RQRachael W. Quinn

Rachael W. Quinn

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Rachael W. Quinn has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Optimal Temperature Determination in a Canine Model of Hypothermic Circulatory Arrest

    by AlleaBelle Bradshaw, Michelle Carvajal, Shivani Shirodkar, Jace C. Bradshaw, Hawley Helmbrecht, Bruno Dallo Gallo, Hilkiah Suga, Timothy Sank, Lauren Guyer, Priya Digumarti, et al.

  • Tricuspid Anterior and Posterior Patch (TRAPP) Repair of Functional Tricuspid Regurgitation

    by Hannah J. Rando, Rachael W. Quinn, Zachary Darby, Emily L. Larson, Emily Rodriguez, Jin Kook Kang, Ifeanyi Chinedozi, James S. Gammie

    Objective: Annuloplasty is the most common strategy for repair of functional tricuspid regurgitation (FTR) but is not effective in patients with massive/torrential FTR or leaflet tethering. To address the deficits of tricuspid annuloplasty, TRicuspid Anterior and Posterior Patch (TRAPP) repair was developed, which is a pericardial patch augmentation of the anterior and posterior leaflets. Methods: To test this repair, a previously validated ex vivo model in an explanted porcine heart was used, wherein annular and leaflet geometry were evaluated using a 3-dimensional structured light scanner at 4 time points: (1) baseline, (2) induction of FTR, (3) annuloplasty repair, and (4) patch repair. Results: Compared with the regurgitant tricuspid valve, annuloplasty reduced annular circumference (13.7 to 9.5 cm) and area (13.7 vs 6.1 cm 2 ), whereas TRAPP repair did not alter annular dimensions (circumference: 13.7 vs 13.5 cm; area: 13.7 vs 13.6 cm 2 ). Annuloplasty increased leaflet tenting angles (anterior: 53.5° vs 41.0°; posterior: 59.7° vs 48.2°; septal: 38.9° vs 31.4°) whereas TRAPP repair relieved anterior and posterior leaflet tenting (anterior: 28.9° vs 41.0°; posterior: 34.9° vs 48.2°; septal: 33.2° vs 31.4°) and restored geometry comparable to the native tricuspid valve. Central coaptation lengths were greater with TRAPP repair than with annuloplasty for all 3 leaflets (anterior: 12.7 vs 9.5 mm; posterior: 12.2 vs 8.2 mm; septal: 7.4 vs 4.6 mm). Conclusions: Compared with annuloplasty, TRAPP repair yielded greater coaptation length, resolved leaflet tethering, and resulted in a larger annular area that may facilitate durable repair of advanced FTR, which previously would have required replacement.

  • How To Do It: Mitral Valve Translocation

    by Rachael W. Quinn, Chetan Pasrija, Salman Zaheer, Nolan Winicki, James S. Gammie

    Mitral valve translocation (MVT) is a novel procedure that was developed to treat patients with severe, symptomatic, secondary mitral regurgitation (MR). MVT enhances leaflet coaptation by insertion of an autologous pericardial patch interposed between the mitral annulus and the native mitral leaflets. The patch substantially increases total leaflet surface area and creates supranormal coaptation. In addition, it relieves leaflet tethering by transposing the native valve deeper into the ventricle and decreases the circumference of the annulus. The enhanced coaptation produced by MVT may protect against recurrent MR in patients with continued adverse left ventricular remodeling. The procedural steps include detachment of the intact native mitral valve at the annulus, placement of interrupted pledgeted sutures around the annulus to secure the proximal aspect of the patch, and attachment of the native valve to the distal aspect of the patch using running suture. Follow-up of patients who have undergoing MVT is ongoing, with satisfactory short-term results, including sustained MR grades of ≤mild and 14 mm coaptation at 12 months.

  • Translocation of the Mitral Valve in an Acute Large Animal Model

    by Chetan Pasrija, Rachael Quinn, Erik Strauss, Libin Wang, Douglas Tran, Michael N. D’aMbra, James S. Gammie

    Current repair options for functional mitral regurgitation (FMR) are not durable and do not adequately address underlying pathophysiology including leaflet tethering and insufficient coaptation. The feasibility of mitral valve translocation as a repair strategy for FMR was examined in normal swine. Seven pigs (median 62 kg, IQR 55–65 kg) with normal cardiac function were implanted with a 1-cm frustum-shaped pericardial patch inserted between the native mitral annulus and intact mitral leaflets. Operative survival was 100% with no post-procedure mitral stenosis, systolic anterior motion, or central mitral regurgitation observed on echocardiography. Post-translocation mean gradient was 3.5 mmHg (IQR 1.5–4 mmHg); trace or mild suture line leaks on the atrial suture line were noted in 5/7 pigs. Median leaflet coaptation increased from 2.4 (IQR 2.1–4.3 mm) to 12.4 mm (IQR 10.8–13.4 mm) after translocation (P = 0.016). Translocation dramatically increases leaflet coaptation without impairing diastolic function in animals with normal left ventricular function and is a promising technique for repair of FMR. Graphical abstract Implantation of a 1.0-cm circumferential pericardial patch (mitral valve translocation) increases leaflet coaptation in a normal animal model


  • Mitral Valve Translocation: Optimization of Patch Geometry in an Ex Vivo Model of Secondary Mitral Regurgitation

    by Rachael W. Quinn, Chetan Pasrija, Daniel A. Bernstein, Sari D. Holmes, James S. Gammie

    Optimal translocation patch width for functional mitral regurgitation (FMR) treatment was evaluated in an air-filled ex vivo system. FMR was created in 19 isolated swine hearts by annular dilation and papillary muscle displacement. Frustum-shaped pericardial patches of varying widths (Group 1 = 0.5 cm; Group 2 = 1.0 cm; Group 3 = 1.5 cm) were implanted and imaged via a 3D-structured light scanner. Median leaflet coaptation decreased (P < 0.001) from 5.5 ± 2.0 mm at baseline to 2.4 ± 1.3 mm following FMR creation. Translocation repair increased coaptation length over FMR levels by 2.2 mm in Group 1 (P < 0.001), 4.6 mm in Group 2 (P < 0.001), and 4.7 mm in Group 3 (P < 0.001). After repair, no significant differences were found between groups for annular height, circularity index, tenting height, tenting area, and non-coapting surface area. The supranormal coaptation and minimal valve geometric changes support using a 1.0- or 1.5-cm translocation patch for FMR treatment. Graphical abstract Implantation of a 1.0-cm or 1.5-cm circumferential pericardial patch (mitral valve translocation) increases leaflet coaptation length without significantly altering valve geometry.