MRMohamed Rabia

Mohamed Rabia

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mohamed Rabia has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    High-Performance pH Sensor Electrodes Based on a Hexagonal Pt Nanoparticle Array-Coated Nanoporous Alumina Membrane

    by Abeer S. Altowyan, Mohamed Shaban, Asmaa Gamel, Ahmed Gamal, Mona Ali, Mohamed Rabia

    Porous anodic alumina membranes coated with Pt nanoparticles (PAAM/Pt) have been employed as pH sensor electrodes for H+ ion detection. The PAAM was designed using a two-step anodization process. Pt nanoparticles were then sputtered onto the membrane at different deposition times. The membrane’s morphological, chemical, and optical characteristics were carefully assessed following the fabrication stage using a variety of analytical techniques. The potential of the PAAM/Pt sensor electrode was investigated by measuring the potential using a simple potentiometric method. The effects of depositing Pt nanoparticles for 3–7 min on sensor electrode sensitivity were examined. The optimal potentiometric Nernstian response slope for the PAAM/Pt sensor electrode with 5 min Pt sputter coating is 56.31 mV/decade in the pH range of 3.0 to 10 at 293 K. Additionally, the PAAM/Pt sensor electrode’s stability and selectivity in various ions solutions were examined. The sensor electrode had a lifetime of more than six weeks and was kept in a normal air environment.


  • Open Access

    Facile Fabrication of Polyaniline/Pbs Nanocomposite for High-Performance Supercapacitor Application

    by Ahmed Gamal, Mohamed Shaban, Mohammad BinSabt, Mahmoud Moussa, Ashour M. Ahmed, Mohamed Rabia, Hany Hamdy

    In this work, a polyaniline/lead sulfide (PANI/PbS) nanocomposite was prepared by combining the in situ oxidation polymerization method and the surface adsorption process. This nanocomposite was applied as a supercapacitor electrode. The crystal structure, nanomorphology, and optical analysis of PANI and PANI/PbS were investigated. The electrochemical performance of the designed PANI/PbS electrode-based supercapacitor was tested by using cyclic voltammetry (CV), chronopotentiometry (CP), and AC impedance techniques in HCl and Na2SO4 electrolytes. The average crystallite size of the PANI/PbS nanocomposite is about 43 nm. PANI/PbS possesses an agglomerated network related to PANI with additional spherical shapes from PbS nanoparticles. After the PANI/PbS nanocomposite formation, there are enhancements in their absorption intensities. At a current density of 0.4 A g−1, the specific capacitance of PANI/PbS in Na2SO4 and HCl was found to be 303 and 625 F g−1, respectively. In HCl (625 F g−1 and 1500 mF cm−2), the gravimetric and areal capacitances of the PANI/PbS electrode are nearly double those of the Na2SO4 electrolyte. Also, the average specific energy and specific power density values for the PANI/PbS electrode in HCl are 4.168 Wh kg−1 and 196.03 W kg−1, respectively. After 5000 cycles, the capacitance loses only 4.5% of its initial value. The results refer to the high stability and good performance of the designed PANI/PbS as a supercapacitor electrode.


  • Open Access

    Fabrication of ZnO/CNTs for Application in CO2 Sensor at Room Temperature

    by Rana Saad, Ahmed Gamal, Mohamed Zayed, Ashour M. Ahmed, Mohamed Shaban, Mohammad BinSabt, Mohamed Rabia, Hany Hamdy

    Thin films of ZnO and ZnO/carbon nanotubes (CNTs) are prepared and used as CO2 gas sensors. The spray pyrolysis method was used to prepare both ZnO and ZnO/CNTs films, with CNTs first prepared using the chemical vapor deposition method (CVD). The chemical structure and optical analyses for all the prepared nanomaterials were performed using X-ray diffraction (XRD), Fourier transformer infrared spectroscopy (FTIR), and UV/Vis spectrophotometer devices, respectively. According to the XRD analysis, the crystal sizes of ZnO and ZnO/CNTs were approximately 50.4 and 65.2 nm, respectively. CNTs have average inner and outer diameters of about 3 and 13 nm respectively, according to the transmitted electron microscope (TEM), and a wall thickness of about 5 nm. The detection of CO2 is accomplished by passing varying rates of the gas from 30 to 150 sccm over the prepared thin-film electrodes. At 150 sccm, the sensitivities of ZnO and ZnO/CNTs sensors are 6.8% and 22.4%, respectively. The ZnO/CNTs sensor has a very stable sensitivity to CO2 gas for 21 days. Moreover, this sensor has a high selectivity to CO2 in comparison with other gases, in which the ZnO/CNTs sensor has a higher sensitivity to CO2 compared to H2 and C2H2.