GWGareth Williams

Gareth Williams

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Gareth Williams has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Novel Fit-Flexible Fluorescence Soft Imager: Tri-Sensing of Intensity, Fall-Time, and Life Profile

    by Ali Taimori, Bethany Mills, Erin Gaughan, Aysha Ali, Kevin Dhaliwal, Gareth Williams, Neil Finlayson, James R. Hopgood

    Time-resolved fluorescence imaging techniques, like confocal fluorescence lifetime imaging microscopy, are powerful photonic instrumentation tools of modern science with diverse applications, including: biology, medicine, and chemistry. However, complexities of the systems, both at specimen and device levels, cause difficulties in quantifying soft biomarkers. To address the problems, we first aim to understand and model the underlying photophysics of fluorescence decay curves. For this purpose, we provide a set of mathematical functions, called “life models”, fittable with the real temporal recordings of histogram of photon counts. For each model, an equivalent electrical circuit, called a “life circuit”, is derived for explaining the whole process. In confocal endomicroscopy, the components of excitation laser, specimen, and fluorescence-emission signal as the histogram of photon counts are modelled by a power source, network of resistor-inductor-capacitor circuitry, and multimetre, respectively. We then design a novel pixel-level temporal classification algorithm, called a “fit-flexible approach”, where qualities of “intensity”, “fall-time”, and “life profile” are identified for each point. A model selection mechanism is used at each pixel to flexibly choose the best representative life model based on a proposed Misfit-percent metric. A two-dimensional arrangement of the quantified information detects some kind of structural information. This approach showed a potential of separating microbeads from lung tissue, distinguishing the tri-sensing from conventional methods. We alleviated by 7% the error of the Misfit-percent for recovering the histograms on real samples than the best state-of-the-art competitor. Codes are available online.


  • Fast and Robust Single-Exponential Decay Recovery From Noisy Fluorescence Lifetime Imaging

    by Ali Taimori, Duncan Humphries, Gareth Williams, Kevin Dhaliwal, Neil Finlayson, James Hopgood

    Fluorescence lifetime imaging is a valuable technique for probing characteristics of wide ranging samples and sensing of the molecular environment. However, the desire to measure faster and reduce effects such as photo bleaching in optical photon-count measurements for lifetime estimation lead to inevitable effects of convolution with the instrument response functions and noise, causing a degradation of the lifetime accuracy and precision. To tackle the problem, this paper presents a robust and computationally efficient framework for recovering fluorophore sample decay from the histogram of photon-count arrivals modelled as a decaying single-exponential function. In the proposed approach, the temporal histogram data is first decomposed into multiple bins via an adaptive multi-bin signal representation. Then, at each level of the multi-resolution temporal space, decay information including both the amplitude and the lifetime of a single-exponential function is rapidly decoded based on a novel statistical estimator. Ultimately, a game-theoretic model consisting of two players in an “amplitude-lifetime” game is constructed to be able to robustly recover optimal fluorescence decay signal from a set of fused multi-bin estimates. In addition to theoretical demonstrations, the efficiency of the proposed framework is experimentally shown on both synthesised and real data in different imaging circumstances. On a challenging low photon-count regime, our approach achieves about 28% improvement in bias than the best competing method. On real images, the proposed method processes data on average around 63 times faster than the gold standard least squares fit. Implementation codes are available to researchers.


  • Open Access

    Deep Learning-Assisted Co-registration of Full-Spectral Autofluorescence Lifetime Microscopic Images with H&E-Stained Histology Images

    by Qiang Wang, Susan Fernandes, Gareth O. S. Williams, Neil Finlayson, Ahsan R. Akram, Kevin Dhaliwal, James R. Hopgood, Marta Vallejo

    Autofluorescence lifetime images reveal unique characteristics of endogenous fluorescence in biological samples. Comprehensive understanding and clinical diagnosis rely on co-registration with the gold standard, histology images, which is extremely challenging due to the difference of both images. Here, we show an unsupervised image-to-image translation network that significantly improves the success of the co-registration using a conventional optimisation-based regression network, applicable to autofluorescence lifetime images at different emission wavelengths. A preliminary blind comparison by experienced researchers shows the superiority of our method on co-registration. The results also indicate that the approach is applicable to various image formats, like fluorescence intensity images. With the registration, stitching outcomes illustrate the distinct differences of the spectral lifetime across an unstained tissue, enabling macro-level rapid visual identification of lung cancer and cellular-level characterisation of cell variants and common types. The approach could be effortlessly extended to lifetime images beyond this range and other staining technologies.

  • Open Access

    Full spectrum fluorescence lifetime imaging with 0.5 nm spectral and 50 ps temporal resolution

    by Gareth O. S. Williams, Elvira Williams, Neil Finlayson, Ahmet T. Erdogan, Qiang Wang, Susan Fernandes, Ahsan R. Akram, Kev Dhaliwal, Robert K. Henderson, John M. Girkin, et al.

    The use of optical techniques to interrogate wide ranging samples from semiconductors to biological tissue for rapid analysis and diagnostics has gained wide adoption over the past decades. The desire to collect ever more spatially, spectrally and temporally detailed optical signatures for sample characterization has specifically driven a sharp rise in new optical microscopy technologies. Here we present a high-speed optical scanning microscope capable of capturing time resolved images across 512 spectral and 32 time channels in a single acquisition with the potential for ~0.2 frames per second (256 × 256 image pixels). Each pixel in the resulting images contains a detailed data cube for the study of diverse time resolved light driven phenomena. This is enabled by integration of system control electronics and on-chip processing which overcomes the challenges presented by high data volume and low imaging speed, often bottlenecks in previous systems.