Ugur Akgun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ugur Akgun has a total of 339 co-authors. Here are the top co-authors by number of shared publications:
F. Duru
Physics Department, Coe College, Cedar Rapids, IA, U.S.A.
3 shared publicationsY. Onel
Department of Physics and Astronomy, University of Iowa, Iowa City, IA, U.S.A.
3 shared publicationsJ. Schletzbaum
Physics Department, Coe College, Cedar Rapids, IA, U.S.A.
2 shared publicationsM. Martinez-Szewczyk
Physics Department, Coe College, Cedar Rapids, IA 52402, U.S.A.
2 shared publicationsY Onel
Department of Physics and Astronomy, University of Iowa, Iowa City, IA, United States of America
2 shared publications- Yasar Onel
The University of Iowa
2 shared publications
Latest Publications
- Open Access
High-Density Glass Scintillators for Proton Radiography—Relative Luminosity, Proton Response, and Spatial Resolution
Proton radiography is a promising development in proton therapy, and researchers are currently exploring optimal detector materials to construct proton radiography detector arrays. High-density glass scintillators may improve integrating-mode proton radiography detectors by increasing spatial resolution and decreasing detector thickness. We evaluated several new scintillators, activated with europium or terbium, with proton response measurements and Monte Carlo simulations, characterizing relative luminosity, ionization quenching, and proton radiograph spatial resolution. We applied a correction based on Birks’s analytical model for ionization quenching. The data demonstrate increased relative luminosity with increased activation element concentration, and higher relative luminosity for samples activated with europium. An increased glass density enables more compact detector geometries and higher spatial resolution. These findings suggest that a tungsten and gadolinium oxide-based glass activated with 4% europium is an ideal scintillator for testing in a full-size proton radiography detector.
Open AccessHigh-Density Glass Scintillators for Proton Radiography—Relative Luminosity, Proton Response, and Spatial Resolution
Proton radiography is a promising development in proton therapy, and researchers are currently exploring optimal detector materials to construct proton radiography detector arrays. High-density glass scintillators may improve integrating-mode proton radiography detectors by increasing spatial resolution and decreasing detector thickness. We evaluated several new scintillators, activated with europium or terbium, with proton response measurements and Monte Carlo simulations, characterizing relative luminosity, ionization quenching, and proton radiograph spatial resolution. We applied a correction based on Birks’s analytical model for ionization quenching. The data demonstrate increased relative luminosity with increased activation element concentration, and higher relative luminosity for samples activated with europium. An increased glass density enables more compact detector geometries and higher spatial resolution. These findings suggest that a tungsten and gadolinium oxide-based glass activated with 4% europium is an ideal scintillator for testing in a full-size proton radiography detector.
- Open Access
Proton stopping power images from Monte Carlo simulated dual-energy CT scans
We test the feasibility of calculating proton stopping power (SP) from a set of virtual monochromatic (VM) CT images, created with Monte Carlo-generated CT scans, using a dual-energy CT-to-SP procedure. The Monte Carlo CT simulations, with 70 and 150 kVp spectra, were modeled on the x-ray tube parameters of the SOMATOM Force dual-source DECT scanner and the Gammex RMI 467 tissue calibration phantom. Reconstructed SP images were created with two VM x-ray images, and the monochromatic energy pairs were chosen to minimize the SP residual errors using the root-mean-squared-error (RMSE). The contrast of phantom inserts has also been examined, in addition to relative errors of the average reconstructed insert values (which are calculated using the known electron densities and chemical compositions of each material, provided by the manufacturer). Results were also compared to a similar dual-energy-based SP conversion procedure for comparison. Modest reductions in errors and noise were seen in almost all inserts in both low- and high-density configurations of the phantom, with a visible reduction in beam-hardening streaking artifacts. Our Monte Carlo simulated DECT scans confirm the feasibility of previously proposed methods of DECT-based $ S(\rho_e, Z) $-determination. By utilizing VM images and only optimizing the RMSE over specific inserts, the residual error across the most vital bodily tissues may be reduced when extremely low- or high-density tissues are known to be present.
Open AccessProton stopping power images from Monte Carlo simulated dual-energy CT scans
We test the feasibility of calculating proton stopping power (SP) from a set of virtual monochromatic (VM) CT images, created with Monte Carlo-generated CT scans, using a dual-energy CT-to-SP procedure. The Monte Carlo CT simulations, with 70 and 150 kVp spectra, were modeled on the x-ray tube parameters of the SOMATOM Force dual-source DECT scanner and the Gammex RMI 467 tissue calibration phantom. Reconstructed SP images were created with two VM x-ray images, and the monochromatic energy pairs were chosen to minimize the SP residual errors using the root-mean-squared-error (RMSE). The contrast of phantom inserts has also been examined, in addition to relative errors of the average reconstructed insert values (which are calculated using the known electron densities and chemical compositions of each material, provided by the manufacturer). Results were also compared to a similar dual-energy-based SP conversion procedure for comparison. Modest reductions in errors and noise were seen in almost all inserts in both low- and high-density configurations of the phantom, with a visible reduction in beam-hardening streaking artifacts. Our Monte Carlo simulated DECT scans confirm the feasibility of previously proposed methods of DECT-based $ S(\rho_e, Z) $-determination. By utilizing VM images and only optimizing the RMSE over specific inserts, the residual error across the most vital bodily tissues may be reduced when extremely low- or high-density tissues are known to be present.
- 23 November 2021
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 8 (1) , 015009
Development of a dosimeter prototype with machine learning based 3-D dose reconstruction capabilities
A 3-D dosimeter fills the need for treatment plan and delivery verification required by every modern radiation-therapy method used today. This report summarizes a proof-of-concept study to develop a water-equivalent solid 3-D dosimeter that is based on novel radiation-hard scintillating material. The active material of the prototype dosimeter is a blend of radiation-hard peroxide-cured polysiloxane plastic doped with scintillating agent P-Terphenyl and wavelength-shifter BisMSB. The prototype detector was tested with 6 MV and 10 MV x-ray beams at Ohio State University’s Comprehensive Cancer Center. A 3-D dose distribution was successfully reconstructed by a neural network specifically trained for this prototype. This report summarizes the material production procedure, the material’s water equivalency investigation, the design of the prototype dosimeter and its beam tests, as well as the details of the utilized machine learning approach and the reconstructed 3-D dose distributions.
- 23 November 2021
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 8 (1) , 015009
Development of a dosimeter prototype with machine learning based 3-D dose reconstruction capabilities
A 3-D dosimeter fills the need for treatment plan and delivery verification required by every modern radiation-therapy method used today. This report summarizes a proof-of-concept study to develop a water-equivalent solid 3-D dosimeter that is based on novel radiation-hard scintillating material. The active material of the prototype dosimeter is a blend of radiation-hard peroxide-cured polysiloxane plastic doped with scintillating agent P-Terphenyl and wavelength-shifter BisMSB. The prototype detector was tested with 6 MV and 10 MV x-ray beams at Ohio State University’s Comprehensive Cancer Center. A 3-D dose distribution was successfully reconstructed by a neural network specifically trained for this prototype. This report summarizes the material production procedure, the material’s water equivalency investigation, the design of the prototype dosimeter and its beam tests, as well as the details of the utilized machine learning approach and the reconstructed 3-D dose distributions.
- 1 June 2020
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 15 (6) , T06002
Discriminating the muon noise at the PMT windows in calorimeters
In particle physics experiments, stray muons are known to be a source of anomalous signals when they produce Cherenkov photons in the PMT window. Most recent of such events were reported by CMS Hadronic Forward calorimeters, where PMTs read out the Cherenkov signal generated within the quartz fibers. This study focuses on finding an efficient way to discriminate the Cherenkov signal coming from the quartz fibers from the ones generated at the face of the PMT due to stray muons. We report that these two different signals can be discriminated based on their pulse widths. The study also shows the performance of a proof-of-concept circuit prototype that effectively tags the two types of pulses.
- 1 June 2020
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 15 (6) , T06002
Discriminating the muon noise at the PMT windows in calorimeters
In particle physics experiments, stray muons are known to be a source of anomalous signals when they produce Cherenkov photons in the PMT window. Most recent of such events were reported by CMS Hadronic Forward calorimeters, where PMTs read out the Cherenkov signal generated within the quartz fibers. This study focuses on finding an efficient way to discriminate the Cherenkov signal coming from the quartz fibers from the ones generated at the face of the PMT due to stray muons. We report that these two different signals can be discriminated based on their pulse widths. The study also shows the performance of a proof-of-concept circuit prototype that effectively tags the two types of pulses.
- 1 June 2019
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 14 (06) , P06013
A glass neutron detector with machine learning capabilities
The detection of neutrons above background levels is an indication of nuclear materials, creating significant applications for handheld neutron detectors in homeland security. For such applications, a 10B and 6Li enriched, scintillating glass neutron detector was designed. The model is compact enough to be used as a handheld detector and is equipped with machine learning capabilities to determine the location of the source and discriminate a neutron from a gamma. Lithium Borosilicate glass samples, with up to 70% 10B and 6Li content, and doped with Tb and Eu, were engineered to optimize the performance of the detector. The scintillation properties and neutron/gamma detection capabilities of the glass samples were tested. The model detector's performance was simulated in Geant4 and the simulation data was utilized for machine learning to predict the location of the source with an Artificial Neural Network (ANN). The reported handheld neutron detector design with the implemented artificial intelligence capability can achieve 99.9% accuracy in neutron/gamma discrimination, 8.9% error in radial angle estimates, and 2.9% error in azimuthal angle estimates.
- 1 June 2019
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 14 (06) , P06013
A glass neutron detector with machine learning capabilities
The detection of neutrons above background levels is an indication of nuclear materials, creating significant applications for handheld neutron detectors in homeland security. For such applications, a 10B and 6Li enriched, scintillating glass neutron detector was designed. The model is compact enough to be used as a handheld detector and is equipped with machine learning capabilities to determine the location of the source and discriminate a neutron from a gamma. Lithium Borosilicate glass samples, with up to 70% 10B and 6Li content, and doped with Tb and Eu, were engineered to optimize the performance of the detector. The scintillation properties and neutron/gamma detection capabilities of the glass samples were tested. The model detector's performance was simulated in Geant4 and the simulation data was utilized for machine learning to predict the location of the source with an Artificial Neural Network (ANN). The reported handheld neutron detector design with the implemented artificial intelligence capability can achieve 99.9% accuracy in neutron/gamma discrimination, 8.9% error in radial angle estimates, and 2.9% error in azimuthal angle estimates.
- 9 March 2017
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10132, 101323V
High density scintillating glass proton imaging detector
In recent years, proton therapy has achieved remarkable precision in delivering doses to cancerous cells while avoiding healthy tissue. However, in order to utilize this high precision treatment, greater accuracy in patient positioning is needed. An accepted approximate uncertainty of ±3% exists in the current practice of proton therapy due to conversions between x-ray and proton stopping power. The use of protons in imaging would eliminate this source of error and lessen the radiation exposure of the patient. To this end, this study focuses on developing a novel proton-imaging detector built with high-density glass scintillator. The model described herein contains a compact homogeneous proton calorimeter composed of scintillating, high density glass as the active medium. The unique geometry of this detector allows for the measurement of both the position and residual energy of protons, eliminating the need for a separate set of position trackers in the system. Average position and energy of a pencil beam of 106 protons is used to reconstruct the image rather than by analyzing individual proton data. Simplicity and efficiency were major objectives in this model in order to present an imaging technique that is compact, cost-effective, and precise, as well as practical for a clinical setting with pencil-beam scanning proton therapy equipment. In this work, the development of novel high-density glass scintillator and the unique conceptual design of the imager are discussed; a proof-of-principle Monte Carlo simulation study is performed; preliminary two-dimensional images reconstructed from the Geant4 simulation are presented.
- 9 March 2017
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10132, 101323V
High density scintillating glass proton imaging detector
In recent years, proton therapy has achieved remarkable precision in delivering doses to cancerous cells while avoiding healthy tissue. However, in order to utilize this high precision treatment, greater accuracy in patient positioning is needed. An accepted approximate uncertainty of ±3% exists in the current practice of proton therapy due to conversions between x-ray and proton stopping power. The use of protons in imaging would eliminate this source of error and lessen the radiation exposure of the patient. To this end, this study focuses on developing a novel proton-imaging detector built with high-density glass scintillator. The model described herein contains a compact homogeneous proton calorimeter composed of scintillating, high density glass as the active medium. The unique geometry of this detector allows for the measurement of both the position and residual energy of protons, eliminating the need for a separate set of position trackers in the system. Average position and energy of a pencil beam of 106 protons is used to reconstruct the image rather than by analyzing individual proton data. Simplicity and efficiency were major objectives in this model in order to present an imaging technique that is compact, cost-effective, and precise, as well as practical for a clinical setting with pencil-beam scanning proton therapy equipment. In this work, the development of novel high-density glass scintillator and the unique conceptual design of the imager are discussed; a proof-of-principle Monte Carlo simulation study is performed; preliminary two-dimensional images reconstructed from the Geant4 simulation are presented.
- 1 March 2017
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 12 (3) , P03017
Radiation Hard Plastic Scintillators for a New Generation of Particle Detectors
The radiation hardness of specific scintillating materials used in particle physics experiments is one of the main focuses of research in detector development. This report summarizes the preparation methods, light yield characterization and radiation damage tests of a plastic scintillator with a polysiloxane base and pTP and bis-MSB dopants. The scintillator is shown to be a promising candidate for particle detectors with its intense light output around 400 nm and very little scintillation or transmission loss after proton irradiation of 4 × 105 Gy.
- 1 March 2017
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 12 (3) , P03017
Radiation Hard Plastic Scintillators for a New Generation of Particle Detectors
The radiation hardness of specific scintillating materials used in particle physics experiments is one of the main focuses of research in detector development. This report summarizes the preparation methods, light yield characterization and radiation damage tests of a plastic scintillator with a polysiloxane base and pTP and bis-MSB dopants. The scintillator is shown to be a promising candidate for particle detectors with its intense light output around 400 nm and very little scintillation or transmission loss after proton irradiation of 4 × 105 Gy.
- 1 October 2016
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 11 (10) , T10006
Post Situ neutron and gamma radiation damage tests on different quartz types
Post-Situ neutron and gamma radiation damage studies performed on seven types of quartz fibers are reported. All fibers contained quartz cores, some of which were UV enhanced. The fiber cladding was either polymer or quartz, while the buffer was either polymide or acrylite. Previous studies with electron and proton irradiation on numerous types of quartz fibers have shown different optical degradation levels. However, neutron and gamma irradiation has not been investigated for similar quartz fibers before. After 17.6 × 104 Gray of neutron and 73.5 × 104 Gray of gamma radiation, wavelength specific damage to each type of fibers was determined. It is seen that the FBP type quartz fiber by Polymicro shows the least damage due to neutron and gamma radiations.
- 1 October 2016
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 11 (10) , T10006
Post Situ neutron and gamma radiation damage tests on different quartz types
Post-Situ neutron and gamma radiation damage studies performed on seven types of quartz fibers are reported. All fibers contained quartz cores, some of which were UV enhanced. The fiber cladding was either polymer or quartz, while the buffer was either polymide or acrylite. Previous studies with electron and proton irradiation on numerous types of quartz fibers have shown different optical degradation levels. However, neutron and gamma irradiation has not been investigated for similar quartz fibers before. After 17.6 × 104 Gray of neutron and 73.5 × 104 Gray of gamma radiation, wavelength specific damage to each type of fibers was determined. It is seen that the FBP type quartz fiber by Polymicro shows the least damage due to neutron and gamma radiations.
- Open Access
- 2 February 2015
- Published by Wiley in Pharmacology Research & Perspectives
- Vol. 3 (2) , e00114
Characterizing the binding interactions between P‐glycoprotein and eight known cardiovascular transport substrates
The multidrug efflux pump P‐glycoprotein (Pgp) is upregulated in cardiomyocytes following chronic ischemia from infarction and hypoxia caused by sleep apnea. This report summarizes the molecular dynamic studies performed on eight cardiovascular drugs to determine their corresponding binding sites on mouse Pgp. Selected Pgp transport ligands include: Amiodarone, Bepridil, Diltiazem, Dipyridamole, Nicardipine, Nifedipine, Propranolol, and Quinidine. Extensive molecular dynamic equilibration simulations were performed to determine drug docking interactions. Distinct binding sites were not observed, but rather a binding belt was seen with multiple residues playing a role in each studied drug's stable docking. Three key drug–protein interactions were identified: hydrogen bonding, hydrophobic packing, and the formation of a “cage” of aromatic residues around the drug. After drug stabilization, water molecules were observed to leak into the binding belt and condense around the drug. Water influx into the binding domain of Pgp may play a role in catalytic transition and drug expulsion. The cytoplasmic recruitment theory was also tested, and the drugs were observed to interact with conserved loops of residues with a strong affinity. A free energy change of astronomical value is required to recruit the drug from the cytoplasm to the binding belt within the transmembrane domain of Pgp.
- 2 February 2015
- Published by Wiley in Pharmacology Research & Perspectives
- Vol. 3 (2) , e00114
Open AccessCharacterizing the binding interactions between P‐glycoprotein and eight known cardiovascular transport substrates
The multidrug efflux pump P‐glycoprotein (Pgp) is upregulated in cardiomyocytes following chronic ischemia from infarction and hypoxia caused by sleep apnea. This report summarizes the molecular dynamic studies performed on eight cardiovascular drugs to determine their corresponding binding sites on mouse Pgp. Selected Pgp transport ligands include: Amiodarone, Bepridil, Diltiazem, Dipyridamole, Nicardipine, Nifedipine, Propranolol, and Quinidine. Extensive molecular dynamic equilibration simulations were performed to determine drug docking interactions. Distinct binding sites were not observed, but rather a binding belt was seen with multiple residues playing a role in each studied drug's stable docking. Three key drug–protein interactions were identified: hydrogen bonding, hydrophobic packing, and the formation of a “cage” of aromatic residues around the drug. After drug stabilization, water molecules were observed to leak into the binding belt and condense around the drug. Water influx into the binding domain of Pgp may play a role in catalytic transition and drug expulsion. The cytoplasmic recruitment theory was also tested, and the drugs were observed to interact with conserved loops of residues with a strong affinity. A free energy change of astronomical value is required to recruit the drug from the cytoplasm to the binding belt within the transmembrane domain of Pgp.
- 1 June 2014
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 9 (06) , T06005
Characterization of 1800 Hamamatsu R7600-M4 PMTs for CMS HF Calorimeter upgrade
- 1 June 2014
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 9 (06) , T06005
Characterization of 1800 Hamamatsu R7600-M4 PMTs for CMS HF Calorimeter upgrade