TPThanh Nhan Phan

Thanh Nhan Phan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Thanh Nhan Phan has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Production capacity forecasting model: A data approach in the apparel industry

    by Song Thanh Quynh Le, Thanh Nhi Huynh Thi, Thanh Nhan Phan, Mai Ha Phan N

    In the clothing industry, a sector facing increasingly stringent demands regarding productivity, costs, and delivery schedules, the application of machine learning to forecast production capacity has become an essential management requirement. This study focuses on developing a production capacity forecasting model by analyzing the interplay between clothing order characteristics and sewing line parameters. The Naive Bayes model provides a probabilistic framework for classifying expected production capacity into distinct levels; consequently, the model’s output offers a clear basis for planners to assess capacity-related risks and make informed decisions regarding resource allocation and line balancing. Specifically, the forecasting results can support decisions concerning workforce requirements, production scheduling, sewing line assignments, and delivery planning. The research also demonstrates the potential of machine learning as a decision-support tool, transforming historical production data into actionable insights to inform practical plans. These findings will enable fashion enterprises to optimize resources, meet rigorous customer demands, and mitigate risks throughout the production process.

  • Open Access

    Experimental test to analyze and evaluate the exergy and energy efficiency of the AHU in the Waterchiller system

    by Van Cuong Bui, Duc Khuyen Nguyen, Thanh Nhan Phan

    Experimental study to determine the impact of changing AHU operating parameters on exergy and energy efficiency in the water chiller system. The study used both an experimental method and theoretical calculations, with a Trane-brand chiller system with a cooling capacity of 25,3 kW. The results showed that when the supply air temperature increased from 295 K to 299 K, the heat exchanger's exergy consumption ( ) decreased from 0.2 kW to about 0.05 kW. The exergy consumption of the heat exchanger ( ) and the exergy flow of the return air to the AHU ( ) were almost constant, maintained at about 0.95 kW and 0.8 kW, showing that the efficiency of the heat exchanger and the exergy of the ambient air were relatively stable, not much affected by changes in ambient temperature. When the inlet water temperature ( ) increases from 284 K to 289 K. The water exergy flow ( ) decreases linearly from about 1.3 kW to about 0.8 kW. In addition, this study also evaluates the impact of changing the chilled water pump frequency and air flow rate on energy efficiency. The results indicate that the optimal operating point is not at the maximum frequency but at about 45 Hz, at which the cooling capacity reaches 7,764 kW.

  • Open Access

    Current Status and Analysis of the Solution of Greening in the Textile Industry in Vietnam

    by Thanh Nhan Phan, Song Thanh Quynh Le

    Textile and garment production is one of the essential industries contributing to creating jobs for millions of workers and providing Vietnam's leading source of GDP revenue. The production process of the textile industry also has many impacts on the economy, society, and the environment, not only in Vietnam but also in most countries around the world. In the textile and Garment industry, freshwater consumption accounts for nearly 4%, and water pollution accounts for about 20% worldwide. According to the Vietnam Textile and Apparel Association, the energy consumption of textiles accounts for up to 8% of the energy consumption compared with the energy of the entire industry. It emits about 5 million tons of CO2 per year. Therefore, solutions to green the textile industry, such as designing and building factories in a green and sustainable direction, lighting solutions, optimal production process systems, using energy-saving equipment, and alternative forms of renewable energy are some of the leading critical factors to reducing energy consumption would be analyzed, evaluated and provided optimal solutions for the goal of greening in the textile industry and progress towards the target of net zero emissions by 2050.


  • Open Access

    Forecasting Model of Shrinkage in Circular Knitted Fabric Using Decision Tree Analysis

    by Song Thanh Quynh Le, Thi Kim Hue Trinh, Thanh Nhan Phan

    Controlling and ensuring product quality are significant in any production department, especially in the textile and clothing industry. Ensuring fabric shrinkage meets customer requirements constitutes a critical factor in evaluating product quality in the knitted fabric production process. However, fabric shrinkage depends on the order‘s specifications, such as loop length, fabric weight, material composition, longitudinal density, and transverse density. This complexity makes it challenging to control and ensure the fabric quality according to customer requirements. This study will describe the characteristics of each specification factor and explore its influence on fabric shrinkage. Finally, data mining techniques develop a forecasting model based on input parameters. The prediction model results will support production managers in estimating and promptly adjusting process parameters to achieve the expected quality levels.

  • Open Access

    A Review on Condensation Process of Refrigerants in Horizontal Microfin Tubes: A Typical Example

    by Thanh Nhan Phan

    Heat transfer performance of refrigerant on the condensation process is very important in the designing of condensation equipment, especially in air conditioning and refrigeration systems. The outstanding advantages of microfin tubes are reducing the weight and size of condensers and also reducing the amount of refrigerant on the system. Reviewing the general concept of condensation and detailing the formation of flow pattern map that is also the procedure to determine heat transfer coefficient and pressure drop during condensation process of refrigerant inside the horizontal microfin tubes would be considered. Also, a typical example will be presented to illustrate a detailed procedure to calculate the value of heat transfer coefficient and pressure drop during the condensation process in horizontal microfin tubes. The data results show that microfin tube J60 with 60 number of fins inside 8.96 mm inner diameter, 0.2 mm height of fin, 40o of apex angle and 18o of helix angle, the condensation procedure of R1234ze at 35°C, heat flux of 8.62 kW/m2, and mass flux of 222 kg/m2s that could be estimated with heat transfer coefficient would be reduced from 8160.4 [W/m2 K] to 1413.8 [W/m2 K] follow with quality x changes from 0.99 to 0.01, and the maximum pressure drop of this process is 3173.8 [Pa/m].

  • Open Access

    A Review on Convective Boiling Heat Transfer of Refrigerants in Horizontal Microfin-Tubes: A Typical Example

    by Thanh Nhan Phan, Van Hung Tran

    Understanding the Heat transfer performance of refrigerant for convective boiling in horizontal microfin tube and smooth tube is place an importance role on the designing of evaporator, the main equipment on refrigeration system. Reviewing the general concept especially the theory of boiling in the tube, the formation of the flow pattern map, the calculating procedure for heat transfer coefficient and pressure drop during boiling process of refrigerant in microfin tube. Besides, a typical example will be presented more detail in step by step to define the heat transfer coefficient and pressure drop for one working condition to estimate the data results without doing experiments.

  • Open Access

    An experimental study for drying Pisum sativum on an electric dryer and a heat pump dryer

    by Thanh Nhan Phan, Van Hung Tran, Nikola Kaloyanov, Merima Zlateva

    A study of drying parameters on the drying process of Pisum Sativum bean was carried out. The effects of drying temperature of moisture air from 40°C to 80°C on the drying time and on the drying kinetics were demonstrated not only on conventional electric dryers but also on heat pump dryers. Besides, checking the steady operation of the heat pump dryer was also considered. The results show that, when temperature rises, the shorter time and the faster removal of moisture content can be obtained for both dryer systems. Drying in an electric heater at 80°C took only 1 hour 45 minutes, but the broken skin of pea seeds happened. The comparison of heat pump dryer and electric dryer was presented with the shorter drying time on heat pump than electric dryer as a result of removing water vapor from moisture air at the evaporator of heat pump, it led to the reduction of specific humidity of air entering the drying chamber. And the last impressive result which can be seen is that the drying rate of a heat pump is higher than an electric dryer at the same drying temperatures beside the energy consumption of electric dryer is 2.76 times as much as that of heat pump dryer.

  • Open Access

    Comparison between R134a and R1234ze(E) during Flow Boiling in Microfin Tubes

    by Andrea Lucchini, Igor M. Carraretto, Thanh N. Phan, Paola G. Pittoni, Luigi P. M. Colombo

    Environmental concerns are forcing the replacement of commonly used refrigerants, and finding new fluids is a top priority. Soon the R134a will be banned, and the hydro-fluoro-olefin (HFO) R1234ze(E) has been indicated as an alternative due to its smaller global warming potential (GWP) and shorter atmospheric lifetime. Nevertheless, for an optimal replacement, its thermo-fluid-dynamic characteristics have to be assessed. Flow boiling experiments (saturation temperature Tsat = 5 °C, mass flux G = 65 ÷ 222 kg·m−2·s−1, mean quality xm = 0.15 ÷ 0.95, quality changes ∆x = 0.06 ÷ 0.6) inside a microfin tube were performed to compare the pressure drop per unit length and the heat transfer coefficient provided by the two fluids. The results were benchmarked for some correlations. In commonly adopted operating conditions, the two fluids show a very similar behavior, while benchmark showed that some correlations are available to properly predict the pressure drop for both fluids. However, only one is satisfactory for the heat transfer coefficient. In conclusion, R1234ze(E) proved to be a suitable drop-in replacement for the R134a, whereas further efforts are recommended to refine and adapt the available predictive models.