Klaudia Duch
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Klaudia Duch has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Ilona Karpiel
Łukasiewicz Research Network – Krakow Institute of Technology
2 shared publications - Dariusz Komorowski
Faculty of Biomedical Engineering, Department of Medical Informatics and Artificial Intelligence, Silesian University of Technology, Roosevelt 40, 41-800 Zabrze, Poland
1 shared publication - Mirella Urzeniczok
Łukasiewicz Research Network—Krakow Institute of Technology, ul. Zakopiańska 73, 30-418 Krakow, Poland
1 shared publication - Rafał Kurasz
Independent Researcher, 40-007 Katowice, Poland
1 shared publication - Szymon Sieciński
University of Luebeck, Institute of Medical Informatics, Ratzeburger Allee 160, 23562 Lubeck , Germany
1 shared publication - Zofia Kurasz
Institute of Psychology, University of Silesia, 40-007 Katowice, Poland
1 shared publication
Latest Publications
- Open Access
An Assessment of the Freshness of Fruits and Vegetables Through the Utilization of Bioimpedance Spectroscopy (BIS)—A Preliminary Study
This study evaluates the use of bioimpedance spectroscopy (BIS) as a non-invasive method to assess the freshness of fruits and vegetables by measuring impedance, its components, and phase angle. Over nine days, three vegetables (potato, pumpkin, and red pepper) and two fruits (apple and banana) were assessed using the Analog Discovery 3 device, covering a frequency range of 50 Hz to 1 MHz. The results showed a consistent decrease in impedance and an increase in phase angle during ripening, with statistical significance observed for pumpkin and potato (p < 0.05). The findings confirm BIS as an effective, objective, and non-destructive alternative to traditional chemical methods for monitoring freshness, despite challenges such as structural damage in red pepper. This integration of BIS into food quality assessment and healthcare provides a multidisciplinary approach to improving nutrition and health.
Open AccessAn Assessment of the Freshness of Fruits and Vegetables Through the Utilization of Bioimpedance Spectroscopy (BIS)—A Preliminary Study
This study evaluates the use of bioimpedance spectroscopy (BIS) as a non-invasive method to assess the freshness of fruits and vegetables by measuring impedance, its components, and phase angle. Over nine days, three vegetables (potato, pumpkin, and red pepper) and two fruits (apple and banana) were assessed using the Analog Discovery 3 device, covering a frequency range of 50 Hz to 1 MHz. The results showed a consistent decrease in impedance and an increase in phase angle during ripening, with statistical significance observed for pumpkin and potato (p < 0.05). The findings confirm BIS as an effective, objective, and non-destructive alternative to traditional chemical methods for monitoring freshness, despite challenges such as structural damage in red pepper. This integration of BIS into food quality assessment and healthcare provides a multidisciplinary approach to improving nutrition and health.
- Open Access
The Influence of Filters on EEG-ERP Testing: Analysis of Motor Cortex in Healthy Subjects
The raw EEG signal is always contaminated with many different artifacts, such as muscle movements (electromyographic artifacts), eye blinking (electrooculographic artifacts) or power line disturbances. All artifacts must be removed for correct data interpretation. However, various noise reduction methods significantly influence the final shape of the EEG signal and thus its characteristic values, latency and amplitude. There are several types of filters to eliminate noise early in the processing of EEG data. However, there is no gold standard for their use. This article aims to verify and compare the influence of four various filters (FIR, IIR, FFT, NOTCH) on the latency and amplitude of the EEG signal. By presenting a comparison of selected filters, the authors intend to raise awareness among researchers as regards the effects of known filters on latency and amplitude in a selected area—the sensorimotor area.
Open AccessThe Influence of Filters on EEG-ERP Testing: Analysis of Motor Cortex in Healthy Subjects
The raw EEG signal is always contaminated with many different artifacts, such as muscle movements (electromyographic artifacts), eye blinking (electrooculographic artifacts) or power line disturbances. All artifacts must be removed for correct data interpretation. However, various noise reduction methods significantly influence the final shape of the EEG signal and thus its characteristic values, latency and amplitude. There are several types of filters to eliminate noise early in the processing of EEG data. However, there is no gold standard for their use. This article aims to verify and compare the influence of four various filters (FIR, IIR, FFT, NOTCH) on the latency and amplitude of the EEG signal. By presenting a comparison of selected filters, the authors intend to raise awareness among researchers as regards the effects of known filters on latency and amplitude in a selected area—the sensorimotor area.