Lifei Dong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lifei Dong has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Bowen Lv
College of Engineering and Design, Hunan Normal University, Changsha, China
1 shared publication - Houde Dai
Quanzhou Institute of Equipment Manufacturing, Fujian Institute of Research on the Structure of Matter, Chinese Academy of Sciences, Jinjiang, China
1 shared publication - Shijian Su
Department of Electronic Engineering, Chinese University of Hong Kong, Hong Kong
1 shared publication - Shuang Song
School of Robotics and Advanced Manufacture, Harbin Institute of Technology, Shenzhen, China
1 shared publication - Yuangui Chen
Department of Radiation Oncology, Fujian Medical University Union Hospital, Fuzhou, China
1 shared publication
Latest Publications
- 1 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-10
Feasibility Study of Permanent Magnet-Based Tumor Tracking Technique for Precise Lung Cancer Radiotherapy
During lung cancer radiotherapy, tumor motion caused by respiration and heartbeat significantly affects radiotherapy efficacy. The real-time and high-precision tracking of the lung tumor during the radiotherapy process remains a big challenge, as the traditional tracking methods have disadvantages such as slow tracking speed, radiation issue, or tracking and radiotherapy cannot be carried out at the same time. In this study, a magnetic tracking technique based on three permanent magnets was employed to localize the tumor in real-time. Thus the precise lung cancer radiotherapy is achieved by adjusting the acceleration position through the magnetic tracking results. Technical verification shows that the tracked centroid accuracies of the simulated tumor based on both 1- and 3-dipole models were 1.38 ± 0.83 mm, where the tracked tumor diameter accuracy based on the 3-dipole model was 1.51 ± 1.30 mm. The phantom experiment indicates the centroid tracking accuracies of the simulated tumor based on both 1- and 3-dipole models were 0.36 ± 0.16 mm and 2.54 ± 1.02 mm, respectively, where the tumor diameter accuracy based on the 3-dipole model was 2.15 ± 0.78 mm. Hence, this permanent magnet-based tumor tracking technique can effectively improve the performance of robotic radiotherapy. Besides, the radiotherapy object can be further expanded from lung cancer to other cancers such as prostate cancer.
- 1 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-10
Feasibility Study of Permanent Magnet-Based Tumor Tracking Technique for Precise Lung Cancer Radiotherapy
During lung cancer radiotherapy, tumor motion caused by respiration and heartbeat significantly affects radiotherapy efficacy. The real-time and high-precision tracking of the lung tumor during the radiotherapy process remains a big challenge, as the traditional tracking methods have disadvantages such as slow tracking speed, radiation issue, or tracking and radiotherapy cannot be carried out at the same time. In this study, a magnetic tracking technique based on three permanent magnets was employed to localize the tumor in real-time. Thus the precise lung cancer radiotherapy is achieved by adjusting the acceleration position through the magnetic tracking results. Technical verification shows that the tracked centroid accuracies of the simulated tumor based on both 1- and 3-dipole models were 1.38 ± 0.83 mm, where the tracked tumor diameter accuracy based on the 3-dipole model was 1.51 ± 1.30 mm. The phantom experiment indicates the centroid tracking accuracies of the simulated tumor based on both 1- and 3-dipole models were 0.36 ± 0.16 mm and 2.54 ± 1.02 mm, respectively, where the tumor diameter accuracy based on the 3-dipole model was 2.15 ± 0.78 mm. Hence, this permanent magnet-based tumor tracking technique can effectively improve the performance of robotic radiotherapy. Besides, the radiotherapy object can be further expanded from lung cancer to other cancers such as prostate cancer.