Chen Ma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chen Ma has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Aibing Qiu
School of Electrical Engineering and Automation, Nantong University, Nantong, China
2 shared publications - Cheng Chen
School of Electrical and Information Engineering, Jiangsu University, Zhenjiang, China
1 shared publication - Guoping Lu
Nantong University
1 shared publication - He Liao
Shanghai Institute of Satellite Engineering, No. 3666, Yuanjiang Road, Shanghai 201109, China
1 shared publication - Jinjin Xie
College of Instrument Science and Engineering, Southeast University, Nanjing, China
1 shared publication - Jinpeng Zhu
School of Electrical Engineering and Automation, Nantong University, Nantong, China
1 shared publication
Latest Publications
- 16 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Optimal Decentralized Observer for State Estimation and Concurrent Fault Diagnosis of DC Microgrid
As for distributed interconnected systems such as DC microgrid, the centralized and distributed monitoring schemes are up against of high communication consumption and the risk of cyber-attack. In this article, an optimal decentralized observer (ODO) design scheme is developed for DC microgrid subject to unknown load disturbance, process, and measurement noises. The proposed scheme requires no information exchange among local observers, and thus greatly reduces the communication consumption and the risk of cyber-attack. To be specific, considering that the column full rank condition of conventional unknown input decouple method no longer holds for the subsystem of DC microgrid, a so-called pseudo-unknown input is constructed with the help of full rank decomposition (FRD) technique to design the local unknown input observer (UIO), which can decouple not only from the local unknown loads but also from the states of adjacent subsystems. Then, some design freedoms in the UIO are further exploited, along with the pseudo-unknown input estimation by the smoothing technique, to achieve the optimal state estimation of the local subsystem in the sense of minimum mean-squared error sense. The proposed ODO provides an excellent robustness to both the unknown loads and system noises by combining the advantages of UIO and Kalman filter (KF). In addition, as the local ODO is decoupled from the neighbor system, the local residual generation and evaluation scheme are accordingly presented to realize concurrent fault diagnosis. A DC microgrid composed of six distributed generation units (DGUs) is finally used to demonstrate the effectiveness and superiority of the proposed scheme.
- 16 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Optimal Decentralized Observer for State Estimation and Concurrent Fault Diagnosis of DC Microgrid
As for distributed interconnected systems such as DC microgrid, the centralized and distributed monitoring schemes are up against of high communication consumption and the risk of cyber-attack. In this article, an optimal decentralized observer (ODO) design scheme is developed for DC microgrid subject to unknown load disturbance, process, and measurement noises. The proposed scheme requires no information exchange among local observers, and thus greatly reduces the communication consumption and the risk of cyber-attack. To be specific, considering that the column full rank condition of conventional unknown input decouple method no longer holds for the subsystem of DC microgrid, a so-called pseudo-unknown input is constructed with the help of full rank decomposition (FRD) technique to design the local unknown input observer (UIO), which can decouple not only from the local unknown loads but also from the states of adjacent subsystems. Then, some design freedoms in the UIO are further exploited, along with the pseudo-unknown input estimation by the smoothing technique, to achieve the optimal state estimation of the local subsystem in the sense of minimum mean-squared error sense. The proposed ODO provides an excellent robustness to both the unknown loads and system noises by combining the advantages of UIO and Kalman filter (KF). In addition, as the local ODO is decoupled from the neighbor system, the local residual generation and evaluation scheme are accordingly presented to realize concurrent fault diagnosis. A DC microgrid composed of six distributed generation units (DGUs) is finally used to demonstrate the effectiveness and superiority of the proposed scheme.
- Open Access
- 2 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 149050-149066
Fault Detection and Identification Based on Explicit Polynomial Mapping and Combined Statistic in Nonlinear Dynamic Processes
Single traditional multivariate statistical monitoring methods, such as principal component analysis (PCA) and canonical variate analysis (CVA), are less effective in nonlinear dynamic processes. Monitoring approaches based on radial basis kernel function have been intensively applied. However, an infinite dimension nonlinear mapping is redundant and inefficient. To improve the efficiency of traditional methods and consider the nonlinearity and dynamics simultaneously, this paper proposes canonical variate nonlinear principal component analysis (CV-NPCA) based on explicit polynomial mapping and combined statistic for detecting and identifying faults in nonlinear dynamic processes. There are two main contributions of the proposed method. First, explicit second-order polynomial mapping is introduced to combine CVA with PCA to simultaneously decrease the adverse effects of nonlinearity and dynamics. Second, the $Q_{c}$ statistic combining residual vectors with residual components is proposed, and a two-dimensional (2D) contribution plot and the variable with the largest contribution based on the $Q_{c}$ statistic are given for fault identification in the simulation study. Compared with the results of PCA, CVA, kernel principal component analysis (KPCA), nonlinear dynamic principal component analysis (NDPCA) and kernel entropy component analysis (KECA), the proposed method not only has relatively higher fault detection rates and identification rates but also has lower false alarm rates in the numerical simulation process and the benchmark Tennessee Eastman process.
- 2 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 149050-149066
Open AccessFault Detection and Identification Based on Explicit Polynomial Mapping and Combined Statistic in Nonlinear Dynamic Processes
Single traditional multivariate statistical monitoring methods, such as principal component analysis (PCA) and canonical variate analysis (CVA), are less effective in nonlinear dynamic processes. Monitoring approaches based on radial basis kernel function have been intensively applied. However, an infinite dimension nonlinear mapping is redundant and inefficient. To improve the efficiency of traditional methods and consider the nonlinearity and dynamics simultaneously, this paper proposes canonical variate nonlinear principal component analysis (CV-NPCA) based on explicit polynomial mapping and combined statistic for detecting and identifying faults in nonlinear dynamic processes. There are two main contributions of the proposed method. First, explicit second-order polynomial mapping is introduced to combine CVA with PCA to simultaneously decrease the adverse effects of nonlinearity and dynamics. Second, the $Q_{c}$ statistic combining residual vectors with residual components is proposed, and a two-dimensional (2D) contribution plot and the variable with the largest contribution based on the $Q_{c}$ statistic are given for fault identification in the simulation study. Compared with the results of PCA, CVA, kernel principal component analysis (KPCA), nonlinear dynamic principal component analysis (NDPCA) and kernel entropy component analysis (KECA), the proposed method not only has relatively higher fault detection rates and identification rates but also has lower false alarm rates in the numerical simulation process and the benchmark Tennessee Eastman process.
- 30 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 22 (5) , 2111-2120
Improving Dynamic Response of AMB Systems in Control Moment Gyros Based on a Modified Integral Feedforward Method
During the gimbal maneuvering, the dynamic characteristics of the active magnetic bearing (AMB) rotor system is an important concern for the applications of the magnetically suspended double-gimbal control moment gyro (MSDGCMG). Both the static torques caused by the gimbal motions and the dynamic torques by the rotor twisting motion will have an impact on the dynamic performance of the magnetically suspended high-speed rotor. This paper explores a modified current integral feedforward (CIF) control scheme to improve its dynamic response. Using a dynamic regulator, the CIF method is applied to supply the static torque by the permanent magnets and simultaneously improve the stability margin of the AMB-rotor system. Then the multiple compensation method is proposed to compensate the dynamic torque to further improve the response speed. The influence of rotor tilting on output torque precision of MSDGCMG is also analyzed. Finally, the experimental results on a developed MSDGCMG prototype validate the effectiveness of the proposed method. The modified CIF combined with dynamic torque compensation resulted in a step response settling time of 0.13 seconds as compared to the traditional method with a settling time of 2.5 seconds.
- 30 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 22 (5) , 2111-2120
Improving Dynamic Response of AMB Systems in Control Moment Gyros Based on a Modified Integral Feedforward Method
During the gimbal maneuvering, the dynamic characteristics of the active magnetic bearing (AMB) rotor system is an important concern for the applications of the magnetically suspended double-gimbal control moment gyro (MSDGCMG). Both the static torques caused by the gimbal motions and the dynamic torques by the rotor twisting motion will have an impact on the dynamic performance of the magnetically suspended high-speed rotor. This paper explores a modified current integral feedforward (CIF) control scheme to improve its dynamic response. Using a dynamic regulator, the CIF method is applied to supply the static torque by the permanent magnets and simultaneously improve the stability margin of the AMB-rotor system. Then the multiple compensation method is proposed to compensate the dynamic torque to further improve the response speed. The influence of rotor tilting on output torque precision of MSDGCMG is also analyzed. Finally, the experimental results on a developed MSDGCMG prototype validate the effectiveness of the proposed method. The modified CIF combined with dynamic torque compensation resulted in a step response settling time of 0.13 seconds as compared to the traditional method with a settling time of 2.5 seconds.