Chanchan Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Chanchan Xu has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Xiaojie Wang
Institute of Intelligent Machines, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China
4 shared publications - Shuai Dong
Institute of Humanoid Robots, School of Engineering Science, University of Science and Technology of China, Hefei 230026, China
2 shared publications - Bin Li
Institute of Intelligent Machines, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230000, China
1 shared publication - Fengguan Li
Shien-Ming Wu School of Intelligent Engineering, South China University of Technology, Guangzhou 510641, China
1 shared publication - Jia-Hong Chen
Shien-Ming Wu School of Intelligent Engineering, South China University of Technology, Guangzhou 510641, China
1 shared publication - Jiefeng Xie
Shien-Ming Wu School of Intelligent Engineering, South China University of Technology, Guangzhou 510641, China
1 shared publication
Latest Publications
- Open Access
A Lightweight, Simple-Structure, Low-Cost and Compliant Twisted String Actuator Featuring Continuously Variable Transmission
Twisted string actuators, which are an emerging artificial muscle, efficiently convert rotary motor motion into linear load movement, with advantages like high transmission ratio, compliance, simple structure, and long-distance power transmission. However, the limited range of transmission ratio adjustment remains a challenge. Thus, this paper introduces a novel twisted string actuator design that automatically and continuously adjusts its transmission ratio in response to external loads. Utilizing lightweight hyperelastic slender rods, the twisted string actuator with continuously variable transmission achieves a simple, compact, and cost-effective design. By manipulating the distance between two twisted strings through rod deformation, the transmission ratio continuously adapts to varying load conditions. Mathematical models of the twisted string actuator with continuously variable transmission are derived and experimentally validated, demonstrating a 2.1-fold transmission ratio variation from 0.1 kg to 1.5 kg loads. Application in an anthropomorphic robot finger showcases a 6.2-fold transmission ratio change between unloaded and loaded states. Our twisted string actuator with continuously variable transmission offers unparalleled advantages in weight, cost, simplicity, compliance, and continuous transmission ratio adjustability, making it highly suitable for robotic systems.
Open AccessA Lightweight, Simple-Structure, Low-Cost and Compliant Twisted String Actuator Featuring Continuously Variable Transmission
Twisted string actuators, which are an emerging artificial muscle, efficiently convert rotary motor motion into linear load movement, with advantages like high transmission ratio, compliance, simple structure, and long-distance power transmission. However, the limited range of transmission ratio adjustment remains a challenge. Thus, this paper introduces a novel twisted string actuator design that automatically and continuously adjusts its transmission ratio in response to external loads. Utilizing lightweight hyperelastic slender rods, the twisted string actuator with continuously variable transmission achieves a simple, compact, and cost-effective design. By manipulating the distance between two twisted strings through rod deformation, the transmission ratio continuously adapts to varying load conditions. Mathematical models of the twisted string actuator with continuously variable transmission are derived and experimentally validated, demonstrating a 2.1-fold transmission ratio variation from 0.1 kg to 1.5 kg loads. Application in an anthropomorphic robot finger showcases a 6.2-fold transmission ratio change between unloaded and loaded states. Our twisted string actuator with continuously variable transmission offers unparalleled advantages in weight, cost, simplicity, compliance, and continuous transmission ratio adjustability, making it highly suitable for robotic systems.
- 18 May 2024
- Published by World Scientific Pub Co Pte Ltd in Modern Physics Letters B
- Vol. 39 (05)
Conductive polymer composites-enable self-sensing twisted string actuators
Twisted string actuators (TSAs) are innovative linear soft actuators that can mimic natural muscle contraction. However, obtaining feedback on their stroke requires cumbersome external sensors that compromise their compliance. We addressed this by developing self-sensing strings using conductive polymer composites (CPCs). The CPC strings exhibit electrical resistance changes in response to strain, enabling stroke sensing by the strings themselves. We fabricated CPCs strings with varying concentrations of multi-walled carbon nanotubes (MWCNTs). Characterization revealed excellent conductivity, tensile strength exceeding 30 N, tunable strain sensitivity via MWCNTs concentration variation, as well as stable and repeatable strain-dependent resistance changes. Optimization via a high-strength core fiber enabled the CPCs strings to withstand over 6[ ]kg loading with enhanced stroke and minimal resistance variation. We achieved at least a 97.8% linear correlation between resistance change rate and contraction rate in twisting experiments. This research provides a self-contained stroke sensor compatible with high-load soft TSAs, overcoming limitations of external sensors. The simple yet effective sensing mechanism could spur adoption of TSA in robotics.
- 18 May 2024
- Published by World Scientific Pub Co Pte Ltd in Modern Physics Letters B
- Vol. 39 (05)
Conductive polymer composites-enable self-sensing twisted string actuators
Twisted string actuators (TSAs) are innovative linear soft actuators that can mimic natural muscle contraction. However, obtaining feedback on their stroke requires cumbersome external sensors that compromise their compliance. We addressed this by developing self-sensing strings using conductive polymer composites (CPCs). The CPC strings exhibit electrical resistance changes in response to strain, enabling stroke sensing by the strings themselves. We fabricated CPCs strings with varying concentrations of multi-walled carbon nanotubes (MWCNTs). Characterization revealed excellent conductivity, tensile strength exceeding 30 N, tunable strain sensitivity via MWCNTs concentration variation, as well as stable and repeatable strain-dependent resistance changes. Optimization via a high-strength core fiber enabled the CPCs strings to withstand over 6[ ]kg loading with enhanced stroke and minimal resistance variation. We achieved at least a 97.8% linear correlation between resistance change rate and contraction rate in twisting experiments. This research provides a self-contained stroke sensor compatible with high-load soft TSAs, overcoming limitations of external sensors. The simple yet effective sensing mechanism could spur adoption of TSA in robotics.
- Open Access
- 14 September 2023
- Published by MDPI AG in Biomimetics
- Vol. 8 (5) , 425
Lightweight Soft Robotic Glove with Whole-Hand Finger Motion Tracking for Hand Rehabilitation in Virtual Reality
Soft robotic gloves have attracted significant interest in hand rehabilitation in the past decade. However, current solutions are still heavy and lack finger-state monitoring and versatile treatment options. To address this, we present a lightweight soft robotic glove actuated by twisted string actuators (TSA) that provides whole-hand finger motion tracking. We have developed a virtual reality environment for hand rehabilitation training, allowing users to interact with various virtual objects. Fifteen small inertial measurement units are placed on the glove to predict finger joint angles and track whole-hand finger motion. We performed TSA experiments to identify design and control rules, by understanding how their response varies with input load and voltages. Grasping experiments were conducted to determine the grasping force and range of motion. Finally, we showcase an application of the rehabilitation glove in a Unity-based VR interface, which can actuate the operator’s fingers to grasp different virtual objects.
- 14 September 2023
- Published by MDPI AG in Biomimetics
- Vol. 8 (5) , 425
Open AccessLightweight Soft Robotic Glove with Whole-Hand Finger Motion Tracking for Hand Rehabilitation in Virtual Reality
Soft robotic gloves have attracted significant interest in hand rehabilitation in the past decade. However, current solutions are still heavy and lack finger-state monitoring and versatile treatment options. To address this, we present a lightweight soft robotic glove actuated by twisted string actuators (TSA) that provides whole-hand finger motion tracking. We have developed a virtual reality environment for hand rehabilitation training, allowing users to interact with various virtual objects. Fifteen small inertial measurement units are placed on the glove to predict finger joint angles and track whole-hand finger motion. We performed TSA experiments to identify design and control rules, by understanding how their response varies with input load and voltages. Grasping experiments were conducted to determine the grasping force and range of motion. Finally, we showcase an application of the rehabilitation glove in a Unity-based VR interface, which can actuate the operator’s fingers to grasp different virtual objects.
- Open Access
- 15 November 2021
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 22 (22) , 12342
A Comparison Study on the Magneto-Responsive Properties and Swelling Behaviors of a Polyacrylamide-Based Hydrogel Incorporating with Magnetic Particles
This work investigates the mechanical properties, microstructures, and water-swelling behavior of a novel hydrogel filled with magnetic particles. The nanoparticles of magnetite (Fe3O4) and the micro-particles of carbonyl iron (CI) were selected and filled into a polyacrylamide (PAAM) hydrogel matrix to create two types of magnetic hydrogels. The isotropy and anisotropy of magnetic hydrogels are also presented in this study. The isotropic samples were cured without applying a magnetic field (MF), and the anisotropic samples were cured by applying an MF in the direction perpendicular to the thickness of the samples. The effects of the size, content, and inner structures of magnetic particles on the magneto-responsive and swelling properties of magnetic hydrogels were investigated. It was found that the magnetorheological (MR) effect of anisotropic samples was apparently higher than that of isotropic samples, and the hydrogels with CI exhibited a noticeable MR effect than those with Fe3O4. The storage modulus can be enhanced by increasing the filler content and size, forming an anisotropic structure, and applying an external MF. In addition, the magnetic hydrogels also have a swelling ability that can be tuned by varying the content and size of the particle fillers.
- 15 November 2021
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 22 (22) , 12342
Open AccessA Comparison Study on the Magneto-Responsive Properties and Swelling Behaviors of a Polyacrylamide-Based Hydrogel Incorporating with Magnetic Particles
This work investigates the mechanical properties, microstructures, and water-swelling behavior of a novel hydrogel filled with magnetic particles. The nanoparticles of magnetite (Fe3O4) and the micro-particles of carbonyl iron (CI) were selected and filled into a polyacrylamide (PAAM) hydrogel matrix to create two types of magnetic hydrogels. The isotropy and anisotropy of magnetic hydrogels are also presented in this study. The isotropic samples were cured without applying a magnetic field (MF), and the anisotropic samples were cured by applying an MF in the direction perpendicular to the thickness of the samples. The effects of the size, content, and inner structures of magnetic particles on the magneto-responsive and swelling properties of magnetic hydrogels were investigated. It was found that the magnetorheological (MR) effect of anisotropic samples was apparently higher than that of isotropic samples, and the hydrogels with CI exhibited a noticeable MR effect than those with Fe3O4. The storage modulus can be enhanced by increasing the filler content and size, forming an anisotropic structure, and applying an external MF. In addition, the magnetic hydrogels also have a swelling ability that can be tuned by varying the content and size of the particle fillers.