Pau Alonso
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Pau Alonso has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Ana Andrés
Servicio de Cardiología, Hospital Universitario y Politécnico La Fe, Valencia, Spain
4 shared publicationsAntonio Salvador
Servicio de Cardiología, Hospital Universitario y Politécnico La Fe, Valencia, Spain
2 shared publicationsBegoña Igual
ERESA, Hospital Universitario y Politécnico La Fe, Valencia, Spain
2 shared publications- Joaquín Osca
Hospital Universitario y Politecnico La Fe , Valencia
2 shared publications - Óscar Cano
Hospital Universitari i Politecnic La Fe
2 shared publications - Ana Osa
Cardiology Department, Hospital Universitari i Politècnic La Fe, 46026 Valencia, Spain
1 shared publication
Latest Publications
- 1 May 2015
- Published by Elsevier in Revista Española de Cardiología (English Edition)
- Vol. 68 (5) , 390-397
Value of the Electrocardiogram as a Predictor of Right Ventricular Dysfunction in Patients With Chronic Right Ventricular Volume Overload
- 1 May 2015
- Published by Elsevier in Revista Española de Cardiología (English Edition)
- Vol. 68 (5) , 390-397
Value of the Electrocardiogram as a Predictor of Right Ventricular Dysfunction in Patients With Chronic Right Ventricular Volume Overload
- 9 December 2014
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 38 (3) , 326-333
The Use of Quadripolar Left Ventricular Leads Improves the Hemodynamic Response to Cardiac Resynchronization Therapy
Background: The objective of the present study was to evaluate the usefulness of a left ventricle (LV) quadripolar lead in improving the hemodynamic response to cardiac resynchronization therapy (CRT).Methods and Results: We included 27 consecutive patients implanted with a CRT device with an LV quadripolar lead. Hemodynamic parameters were evaluated at 3‐month follow‐up by using impedance cardiography. We assessed the highest cardiac output and the highest stroke volume (SV) obtained after atrioventricular and interventricular optimization with pacing from each of the four electrodes of the LV lead. Each patient was evaluated according to three different pacing configurations: unipolar‐simulated, bipolar, and quadripolar. Biventricular pacing improved hemodynamics in comparison to the nonpaced measurements: cardiac index (CI): 2.69 L/min/m2 versus 2.17 L/min/m2 (P = 0.001). The hemodynamic response was highest in the quadripolar in comparison to unipolar‐simulated and bipolar configurations, with an increase of 29%, 23%, and 27%, respectively, in relation to the reference CI and with an increase of 22%, 11%, and 18%, respectively, in relation to the reference indexed SV (P < 0.05, for the comparison between unipolar‐simulated and quadripolar configurations). Twelve patients (44%) showed the best hemodynamic response by pacing from any of the two distal electrodes and 15 patients (56%) by pacing from the two proximal electrodes. Finally, CRT responder rates were higher in quadripolar versus bipolar and unipolar‐simulated configurations: 90%, 85%, and 75%, respectively.Conclusions: The quadripolar LV lead was associated with a better hemodynamic response and higher CRT responder rates when compared with unipolar‐simulated and bipolar LV leads.
- 9 December 2014
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 38 (3) , 326-333
The Use of Quadripolar Left Ventricular Leads Improves the Hemodynamic Response to Cardiac Resynchronization Therapy
Background: The objective of the present study was to evaluate the usefulness of a left ventricle (LV) quadripolar lead in improving the hemodynamic response to cardiac resynchronization therapy (CRT).Methods and Results: We included 27 consecutive patients implanted with a CRT device with an LV quadripolar lead. Hemodynamic parameters were evaluated at 3‐month follow‐up by using impedance cardiography. We assessed the highest cardiac output and the highest stroke volume (SV) obtained after atrioventricular and interventricular optimization with pacing from each of the four electrodes of the LV lead. Each patient was evaluated according to three different pacing configurations: unipolar‐simulated, bipolar, and quadripolar. Biventricular pacing improved hemodynamics in comparison to the nonpaced measurements: cardiac index (CI): 2.69 L/min/m2 versus 2.17 L/min/m2 (P = 0.001). The hemodynamic response was highest in the quadripolar in comparison to unipolar‐simulated and bipolar configurations, with an increase of 29%, 23%, and 27%, respectively, in relation to the reference CI and with an increase of 22%, 11%, and 18%, respectively, in relation to the reference indexed SV (P < 0.05, for the comparison between unipolar‐simulated and quadripolar configurations). Twelve patients (44%) showed the best hemodynamic response by pacing from any of the two distal electrodes and 15 patients (56%) by pacing from the two proximal electrodes. Finally, CRT responder rates were higher in quadripolar versus bipolar and unipolar‐simulated configurations: 90%, 85%, and 75%, respectively.Conclusions: The quadripolar LV lead was associated with a better hemodynamic response and higher CRT responder rates when compared with unipolar‐simulated and bipolar LV leads.
- 1 October 2014
- Published by Elsevier in Revista Española de Cardiología (English Edition)
- Vol. 67 (10) , 859-861
Improvement in Hemodynamics and Contractility With Multipoint Left Ventricular Pacing in Cardiac Resynchronization Therapy
- 1 October 2014
- Published by Elsevier in Revista Española de Cardiología (English Edition)
- Vol. 67 (10) , 859-861
Improvement in Hemodynamics and Contractility With Multipoint Left Ventricular Pacing in Cardiac Resynchronization Therapy
- 1 March 2014
- Published by Elsevier in International Journal of Cardiology
- Vol. 172 (1) , e218-e219
Diagnostic power of echocardiographic speckle tracking of the tricuspid annular motion to assess right ventricular dysfunction
- 1 March 2014
- Published by Elsevier in International Journal of Cardiology
- Vol. 172 (1) , e218-e219
Diagnostic power of echocardiographic speckle tracking of the tricuspid annular motion to assess right ventricular dysfunction