Swapna Mansani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Swapna Mansani has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Santoshkumar Hampannavar
REVA University
2 shared publications - Sreejith Sekaran
Department of Electrical Engineering, National Institute of Technology, Silchar, India
2 shared publications - Arup Kumar Goswami
Electrical Engineering Department, National Institute of Technology Silchar, Silchar, India
1 shared publication - C. Nandakumara
Department of Electrical Engineering, National Institute of Technology, Silchar, India
1 shared publication - Debasis Kumar Patel
Electrical Engineering, NIT Silchar, Silchar 788010, Assam, India
1 shared publication - Deepa B
School of Electrical and Electronics Engineering, REVA University, Bengaluru, India
1 shared publication
Latest Publications
- 21 October 2026
- Published by Springer Nature in Electrical Engineering
- Vol. 108 (11) , 457
RNN-coordinated multi-band power system stabilizer for adaptive damping of low-frequency oscillations in interconnected power systems
- 21 October 2026
- Published by Springer Nature in Electrical Engineering
- Vol. 108 (11) , 457
RNN-coordinated multi-band power system stabilizer for adaptive damping of low-frequency oscillations in interconnected power systems
- 19 November 2025
- Published by Springer Nature in Electrical Engineering
- Vol. 108 (1) , 9
Model predictive control-based PV-battery-fed SRM drive with reduced torque ripple
- 19 November 2025
- Published by Springer Nature in Electrical Engineering
- Vol. 108 (1) , 9
Model predictive control-based PV-battery-fed SRM drive with reduced torque ripple
- 15 December 2024
- Published by Springer Nature
- p. 173-181
Position Sensorless Speed Control of SRM Using ANFIS
- 15 December 2024
- Published by Springer Nature
- p. 173-181
Position Sensorless Speed Control of SRM Using ANFIS
- Open Access
- 25 September 2024
- Published by MDPI AG in World Electric Vehicle Journal
- Vol. 15 (10) , 432
Smart Monitoring of Microgrid-Integrated Renewable-Energy-Powered Electric Vehicle Charging Stations Using Synchrophasor Technology
With the growing concern over climate change and energy security, the Government of India expedited enhancing the share of renewable energy (RE) derived from solar, wind and biomass sources within the energy blend. In this paper, a techno-economic and environmental analysis of a microgrid-integrated electric vehicle charging stations fueled by renewable energy is proposed for a typical area in the State of Karnataka, South India. The power transaction with the grid and the sell-back price to the national grid were investigated. Carbon emissions were also assessed, and 128,406 CO2 kg/Yr can be saved in the grid-connected mode. Also, in this work, different scenarios such as injecting active power, reactive power, and active and reactive power, and injecting active and absorbing reactive power to the grid are comprehensively assessed. Out of four types, type 3 (inject real and reactive power) provides significant reduction in power losses by up to 80.99%. The synchrophasor-technology-based monitoring method is adopted in order to enhance the microgrid system’s overall performance. The execution times for different cases with distributed generators (DGs) and electric vehicle charging stations (EVCSs) for conventional systems and micro-phasor measurement units (µPMU) were observed to be 19.07 s and 5.64 s, respectively, which is well accepted in the case of online monitoring.
- 25 September 2024
- Published by MDPI AG in World Electric Vehicle Journal
- Vol. 15 (10) , 432
Open AccessSmart Monitoring of Microgrid-Integrated Renewable-Energy-Powered Electric Vehicle Charging Stations Using Synchrophasor Technology
With the growing concern over climate change and energy security, the Government of India expedited enhancing the share of renewable energy (RE) derived from solar, wind and biomass sources within the energy blend. In this paper, a techno-economic and environmental analysis of a microgrid-integrated electric vehicle charging stations fueled by renewable energy is proposed for a typical area in the State of Karnataka, South India. The power transaction with the grid and the sell-back price to the national grid were investigated. Carbon emissions were also assessed, and 128,406 CO2 kg/Yr can be saved in the grid-connected mode. Also, in this work, different scenarios such as injecting active power, reactive power, and active and reactive power, and injecting active and absorbing reactive power to the grid are comprehensively assessed. Out of four types, type 3 (inject real and reactive power) provides significant reduction in power losses by up to 80.99%. The synchrophasor-technology-based monitoring method is adopted in order to enhance the microgrid system’s overall performance. The execution times for different cases with distributed generators (DGs) and electric vehicle charging stations (EVCSs) for conventional systems and micro-phasor measurement units (µPMU) were observed to be 19.07 s and 5.64 s, respectively, which is well accepted in the case of online monitoring.
- Open Access
- 29 November 2022
- Published by Hindawi Limited in International Transactions on Electrical Energy Systems
- Vol. 2022, 1-18
Fast Flexible Direct Power Flow for Unbalanced and Balanced Distribution Systems
The study proposes a fast flexible direct power flow solution for radial distribution systems and a fast flexible direct weakly meshed power flow solution for weakly meshed distribution systems. The algorithm is based on the direct forward sweep power flow solution, which is an updated version of the backward/forward sweep solution. The fast flexible direct power flow uses a unique conversion matrix (CM) to rapidly determine the power flow solution. The inverted conversion matrix and its slide-modified matrix are used to solve the power flow problem in a single forward sweep step, which is a novel feature of this work. To ensure the invertibility of the conversion matrix, it is constructed to have a small condition number and a determinant of minus one, and all of its eigenvalues must be equal to that of minus one. Additionally, by modifying the conversion matrix to accommodate the loop branch using the break-point idea, a new weakly meshed conversion matrix (WMCM) is generated with the same following modification as for the radial network and employed in the fast flexible direct weakly meshed power flow (FFDWMPF) solution for the weakly meshed distribution network. The usage of a single matrix in the power flow solution and advanced direct techniques decreases the number of iterations and CPU execution time when MATLAB programming is executed. Furthermore, the proposed method is flexible enough to incorporate any changes in the radial or weakly meshed distribution system just by incorporating the changes in the CM and WMCM for any radial or weakly meshed system. Moreover, the robustness of FFDPF and FFDWMPF is evaluated under various loading scenarios on balanced radial and weakly meshed distribution networks. Finally, to validate the proposed algorithm, the proposed strategy is applied to numerous balanced and unbalanced distribution systems.
- 29 November 2022
- Published by Hindawi Limited in International Transactions on Electrical Energy Systems
- Vol. 2022, 1-18
Open AccessFast Flexible Direct Power Flow for Unbalanced and Balanced Distribution Systems
The study proposes a fast flexible direct power flow solution for radial distribution systems and a fast flexible direct weakly meshed power flow solution for weakly meshed distribution systems. The algorithm is based on the direct forward sweep power flow solution, which is an updated version of the backward/forward sweep solution. The fast flexible direct power flow uses a unique conversion matrix (CM) to rapidly determine the power flow solution. The inverted conversion matrix and its slide-modified matrix are used to solve the power flow problem in a single forward sweep step, which is a novel feature of this work. To ensure the invertibility of the conversion matrix, it is constructed to have a small condition number and a determinant of minus one, and all of its eigenvalues must be equal to that of minus one. Additionally, by modifying the conversion matrix to accommodate the loop branch using the break-point idea, a new weakly meshed conversion matrix (WMCM) is generated with the same following modification as for the radial network and employed in the fast flexible direct weakly meshed power flow (FFDWMPF) solution for the weakly meshed distribution network. The usage of a single matrix in the power flow solution and advanced direct techniques decreases the number of iterations and CPU execution time when MATLAB programming is executed. Furthermore, the proposed method is flexible enough to incorporate any changes in the radial or weakly meshed distribution system just by incorporating the changes in the CM and WMCM for any radial or weakly meshed system. Moreover, the robustness of FFDPF and FFDWMPF is evaluated under various loading scenarios on balanced radial and weakly meshed distribution networks. Finally, to validate the proposed algorithm, the proposed strategy is applied to numerous balanced and unbalanced distribution systems.