Huthaifa Atallah
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Huthaifa Atallah has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Bálint Molics
Department of Sport Physiotherapy, Faculty of Health Sciences, University of Pécs, Pécs, Hungary
7 shared publications - Mahmoud Alfatafta
Department of Prosthetics and Orthotics, School of Rehabilitation Sciences, The University of Jordan, Amman 11942, Jordan
7 shared publications Amneh Alshawabka
Department of Prosthetics and Orthotics, School of Rehabilitation Sciences, The University of Jordan, Amman, 11942, Jordan
5 shared publications- Amneh Alshawabka
Department of Prosthetics and Orthotics, School of Rehabilitation Sciences, The University of Jordan, Amman 11942, Jordan
5 shared publications - Anthony McGarry
Biomedical Engineering Department, University of Strathclyde, Glasgow G4 0NW, UK
5 shared publications Anthony McGarry
Biomedical Engineering Department, University of Strathclyde, Glasgow, UK
4 shared publications
Latest Publications
- Open Access
- 5 November 2026
- Published by Springer Nature in BMC Medical Education
Career choice factors and critical thinking dispositions among undergraduate prosthetics and orthotics students: a cross-sectional survey
Background: A global shortage of healthcare professionals highlights the requirement for an educated workforce in the prosthetics and orthotics (P&O) field. Critical thinking (CT) dispositions are paramount for P&O students, who deal with complex clinical scenarios while providing evidence-based care. Yet, few studies examine the career choice motivators and the development in critical thinking. Aim: To explore the incentives and barriers to candidates when selecting P&O as an undergraduate course and to evaluate the development of critical thinking (CT) dispositions of students as they progress through their undergraduate prosthetics and orthotics (P&O) degree. Study design: A cross-sectional study. Methods: A total of 252 undergraduate P&O students completed a structured survey consisting of two parts: [1] career choice decision including demographics, motivations, and perceived barriers; and [2] CT dispositions using the California Critical Thinking Disposition Inventory (CCTDI). Results: The female-to-male ratio of students was 3.6:1, with most deciding to pursue the P&O profession during secondary education. Helping others and improving patients’ quality of life were key motivators, while limited awareness of the profession was the most cited barrier. Students frequently identified independent research as a major influence in their final decision to apply for the degree. CT dispositions showed a positive tendency, with a mean total score of 329 out of 420. Significant differences in CT skill development were observed across year of study ( p = 0.001) and age ( p = 0.003). Conclusion: Findings emphasize the importance of increased early awareness of the P&O profession. A general positive tendency of development of CT dispositions was observed among P&O students, with improvement in their CT dispositions as they progressed through academic years.
- 5 November 2026
- Published by Springer Nature in BMC Medical Education
Open AccessCareer choice factors and critical thinking dispositions among undergraduate prosthetics and orthotics students: a cross-sectional survey
Background: A global shortage of healthcare professionals highlights the requirement for an educated workforce in the prosthetics and orthotics (P&O) field. Critical thinking (CT) dispositions are paramount for P&O students, who deal with complex clinical scenarios while providing evidence-based care. Yet, few studies examine the career choice motivators and the development in critical thinking. Aim: To explore the incentives and barriers to candidates when selecting P&O as an undergraduate course and to evaluate the development of critical thinking (CT) dispositions of students as they progress through their undergraduate prosthetics and orthotics (P&O) degree. Study design: A cross-sectional study. Methods: A total of 252 undergraduate P&O students completed a structured survey consisting of two parts: [1] career choice decision including demographics, motivations, and perceived barriers; and [2] CT dispositions using the California Critical Thinking Disposition Inventory (CCTDI). Results: The female-to-male ratio of students was 3.6:1, with most deciding to pursue the P&O profession during secondary education. Helping others and improving patients’ quality of life were key motivators, while limited awareness of the profession was the most cited barrier. Students frequently identified independent research as a major influence in their final decision to apply for the degree. CT dispositions showed a positive tendency, with a mean total score of 329 out of 420. Significant differences in CT skill development were observed across year of study ( p = 0.001) and age ( p = 0.003). Conclusion: Findings emphasize the importance of increased early awareness of the P&O profession. A general positive tendency of development of CT dispositions was observed among P&O students, with improvement in their CT dispositions as they progressed through academic years.
- Open Access
- 22 October 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (21) , 3455
Associations Between the Chippaux–Smirak Index and Clinical Foot Assessments in Young Adults: A Cross-Sectional Study
Background/Objectives: The Chippaux–Smirak Index (CSI) measures relative midfoot plantar contact, whereas the six-item Foot Posture Index (FPI-6), navicular drop test (NDT), and resting calcaneal stance position (RCSP) assess static foot posture, change in navicular height, and calcaneal alignment, respectively. This study examined associations among these measures, agreement between CSI and FPI-6 classifications, and measurement reliability in young adults. Methods: This cross-sectional study included 350 young adults, with both feet assessed (700 feet). Two orthotists independently measured CSI, FPI-6, NDT, and RCSP. Generalised estimating equation models accounted for correlations between feet and were adjusted for age, sex, body mass index, and foot side. Agreement was assessed using exact percentage agreement and linear weighted Cohen’s kappa, and reliability using intraclass correlation coefficients (ICCs). Results: After adjustment, each increase of 10 percentage points in CSI was associated with a 2.141-point-higher FPI-6 total score, a 2.660 mm greater navicular drop, and an RCSP that was 3.240° more valgus (all p < 0.001). CSI and grouped FPI-6 classifications agreed for 82.9% of feet (linear weighted κ = 0.664, 95% CI 0.595–0.727). Single-measure interrater ICCs ranged from 0.644 for NDT to 0.884 for CSI. Digital remeasurement of CSI demonstrated excellent intrarater reliability (ICC(A,1) = 0.989). Conclusions: Higher CSI values were associated with a more pronated static foot posture, greater navicular drop, and a more valgus RCSP. Incomplete agreement between CSI and FPI-6 classifications indicates that these methods provide related but distinct information and should be interpreted according to the specific foot characteristic assessed.
- 22 October 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (21) , 3455
Open AccessAssociations Between the Chippaux–Smirak Index and Clinical Foot Assessments in Young Adults: A Cross-Sectional Study
Background/Objectives: The Chippaux–Smirak Index (CSI) measures relative midfoot plantar contact, whereas the six-item Foot Posture Index (FPI-6), navicular drop test (NDT), and resting calcaneal stance position (RCSP) assess static foot posture, change in navicular height, and calcaneal alignment, respectively. This study examined associations among these measures, agreement between CSI and FPI-6 classifications, and measurement reliability in young adults. Methods: This cross-sectional study included 350 young adults, with both feet assessed (700 feet). Two orthotists independently measured CSI, FPI-6, NDT, and RCSP. Generalised estimating equation models accounted for correlations between feet and were adjusted for age, sex, body mass index, and foot side. Agreement was assessed using exact percentage agreement and linear weighted Cohen’s kappa, and reliability using intraclass correlation coefficients (ICCs). Results: After adjustment, each increase of 10 percentage points in CSI was associated with a 2.141-point-higher FPI-6 total score, a 2.660 mm greater navicular drop, and an RCSP that was 3.240° more valgus (all p < 0.001). CSI and grouped FPI-6 classifications agreed for 82.9% of feet (linear weighted κ = 0.664, 95% CI 0.595–0.727). Single-measure interrater ICCs ranged from 0.644 for NDT to 0.884 for CSI. Digital remeasurement of CSI demonstrated excellent intrarater reliability (ICC(A,1) = 0.989). Conclusions: Higher CSI values were associated with a more pronated static foot posture, greater navicular drop, and a more valgus RCSP. Incomplete agreement between CSI and FPI-6 classifications indicates that these methods provide related but distinct information and should be interpreted according to the specific foot characteristic assessed.
- Open Access
- 29 September 2026
- Published by MDPI AG in Healthcare
- Vol. 14 (19) , 3213
Assessing Feasibility and Readiness for 3D Printing Integration in Prosthetics and Orthotics: A Cross-Sectional Study
Introduction: Three-dimensional (3D) printing is an emerging technology with the potential to transform prosthetics and orthotics (P&O) education and clinical practice by enabling faster, more customized, and cost-effective device production. However, its adoption of routine P&O practice remains limited, particularly in the Middle East, and little is known about practitioners’ readiness to implement this technology. Aim: To evaluate the readiness for and acceptance of integrating 3D printing into P&O practice using the Unified Theory of Acceptance and Use of Technology (UTAUT). Methodology: A descriptive cross-sectional study was conducted using a UTAUT-based questionnaire distributed through professional networks and social media. A total of 104 participants, including P&O professionals and final-year P&O students from Jordan, completed the survey. Descriptive statistics and multiple linear regression analyses were performed to identify factors influencing the behavioral intention to adopt 3D printing technology. Results: Most participants were familiar with the concept of 3D printing in P&O (62.5%), whereas only 12.5% reported that their workplace currently uses 3D printing for prosthetic or orthotic design or fabrication. Performance Expectancy (3.38 ± 0.66) and Effort Expectancy (3.40 ± 0.70) received moderately positive ratings, while Facilitating Conditions had the lowest mean score (2.58 ± 0.84), indicating limited organizational readiness. Behavioral Intention was moderate (3.02 ± 0.99). Multiple linear regression analysis showed that Performance Expectancy (β = 0.518, p < 0.001) was the strongest significant predictor of Behavioral Intention, while Facilitating Conditions (β = 0.215, p = 0.008) was also a significant predictor. The model explained 45.5% of the variance in Behavioral Intention (R2 = 0.455). The most frequently reported barriers were limited technical expertise, lack of organizational priority, and inadequate access to 3D printing equipment and materials. Participants identified training in computer-aided design (CAD) and improved access to digital manufacturing technologies as key implementation needs. Conclusions: P&O professionals and students demonstrated positive attitudes toward 3D printing and a willingness to adopt the technology; however, implementation remains constrained by inadequate infrastructure, limited technical support, insufficient training opportunities, and organizational barriers. Strengthening facilitating conditions through investment in digital infrastructure, curriculum integration, workforce training, and institutional support is likely to accelerate the adoption of 3D printing in P&O education and clinical practice.
- 29 September 2026
- Published by MDPI AG in Healthcare
- Vol. 14 (19) , 3213
Open AccessAssessing Feasibility and Readiness for 3D Printing Integration in Prosthetics and Orthotics: A Cross-Sectional Study
Introduction: Three-dimensional (3D) printing is an emerging technology with the potential to transform prosthetics and orthotics (P&O) education and clinical practice by enabling faster, more customized, and cost-effective device production. However, its adoption of routine P&O practice remains limited, particularly in the Middle East, and little is known about practitioners’ readiness to implement this technology. Aim: To evaluate the readiness for and acceptance of integrating 3D printing into P&O practice using the Unified Theory of Acceptance and Use of Technology (UTAUT). Methodology: A descriptive cross-sectional study was conducted using a UTAUT-based questionnaire distributed through professional networks and social media. A total of 104 participants, including P&O professionals and final-year P&O students from Jordan, completed the survey. Descriptive statistics and multiple linear regression analyses were performed to identify factors influencing the behavioral intention to adopt 3D printing technology. Results: Most participants were familiar with the concept of 3D printing in P&O (62.5%), whereas only 12.5% reported that their workplace currently uses 3D printing for prosthetic or orthotic design or fabrication. Performance Expectancy (3.38 ± 0.66) and Effort Expectancy (3.40 ± 0.70) received moderately positive ratings, while Facilitating Conditions had the lowest mean score (2.58 ± 0.84), indicating limited organizational readiness. Behavioral Intention was moderate (3.02 ± 0.99). Multiple linear regression analysis showed that Performance Expectancy (β = 0.518, p < 0.001) was the strongest significant predictor of Behavioral Intention, while Facilitating Conditions (β = 0.215, p = 0.008) was also a significant predictor. The model explained 45.5% of the variance in Behavioral Intention (R2 = 0.455). The most frequently reported barriers were limited technical expertise, lack of organizational priority, and inadequate access to 3D printing equipment and materials. Participants identified training in computer-aided design (CAD) and improved access to digital manufacturing technologies as key implementation needs. Conclusions: P&O professionals and students demonstrated positive attitudes toward 3D printing and a willingness to adopt the technology; however, implementation remains constrained by inadequate infrastructure, limited technical support, insufficient training opportunities, and organizational barriers. Strengthening facilitating conditions through investment in digital infrastructure, curriculum integration, workforce training, and institutional support is likely to accelerate the adoption of 3D printing in P&O education and clinical practice.
- Open Access
- 2 June 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (11) , 4309
A New Method for Measuring Structural Limb-Length Discrepancy: A Quasi-Experimental Study
Background/Objectives: Limb-length discrepancy (LLD) is a relatively common condition, with structural LLD characterized by true shortening of a bony structure. Although various clinical and radiological methods are available, none rely exclusively on position of malleoli relative to one another. This study aims to introduce a novel method for measuring structural LLD using malleoli in conjunction with a ruler. A quasi-experimental study. Methods: Eighteen participants with structural LLD were recruited from an orthopaedic clinic. Each participant underwent four tests: Paired Medial Malleolus Level Test (PMMLT) (new method), measuring tape method (Anterior Superior Iliac Spine (ASIS) to Medial Malleoli (MM), standing-block test, and full-length standing (long bone) radiography. Validity was assessed against radiography. Results: The mean ± SD LLD measured by radiography was 2.99 ± 1.69 cm. Corresponding values were obtained with the PMMLT (2.98 ± 1.69 cm), measuring tape method (2.95 ± 1.66 cm), and the standing-block test (2.92 ± 1.73 cm). No significant differences were found among the methods (χ2(3) = 3.43, p = 0.330). Correlations with radiography were very strong (PMMLT r = 0.996; measuring tape method r = 0.990; standing-block test r = 0.991; all p < 0.001). PMMLT showed negligible bias (−0.01 cm), the narrowest 95% limits of agreement (−0.32 to 0.30 cm), and the lowest RMSE (0.15 cm). Conclusions: The PMMLT demonstrates accuracy and practicality while being simple, cost-effective, and free of radiation exposure, making it a valuable alternative for clinical assessment of LLD in settings where imaging is unavailable or contraindicated.
- 2 June 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (11) , 4309
Open AccessA New Method for Measuring Structural Limb-Length Discrepancy: A Quasi-Experimental Study
Background/Objectives: Limb-length discrepancy (LLD) is a relatively common condition, with structural LLD characterized by true shortening of a bony structure. Although various clinical and radiological methods are available, none rely exclusively on position of malleoli relative to one another. This study aims to introduce a novel method for measuring structural LLD using malleoli in conjunction with a ruler. A quasi-experimental study. Methods: Eighteen participants with structural LLD were recruited from an orthopaedic clinic. Each participant underwent four tests: Paired Medial Malleolus Level Test (PMMLT) (new method), measuring tape method (Anterior Superior Iliac Spine (ASIS) to Medial Malleoli (MM), standing-block test, and full-length standing (long bone) radiography. Validity was assessed against radiography. Results: The mean ± SD LLD measured by radiography was 2.99 ± 1.69 cm. Corresponding values were obtained with the PMMLT (2.98 ± 1.69 cm), measuring tape method (2.95 ± 1.66 cm), and the standing-block test (2.92 ± 1.73 cm). No significant differences were found among the methods (χ2(3) = 3.43, p = 0.330). Correlations with radiography were very strong (PMMLT r = 0.996; measuring tape method r = 0.990; standing-block test r = 0.991; all p < 0.001). PMMLT showed negligible bias (−0.01 cm), the narrowest 95% limits of agreement (−0.32 to 0.30 cm), and the lowest RMSE (0.15 cm). Conclusions: The PMMLT demonstrates accuracy and practicality while being simple, cost-effective, and free of radiation exposure, making it a valuable alternative for clinical assessment of LLD in settings where imaging is unavailable or contraindicated.
- Open Access
- 9 May 2026
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 27 (1)
Assessing lower-limb prosthetic users with the amputee mobility predictor with prosthesis and timed up and go tests
Background: Lower-limb amputation (LLA) significantly impacts mobility, independence, and quality of life. Reliable assessment tools are essential for evaluating functional capacity, guiding prosthetic prescription, and identifying individuals at risk of falls. The Amputee Mobility Predictor with prosthesis (AMPPro) and Timed Up and Go (TUG) test are commonly used performance-based measures, yet their complementary utility in clinical practice among LLA populations in Jordan remains underexplored. Objective: To evaluate functional mobility among lower-limb prosthetic users using AMPPro and TUG, examine associations with demographic and clinical factors, and assess the predictive value of AMPPro for fall risk. Study design: Cross-sectional observational study. Method: Sixty-three adults with unilateral lower-limb amputation were assessed using AMPPro and TUG. Demographic and clinical data, including age, gender, amputation etiology, level, time since amputation, and time since first prosthetic fitting, were collected. Statistical analyses included Spearman correlations, non-parametric tests, and multivariable regression to examine associations and predictors of functional outcomes and fall risk. Results: Participants were predominantly male (71.4%) with a mean age of 43.7 ± 14.5 years. Median AMPPro score was 43/47, and median TUG time was 14 s, with 54% at risk of falls. AMPPro and TUG were strongly inversely correlated (ρ = − 0.603, p < 0.001). Age and amputation cause significantly influenced functional outcomes, while time since amputation, time since first fitting, and amputation level did not. Each one-point increase in AMPPro reduced fall risk by 17% (OR = 0.83, p = 0.004). Conclusion: AMPPro and TUG provide complementary assessments of mobility in lower-limb prosthetic users. AMPPro effectively distinguishes functional levels and predicts fall risk, supporting its use alongside demographic and clinical data for individualized rehabilitation and fall-prevention strategies.
- 9 May 2026
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 27 (1)
Open AccessAssessing lower-limb prosthetic users with the amputee mobility predictor with prosthesis and timed up and go tests
Background: Lower-limb amputation (LLA) significantly impacts mobility, independence, and quality of life. Reliable assessment tools are essential for evaluating functional capacity, guiding prosthetic prescription, and identifying individuals at risk of falls. The Amputee Mobility Predictor with prosthesis (AMPPro) and Timed Up and Go (TUG) test are commonly used performance-based measures, yet their complementary utility in clinical practice among LLA populations in Jordan remains underexplored. Objective: To evaluate functional mobility among lower-limb prosthetic users using AMPPro and TUG, examine associations with demographic and clinical factors, and assess the predictive value of AMPPro for fall risk. Study design: Cross-sectional observational study. Method: Sixty-three adults with unilateral lower-limb amputation were assessed using AMPPro and TUG. Demographic and clinical data, including age, gender, amputation etiology, level, time since amputation, and time since first prosthetic fitting, were collected. Statistical analyses included Spearman correlations, non-parametric tests, and multivariable regression to examine associations and predictors of functional outcomes and fall risk. Results: Participants were predominantly male (71.4%) with a mean age of 43.7 ± 14.5 years. Median AMPPro score was 43/47, and median TUG time was 14 s, with 54% at risk of falls. AMPPro and TUG were strongly inversely correlated (ρ = − 0.603, p < 0.001). Age and amputation cause significantly influenced functional outcomes, while time since amputation, time since first fitting, and amputation level did not. Each one-point increase in AMPPro reduced fall risk by 17% (OR = 0.83, p = 0.004). Conclusion: AMPPro and TUG provide complementary assessments of mobility in lower-limb prosthetic users. AMPPro effectively distinguishes functional levels and predicts fall risk, supporting its use alongside demographic and clinical data for individualized rehabilitation and fall-prevention strategies.
- Open Access
- 9 April 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (8) , 2846
Awareness, Framework-Based Proficiency, and Clinical Implementation of Ankle Foot Orthosis–Footwear Combination (AFO–FC) Tuning: A Cross-Sectional Survey
Background: Ankle foot orthosis–footwear combination (AFO–FC) tuning involves structured adjustment of the AFO relative to footwear to optimise shank alignment and ground reaction force (GRF) positioning during stance. Although established biomechanical frameworks and clinical algorithms are available, variability in clinical implementation persists. Previous investigations have primarily relied on self-reported practice within single healthcare settings and have not, to our knowledge, systematically examined how orthotists articulate and apply tuning principles within structured clinical reasoning across diverse educational and practice environments. Objectives: This study aimed to determine the level of awareness and framework-based proficiency in AFO–FC tuning among practising orthotists in a geographically diverse convenience sample, to examine the extent to which AFO–FC tuning is integrated into routine clinical practice, and to explore associations between framework-based proficiency level and selected professional characteristics. Methods: A cross-sectional study was conducted using an online survey of practising orthotists (n = 245). Awareness of AFO–FC tuning and self-reported routine implementation were assessed. Framework-based proficiency was evaluated among respondents reporting awareness (n = 212) using structured content analysis of open-text responses within a predefined exploratory five-domain biomechanical framework, and classified as limited (0–1 domains), partial (2–3 domains), or full (4–5 domains). Associations between framework-based proficiency level and professional characteristics were examined using chi-square tests. Binary logistic regression was performed to assess the association between framework-based proficiency level and self-reported routine implementation. Results: Self-reported awareness of AFO–FC tuning was high (86.5%), whereas 53.5% reported routine implementation. Based on the framework scoring, 59.0% demonstrated limited framework-based proficiency, 31.6% partial framework-based proficiency, and 9.4% full framework-based proficiency. No statistically significant associations were observed in this sample between framework-based proficiency level and educational qualification, years of clinical experience, or annual AFO case volume (p > 0.05). Full framework-based proficiency was associated with higher odds of self-reported routine implementation (OR = 4.03, 95% CI 1.44–11.25, p = 0.008). Conclusions: Despite high self-reported awareness, framework-based proficiency in AFO–FC tuning was limited within this sample. Self-reported routine implementation was more frequently reported among respondents with higher framework-based proficiency, whereas no statistically significant associations were observed with educational level, clinical experience, or annual AFO case volume. These hypothesis-generating findings should be interpreted cautiously given the cross-sectional design and framework-based (non-validated) classification.
- 9 April 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (8) , 2846
Open AccessAwareness, Framework-Based Proficiency, and Clinical Implementation of Ankle Foot Orthosis–Footwear Combination (AFO–FC) Tuning: A Cross-Sectional Survey
Background: Ankle foot orthosis–footwear combination (AFO–FC) tuning involves structured adjustment of the AFO relative to footwear to optimise shank alignment and ground reaction force (GRF) positioning during stance. Although established biomechanical frameworks and clinical algorithms are available, variability in clinical implementation persists. Previous investigations have primarily relied on self-reported practice within single healthcare settings and have not, to our knowledge, systematically examined how orthotists articulate and apply tuning principles within structured clinical reasoning across diverse educational and practice environments. Objectives: This study aimed to determine the level of awareness and framework-based proficiency in AFO–FC tuning among practising orthotists in a geographically diverse convenience sample, to examine the extent to which AFO–FC tuning is integrated into routine clinical practice, and to explore associations between framework-based proficiency level and selected professional characteristics. Methods: A cross-sectional study was conducted using an online survey of practising orthotists (n = 245). Awareness of AFO–FC tuning and self-reported routine implementation were assessed. Framework-based proficiency was evaluated among respondents reporting awareness (n = 212) using structured content analysis of open-text responses within a predefined exploratory five-domain biomechanical framework, and classified as limited (0–1 domains), partial (2–3 domains), or full (4–5 domains). Associations between framework-based proficiency level and professional characteristics were examined using chi-square tests. Binary logistic regression was performed to assess the association between framework-based proficiency level and self-reported routine implementation. Results: Self-reported awareness of AFO–FC tuning was high (86.5%), whereas 53.5% reported routine implementation. Based on the framework scoring, 59.0% demonstrated limited framework-based proficiency, 31.6% partial framework-based proficiency, and 9.4% full framework-based proficiency. No statistically significant associations were observed in this sample between framework-based proficiency level and educational qualification, years of clinical experience, or annual AFO case volume (p > 0.05). Full framework-based proficiency was associated with higher odds of self-reported routine implementation (OR = 4.03, 95% CI 1.44–11.25, p = 0.008). Conclusions: Despite high self-reported awareness, framework-based proficiency in AFO–FC tuning was limited within this sample. Self-reported routine implementation was more frequently reported among respondents with higher framework-based proficiency, whereas no statistically significant associations were observed with educational level, clinical experience, or annual AFO case volume. These hypothesis-generating findings should be interpreted cautiously given the cross-sectional design and framework-based (non-validated) classification.
- Open Access
- 6 February 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (3) , 1291
Assessing Lower-Limb Prosthetic Users with the Trinity Amputation and Prosthesis Experience Scale-Revised: A Cross-Sectional Study
Background: Lower limb amputation affects physical function, mental health, and body image. Rehabilitation outcomes depend on both psychological adjustment and functional performance, including mobility and prosthesis satisfaction. This study aimed to evaluate psychological adjustment, activity restriction, and prosthesis satisfaction among lower-limb prosthetic users in Jordan using the Arabic TAPES-R. Objective: To assess, using a validated tool, the psychological adjustment, activity restriction, and prosthesis satisfaction of lower-limb prosthetic users in Jordan, aligning with the study title and cross-sectional design. Methods: This cross-sectional study included 74 unilateral lower-limb prosthetic users (66.2% male, mean age 42.4 ± 13.1 years). Sociodemographic and body composition characteristics were recorded. Participants completed the Arabic TAPES-R between September 2024 and April 2025. The TAPES-R measured psychosocial adjustment, activity restriction, and prosthesis satisfaction. Data were analyzed using descriptive statistics, Cronbach’s alpha for internal consistency, independent-samples t-tests, and Pearson correlations (p < 0.05). Results: Participants demonstrated generally positive psychosocial adjustment (Psychosocial Total = 3.08 ± 0.52) and moderate prosthesis satisfaction (Total Satisfaction = 2.23 ± 0.47), with variable activity restriction (8.76 ± 5.61). Internal consistency was strong across TAPES-R subscales (α = 0.816–0.955). Functional Satisfaction was higher in those with transfemoral than transtibial amputation (p = 0.041). Psychosocial adjustment correlated positively with prosthesis satisfaction (r = 0.48, p < 0.001) and negatively with activity restriction (r = −0.52, p < 0.001). Residual limb pain (45.9%) was associated with higher activity restriction (p = 0.022), and phantom limb pain (55.4%) with lower prosthetic satisfaction (p = 0.031). Conclusions: The Arabic TAPES-R effectively identifies psychological adjustment, activity restriction, and prosthesis satisfaction in lower-limb prosthetic users in Jordan. Participants generally reported positive psychosocial adjustment and moderate prosthesis satisfaction, but functional limitations remain, particularly in those with residual or phantom limb pain. These findings support the use of the TAPES-R as a clinical and research screening tool and provide guidance for targeted rehabilitation interventions.
- 6 February 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (3) , 1291
Open AccessAssessing Lower-Limb Prosthetic Users with the Trinity Amputation and Prosthesis Experience Scale-Revised: A Cross-Sectional Study
Background: Lower limb amputation affects physical function, mental health, and body image. Rehabilitation outcomes depend on both psychological adjustment and functional performance, including mobility and prosthesis satisfaction. This study aimed to evaluate psychological adjustment, activity restriction, and prosthesis satisfaction among lower-limb prosthetic users in Jordan using the Arabic TAPES-R. Objective: To assess, using a validated tool, the psychological adjustment, activity restriction, and prosthesis satisfaction of lower-limb prosthetic users in Jordan, aligning with the study title and cross-sectional design. Methods: This cross-sectional study included 74 unilateral lower-limb prosthetic users (66.2% male, mean age 42.4 ± 13.1 years). Sociodemographic and body composition characteristics were recorded. Participants completed the Arabic TAPES-R between September 2024 and April 2025. The TAPES-R measured psychosocial adjustment, activity restriction, and prosthesis satisfaction. Data were analyzed using descriptive statistics, Cronbach’s alpha for internal consistency, independent-samples t-tests, and Pearson correlations (p < 0.05). Results: Participants demonstrated generally positive psychosocial adjustment (Psychosocial Total = 3.08 ± 0.52) and moderate prosthesis satisfaction (Total Satisfaction = 2.23 ± 0.47), with variable activity restriction (8.76 ± 5.61). Internal consistency was strong across TAPES-R subscales (α = 0.816–0.955). Functional Satisfaction was higher in those with transfemoral than transtibial amputation (p = 0.041). Psychosocial adjustment correlated positively with prosthesis satisfaction (r = 0.48, p < 0.001) and negatively with activity restriction (r = −0.52, p < 0.001). Residual limb pain (45.9%) was associated with higher activity restriction (p = 0.022), and phantom limb pain (55.4%) with lower prosthetic satisfaction (p = 0.031). Conclusions: The Arabic TAPES-R effectively identifies psychological adjustment, activity restriction, and prosthesis satisfaction in lower-limb prosthetic users in Jordan. Participants generally reported positive psychosocial adjustment and moderate prosthesis satisfaction, but functional limitations remain, particularly in those with residual or phantom limb pain. These findings support the use of the TAPES-R as a clinical and research screening tool and provide guidance for targeted rehabilitation interventions.
- Open Access
- 3 October 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (10) , e0333481
Impact of functional and technical quality on patient satisfaction in prosthetic and orthotic care: A cross-sectional study
Patient satisfaction with prosthetic and orthotic services is shaped by both functional quality, such as communication and service accessibility, and technical quality, including device durability and usability. This study examined how these dimensions are associated with patient satisfaction in diverse healthcare settings in Jordan, a low- to middle-income country. A cross-sectional survey of 307 users from government, military, private, and non-governmental (NGO) providers was conducted using a 28-item questionnaire developed from existing literature. Confirmatory factor analysis and structural equation modeling confirmed the scale’s validity and tested associations between variables. Both functional quality (β = 0.521, p < 0.001) and technical quality (β = 0.382, p < 0.001) were significantly associated with satisfaction, with functional quality showing a stronger influence. NGO users reported the highest satisfaction scores, and the model explained 41.7% of the variance in satisfaction. ANOVA results revealed statistically significant differences among provider types. These findings highlight the value of patient-centered care and suggest that enhancing communication, accessibility, and service responsiveness may improve satisfaction, particularly in public and private sectors.
- 3 October 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (10) , e0333481
Open AccessImpact of functional and technical quality on patient satisfaction in prosthetic and orthotic care: A cross-sectional study
Patient satisfaction with prosthetic and orthotic services is shaped by both functional quality, such as communication and service accessibility, and technical quality, including device durability and usability. This study examined how these dimensions are associated with patient satisfaction in diverse healthcare settings in Jordan, a low- to middle-income country. A cross-sectional survey of 307 users from government, military, private, and non-governmental (NGO) providers was conducted using a 28-item questionnaire developed from existing literature. Confirmatory factor analysis and structural equation modeling confirmed the scale’s validity and tested associations between variables. Both functional quality (β = 0.521, p < 0.001) and technical quality (β = 0.382, p < 0.001) were significantly associated with satisfaction, with functional quality showing a stronger influence. NGO users reported the highest satisfaction scores, and the model explained 41.7% of the variance in satisfaction. ANOVA results revealed statistically significant differences among provider types. These findings highlight the value of patient-centered care and suggest that enhancing communication, accessibility, and service responsiveness may improve satisfaction, particularly in public and private sectors.
- Open Access
- 1 October 2025
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 16 (10) , 370
The Current State of 3D-Printed Prostheses Clinical Outcomes: A Systematic Review
Introduction: 3D-printing is an emerging technology in the field of prosthetics, offering advantages such as cost-effectiveness, ease of customization, and improved accessibility. While previous reviews have focused on limited aspects, the aim of this systematic review is to provide a comprehensive evaluation of the clinical outcomes of 3D-printed prostheses for both upper and lower limbs. Methods: A search was conducted following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines across six databases (PubMed, Web of Science, EBSCO, Scopus, Cochrane Library, and Sage). Studies on 3D-printed prostheses in human rehabilitation that focused on the clinical outcomes of the device were included, while studies lacking clinical data, 3D printing details, or focusing on traditional manufacturing methods were excluded. Finally, the risk of bias was assessed using the modified Downs & Black Checklist. Results: A total of 1420 studies were identified, with 11 meeting the inclusion criteria. The included studies assessed different 3D-printed prosthetic types and upper and lower limb prostheses. The main clinical outcomes analyzed were functional performance, design and material integrity, and overall effectiveness of 3D-printed prostheses. Studies on upper limb prostheses reported improved dexterity, range of motion (ROM), and user satisfaction, despite some durability limitations. Lower limb prostheses showed enhancements in comfort, gait parameters, and customization, particularly in amphibious and partial foot designs. Conclusions: 3D-printed prostheses show potential to improve functional performance, patient satisfaction, fit, and implementation feasibility compared to conventional methods. However, limitations such as small sample sizes, variability in assessment tools, and limited high-quality evidence highlight the need for further research to support broader clinical adoption.
- 1 October 2025
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 16 (10) , 370
Open AccessThe Current State of 3D-Printed Prostheses Clinical Outcomes: A Systematic Review
Introduction: 3D-printing is an emerging technology in the field of prosthetics, offering advantages such as cost-effectiveness, ease of customization, and improved accessibility. While previous reviews have focused on limited aspects, the aim of this systematic review is to provide a comprehensive evaluation of the clinical outcomes of 3D-printed prostheses for both upper and lower limbs. Methods: A search was conducted following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines across six databases (PubMed, Web of Science, EBSCO, Scopus, Cochrane Library, and Sage). Studies on 3D-printed prostheses in human rehabilitation that focused on the clinical outcomes of the device were included, while studies lacking clinical data, 3D printing details, or focusing on traditional manufacturing methods were excluded. Finally, the risk of bias was assessed using the modified Downs & Black Checklist. Results: A total of 1420 studies were identified, with 11 meeting the inclusion criteria. The included studies assessed different 3D-printed prosthetic types and upper and lower limb prostheses. The main clinical outcomes analyzed were functional performance, design and material integrity, and overall effectiveness of 3D-printed prostheses. Studies on upper limb prostheses reported improved dexterity, range of motion (ROM), and user satisfaction, despite some durability limitations. Lower limb prostheses showed enhancements in comfort, gait parameters, and customization, particularly in amphibious and partial foot designs. Conclusions: 3D-printed prostheses show potential to improve functional performance, patient satisfaction, fit, and implementation feasibility compared to conventional methods. However, limitations such as small sample sizes, variability in assessment tools, and limited high-quality evidence highlight the need for further research to support broader clinical adoption.
- Open Access
- 1 September 2025
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 26 (1) , 1-26
The current state of 3D-printed orthoses clinical outcomes: a systematic review
3D-printing is an emerging technology that is used in the manufacturing of orthotic devices. 3D-printing has many advantages such as improved fit, comfort, effectiveness, and patient satisfaction. While some challenges like durability and material selection remain, the aim of this systematic review is to provide a comprehensive evaluation of the clinical outcomes of 3D-printed orthoses. A search was conducted following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines across six databases (PubMed, Web of Science, EBSCO, Scopus, Cochrane Library, and Sage). Studies on 3D-printed orthoses in human rehabilitation that focused on the clinical outcomes of the device were included. While studies lacking clinical data, 3D-printing details, or focusing on traditional manufacturing methods were excluded. Finally, the risk of bias was assessed using the modified Downs & Black Checklist. A total of 1279 studies were identified, with 62 meeting the inclusion criteria. The included studies assessed different 3D-printed orthotic types, including insoles, ankle foot orthoses (AFOs), spinal orthoses, upper-limb orthoses, and helmets. The main clinical outcomes that were analyzed are gait parameters, functional performance, radiographic measurements, comfort, fit, and effectiveness. Studies on 3D-printed insoles demonstrated effective plantar pressure redistribution, and increased comfort. While studies on 3D-printed AFOs showed improvements in gait symmetry and mobility. 3D-printed spinal orthotics showed reductions in Cobb angles and enhanced postural stability in scoliotic patients. While 3D-printed upper-limb orthoses found improved grip strength, spasticity management, and user satisfaction. Finally, studies on 3D-printed helmets for cranial deformities demonstrated improved fit and reduced treatment duration. 3D-printed orthoses can enhance gait parameters, functional performance, comfort, fit, and effectiveness, compared to conventional methods. However, limitations such as small sample sizes, lack of standardized assessment methods, and durability concerns must be addressed through further research.
- 1 September 2025
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 26 (1) , 1-26
Open AccessThe current state of 3D-printed orthoses clinical outcomes: a systematic review
3D-printing is an emerging technology that is used in the manufacturing of orthotic devices. 3D-printing has many advantages such as improved fit, comfort, effectiveness, and patient satisfaction. While some challenges like durability and material selection remain, the aim of this systematic review is to provide a comprehensive evaluation of the clinical outcomes of 3D-printed orthoses. A search was conducted following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines across six databases (PubMed, Web of Science, EBSCO, Scopus, Cochrane Library, and Sage). Studies on 3D-printed orthoses in human rehabilitation that focused on the clinical outcomes of the device were included. While studies lacking clinical data, 3D-printing details, or focusing on traditional manufacturing methods were excluded. Finally, the risk of bias was assessed using the modified Downs & Black Checklist. A total of 1279 studies were identified, with 62 meeting the inclusion criteria. The included studies assessed different 3D-printed orthotic types, including insoles, ankle foot orthoses (AFOs), spinal orthoses, upper-limb orthoses, and helmets. The main clinical outcomes that were analyzed are gait parameters, functional performance, radiographic measurements, comfort, fit, and effectiveness. Studies on 3D-printed insoles demonstrated effective plantar pressure redistribution, and increased comfort. While studies on 3D-printed AFOs showed improvements in gait symmetry and mobility. 3D-printed spinal orthotics showed reductions in Cobb angles and enhanced postural stability in scoliotic patients. While 3D-printed upper-limb orthoses found improved grip strength, spasticity management, and user satisfaction. Finally, studies on 3D-printed helmets for cranial deformities demonstrated improved fit and reduced treatment duration. 3D-printed orthoses can enhance gait parameters, functional performance, comfort, fit, and effectiveness, compared to conventional methods. However, limitations such as small sample sizes, lack of standardized assessment methods, and durability concerns must be addressed through further research.