Alireza Khorsandi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Alireza Khorsandi has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
Saeed Ghavami Sabouri
Department of Physics, University of Isfahan, Isfahan, Iran
7 shared publicationsZahra Shabani
Department of Physics, University of Isfahan, Isfahan, Iran
4 shared publications- Saeed Ghavami Sabouri
Faculty of Physics, University of Isfahan, Isfahan, Iran
3 shared publications Safoura Karimarji
Department of Physics, University of Isfahan, Hezar Jarib Street, 81746-73441 Isfahan, Iran
3 shared publications- Majid Ebrahim-Zadeh
ICFO-Institut de Ciencies Fotoniques, The Barcelona Institute of Science and Technology, 08860 Castelldefels (Barcelona), Spain
2 shared publications Mohammad Fadil Sawli
2 shared publications
Latest Publications
- Open Access
- 13 June 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Calibration-free physics-informed multi-task residual U-Net for simultaneous denoising and gas pressure retrieval from noisy voigt spectra
We present a machine learning framework based on a one-dimensional U-Net (1D U-Net) that simultaneously performs spectral denoising and pressure estimation within a unified architecture. The model is trained on simulated Voigt profiles of the P(21) CO absorption line over pressures ranging from of 1 mbar to 2 bar. To ensure realistic conditions, simulated spectra are superimposed with experimentally captured noise, making them nearly indistinguishable from real experimental scans and forcing the model to recover clean spectra from noisy inputs. Quantitative assessments indicate excellent reconstruction performance, with a Pearson correlation coefficient (PCC) approaching unity, a signal-to-noise ratio (SNR) exceeding 35 dB, and both mean absolute error (MAE) and mean squared error (MSE) remaining close to zero. The model accurately predicts pressures for 200 unseen spectra using only spectral features, bypassing traditional linewidth analysis. At 1.25 bar, the U-Net yields virtually zero error (AE ≈ 0, SE ≈ 0), demonstrating sub-percent deviation and excellent consistency with the simulated reference. Experimental validation on a difference-frequency generation (DFG) spectrometer confirms robust performance, with ≈ 70% of traces reaching a peak SNR (PSNR) above 34 dB. Pressure estimation from ramp-based scans further demonstrates high accuracy, achieving minimal errors at 539.1 mbar (AEP = 0.002, SEP = 4.0 × 10⁻⁶). These findings establish the 1D U-Net as an efficient and reliable alternative to conventional noise-reduction and pressure-estimation techniques, simplifying mid-infrared spectroscopy workflows while ensuring high fidelity and stability.
- 13 June 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessCalibration-free physics-informed multi-task residual U-Net for simultaneous denoising and gas pressure retrieval from noisy voigt spectra
We present a machine learning framework based on a one-dimensional U-Net (1D U-Net) that simultaneously performs spectral denoising and pressure estimation within a unified architecture. The model is trained on simulated Voigt profiles of the P(21) CO absorption line over pressures ranging from of 1 mbar to 2 bar. To ensure realistic conditions, simulated spectra are superimposed with experimentally captured noise, making them nearly indistinguishable from real experimental scans and forcing the model to recover clean spectra from noisy inputs. Quantitative assessments indicate excellent reconstruction performance, with a Pearson correlation coefficient (PCC) approaching unity, a signal-to-noise ratio (SNR) exceeding 35 dB, and both mean absolute error (MAE) and mean squared error (MSE) remaining close to zero. The model accurately predicts pressures for 200 unseen spectra using only spectral features, bypassing traditional linewidth analysis. At 1.25 bar, the U-Net yields virtually zero error (AE ≈ 0, SE ≈ 0), demonstrating sub-percent deviation and excellent consistency with the simulated reference. Experimental validation on a difference-frequency generation (DFG) spectrometer confirms robust performance, with ≈ 70% of traces reaching a peak SNR (PSNR) above 34 dB. Pressure estimation from ramp-based scans further demonstrates high accuracy, achieving minimal errors at 539.1 mbar (AEP = 0.002, SEP = 4.0 × 10⁻⁶). These findings establish the 1D U-Net as an efficient and reliable alternative to conventional noise-reduction and pressure-estimation techniques, simplifying mid-infrared spectroscopy workflows while ensuring high fidelity and stability.
- 27 May 2026
- Published by Optica Publishing Group in Applied Optics
- Vol. 65 (16) , 5510-5522
Field-validated high-sensitivity distributed mass sensing using a triple-taper-based Φ-OTDR sensor
We propose a phase-sensitive optical time-domain reflectometry (Φ-OTDR) sensor using a triple-tapered fiber structure to enhance loading mass detection sensitivity. The sensor features a 5 m sensing region with three sequential tapers reduced to a 20 µm diameter, strengthening light mechanical interaction compared to a non-tapered fiber. Experimental results show a maximum signal-to-noise ratio (SNR) of 27.16 dB, representing an approximately 30% improvement over a standard 5 m non-tapered sensor, along with a maximum detectable phase shift of 0.168±0.009rad and a mass sensitivity of 0.601±0.017µs/g. Refractive index variations extracted from the Φ-OTDR signal closely agree with theoretical predictions, yielding an average percentage error (APE) of 7.592×10 −3 %. Field validation further confirmed reliability, achieving strong correlation with laboratory benchmarks (RMSE=0.826, MAPE=1.92%), demonstrating consistent and accurate loaded-mass estimation. Field experiments validated sensor performance under realistic conditions using calibrated load masses of simulated animals on sand surfaces above the embedded fiber. The sensor accurately detected and quantified unknown loads, showing excellent agreement between predicted and realistic measurements. These results highlight the enhanced sensitivity, accuracy, and stability of the proposed triple-taper Φ-OTDR sensor for advanced distributed sensing applications.
- 27 May 2026
- Published by Optica Publishing Group in Applied Optics
- Vol. 65 (16) , 5510-5522
Field-validated high-sensitivity distributed mass sensing using a triple-taper-based Φ-OTDR sensor
We propose a phase-sensitive optical time-domain reflectometry (Φ-OTDR) sensor using a triple-tapered fiber structure to enhance loading mass detection sensitivity. The sensor features a 5 m sensing region with three sequential tapers reduced to a 20 µm diameter, strengthening light mechanical interaction compared to a non-tapered fiber. Experimental results show a maximum signal-to-noise ratio (SNR) of 27.16 dB, representing an approximately 30% improvement over a standard 5 m non-tapered sensor, along with a maximum detectable phase shift of 0.168±0.009rad and a mass sensitivity of 0.601±0.017µs/g. Refractive index variations extracted from the Φ-OTDR signal closely agree with theoretical predictions, yielding an average percentage error (APE) of 7.592×10 −3 %. Field validation further confirmed reliability, achieving strong correlation with laboratory benchmarks (RMSE=0.826, MAPE=1.92%), demonstrating consistent and accurate loaded-mass estimation. Field experiments validated sensor performance under realistic conditions using calibrated load masses of simulated animals on sand surfaces above the embedded fiber. The sensor accurately detected and quantified unknown loads, showing excellent agreement between predicted and realistic measurements. These results highlight the enhanced sensitivity, accuracy, and stability of the proposed triple-taper Φ-OTDR sensor for advanced distributed sensing applications.
- 1 January 2026
- Published by IOP Publishing in Journal of Optics
- Vol. 28 (1) , 015402
Development of a dual-tapered Փ-OTDR sensor with enhanced temperature sensitivity and extended dynamic range
A competitive dual-tapered Φ-OTDR sensor is proposed to enhance the sensitivity of the fiber under test. Experimental results demonstrate that employing two 1.5 cm-long tapers with a 20 µ m diameter embedded in a 20 m fiber sensor not only improves overall performance but also increases its efficiency. The sensor was experimentally characterized by immersing the dual-tapered 20 m fiber in a distilled water bath with a gradually increasing temperature starting from 20 °C. It exhibited an extended dynamic temperature range of approximately 20 °C, achieving a minimum temporal shift resolution of 0.14 µ s °C −1 , a minimum detectable phase shift of 3.89 × 10 −3 ± 6 × 10 −4 rad and a minimum detectable sensitivity of 0.01 V °C −1 . However, due to a saturation effect, the operational temperature range of the fabricated Φ-OTDR sensor was limited to below 40 °C. The refractive index measurements obtained from the raw Φ-OTDR signals as a function of temperature were compared with theoretical values, showing a maximum deviation of 1.52 × 10 −2 % at 36 °C. These findings highlight the enhanced performance, precision and reliability of the proposed sensor design.
- 1 January 2026
- Published by IOP Publishing in Journal of Optics
- Vol. 28 (1) , 015402
Development of a dual-tapered Փ-OTDR sensor with enhanced temperature sensitivity and extended dynamic range
A competitive dual-tapered Φ-OTDR sensor is proposed to enhance the sensitivity of the fiber under test. Experimental results demonstrate that employing two 1.5 cm-long tapers with a 20 µ m diameter embedded in a 20 m fiber sensor not only improves overall performance but also increases its efficiency. The sensor was experimentally characterized by immersing the dual-tapered 20 m fiber in a distilled water bath with a gradually increasing temperature starting from 20 °C. It exhibited an extended dynamic temperature range of approximately 20 °C, achieving a minimum temporal shift resolution of 0.14 µ s °C −1 , a minimum detectable phase shift of 3.89 × 10 −3 ± 6 × 10 −4 rad and a minimum detectable sensitivity of 0.01 V °C −1 . However, due to a saturation effect, the operational temperature range of the fabricated Φ-OTDR sensor was limited to below 40 °C. The refractive index measurements obtained from the raw Φ-OTDR signals as a function of temperature were compared with theoretical values, showing a maximum deviation of 1.52 × 10 −2 % at 36 °C. These findings highlight the enhanced performance, precision and reliability of the proposed sensor design.
- 1 August 2025
- Published by IOP Publishing in Journal of Optics
- Vol. 27 (8) , 085502
Thermally-tunable liquid lens as a novel alternative to the classical Z-scan method
This study presents a temperature-tunable liquid lens utilizing silicon oil (SO) to achieve precise focal length modulation without requiring mechanical displacement of the sample, typically required in conventional z-scan methodologies. The lens was fabricated by injecting SO into a cavity formed between two convex glass substrates, with temperature varied from 20 °C to 130 °C to enable a focal length tuning range from 69.30 mm to 77.78 mm, corresponding to an overall change of 8.48 mm. Key performance metrics include a focal length resolution of 7.2 × 10−2 mm, temperature sensitivity of 1 °C, and demonstrated long-term stability under repeated thermal cycling. The lens’s functionality was validated within a z-scan setup, where it replaced fixed-focal-length optics to eliminate sample translation along the z-axis. Nonlinear refractive index measurements of silver nanoparticles dispersed in distilled water at a concentration of 13 mM yielded a value of (−1.03 ± 0.08) × 10−7 cm2 W−1 using the proposed tunable lens, closely matching (−0.97 ± 0.06) × 10−7 cm2 W−1 obtained via the conventional z-scan method. The proposed approach provides a practical modification to the classical Z-scan technique by allowing real-time focal control, which can simplify experimental procedures and potentially improve measurement accuracy.
- 1 August 2025
- Published by IOP Publishing in Journal of Optics
- Vol. 27 (8) , 085502
Thermally-tunable liquid lens as a novel alternative to the classical Z-scan method
This study presents a temperature-tunable liquid lens utilizing silicon oil (SO) to achieve precise focal length modulation without requiring mechanical displacement of the sample, typically required in conventional z-scan methodologies. The lens was fabricated by injecting SO into a cavity formed between two convex glass substrates, with temperature varied from 20 °C to 130 °C to enable a focal length tuning range from 69.30 mm to 77.78 mm, corresponding to an overall change of 8.48 mm. Key performance metrics include a focal length resolution of 7.2 × 10−2 mm, temperature sensitivity of 1 °C, and demonstrated long-term stability under repeated thermal cycling. The lens’s functionality was validated within a z-scan setup, where it replaced fixed-focal-length optics to eliminate sample translation along the z-axis. Nonlinear refractive index measurements of silver nanoparticles dispersed in distilled water at a concentration of 13 mM yielded a value of (−1.03 ± 0.08) × 10−7 cm2 W−1 using the proposed tunable lens, closely matching (−0.97 ± 0.06) × 10−7 cm2 W−1 obtained via the conventional z-scan method. The proposed approach provides a practical modification to the classical Z-scan technique by allowing real-time focal control, which can simplify experimental procedures and potentially improve measurement accuracy.
- 13 May 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (10) , 21393-21412
Integrating DFG spectroscopy with machine learning for direct and accurate gas pressure diagnosis from spectral imagery
We introduce what we believe to be a novel machine learning (ML)-based ResNet algorithm for predicting gas pressure from spectral imagery, eliminating the need for traditional peak fitting. Evaluated using simulated and experimental carbon monoxide (CO) spectra, the model accurately predicts pressures across a wide range (1 mbar - 2 bar), even with noisy data, outperforming conventional methods like PeakFit. The ResNet model demonstrates minimal discrepancies between predicted and actual pressures, achieving a mean absolute error (MAE) of 0.095 and mean squared error (MSE) of 0.009 in simulations, and maximum MAE of 1.2×10−2 and MSE of 1.46×10−4 experimentally below 94 mbar. This approach significantly enhances quantitative spectroscopy by focusing on line shape imagery, showing promising applications in atmospheric science, industrial monitoring, and environmental research. This work is a substantial improvement over our previous models.
- 13 May 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (10) , 21393-21412
Integrating DFG spectroscopy with machine learning for direct and accurate gas pressure diagnosis from spectral imagery
We introduce what we believe to be a novel machine learning (ML)-based ResNet algorithm for predicting gas pressure from spectral imagery, eliminating the need for traditional peak fitting. Evaluated using simulated and experimental carbon monoxide (CO) spectra, the model accurately predicts pressures across a wide range (1 mbar - 2 bar), even with noisy data, outperforming conventional methods like PeakFit. The ResNet model demonstrates minimal discrepancies between predicted and actual pressures, achieving a mean absolute error (MAE) of 0.095 and mean squared error (MSE) of 0.009 in simulations, and maximum MAE of 1.2×10−2 and MSE of 1.46×10−4 experimentally below 94 mbar. This approach significantly enhances quantitative spectroscopy by focusing on line shape imagery, showing promising applications in atmospheric science, industrial monitoring, and environmental research. This work is a substantial improvement over our previous models.
- 28 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 36 (18) , 1157-1160
Robust Identification and Recovery of Obscured CO₂ Absorption Signals Using Deep Machine Learning
We present the efficacy of deep learning (DL) in identifying and recovering the CO2 absorption line from a noisy spectrum. Following a simulation-based assessment of the DL method’s capabilities, it was applied in an experiment utilizing a lock-in amplifier and mechanical chopper as a phase-sensitive detection unit. The results demonstrate that the DL method is fully qualified to replace traditional noise-reduction systems, simplifying spectroscopy while ensuring reliability and intelligence.
- 28 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 36 (18) , 1157-1160
Robust Identification and Recovery of Obscured CO₂ Absorption Signals Using Deep Machine Learning
We present the efficacy of deep learning (DL) in identifying and recovering the CO2 absorption line from a noisy spectrum. Following a simulation-based assessment of the DL method’s capabilities, it was applied in an experiment utilizing a lock-in amplifier and mechanical chopper as a phase-sensitive detection unit. The results demonstrate that the DL method is fully qualified to replace traditional noise-reduction systems, simplifying spectroscopy while ensuring reliability and intelligence.
- 3 April 2024
- Published by Optica Publishing Group in Applied Optics
- Vol. 63 (11) , 2843-2853
Polarization-sensitive optical coherence tomography for birefringence measurement of calcite nonlinear uniaxial crystal
We report on the new application, to the best of our knowledge, of a time -domain optical coherence tomography (TD-OCT) device used to measure the ordinary n o and extraordinary n e indices of calcite birefringence crystal at room temperature. A 1.25 +/- 0.05 mm thick slab of calcite crystal is cut, polished, and used as a sample in the OCT arm. While the calcite slab is axially scanned, the raw carrier ordinary signals that came from its front and rear facets are received and denoised with a set of digital filters. The extraordinary signals are generated by the change of beam polarization using a 90 degrees -rotating polarizer plate. It is found that the wavelet transform is capable of reaching the highest signal-to-noise ratio (SNR) of about 24.50 and 23.91 for denoising the ordinary and extraordinary signals, respectively. Quantitative measurement of n o and n e is carried out by extracting a desired envelope from the denoised signals using standard methods. Average values of 1.660 and 1.444 are obtained for n o and n e , respectively, using the wavelet-denoised signals. The weights of the results are finally searched with ones obtained from two sets of dispersion equations. We found a very good agreement between the wavelet-denoised OCT- and dispersion equation -based values with a very low relative differences of 0.04% and 2.8% for n o and n e , respectively, when the Ghosh equation is used and averaged ones of 1.3% and 4.2% for n o and n e , respectively, when the Zhao et al. equation is applied. (c) 2024 Optica Publishing Group
- 3 April 2024
- Published by Optica Publishing Group in Applied Optics
- Vol. 63 (11) , 2843-2853
Polarization-sensitive optical coherence tomography for birefringence measurement of calcite nonlinear uniaxial crystal
We report on the new application, to the best of our knowledge, of a time -domain optical coherence tomography (TD-OCT) device used to measure the ordinary n o and extraordinary n e indices of calcite birefringence crystal at room temperature. A 1.25 +/- 0.05 mm thick slab of calcite crystal is cut, polished, and used as a sample in the OCT arm. While the calcite slab is axially scanned, the raw carrier ordinary signals that came from its front and rear facets are received and denoised with a set of digital filters. The extraordinary signals are generated by the change of beam polarization using a 90 degrees -rotating polarizer plate. It is found that the wavelet transform is capable of reaching the highest signal-to-noise ratio (SNR) of about 24.50 and 23.91 for denoising the ordinary and extraordinary signals, respectively. Quantitative measurement of n o and n e is carried out by extracting a desired envelope from the denoised signals using standard methods. Average values of 1.660 and 1.444 are obtained for n o and n e , respectively, using the wavelet-denoised signals. The weights of the results are finally searched with ones obtained from two sets of dispersion equations. We found a very good agreement between the wavelet-denoised OCT- and dispersion equation -based values with a very low relative differences of 0.04% and 2.8% for n o and n e , respectively, when the Ghosh equation is used and averaged ones of 1.3% and 4.2% for n o and n e , respectively, when the Zhao et al. equation is applied. (c) 2024 Optica Publishing Group
- 13 March 2024
- Published by IOP Publishing in Journal of Optics
- Vol. 26 (4) , 045503
Effect of water salinity on the focal tuning of an injected liquid lens used to modify the z-scan method
A water-injected liquid lens is fabricated to tune its focal length using the change in water salinity. It is found that when the salinity of water is changed from zero to 34.25%, the focal length can be changed by about 12.6 mm from 73.7 mm to 86.3 mm. A focal length resolution of approximately 0.75 × 10−2 mm and high temporal stability over a long period have been achieved for the lens foci. This lens is then used to modify the z-scan technique where the lens and the sample both remain fixed without displacement. The performance of the fabricated lens is evaluated by nonlinear refractive index measurement of a sample containing 10.82-pH-synthesized Silver nanoparticles suspended in water with 15 mM of concentration. For verification of the results, a nonlinear refractive index of (−10.6 ± 1.0) × 10−7 cm2 W−1 is firstly measured for the sample using a classical z-scan benefiting from a conventional focal-fixed lens. Interestingly, we found out that when the fabricated lens is replaced in the modified z-scan, the nonlinear refractive index of about (−8.1 ± 0.2) × 10−7 cm2 W−1 can be measured, indicating a similarity in the order and small difference in the coefficient compared to the classical z-scan. This outcome highlights the potential capability and simplicity of the fabricated lens in the modification of the classical z-scan technique.
- 13 March 2024
- Published by IOP Publishing in Journal of Optics
- Vol. 26 (4) , 045503
Effect of water salinity on the focal tuning of an injected liquid lens used to modify the z-scan method
A water-injected liquid lens is fabricated to tune its focal length using the change in water salinity. It is found that when the salinity of water is changed from zero to 34.25%, the focal length can be changed by about 12.6 mm from 73.7 mm to 86.3 mm. A focal length resolution of approximately 0.75 × 10−2 mm and high temporal stability over a long period have been achieved for the lens foci. This lens is then used to modify the z-scan technique where the lens and the sample both remain fixed without displacement. The performance of the fabricated lens is evaluated by nonlinear refractive index measurement of a sample containing 10.82-pH-synthesized Silver nanoparticles suspended in water with 15 mM of concentration. For verification of the results, a nonlinear refractive index of (−10.6 ± 1.0) × 10−7 cm2 W−1 is firstly measured for the sample using a classical z-scan benefiting from a conventional focal-fixed lens. Interestingly, we found out that when the fabricated lens is replaced in the modified z-scan, the nonlinear refractive index of about (−8.1 ± 0.2) × 10−7 cm2 W−1 can be measured, indicating a similarity in the order and small difference in the coefficient compared to the classical z-scan. This outcome highlights the potential capability and simplicity of the fabricated lens in the modification of the classical z-scan technique.
- 29 January 2024
- Published by Elsevier in Optical Materials
- Vol. 148
Investigation of optical properties of choline chloride-lactic acid deep eutectic solvent under continuous wave laser irradiation regime
- 29 January 2024
- Published by Elsevier in Optical Materials
- Vol. 148
Investigation of optical properties of choline chloride-lactic acid deep eutectic solvent under continuous wave laser irradiation regime
- 24 July 2023
- Published by Optica Publishing Group in Optics Continuum
- Vol. 2 (8) , 1782-1802
Wide bandwidth THz emission based on two color chirped laser plasma interaction
This study examined the impact of chirping the input pulses on the amplification of a wide bandwidth THz wave emitted from a plasma slab within a range of input wavelengths from 800 nm to 3.9 µm. It was found that in a normal case of interaction when the injected pulses are highly chirped, flowerthorn-like fluctuations raised in the transverse current density of the plasma, and a THz emission with a higher amplitude within a wide band of 50 THz could be reached. Employing the cross-focusing scheme, the amplitude of the THz wave at 3.9 µm is further enhanced to about 43 times the ones obtained at 800 nm when the two-color pulses are weakly chirped down to 3 × 10−4 rad/s2. A significant increase of 233 times received in THz radiation when a weakly-chirped regime of delayed cross-focusing interaction is established and the intensity of the delayed pulse is increased to 1015 W/cm2, beyond the ionization threshold of Argon gas. The profile change of the fundamental and its second-harmonic waves indicated that a flat-top form is capable of enhancing the THz amplitude approximately by 8 times compared to the case when an ordinary Gaussian profile is used. The obtained results have confirmed that a combination of the type of interaction, chirp value, and the profile of inputs is crucial for enlarging the THz magnitude and domain.
- 24 July 2023
- Published by Optica Publishing Group in Optics Continuum
- Vol. 2 (8) , 1782-1802
Wide bandwidth THz emission based on two color chirped laser plasma interaction
This study examined the impact of chirping the input pulses on the amplification of a wide bandwidth THz wave emitted from a plasma slab within a range of input wavelengths from 800 nm to 3.9 µm. It was found that in a normal case of interaction when the injected pulses are highly chirped, flowerthorn-like fluctuations raised in the transverse current density of the plasma, and a THz emission with a higher amplitude within a wide band of 50 THz could be reached. Employing the cross-focusing scheme, the amplitude of the THz wave at 3.9 µm is further enhanced to about 43 times the ones obtained at 800 nm when the two-color pulses are weakly chirped down to 3 × 10−4 rad/s2. A significant increase of 233 times received in THz radiation when a weakly-chirped regime of delayed cross-focusing interaction is established and the intensity of the delayed pulse is increased to 1015 W/cm2, beyond the ionization threshold of Argon gas. The profile change of the fundamental and its second-harmonic waves indicated that a flat-top form is capable of enhancing the THz amplitude approximately by 8 times compared to the case when an ordinary Gaussian profile is used. The obtained results have confirmed that a combination of the type of interaction, chirp value, and the profile of inputs is crucial for enlarging the THz magnitude and domain.