Yi Na
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yi Na has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Baolong Wang
Sanya Institute of Breeding and Multiplication, Hainan University, Sanya 572025, China
3 shared publications - Jian Liu
School of Horticulture, Hainan University, Haikou 570228, China
3 shared publications - Xiwen Luo
Key Laboratory of Key Technology on Agricultural Machine and Equipment, South China Agricultural University, Ministry of Education, Guangzhou 510642, China
1 shared publication - Xuyong Wu
Key Laboratory for Quality Regulation of Tropical Horticultural Crops of Hainan Province, School of Horticulture, Hainan University, Haikou 570208, China
1 shared publication - Yihong Pan
School of Horticulture, Hainan University, Haikou 570228, China
1 shared publication - Yini Chen
School of Tropical Agriculture and Forestry, Hainan University, Haikou 570228, China
1 shared publication
Latest Publications
- Open Access
CFD Simulation and Experiments of Pneumatic Centralized Cylinder Metering Device Cavity and Airflow Distributor
The distribution of airflow field in the pneumatic centralized cylinder metering device cavity, airstream distributor and different angle seed feeding tubes was investigated based on the pneumatic centralized cylinder direct-seeding metering device to study the effect on the movement law of rice seed. In total, three suction hole sizes (1.5 mm, 2 mm and 2.0 mm 45° wedge) were used for CFD simulation. The results showed that under the same inlet vacuum, the pressure at the 1.5 mm hole is higher than the other two types of holes, and the five measurement points of the 2 mm hole are more stable than the other two types of holes. At the positive pressure seed feeding area, the inlet pressure was set as 1.5 kPa, and the outlet pressure was set as 0 Pa. The pressure distribution at different measuring points showed that the 2 mm 45° wedge had the most uneven positive pressure distribution, and the 1.5 mm hole had higher positive pressure distribution than the 2 mm hole in general. Three different structured airflow distributors were designed. CFD simulation experiments showed that the arc transition type presented better uniformity than the other two types. The uniformity experiments at the ends of the seed-feeding tubes indicated that the airflow velocity had the trend of large in the middle and small at two sides. Finally, the movement law of the rice seeds in seed feeding tubes at different angles was obtained by using high-speed photography. The results showed that the rice seeds in tube C (maximum angle) presented a movement posture of falling sector a and kept falling after colliding in sector b; the rice seeds in tube B (the second angle) presented a movement posture of falling in sector a and kept falling after colliding in sector b. The above research provides a reference for the optimal design of a pneumatic centralized cylinder metering device.
Open AccessCFD Simulation and Experiments of Pneumatic Centralized Cylinder Metering Device Cavity and Airflow Distributor
The distribution of airflow field in the pneumatic centralized cylinder metering device cavity, airstream distributor and different angle seed feeding tubes was investigated based on the pneumatic centralized cylinder direct-seeding metering device to study the effect on the movement law of rice seed. In total, three suction hole sizes (1.5 mm, 2 mm and 2.0 mm 45° wedge) were used for CFD simulation. The results showed that under the same inlet vacuum, the pressure at the 1.5 mm hole is higher than the other two types of holes, and the five measurement points of the 2 mm hole are more stable than the other two types of holes. At the positive pressure seed feeding area, the inlet pressure was set as 1.5 kPa, and the outlet pressure was set as 0 Pa. The pressure distribution at different measuring points showed that the 2 mm 45° wedge had the most uneven positive pressure distribution, and the 1.5 mm hole had higher positive pressure distribution than the 2 mm hole in general. Three different structured airflow distributors were designed. CFD simulation experiments showed that the arc transition type presented better uniformity than the other two types. The uniformity experiments at the ends of the seed-feeding tubes indicated that the airflow velocity had the trend of large in the middle and small at two sides. Finally, the movement law of the rice seeds in seed feeding tubes at different angles was obtained by using high-speed photography. The results showed that the rice seeds in tube C (maximum angle) presented a movement posture of falling sector a and kept falling after colliding in sector b; the rice seeds in tube B (the second angle) presented a movement posture of falling in sector a and kept falling after colliding in sector b. The above research provides a reference for the optimal design of a pneumatic centralized cylinder metering device.
- Open Access
- 18 February 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (4) , 2159
Design and Evaluation of Vacuum Central Drum Seed Metering Device
For the purpose of reducing the number of conventional seed-metering devices and high demand for vacuums, this study designed a vacuum central drum seed-metering device, that is intended to replace multiple seed-metering devices with one, which is comprised of the inner and outer drum. This can be replaced with different diameters of suction holes, ventilation housing, seeding tube, agitating devices, seed box, and seed-cleaning devices, etc. A hybrid rice seed Jingliangyou 1212 was applied as an experimental material, and a JPS-12 computer vision metering device test bench was used to test singular-factor and multi-factor seeding performance of the seed-metering device. The singular-factor performance test of the metering device was conducted under negative pressure of seed suction in the range of 1∼1.5 kPa, at the metering device rotation speed of 10∼60 rpm, with diameters of inlet holes being 2 mm (chamfer: 45°), 2, and 1.5 mm, respectively. The number of seeds was counted by a sucking hole under different factor combinations. The multi-factor test was carried out by rotation rate, negative pressure, and types of sucking holes. A rate of 2 ± 1 rice seed per sucking hole is regarded as the qualified standard. It shows that the qualification rate (2 ± 1 rice seed per sucking hole) of seed suction can reach 97.4% under a combination of metering device rotation speed of 30 r/min, negative pressure of 1.0 kPa, and suction hole diameters of 1.5 mm. High-speed photography was used to study the trajectory of seed-metering at different rotation rates, a locomotive axis was applied to fit the motion curve, and 3D-printing was used to make the seed-metering tube so that the seed collisions could be reduced. This study provides evidence for further optimizing the performance of the vacuum central drum direct-seeding machine for hybrid rice.
- 18 February 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (4) , 2159
Open AccessDesign and Evaluation of Vacuum Central Drum Seed Metering Device
For the purpose of reducing the number of conventional seed-metering devices and high demand for vacuums, this study designed a vacuum central drum seed-metering device, that is intended to replace multiple seed-metering devices with one, which is comprised of the inner and outer drum. This can be replaced with different diameters of suction holes, ventilation housing, seeding tube, agitating devices, seed box, and seed-cleaning devices, etc. A hybrid rice seed Jingliangyou 1212 was applied as an experimental material, and a JPS-12 computer vision metering device test bench was used to test singular-factor and multi-factor seeding performance of the seed-metering device. The singular-factor performance test of the metering device was conducted under negative pressure of seed suction in the range of 1∼1.5 kPa, at the metering device rotation speed of 10∼60 rpm, with diameters of inlet holes being 2 mm (chamfer: 45°), 2, and 1.5 mm, respectively. The number of seeds was counted by a sucking hole under different factor combinations. The multi-factor test was carried out by rotation rate, negative pressure, and types of sucking holes. A rate of 2 ± 1 rice seed per sucking hole is regarded as the qualified standard. It shows that the qualification rate (2 ± 1 rice seed per sucking hole) of seed suction can reach 97.4% under a combination of metering device rotation speed of 30 r/min, negative pressure of 1.0 kPa, and suction hole diameters of 1.5 mm. High-speed photography was used to study the trajectory of seed-metering at different rotation rates, a locomotive axis was applied to fit the motion curve, and 3D-printing was used to make the seed-metering tube so that the seed collisions could be reduced. This study provides evidence for further optimizing the performance of the vacuum central drum direct-seeding machine for hybrid rice.
- Open Access
- 15 November 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (22) , 10785
Simulation and Experimental Study of Light and Thermal Environment of Photovoltaic Greenhouse in Tropical Area Based on Design Builder
In order to study the adaptability of photovoltaic greenhouses to climate in tropical areas, a photovoltaic greenhouse model (photovoltaic panel coverage rate: 76.9%) was built in this study according to a 1:1 proportion. The distribution law of the indoor illuminance, temperature, and humidity were studied simultaneously in the photovoltaic greenhouse by actual measurements and simulation. The filed data are shown as follows: (1) Illuminance: in limited rain winter, the average illuminance and light transmittance were 7.02 kLux and 25.77%, respectively (10:00–16:00); but in different weather conditions during summer, the average illuminance and light transmittance were 15.47 kLux and 32.35%, respectively (9:00–16:00). (2) Temperature and humidity: the indoor temperatures of the greenhouse were between 22.1 and 29.3 °C in limited rain winter, with a relative small temperature difference between indoor and outdoor environments; the relative humidity values were between 69% and 97%; but in summer, the temperatures at all indoor test site were higher than outdoor sites, with an average temperature difference of 2.7 °C and relative humidity values between 46% and 94%. According to the simulation by Design Builder, the average light transmittances were 33.09% in winter and 37.54% in summer, the temperature difference between winter and summer was less than 1 °C, and the relative humidity decreased with the increase of temperature, which basically coincided with the filed data. The results of the analysis showed that the illuminance, temperature and humidity of the photovoltaic greenhouse can satisfy the production requirements of shade-enduring and neutral crops. At the same time, by comparing the illumination, temperature and humidity of the photovoltaic greenhouse with that of an ordinary greenhouse, the former had good adaptability to climate in tropical areas, which can achieve the goal of photovoltaic generation and agricultural production synchronously.
- 15 November 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (22) , 10785
Open AccessSimulation and Experimental Study of Light and Thermal Environment of Photovoltaic Greenhouse in Tropical Area Based on Design Builder
In order to study the adaptability of photovoltaic greenhouses to climate in tropical areas, a photovoltaic greenhouse model (photovoltaic panel coverage rate: 76.9%) was built in this study according to a 1:1 proportion. The distribution law of the indoor illuminance, temperature, and humidity were studied simultaneously in the photovoltaic greenhouse by actual measurements and simulation. The filed data are shown as follows: (1) Illuminance: in limited rain winter, the average illuminance and light transmittance were 7.02 kLux and 25.77%, respectively (10:00–16:00); but in different weather conditions during summer, the average illuminance and light transmittance were 15.47 kLux and 32.35%, respectively (9:00–16:00). (2) Temperature and humidity: the indoor temperatures of the greenhouse were between 22.1 and 29.3 °C in limited rain winter, with a relative small temperature difference between indoor and outdoor environments; the relative humidity values were between 69% and 97%; but in summer, the temperatures at all indoor test site were higher than outdoor sites, with an average temperature difference of 2.7 °C and relative humidity values between 46% and 94%. According to the simulation by Design Builder, the average light transmittances were 33.09% in winter and 37.54% in summer, the temperature difference between winter and summer was less than 1 °C, and the relative humidity decreased with the increase of temperature, which basically coincided with the filed data. The results of the analysis showed that the illuminance, temperature and humidity of the photovoltaic greenhouse can satisfy the production requirements of shade-enduring and neutral crops. At the same time, by comparing the illumination, temperature and humidity of the photovoltaic greenhouse with that of an ordinary greenhouse, the former had good adaptability to climate in tropical areas, which can achieve the goal of photovoltaic generation and agricultural production synchronously.