Amy S. Kapatkin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Amy S. Kapatkin has a total of 106 co-authors. Here are the top co-authors by number of shared publications:
Tanya C. Garcia
Department of Surgical and Radiological Sciences, University of California-Davis, Davis, CA
9 shared publicationsSusan M. Stover
Department of Surgical and Radiological Sciences, University of California-Davis, Davis, CA
6 shared publicationsDavid Sanchez-Migallon Guzman
Department of Medicine and Epidemiology, University of California-Davis, Davis, CA
5 shared publications- Denis J. Marcellin-Little
Department of Surgical and Radiological Sciences, Weill School of Veterinary Medicine, University of California-Davis, Davis, CA
4 shared publications - Po-Yen Chen
Department of Chemical and Biomolecular Engineering, University of Maryland, College Park, USA
4 shared publications Anna M. Massie
Department of Clinical Sciences and Advanced Medicine, University of California-Davis, Philadelphia, PA
3 shared publications
Latest Publications
- Open Access
- 1 January 2025
- Published by American Veterinary Medical Association (AVMA) in American Journal of Veterinary Research
- Vol. 86 (1) , 1-8
Kirschner wire creates more microdamage than standard or acrylic drill bits in the rabbit (Oryctolagus cuniculi) femur
OBJECTIVE: Histologically evaluate damage to rabbit femur after the creation of bicortical 1.5-mm-diameter holes using a standard surgical drill bit, an acrylic drill bit, and a Kirschner wire (K-wire). METHODS: 10 femora (5 pairs) from skeletally mature female intact New Zealand white rabbits were used. The bone diaphyses were divided into 4 locations, systematically undergoing each test (surgical drill bit, acrylic drill bit, K-wire, and intact control). Four pairs were drilled using a mechanical testing machine, and 1 pair was drilled by hand. Cross-sections of the bone were stained en bloc with basic fuchsin for undecalcified histological evaluation. Damaged bone was reported as a percentage of a standardized area and categorized by location (cis- or transcortex), drill contact (entrance or exit of the cortex), and total damage (both cortices). RESULTS: The drilling method (hand vs mechanical testing machine) had no effect on histologic damage, so results were analyzed by combining all data. The K-wire demonstrated the greatest area of cracks/damage compared to both standard surgical and acrylic drill bits, whereas no difference in damage was noted between the 2 drill bits for all variables. CONCLUSIONS: The K-wire and drill bits caused microdamage; K-wire drilling created more microdamage than drill bits. CLINICAL RELEVANCE: The rabbit bone cortex is thin and brittle relative to dogs and cats, leading to failure during and after fracture fixation. The clinical failure of rabbit bone is at least partially caused by drill bits or K-wires causing microcracks.
- 1 January 2025
- Published by American Veterinary Medical Association (AVMA) in American Journal of Veterinary Research
- Vol. 86 (1) , 1-8
Open AccessKirschner wire creates more microdamage than standard or acrylic drill bits in the rabbit (Oryctolagus cuniculi) femur
OBJECTIVE: Histologically evaluate damage to rabbit femur after the creation of bicortical 1.5-mm-diameter holes using a standard surgical drill bit, an acrylic drill bit, and a Kirschner wire (K-wire). METHODS: 10 femora (5 pairs) from skeletally mature female intact New Zealand white rabbits were used. The bone diaphyses were divided into 4 locations, systematically undergoing each test (surgical drill bit, acrylic drill bit, K-wire, and intact control). Four pairs were drilled using a mechanical testing machine, and 1 pair was drilled by hand. Cross-sections of the bone were stained en bloc with basic fuchsin for undecalcified histological evaluation. Damaged bone was reported as a percentage of a standardized area and categorized by location (cis- or transcortex), drill contact (entrance or exit of the cortex), and total damage (both cortices). RESULTS: The drilling method (hand vs mechanical testing machine) had no effect on histologic damage, so results were analyzed by combining all data. The K-wire demonstrated the greatest area of cracks/damage compared to both standard surgical and acrylic drill bits, whereas no difference in damage was noted between the 2 drill bits for all variables. CONCLUSIONS: The K-wire and drill bits caused microdamage; K-wire drilling created more microdamage than drill bits. CLINICAL RELEVANCE: The rabbit bone cortex is thin and brittle relative to dogs and cats, leading to failure during and after fracture fixation. The clinical failure of rabbit bone is at least partially caused by drill bits or K-wires causing microcracks.
- Open Access
- 1 June 2024
- Published by American Veterinary Medical Association (AVMA) in American Journal of Veterinary Research
- Vol. 85 (6) , 1-7
K-wire is more damaging than standard or acrylic drill bits when evaluating torsional properties of rabbit (Oryctolagus cuniculi) femurs
OBJECTIVE: The objective of this study is to compare drilling variables and torsional mechanical properties of rabbit femora after bicortical drilling with a 1.5-mm standard surgical drill bit, acrylic drill bit, and K-wire. SAMPLES: 24 pairs of rabbit femora. METHODS: After drilling under controlled axial displacement rate, each bone was biaxially loaded in compression followed by rapid external torsion to failure. Maximum axial thrust force, maximum drill torque, integral of force and displacement, change in temperature, maximum power spectral density of the torque signal, torque vibration, and torque and angle at the yield and failure points were collected. Pre- and postyield stiffness, yield and failure energies, and postyield energy were calculated. RESULTS: The work required to drill through the cis- and transcortices (integral of force and displacement) was greater for the K-wire, followed by the acrylic and then standard drill bits, respectively. The K-wire demonstrated higher maximum torque than the drill bits at the ciscortex, and the force of drilling was significantly greater. The vibration data was greater with the acrylic and standard drill bits than the K-wire. There was no difference in torsional strength between drilling types. CLINICAL RELEVANCE: Mechanical differences exist between different drill bits and K-wire and demonstrate that the K-wire is overall more damaging than the surgical drill bit.
- 1 June 2024
- Published by American Veterinary Medical Association (AVMA) in American Journal of Veterinary Research
- Vol. 85 (6) , 1-7
Open AccessK-wire is more damaging than standard or acrylic drill bits when evaluating torsional properties of rabbit (Oryctolagus cuniculi) femurs
OBJECTIVE: The objective of this study is to compare drilling variables and torsional mechanical properties of rabbit femora after bicortical drilling with a 1.5-mm standard surgical drill bit, acrylic drill bit, and K-wire. SAMPLES: 24 pairs of rabbit femora. METHODS: After drilling under controlled axial displacement rate, each bone was biaxially loaded in compression followed by rapid external torsion to failure. Maximum axial thrust force, maximum drill torque, integral of force and displacement, change in temperature, maximum power spectral density of the torque signal, torque vibration, and torque and angle at the yield and failure points were collected. Pre- and postyield stiffness, yield and failure energies, and postyield energy were calculated. RESULTS: The work required to drill through the cis- and transcortices (integral of force and displacement) was greater for the K-wire, followed by the acrylic and then standard drill bits, respectively. The K-wire demonstrated higher maximum torque than the drill bits at the ciscortex, and the force of drilling was significantly greater. The vibration data was greater with the acrylic and standard drill bits than the K-wire. There was no difference in torsional strength between drilling types. CLINICAL RELEVANCE: Mechanical differences exist between different drill bits and K-wire and demonstrate that the K-wire is overall more damaging than the surgical drill bit.
- 1 December 2022
- Published by University of Toronto Press Inc. (UTPress) in Journal of Veterinary Medical Education
- Vol. 49 (6) , 778-784
Training Surgical Residents Utilizing an Animal Shelter Fracture Program
Working relationships between veterinary medical teaching hospitals, animal shelters, and rescue groups are one way to increase veterinary students’ and residents’ hands-on training. The goal of this study is to describe the use of a shelter fracture program to improve the surgical skills of surgical residents. In this program, the participating shelter and rescue organizations electronically submit cases. Following evaluation of radiographs and case approval by the orthopedic faculty, the case is scheduled for a physical evaluation. A resident takes primary surgical care together with a fourth-year student rotating through the orthopedic surgery service to ensure the proper pre-, peri-, and post-operative standard of care. All care is overseen by the orthopedic faculty. A veterinary student–run fracture foster program allows students to gain additional experience in the pre-, peri-, and post-operative care of shelter animals. The total number of shelter animals treated during a 9-year period was 373, with a mean annual case load of 41.1 cases (± 10.3). During the same time period, a total of 435 client-owned cases underwent surgical fracture treatment, with a mean annual case load of 48 cases (± 11.7). Surgical resident and student surveys show that this program contributes to their knowledge, skills, and confidence in treating fracture patients. A successful cooperative program provides advanced surgical fracture treatment of shelter animals, improving animals’ quality of life as well as surgical residents’ and veterinary students’ skills training.
- 1 December 2022
- Published by University of Toronto Press Inc. (UTPress) in Journal of Veterinary Medical Education
- Vol. 49 (6) , 778-784
Training Surgical Residents Utilizing an Animal Shelter Fracture Program
Working relationships between veterinary medical teaching hospitals, animal shelters, and rescue groups are one way to increase veterinary students’ and residents’ hands-on training. The goal of this study is to describe the use of a shelter fracture program to improve the surgical skills of surgical residents. In this program, the participating shelter and rescue organizations electronically submit cases. Following evaluation of radiographs and case approval by the orthopedic faculty, the case is scheduled for a physical evaluation. A resident takes primary surgical care together with a fourth-year student rotating through the orthopedic surgery service to ensure the proper pre-, peri-, and post-operative standard of care. All care is overseen by the orthopedic faculty. A veterinary student–run fracture foster program allows students to gain additional experience in the pre-, peri-, and post-operative care of shelter animals. The total number of shelter animals treated during a 9-year period was 373, with a mean annual case load of 41.1 cases (± 10.3). During the same time period, a total of 435 client-owned cases underwent surgical fracture treatment, with a mean annual case load of 48 cases (± 11.7). Surgical resident and student surveys show that this program contributes to their knowledge, skills, and confidence in treating fracture patients. A successful cooperative program provides advanced surgical fracture treatment of shelter animals, improving animals’ quality of life as well as surgical residents’ and veterinary students’ skills training.
- Open Access
- 27 December 2021
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 50 (1) , 56-77
Tissue Engineering of Canine Cartilage from Surgically Debrided Osteochondritis Dissecans Fragments
This study in dogs explored the feasibility of using cartilage fragments removed and discarded during routine palliative surgery for osteochondritis dissecans (OCD) as a source of primary chondrocytes for scaffold-free cartilage tissue-engineering. Primary chondrocytes were obtained from three OCD donors and one age-matched healthy articular cartilage (HAC) donor. After monolayer expansion of primary cells, a three-dimensional spherical suspension culture was implemented. Following this stage, cells were seeded at a high density into custom-made agarose molds that allowed for size and shape-specific constructs to be generated via a method of cellular self-assembling in a scaffold-free environment. Fifty-eight neocartilage constructs were tissue-engineered using this methodology. Neocartilage constructs and native cartilage from shoulder joint were subjected to histological, mechanical, and biochemical testing. OCD and HAC chondrocytes-sourced constructs had uniformly flat morphology and histology consistent with cartilage tissue. Constructs sourced from OCD chondrocytes were 1.5-times (32%) stiffer in compression and 1.3 times (23%) stronger in tension than constructs sourced from HAC chondrocytes and only 8.7-times (81%) less stiff in tension than native tissue. Constructs from both cell sources consistently had lower collagen content than native tissue (22.9%/dry weight [DW] for OCD and 4.1%/DW for HAC vs. 51.1%/DW native tissue). To improve the collagen content and mechanical properties of neocartilage, biological and mechanical stimuli, and thyroid hormone (tri-iodothyronine) were applied to the chondrocytes during the self-assembling stage in two separate studies. A 2.6-fold (62%) increase in compressive stiffness was detected with supplementation of biological stimuli alone and 5-fold (81%) increase with combined biological and mechanical stimuli at 20% strain. Application of thyroid hormone improved collagen content (1.7-times, 33%), tensile strength (1.8-times, 43%), and stiffness (1.3-times, 21%) of constructs, relative to untreated controls. Collectively, these data suggest that OCD chondrocytes can serve as a reliable cell source for cartilage tissue-engineering and that canine chondrocytes respond favorably to biological and mechanical stimuli that have been shown effective in chondrocytes from other animal species, including humans.
- 27 December 2021
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 50 (1) , 56-77
Open AccessTissue Engineering of Canine Cartilage from Surgically Debrided Osteochondritis Dissecans Fragments
This study in dogs explored the feasibility of using cartilage fragments removed and discarded during routine palliative surgery for osteochondritis dissecans (OCD) as a source of primary chondrocytes for scaffold-free cartilage tissue-engineering. Primary chondrocytes were obtained from three OCD donors and one age-matched healthy articular cartilage (HAC) donor. After monolayer expansion of primary cells, a three-dimensional spherical suspension culture was implemented. Following this stage, cells were seeded at a high density into custom-made agarose molds that allowed for size and shape-specific constructs to be generated via a method of cellular self-assembling in a scaffold-free environment. Fifty-eight neocartilage constructs were tissue-engineered using this methodology. Neocartilage constructs and native cartilage from shoulder joint were subjected to histological, mechanical, and biochemical testing. OCD and HAC chondrocytes-sourced constructs had uniformly flat morphology and histology consistent with cartilage tissue. Constructs sourced from OCD chondrocytes were 1.5-times (32%) stiffer in compression and 1.3 times (23%) stronger in tension than constructs sourced from HAC chondrocytes and only 8.7-times (81%) less stiff in tension than native tissue. Constructs from both cell sources consistently had lower collagen content than native tissue (22.9%/dry weight [DW] for OCD and 4.1%/DW for HAC vs. 51.1%/DW native tissue). To improve the collagen content and mechanical properties of neocartilage, biological and mechanical stimuli, and thyroid hormone (tri-iodothyronine) were applied to the chondrocytes during the self-assembling stage in two separate studies. A 2.6-fold (62%) increase in compressive stiffness was detected with supplementation of biological stimuli alone and 5-fold (81%) increase with combined biological and mechanical stimuli at 20% strain. Application of thyroid hormone improved collagen content (1.7-times, 33%), tensile strength (1.8-times, 43%), and stiffness (1.3-times, 21%) of constructs, relative to untreated controls. Collectively, these data suggest that OCD chondrocytes can serve as a reliable cell source for cartilage tissue-engineering and that canine chondrocytes respond favorably to biological and mechanical stimuli that have been shown effective in chondrocytes from other animal species, including humans.
- 7 May 2021
- Published by Wiley in Veterinary Surgery
- Vol. 50 (6) , 1237-1249
Influence of interlocking thread screws to repair simulated adult canine humeral condylar fractures
Objective: To determine the influence of interlocking screw threads on the biomechanical properties of repaired canine humeral condylar fractures.Study Design: Ex vivo biomechanical study.Sample Population: Thirty‐six humeral condyles.Methods: Simulated fractures of the lateral aspect of the humeral condyle were stabilized by a 3.5 mm interlocking thread screw (ITS) or 3.5 mm buttress thread screw placed in lag (BTS‐L) or positional fashion (BTS‐P) and axially loaded at a walk, trot, 2‐mm displacement, and failure cycles. Compact flute drill bits (CFBs) were used for ITS constructs and standard flute drill bits (SFB) for BTS constructs. The effects of bit type on drilling parameters and screw type on screw insertion properties and fragment stability were assessed.Results: CFB produced a 6°C greater temperature increase (p = .042) and required 20 N higher torque (p = .003) than SFB. Insertional torque was greater for ITS than BTS‐P (p = .001) and BTS‐L (p = .001). Condylar fragment rotation at failure was lower in ITS (lsmean ± SE, 8.3° ± 1.9°) than BTS‐L constructs (14.5° ± 2.3°,p = .011). ITS resisted greater loads (1503 ± 105 N) than BTS‐P (1189 ± 99 N,p = .038) but not BTS‐L (1249 ± 123 N,p = .121) constructs.Conclusion: Biomechanical performance of constructs was improved with ITS rather than BTS fixation.Clinical Significance: ITS can be considered for stabilization of humeral condylar fractures in adult dogs.
- 7 May 2021
- Published by Wiley in Veterinary Surgery
- Vol. 50 (6) , 1237-1249
Influence of interlocking thread screws to repair simulated adult canine humeral condylar fractures
Objective: To determine the influence of interlocking screw threads on the biomechanical properties of repaired canine humeral condylar fractures.Study Design: Ex vivo biomechanical study.Sample Population: Thirty‐six humeral condyles.Methods: Simulated fractures of the lateral aspect of the humeral condyle were stabilized by a 3.5 mm interlocking thread screw (ITS) or 3.5 mm buttress thread screw placed in lag (BTS‐L) or positional fashion (BTS‐P) and axially loaded at a walk, trot, 2‐mm displacement, and failure cycles. Compact flute drill bits (CFBs) were used for ITS constructs and standard flute drill bits (SFB) for BTS constructs. The effects of bit type on drilling parameters and screw type on screw insertion properties and fragment stability were assessed.Results: CFB produced a 6°C greater temperature increase (p = .042) and required 20 N higher torque (p = .003) than SFB. Insertional torque was greater for ITS than BTS‐P (p = .001) and BTS‐L (p = .001). Condylar fragment rotation at failure was lower in ITS (lsmean ± SE, 8.3° ± 1.9°) than BTS‐L constructs (14.5° ± 2.3°,p = .011). ITS resisted greater loads (1503 ± 105 N) than BTS‐P (1189 ± 99 N,p = .038) but not BTS‐L (1249 ± 123 N,p = .121) constructs.Conclusion: Biomechanical performance of constructs was improved with ITS rather than BTS fixation.Clinical Significance: ITS can be considered for stabilization of humeral condylar fractures in adult dogs.
- 1 July 2020
- Published by American Veterinary Medical Association (AVMA) in American Journal of Veterinary Research
- Vol. 81 (7) , 557-564
Comparison of torsional properties between a Fixateur Externe du Service de Santé des Armées and an acrylic tie-in external skeletal fixator in a red-tailed hawk (Buteo jamaicensis) synthetic tibiotarsal bone model
OBJECTIVE To compare the torsional mechanical properties of 2 external skeletal fixators (ESFs) placed with 2 intramedullary pin (IP) and transfixation pin (TP) size combinations in a model of rapt...
- 1 July 2020
- Published by American Veterinary Medical Association (AVMA) in American Journal of Veterinary Research
- Vol. 81 (7) , 557-564
Comparison of torsional properties between a Fixateur Externe du Service de Santé des Armées and an acrylic tie-in external skeletal fixator in a red-tailed hawk (Buteo jamaicensis) synthetic tibiotarsal bone model
OBJECTIVE To compare the torsional mechanical properties of 2 external skeletal fixators (ESFs) placed with 2 intramedullary pin (IP) and transfixation pin (TP) size combinations in a model of rapt...
- 15 January 2019
- Published by Georg Thieme Verlag KG in Veterinary and Comparative Orthopaedics and Traumatology
- Vol. 32 (01) , 051-058
Effects of Hole Diameter on Torsional Mechanical Properties of the Rabbit Femur
Objective The aim of this study was to evaluate and compare the effect of three clinically applicable screw hole diameters on rabbit femoral torsional structural properties. Sample Eighteen pairs of skeletally mature New Zealand White rabbit femora (36 bones). Materials and Methods Femora with a bicortical hole at mid-diaphysis from one of the 3-drill bit sizes, 1.1 mm, 1.5 mm, 2.0 mm, and intact bones were studied. Each bone was bi-axially loaded in a servo-hydraulic load frame with the bone positioned so the neutral axis of torsion was aligned with the centre of the bone diaphysis. Axial compression to 35% body weight was applied to represent compression at stance, and rapid external torsion was applied to failure. Torque and angular deformation data were plotted for each test, with pre-yield and post-yield stiffnesses derived. Yield and failure torques and angles were determined, along with calculated yield, failure and post-yield energies. Results Failure torque was reduced compared with that of intact bone; weakened by 37% in 1.1-mm hole models, 53% in 1.5-mm hole models and 65% in 2.0-mm hole models. The torque angular deformation curves lacked plastic deformation. Conclusions and Clinical Relevance This study demonstrates the unique, brittle biomechanics of rabbit bone. Based on data from other species that strength loss of no more than 50% is acceptable when placing orthopaedic implants, no defect greater than 1.1 mm (15% bone diameter) is recommended in rabbit femora.
- 15 January 2019
- Published by Georg Thieme Verlag KG in Veterinary and Comparative Orthopaedics and Traumatology
- Vol. 32 (01) , 051-058
Effects of Hole Diameter on Torsional Mechanical Properties of the Rabbit Femur
Objective The aim of this study was to evaluate and compare the effect of three clinically applicable screw hole diameters on rabbit femoral torsional structural properties. Sample Eighteen pairs of skeletally mature New Zealand White rabbit femora (36 bones). Materials and Methods Femora with a bicortical hole at mid-diaphysis from one of the 3-drill bit sizes, 1.1 mm, 1.5 mm, 2.0 mm, and intact bones were studied. Each bone was bi-axially loaded in a servo-hydraulic load frame with the bone positioned so the neutral axis of torsion was aligned with the centre of the bone diaphysis. Axial compression to 35% body weight was applied to represent compression at stance, and rapid external torsion was applied to failure. Torque and angular deformation data were plotted for each test, with pre-yield and post-yield stiffnesses derived. Yield and failure torques and angles were determined, along with calculated yield, failure and post-yield energies. Results Failure torque was reduced compared with that of intact bone; weakened by 37% in 1.1-mm hole models, 53% in 1.5-mm hole models and 65% in 2.0-mm hole models. The torque angular deformation curves lacked plastic deformation. Conclusions and Clinical Relevance This study demonstrates the unique, brittle biomechanics of rabbit bone. Based on data from other species that strength loss of no more than 50% is acceptable when placing orthopaedic implants, no defect greater than 1.1 mm (15% bone diameter) is recommended in rabbit femora.
- 27 July 2018
- Published by Georg Thieme Verlag KG in Veterinary and Comparative Orthopaedics and Traumatology
- Vol. 31 (S 02) , A1-A25
The Effects of Carprofen and Phycox in Dogs with Naturally Occurring Clinical Elbow Osteoarthritis: A Randomized, Double-Blinded, Multicenter Pilot Study
Introduction: The purpose of this study was to examine the comparative effects of treatment with Phycox, a C-phycocyanin-based nutraceutical or carprofen in dogs with clinical elbow osteoarthritis (OA). Materials and Methods: Twenty-one client-owned dogs with unilateral or bilateral elbow joint OA were selected for the randomized, double-blinded, multicenter study. Two groups were used; treatment group: Phycox, control group: carprofen. All dogs were treated for 24 weeks. Assessments made before and during the treatment period included force plate analysis, accelerometry, goniometry, pain and lameness evaluations, canine brief pain inventories, and synoviocentesis for concentrations of select inflammatory and degradation markers. Statistical analysis was performed using a split-plot ANOVA and Bonferroni corrections post-hoc with significance at p < 0.05. Results: Final enrollments: Phycox group = 10 dogs, carprofen group = 10 dogs. There were no differences between groups in ground reaction forces or clinical lameness scores. The Phycox group recorded greater accelerometer activity at 12 weeks (p = 0.046) and joint extension at 24 weeks (p = 0.0003). Pain scores were lower for the carprofen group at 20 and 24 weeks (p = 0.008, p = 0.001). Synovial concentrations of matrix metalloproteinase-3 were lower in the Phycox group at 24 weeks (p = 0.013), while PGE2 was lower in the carprofen group at 12 and 24 weeks (p = 0.047, p = 0.023). Discussion/Conclusion: Although Phycox and carprofen provide clinical efficacy when treating OA patients, Phycox may provide a greater potential to modulate the biochemical OA environment in the dog. Acknowledgement: Funded by a grant from Dechra. Funding sponsor had no influence on study design, results, or preparation of manuscripts.
- 27 July 2018
- Published by Georg Thieme Verlag KG in Veterinary and Comparative Orthopaedics and Traumatology
- Vol. 31 (S 02) , A1-A25
The Effects of Carprofen and Phycox in Dogs with Naturally Occurring Clinical Elbow Osteoarthritis: A Randomized, Double-Blinded, Multicenter Pilot Study
Introduction: The purpose of this study was to examine the comparative effects of treatment with Phycox, a C-phycocyanin-based nutraceutical or carprofen in dogs with clinical elbow osteoarthritis (OA). Materials and Methods: Twenty-one client-owned dogs with unilateral or bilateral elbow joint OA were selected for the randomized, double-blinded, multicenter study. Two groups were used; treatment group: Phycox, control group: carprofen. All dogs were treated for 24 weeks. Assessments made before and during the treatment period included force plate analysis, accelerometry, goniometry, pain and lameness evaluations, canine brief pain inventories, and synoviocentesis for concentrations of select inflammatory and degradation markers. Statistical analysis was performed using a split-plot ANOVA and Bonferroni corrections post-hoc with significance at p < 0.05. Results: Final enrollments: Phycox group = 10 dogs, carprofen group = 10 dogs. There were no differences between groups in ground reaction forces or clinical lameness scores. The Phycox group recorded greater accelerometer activity at 12 weeks (p = 0.046) and joint extension at 24 weeks (p = 0.0003). Pain scores were lower for the carprofen group at 20 and 24 weeks (p = 0.008, p = 0.001). Synovial concentrations of matrix metalloproteinase-3 were lower in the Phycox group at 24 weeks (p = 0.013), while PGE2 was lower in the carprofen group at 12 and 24 weeks (p = 0.047, p = 0.023). Discussion/Conclusion: Although Phycox and carprofen provide clinical efficacy when treating OA patients, Phycox may provide a greater potential to modulate the biochemical OA environment in the dog. Acknowledgement: Funded by a grant from Dechra. Funding sponsor had no influence on study design, results, or preparation of manuscripts.
- Open Access
- 23 May 2018
- Published by Frontiers Media SA in Frontiers in Veterinary Science
- Vol. 5, 89
Open Screw Placement in a 1.5 mm LCP Over a Fracture Gap Decreases Fatigue Life
Objective: To investigate the influence of plate and screw hole position on the stability of simulated radial fractures stabilized with a 1.5 mm condylar locking compression plate (LCP). Study Design: In vitro mechanical testing of paired cadaveric limbs. Sample Population: Paired radii (n = 7) stabilized with a 1.5 mm condylar LCP with an open screw hole positioned either proximal to (PG), or over (OG), a simulated small fracture gap. Methods: Constructs were cycled in axial compression at a simulated trot load until failure or a maximum of 200,000 cycles. Specimens that sustained 200,000 cycles without failure were then loaded in axial compression in a single cycle to failure. Construct cyclic axial stiffness and gap strain, fatigue life, and residual strength were evaluated and compared between constructs using analysis of variance. Results: Of pairs that had a failure during cyclic loading, OG constructs survived fewer cycles (54,700 ± 60,600) than PG (116,800 ± 49,300). OG constructs had significantly lower initial stiffness throughout cyclic loading and higher gap strain range within the first 1,000 cycles than PG constructs. Residual strength variables were not significantly different between constructs, however yield loads occurred at loads only marginally higher than approximated trot loads. Fatigue life decreased with increasing body weight. Conclusion: Fracture fixation stability is compromised by an open screw hole directly over a fracture gap compared to the open screw hole being buttressed by bone in the model studied. The 1.5 mm condylar LCP may be insufficient stabilization in dogs with appropriate radial geometry but high body weights.
- 23 May 2018
- Published by Frontiers Media SA in Frontiers in Veterinary Science
- Vol. 5, 89
Open AccessOpen Screw Placement in a 1.5 mm LCP Over a Fracture Gap Decreases Fatigue Life
Objective: To investigate the influence of plate and screw hole position on the stability of simulated radial fractures stabilized with a 1.5 mm condylar locking compression plate (LCP). Study Design: In vitro mechanical testing of paired cadaveric limbs. Sample Population: Paired radii (n = 7) stabilized with a 1.5 mm condylar LCP with an open screw hole positioned either proximal to (PG), or over (OG), a simulated small fracture gap. Methods: Constructs were cycled in axial compression at a simulated trot load until failure or a maximum of 200,000 cycles. Specimens that sustained 200,000 cycles without failure were then loaded in axial compression in a single cycle to failure. Construct cyclic axial stiffness and gap strain, fatigue life, and residual strength were evaluated and compared between constructs using analysis of variance. Results: Of pairs that had a failure during cyclic loading, OG constructs survived fewer cycles (54,700 ± 60,600) than PG (116,800 ± 49,300). OG constructs had significantly lower initial stiffness throughout cyclic loading and higher gap strain range within the first 1,000 cycles than PG constructs. Residual strength variables were not significantly different between constructs, however yield loads occurred at loads only marginally higher than approximated trot loads. Fatigue life decreased with increasing body weight. Conclusion: Fracture fixation stability is compromised by an open screw hole directly over a fracture gap compared to the open screw hole being buttressed by bone in the model studied. The 1.5 mm condylar LCP may be insufficient stabilization in dogs with appropriate radial geometry but high body weights.
- 1 April 2018
- Published by American Veterinary Medical Association (AVMA) in American Journal of Veterinary Research
- Vol. 79 (4) , 388-396
Torsional and axial compressive properties of tibiotarsal bones of red-tailed hawks (Buteo jamaicensis)
OBJECTIVE To describe the torsional and axial compressive properties of tibiotarsal bones of red-tailed hawks (Buteo jamaicensis). SAMPLE 16 cadaveric tibiotarsal bones from 8 red-tailed hawks. PROCEDURES 1 tibiotarsal bone from each bird was randomly assigned to be tested in torsion, and the contralateral bone was tested in axial compression. Intact bones were monotonically loaded in either torsion (n = 8) or axial compression (8) to failure. Mechanical variables were derived from load-deformation curves. Fracture configurations were described. Effects of sex, limb side, and bone dimensions on mechanical properties were assessed with a mixed-model ANOVA. Correlations between equivalent torsional and compressive properties were determined. RESULTS Limb side and bone dimensions were not associated with any mechanical property. During compression tests, mean ultimate cumulative energy and postyield energy for female bones were significantly greater than those for male bones. All 8 bones developed a spiral diaphyseal fracture and a metaphyseal fissure or fracture during torsional tests. During compression tests, all bones developed a crushed metaphysis and a fissure or comminuted fracture of the diaphysis. Positive correlations were apparent between most yield and ultimate torsional and compressive properties. CONCLUSIONS AND CLINICAL RELEVANCE The torsional and axial compressive properties of tibiotarsal bones described in this study can be used as a reference for investigations into fixation methods for tibiotarsal fractures in red-tailed hawks. Although the comminuted and spiral diaphyseal fractures induced in this study were consistent with those observed in clinical practice, the metaphyseal disruption observed was not and warrants further research.
- 1 April 2018
- Published by American Veterinary Medical Association (AVMA) in American Journal of Veterinary Research
- Vol. 79 (4) , 388-396
Torsional and axial compressive properties of tibiotarsal bones of red-tailed hawks (Buteo jamaicensis)
OBJECTIVE To describe the torsional and axial compressive properties of tibiotarsal bones of red-tailed hawks (Buteo jamaicensis). SAMPLE 16 cadaveric tibiotarsal bones from 8 red-tailed hawks. PROCEDURES 1 tibiotarsal bone from each bird was randomly assigned to be tested in torsion, and the contralateral bone was tested in axial compression. Intact bones were monotonically loaded in either torsion (n = 8) or axial compression (8) to failure. Mechanical variables were derived from load-deformation curves. Fracture configurations were described. Effects of sex, limb side, and bone dimensions on mechanical properties were assessed with a mixed-model ANOVA. Correlations between equivalent torsional and compressive properties were determined. RESULTS Limb side and bone dimensions were not associated with any mechanical property. During compression tests, mean ultimate cumulative energy and postyield energy for female bones were significantly greater than those for male bones. All 8 bones developed a spiral diaphyseal fracture and a metaphyseal fissure or fracture during torsional tests. During compression tests, all bones developed a crushed metaphysis and a fissure or comminuted fracture of the diaphysis. Positive correlations were apparent between most yield and ultimate torsional and compressive properties. CONCLUSIONS AND CLINICAL RELEVANCE The torsional and axial compressive properties of tibiotarsal bones described in this study can be used as a reference for investigations into fixation methods for tibiotarsal fractures in red-tailed hawks. Although the comminuted and spiral diaphyseal fractures induced in this study were consistent with those observed in clinical practice, the metaphyseal disruption observed was not and warrants further research.