Yingjie Cai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yingjie Cai has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Zongxing Lu
School of Mechanical Engineering and Automation, Fuzhou University, Fuzhou 350108, China
2 shared publications - Bingxing Chen
Fuzhou University
1 shared publication - Jing Wang
School of Mechanical Engineering and Automation, Fuzhou University, No.2 Xueyuan Road, Fuzhou 350116, China
1 shared publication - Junjie Wang
School of Mechanical Engineering and Automation, Fuzhou University, Fuzhou 350108, China
1 shared publication - Qiuxu Meng
School of Mechanical Engineering and Automation, Fuzhou University, Fuzhou 350108, China
1 shared publication - Zengyu Qing
School of Mechanical Engineering and Automation, Fuzhou University, No.2 Xueyuan Road, Fuzhou 350116, China
1 shared publication
Latest Publications
- Open Access
- 22 October 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (10) , 1966
Experimental Study on Double-Joint Soft Actuator and Its Dexterous Hand
In this paper, we propose a pneumatic double-joint soft actuator based on fiber winding and build a dexterous hand with 11 degrees of freedom. Firstly, soft actuator structural design is carried out according to the actuator driving principle and gives the specific manufacturing process. Then, an experimental analysis of the bending performance of a single soft actuator, including bending angle, speed, and force magnitude, is carried out by building a pneumatic control experimental platform. Finally, a series of dexterous robotic hand-grasping experiments is conducted. Different grasping methods are used to catch the objects and measure the objects’ change in height, length, and rotation angle during the experiment. The results show that the proposed soft actuator is more consistent with the bending rule of human fingers, and that the gestures of the dexterous hand are more imaginable and flexible when grasping objects. The soft actuator can carry out horizontal and vertical movements, and rotation of the object in the dexterous hand, thus achieving better human–computer interaction.
- 22 October 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (10) , 1966
Open AccessExperimental Study on Double-Joint Soft Actuator and Its Dexterous Hand
In this paper, we propose a pneumatic double-joint soft actuator based on fiber winding and build a dexterous hand with 11 degrees of freedom. Firstly, soft actuator structural design is carried out according to the actuator driving principle and gives the specific manufacturing process. Then, an experimental analysis of the bending performance of a single soft actuator, including bending angle, speed, and force magnitude, is carried out by building a pneumatic control experimental platform. Finally, a series of dexterous robotic hand-grasping experiments is conducted. Different grasping methods are used to catch the objects and measure the objects’ change in height, length, and rotation angle during the experiment. The results show that the proposed soft actuator is more consistent with the bending rule of human fingers, and that the gestures of the dexterous hand are more imaginable and flexible when grasping objects. The soft actuator can carry out horizontal and vertical movements, and rotation of the object in the dexterous hand, thus achieving better human–computer interaction.
- Open Access
Elements Influencing sEMG-Based Gesture Decoding: Muscle Fatigue, Forearm Angle and Acquisition Time
The surface Electromyography (sEMG) signal contains information about movement intention generated by the human brain, and it is the most intuitive and common solution to control robots, orthotics, prosthetics and rehabilitation equipment. In recent years, gesture decoding based on sEMG signals has received a lot of research attention. In this paper, the effects of muscle fatigue, forearm angle and acquisition time on the accuracy of gesture decoding were researched. Taking 11 static gestures as samples, four specific muscles (i.e., superficial flexor digitorum (SFD), flexor carpi ulnaris (FCU), extensor carpi radialis longus (ECRL) and finger extensor (FE)) were selected to sample sEMG signals. Root Mean Square (RMS), Waveform Length (WL), Zero Crossing (ZC) and Slope Sign Change (SSC) were chosen as signal eigenvalues; Linear Discriminant Analysis (LDA) and Probabilistic Neural Network (PNN) were used to construct classification models, and finally, the decoding accuracies of the classification models were obtained under different influencing elements. The experimental results showed that the decoding accuracy of the classification model decreased by an average of 7%, 10%, and 13% considering muscle fatigue, forearm angle and acquisition time, respectively. Furthermore, the acquisition time had the biggest impact on decoding accuracy, with a maximum reduction of nearly 20%.
Open AccessElements Influencing sEMG-Based Gesture Decoding: Muscle Fatigue, Forearm Angle and Acquisition Time
The surface Electromyography (sEMG) signal contains information about movement intention generated by the human brain, and it is the most intuitive and common solution to control robots, orthotics, prosthetics and rehabilitation equipment. In recent years, gesture decoding based on sEMG signals has received a lot of research attention. In this paper, the effects of muscle fatigue, forearm angle and acquisition time on the accuracy of gesture decoding were researched. Taking 11 static gestures as samples, four specific muscles (i.e., superficial flexor digitorum (SFD), flexor carpi ulnaris (FCU), extensor carpi radialis longus (ECRL) and finger extensor (FE)) were selected to sample sEMG signals. Root Mean Square (RMS), Waveform Length (WL), Zero Crossing (ZC) and Slope Sign Change (SSC) were chosen as signal eigenvalues; Linear Discriminant Analysis (LDA) and Probabilistic Neural Network (PNN) were used to construct classification models, and finally, the decoding accuracies of the classification models were obtained under different influencing elements. The experimental results showed that the decoding accuracy of the classification model decreased by an average of 7%, 10%, and 13% considering muscle fatigue, forearm angle and acquisition time, respectively. Furthermore, the acquisition time had the biggest impact on decoding accuracy, with a maximum reduction of nearly 20%.