AZArkadiusz Ziółkowski

Arkadiusz Ziółkowski

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Arkadiusz Ziółkowski has a total of 9 co-authors. Here are the top co-authors by number of shared publications:

  • Magdalena Kasprowicz

    Department of Biomedical Engineering, Faculty of Fundamental Problems of Technology, Wroclaw University of Science and Technology, Wroclaw, Poland

    4 shared publications
  • Marek Czosnyka

    Division of Neurosurgery, Department of Clinical Neurosciences, Addenbrooke's Hospital, University of Cambridge, Cambridge, United Kingdom

    2 shared publications
  • Marek Czosnyka

    Department of Clinical Neurosciences, Division of Neurosurgery, Brain Physics Laboratory, University of Cambridge, Cambridge, UK

    2 shared publications
  • Zofia Czosnyka

    Division of Neurosurgery, Department of Clinical Neurosciences, Addenbrooke's Hospital, University of Cambridge, Cambridge, UK

    2 shared publications
  • Agata Pudełko

    Wroclaw University of Science and Technology

    1 shared publication
  • Agnieszka Kazimierska

    Department of Biomedical Engineering, Faculty of Fundamental Problems of Technology, Wroclaw University of Science and Technology, Wroclaw, Poland

    1 shared publication

Latest Publications

  • Open Access

    Analysis of time delay between non-invasively measured pulse oscillations in cerebral macro- and microcirculation

    by Marta Hendler, Arkadiusz Ziółkowski, Tomasz Sozański, Marek Czosnyka, Magdalena Kasprowicz

    Objective: Integration of cerebral blood macrocirculation and microcirculation form a crucial aspect of global cerebral bood flow. Our study aimed to investigate time delay between pulse oscillations of cerebral blood flow velocity (FV) and total hemoglobin concentration (tHb) acquired via transcranial Doppler ultrasonography (TCD) and functional near-infrared spectroscopy (fNIRS), respectively. Additionally, we compared time-related characteristics with cerebral arterial time constant (τ). Approach: The study involved monitoring of FV, tHb, arterial blood pressure (ABP) and end-tidal CO2 (EtCO2) during 5 minutes of rest (normocapnia) and 5 minutes of controlled hypercapnia in 36 healthy subjects (age: 24 years, Q1-Q3: 21-27 years, 15 females). Onset time delay (onset TD) was defined as the time offset between onsets of FV and tHb pulses, and time to tHb max (TTM) as a time difference between the FV pulse onset and tHb pulse maximum. τ was calculated as a product of cerebrovascular compliance and resistance. Onset TD and TTM were compared between normocapnia and hypercapnia, and their associations with τ were assessed. Main results: Onset TD was consistently positive (0.075 s, Q1-Q3: 0.065-0.108 s). Onset TD and τ were significantly shorter in hypercapnia (0.075 s vs 0.071 s, pS=0.452, pS=0.364, p=0.03), hypercapnia (RS=0.407, p=0.01) and in terms of relative changes (RS=0.421, p=0.01). Significance: There is a time delay between cerebral macro- and microcirculation, which becomes shorter as the cerebral vasculature dilates in hypercapnia.


  • Open Access

    Brain blood flow pulse analysis may help to recognize individuals who suffer from hydrocephalus

    by Arkadiusz Ziółkowski, Magdalena Kasprowicz, Marek Czosnyka, Zofia Czosnyka

    Background: Normal pressure hydrocephalus (NPH) is often associated with altered cerebral blood flow. Recent research with the use of the ultrasonic method suggests specific changes in the shape of cardiac-related cerebral arterial blood volume (CaBV) pulses in NPH patients. Our study aims to provide a quantitative analysis of the shape of CaBV pulses, estimated based on transcranial Doppler ultrasonography (TCD) in NPH patients and healthy individuals. Methods: The CaBV pulses were estimated using TCD cerebral blood flow velocity signals recorded from probable NPH adults and age-matched healthy individuals at rest. The shape of the CaBV pulses was compared to a triangular shape with 27 similarity parameters calculated for every reliable CaBV pulse and compared between patients and volunteers. The diagnostic accuracy of the most prominent parameter for NPH classification was evaluated using the area under the receiver operating characteristic curve (AUC). Results: The similarity parameters were calculated for 31 probable NPH patients (age: 59 years (IQR: 47, 67 years), 14 females) and 23 healthy volunteers (age: 54 years (IQR: 43, 61 years), 18 females). Eighteen of 27 parameters were different between healthy individuals and NPH patients (p < 0.05). The most prominent differences were found for the ascending slope of the CaBV pulse with the AUC equal to 0.87 (95% confidence interval: 0.77, 0.97, p < 0.001). Conclusions: The findings suggest that in NPH, the ascending slope of the CaBV pulse had a slower rise, was more like a straight line, and generally was less convex than in volunteers. Prospective research is required to verify the clinical utility of these findings.


  • Open Access

    Analysis of relative changes in pulse shapes of intracranial pressure and cerebral blood flow velocity

    by Arkadiusz Ziółkowski, Agata Pudełko, Agnieszka Kazimierska, Zofia Czosnyka, Marek Czosnyka, Magdalena Kasprowicz

    Objective. Analysis of relative changes in the shapes of pulse waveforms of intracranial pressure (ICP) and transcranial Doppler cerebral blood flow velocity (CBFV) may provide information on intracranial compliance. We tested this hypothesis, introducing an index named the ratio of pulse slopes (RPS) that is based on inclinations of the ascending parts of the ICP and CBFV pulse waveforms. It has hypothetically a simple interpretation: a value of 1 indicates good compliance and a value less than 1, reduced compliance. Here, we investigated the usefulness of RPS for assessment of intracranial compliance. Approach. ICP and CBFV signals recorded simultaneously in 30 normal-pressure hydrocephalus patients during infusion tests were retrospectively analysed. CBFV was measured in the middle cerebral artery. Changes in RPS during the test were compared with changes in the height ratio of the first and second peak of the ICP pulse (P1/P2) and the shape of the ICP pulse was classified from normal (1) to pathological (4). Values are medians (lower, upper quartiles). Main results. There was a significant correlation between baseline RPS and intracranial elasticity ( R = −0.55, p = 0.0018). During the infusion tests, both RPS and P1/P2 decreased with rising ICP [RPS, 0.80 (0.56, 0.92) versus 0.63 (0.44, 0.80), p = 0.00015; P1/P2, 0.58 (0.50, 0.91) versus 0.52 (0.36, 0.71), p = 0.00009] while the ICP pulses became more pathological in shape [class: 3 (2, 3) versus 3 (3, 4), p = 0.04]. The magnitude of the decrease in RPS during infusion was inversely correlated with baseline P1/P2 ( R = −0.40, p < 0.03). Significance. During infusion, the slopes of the ascending parts of ICP and CBFV pulses become increasingly divergent with a shift in opposite directions. RPS seems to be a promising methodological tool for monitoring intracranial compliance with no additional volumetric manipulation required.