracted using principal component analysis (PCA). Then, bilateral threshold detection is combined with a multi-dimensional comprehensive assessment to determine the boundary conditions of the abnormal overall error state of the three-phase CVT and its deterioration direction. Finally, the coded multi-dimensional detection results are input into the learning vector quantized (LVQ) classifier to rapidly diagnose CVT measurement error deterioration. The experimental results show that the proposed method effectively identifies error fluctuations at 0.02% with a detection accuracy for the CVT amplitude error overshoot reaching 0.1%. The method can accurately locate the faulty phases and direction of error deterioration in real-time, realizing the demand for self-diagnosing for CVT metrological errors at the 0.2-level.


  • Self-detection method for measurement error of capacitor voltage transformer considering conversion error

    by Zhang Zhu, Lu Heng, Li Binbin

    The measurement error of capacitor voltage transformers (CVTs) has poor stability under the complex environment of substations. Conventionally, error detection is performed by regularly comparing the output of standard transformers, which lacks real-time performance. Moreover, CVTs are prone to operating in an out-of-tolerance state. Thus, this study first analyzes the basic principle of the CVT measurement error self-detection method based on principal component analysis under the constraints of three-phase symmetrical operating characteristics of a power system. Then, the impact of the signal conversion error of analog-to-digital conversion equipment on the self-detection results of CVT measurement errors in engineering applications is analyzed, and a multi-layer wavelet analysis signal denoising method is proposed to enhance the self-detection ability of CVT measurement errors. Finally, simulations show that the proposed method can identify an error change of 0.1%, meeting the self-detection requirements for the measurement error at 0.2 class.


  • Open Access

    Research on adaptive state prediction method for the metering error of capacitor voltage transformer

    by Zhang Zhu, Li Binbin, Xue Jianyi, Ding Lijian

    A capacitor voltage transformer (CVT) is widely used in high voltage power systems because of its good insulation performance. However, the structure of CVT is more complex and the stability of its metering error is poor, which easily causes the loss of power metering. The conventional evaluation method for the metering error of CVT is to compare and calibrate with a standard transformer under off-line condition in a fixed period. Because of the long evaluation period, it is impossible to accurately predict the state change of CVT metering error, which is of more significance practically. To solve this problem, this paper proposes an adaptive state prediction method: Analyze the measurement data of CVT using principal component analysis method under the constraint of electrical physical relationship, the metering of CVT is mapped to residual and score (CRS) statistic. For this way, the self-evaluation of CVT metering error in real-time is realized without a standard transformer to get the high frequency time series of error data. According to the measurement data of CVT in process, the CRS statistics are batch processed adaptively, and the prediction model of CRS statistics is established based on the time series analysis. Experiments show that the method can accurately predict the state change of CVT metering error, and the prediction error is better than 15%. It is helpful to promote the development of CVT metering error detection into on-demand detection.

  • Self-Detecting the Measurement Error of Electronic Voltage Transformer Based on Principal Component Analysis-Wavelet Packet Decomposition

    by Binbin Li, Zhu Zhang, Lijian Ding

    The poor long-term stability of measurement error is the main problem in the operation of an electronic voltage transformer (EVT). Prevalent methods of error detection involve calibrating it regularly with a standard voltage transformer, but this is not conducive to the timely detection of the degradation in the error of the EVT. In light of this, this article proposes a method to self-detect error based on principal component analysis-wavelet packet decomposition (PCA-WPD). A standard of comparison for error detection is first established based on the characteristics of three-phase symmetrical operation. PCA is then applied to the measurement data of the three-phase EVTs, and their error is mapped to the online process monitoring of squared prediction error (SPE) statistics. Furthermore, the SPE statistics are decomposed by a three-level wavelet packet to eliminate the influence of the time-varying characteristics of node imbalance on the results of detection. The results of experiments show that the proposed method can detect the measurement error with an accuracy of 0.2 class without a standard.