AWAndreas Wank

Andreas Wank

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Andreas Wank has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • B. Wielage

    Lehrstuhl für Verbundwerkstoffe, Fakultät für Maschinenbau, Technische Universität Chemnitz, 09107 Chemnitz, Germany

    1 shared publication
  • Brian G. Stewart

    Department of Electronic and Electrical Engineering, University of Strathclyde, Glasgow G1 1XQ, UK

    1 shared publication
  • Frank Trommer

    Institute of Mechanical Engineering, Hochschule Magdeburg-Stendal, Breitscheidstraße 2, 39114 Magdeburg, Germany

    1 shared publication
  • Fulin Fan

    School of Electrical Engineering and Automation, Harbin Institute of Technology, Harbin 150001, China

    1 shared publication
  • S. Ahrens

    Lehrstuhl für Verbundwerkstoffe, Fakultät für Maschinenbau, Technische Universität Chemnitz, 09107 Chemnitz, Germany

    1 shared publication
  • Thomas Grund

    Materials and Surface Engineering, Faculty of Mechanical Engineering, Institute of Materials Science and Engineering, Chemnitz University of Technology, Chemnitz, Germany

    1 shared publication

Latest Publications

  • Open Access

    Pantograph Arc Location Estimation Using Resonant Frequencies in DC Railway Power Systems

    by Fulin Fan, Andreas Wank, Yljon Seferi, Brian G. Stewart

    Pantograph arcing in electrified railway systems not only reduces the power collection quality of a locomotive but can also damage pantograph strips and overhead lines (OHLs). Most research detects pantograph-to-OHL arcs based on onboard voltage/current measurements, pantograph cameras, and so on. The use of onboard voltage/current data, though being cost-effective, rarely reflects arc locations along OHLs. This article develops an arc positioning method, which matches the position-dependent resonant frequency (RF) of an OHL with the RF extracted from voltage measurements in a pantograph arc event. A particular 20-km DC railway line supplied by two substations is first modelled in MATLAB/Simulink, with the model effectiveness being assessed based on voltage measurements in an arc event. Then, the OHL-related RFs estimated by the model are validated by the Tableau formula and discussed alongside impacts on RFs based on line models, locomotive locations, and line lengths. These evaluations permit the generation of an RF curve that links OHL-related RFs with arc locations. The arc positioning method is tested based on the pantograph arc events presumed at various positions along the 20-km line, showing errors within 0.2 km at certain locations. The ability to determine arc locations will permit periodic inspections to be performed on the determined line sections.


  • Cold gas sprayed filler coatings for brazing of light alloys

    by B. Wielage, T. Grund, S. Ahrens, A. Wank, F. Trommer

    Application of cold gas spraying to the deposition of braze filler coatings has been investigated. Different light weight alloy substrates, i.e. aluminium AA1050, AA3005, AA5754, AA7022, magnesium AZ91 and titanium Ti–6Al–4V, were used. Filler coating materials depend on the substrate melting temperature. Therefore, for aluminium alloys Al–12Si zinc based fillers are used for AZ91 pure zinc and for Ti–6Al–4V different Cu–Ni blends are used. Cold gas spraying process parameters are varied with regard to process gas (nitrogen) temperature and pressure, powder feedrate and spray distance. Correlation of the process characteristics to economical aspects is given. The viability of the filler coatings produced is illustrated by different optimised brazing/soldering processes. In the case of aluminium braze joints a full metallographical investigation was carried out by optical and scanning electron microscopy as well as EDX analyses. The results obtained are compared with those of conventional filler material additions.