KWKeith Williams

Keith Williams

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Keith Williams has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Investigating the Use of Virtual Reality Headsets for Postural Control Assessment: Instrument Validation Study

    by Brian Sylcott, Chia-Cheng Lin, Keith Williams, Mark Hinderaker

    Background: Accurately measuring postural sway is an important part of balance assessment and rehabilitation. Although force plates give accurate measurements, their costs and space requirements make their use impractical in many situations. Objective: The work presented in this paper aimed to address this issue by validating a virtual reality (VR) headset as a relatively low-cost alternative to force plates for postural sway measurement. The HTC Vive (HTC Corporation) VR headset has built-in sensors that allow for position and orientation tracking, making it a potentially effective tool for balance assessments. Methods: Participants in this study were asked to stand upright on a force plate (NeuroCom; Natus Medical Incorporated) while wearing the HTC Vive. Position data were collected from the headset and force plate simultaneously as participants experienced a custom-built VR environment that covered their entire field of view. The intraclass correlation coefficient (ICC) was used to examine the test-retest reliability of the postural control variables, which included the normalized path length, root mean square (RMS), and peak-to-peak (P2P) value. These were computed from the VR position output data and the center of pressure (COP) data from the force plate. Linear regression was used to investigate the correlations between the VR and force plate measurements. Results: Our results showed that the test-retest reliability of the RMS and P2P value of VR headset outputs (ICC: range 0.285-0.636) was similar to that of the RMS and P2P value of COP outputs (ICC: range 0.228-0.759). The linear regression between VR and COP measures showed significant correlations in RMSs and P2P values. Conclusions: Based on our results, the VR headset has the potential to be used for postural control measurements. However, the further development of software and testing protocols for balance assessments is needed.


  • Open Access

    Investigating the Use of Virtual Reality Headsets for Postural Control Assessment: Instrument Validation Study (Preprint)

    by Brian Sylcott, Chia-Cheng Lin, Keith Williams, Mark Hinderaker

    BACKGROUND Accurately measuring postural sway is an important part of balance assessment and rehabilitation. Although force plates give accurate measurements, their costs and space requirements make their use impractical in many situations. OBJECTIVE The work presented in this paper aimed to address this issue by validating a virtual reality (VR) headset as a relatively low-cost alternative to force plates for postural sway measurement. The HTC Vive (HTC Corporation) VR headset has built-in sensors that allow for position and orientation tracking, making it a potentially effective tool for balance assessments. METHODS Participants in this study were asked to stand upright on a force plate (NeuroCom; Natus Medical Incorporated) while wearing the HTC Vive. Position data were collected from the headset and force plate simultaneously as participants experienced a custom-built VR environment that covered their entire field of view. The intraclass correlation coefficient (ICC) was used to examine the test-retest reliability of the postural control variables, which included the normalized path length, root mean square (RMS), and peak-to-peak (P2P) value. These were computed from the VR position output data and the center of pressure (COP) data from the force plate. Linear regression was used to investigate the correlations between the VR and force plate measurements. RESULTS Our results showed that the test-retest reliability of the RMS and P2P value of VR headset outputs (ICC: range 0.285-0.636) was similar to that of the RMS and P2P value of COP outputs (ICC: range 0.228-0.759). The linear regression between VR and COP measures showed significant correlations in RMSs and P2P values. CONCLUSIONS Based on our results, the VR headset has the potential to be used for postural control measurements. However, the further development of software and testing protocols for balance assessments is needed.

  • Aging Affects the Ability to Process the Optic Flow Stimulations: A Functional Near-Infrared Spectrometry Study

    by Mark Hinderaker, Brian Sylcott, Keith Williams, Chia-Cheng Lin

    Optic flow (OF) has been utilized to investigate the sensory integration of visual stimuli during postural control. It is little known how the OF speed affects the aging brain during the sensory integration process of postural control. This study was to examine the effect of OF speeds on the brain activation using functional near-infrared spectroscopy (fNIRS) and postural sway between younger and older adults. Eleven healthy younger adults (5M/6F, age 22 ± 1-year-old) and ten healthy older adults (4M/6F, age 71 ± 5-year-old) participated in this study. A virtual reality headset was used to provide the OF stimulus at different speeds. A forceplate was used to record the center-of-pressure to compute the amplitude of postural sway (peak-to-peak). Compared with younger adults, older adults showed significantly increased activation in the OF speed of 10 m/s and decreased activation in the OF speed of 20 m/s in the left dorsolateral prefrontal cortex. Older adults also showed decreased activation in the left temporoparietal region (VEST) in the OF speed of 20 m/s. A significant difference in peak-to-peak was found between groups. Our results indicated that age might be associated with the ability to process fast OF stimulation.


  • Natural frequencies of vibration of a fibre supported human tympanic membrane analysed by the finite element method

    by K.R. Williams, T.H.J. Lesser

    A finite element programme developed previously to calculate the natural frequencies of vibration of the human tympanic membrane, has been modified to take into account both natural and geometric rigidities. The natural rigidities take the form of internal membrane stress/strain parameters, while the geometric rigidities are the flexural and membrane stress resultants. The first six natural frequencies calculated are similar to those measured by Laser holography on cadaver membranes and analysed recently by interference techniques. Using a generalized stress/strain constitutional relationship, the natural frequencies were found to be linearly related to the square root of the forces within the membrane. It was proposed in our earlier work, that these internal stresses as well as maintaining the complex shape of the tympanic membrane, serve to enhance its frequency range and response. The role of the radial and circular fibres embedded within the ground substance of the membrane on the frequencies and mode shapes have also been examined by super-imposing beam elements on the semi-loof membrane elements. It was found that the modes of vibration of the membrane are restricted to a fairly simple pattern up to beam moduli values of approximately 50 MPa. Above this beam modulus, the normal mode shape was observed with a gradually increasing complex vibration pattern as the frequency increases. This new treatment of membrane re-enforcement suggests a non-Hookean behaviour of the drum displacements. In order to account for the earlier measured frequencies of Tonndorf & Khanna, the previously proposed internal stress/strain parameters are believed to be less important and have been calculated to be small compared with the membrane modulus.