Hongtu Cheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hongtu Cheng has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Ju Tang
State Key Laboratory of Power Grid Environmental Protection, School of Electrical Engineering and Automation, Wuhan University, Wuhan, China
4 shared publications - Xiaoxing Zhang
Hubei University of Technology
4 shared publications - Yin Zhang
Hubei Engineering Research Center for Safety Monitoring of New Energy and Power Grid Equipment, Hubei University of Technology, Wuhan, China
3 shared publications - Fuping Zeng
State Key Laboratory of Power Grid Environmental Protection, School of Electrical Engineering and Automation, Wuhan University, Wuhan 430072, China
2 shared publications - Song Xiao
State Key Laboratory of Power Grid Environmental Protection School of Electrical Engineering and Automation Wuhan University Hubei China
2 shared publications - Bing Luo
State Key Laboratory of Radio Frequency Heterogeneous Integration, College of Electronics and Information Engineering, Shenzhen University, Shenzhen, China
1 shared publication
Latest Publications
- Open Access
- 1 October 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (10)
Research on corona discharge detection by fluorescent optical fiber in multi-insulation media atmosphere
This study investigates the performance of a fluorescence-based optical fiber sensor in nitrogen, air, SF6, and 30%SF6/70%N2 across varying gas pressures. Three characteristic parameters-maximum pulse amplitude, pulse count, and total pulse amplitude-were used to evaluate partial discharge (PD) activity. The results show that all media exhibit fast pulse rise times (100–200 ns), while SF6 and its mixture present the longest fall times (up to 7300 ns). In SF6-based gases, pulse count and total amplitude decrease exponentially with pressure and increase consistently with applied voltage. In contrast, maximum amplitude is highly variable and less reliable. This study reveals distinct PD signal behaviors under different media and conditions, and identifies stable, voltage-sensitive indicators suitable for discharge severity assessment. These findings support the application of fiber-optic sensors in complex insulation monitoring scenarios.
- 1 October 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (10)
Open AccessResearch on corona discharge detection by fluorescent optical fiber in multi-insulation media atmosphere
This study investigates the performance of a fluorescence-based optical fiber sensor in nitrogen, air, SF6, and 30%SF6/70%N2 across varying gas pressures. Three characteristic parameters-maximum pulse amplitude, pulse count, and total pulse amplitude-were used to evaluate partial discharge (PD) activity. The results show that all media exhibit fast pulse rise times (100–200 ns), while SF6 and its mixture present the longest fall times (up to 7300 ns). In SF6-based gases, pulse count and total amplitude decrease exponentially with pressure and increase consistently with applied voltage. In contrast, maximum amplitude is highly variable and less reliable. This study reveals distinct PD signal behaviors under different media and conditions, and identifies stable, voltage-sensitive indicators suitable for discharge severity assessment. These findings support the application of fiber-optic sensors in complex insulation monitoring scenarios.
- Open Access
- 17 January 2023
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 8 (4) , 690-697
SF 6 decomposition behaviour under partial discharge of typical insulation defects in gas‐solid insulated valve‐side bushing of converter transformer
In this paper we investigated SF 6 decomposition behaviour of typical insulation defects in gas‐solid insulated converter transformer valve‐side bushing under partial discharge (PD). Additionally, we compared the results with that of gas insulated switchgear (GIS). The results indicated that SF 6 decomposition behaviour varies with the insulation defects type. For metal protrusion defects, the proportion ranking of CO 2 and SO 2 can be related to whether the needle tip is wrapped with epoxy resin‐impregnated paper (ERIP). The proportion of carbon‐containing products is much higher under contamination defect than under other defects. Moreover, the proportion of carbon‐containing components is higher under flashover condition than under PD condition and is accompanied by the appearance of H 2 S and CS 2 . However, the yield of SO 2 F 2 is always low. Compared to negative DC voltages, positive DC voltages have a higher proportion of carbon‐containing components, mainly in the form of more CO 2 and less SOF 2 . Compared to the PD decomposition behaviour of typical insulation defects in GIS, when PD involves ERIP, the proportion of carbon‐containing products, especially CO 2 , is significant higher, while the proportion of sulphur containing products, especially SO 2 F 2 , is lower.
- 17 January 2023
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 8 (4) , 690-697
Open AccessSF 6 decomposition behaviour under partial discharge of typical insulation defects in gas‐solid insulated valve‐side bushing of converter transformer
In this paper we investigated SF 6 decomposition behaviour of typical insulation defects in gas‐solid insulated converter transformer valve‐side bushing under partial discharge (PD). Additionally, we compared the results with that of gas insulated switchgear (GIS). The results indicated that SF 6 decomposition behaviour varies with the insulation defects type. For metal protrusion defects, the proportion ranking of CO 2 and SO 2 can be related to whether the needle tip is wrapped with epoxy resin‐impregnated paper (ERIP). The proportion of carbon‐containing products is much higher under contamination defect than under other defects. Moreover, the proportion of carbon‐containing components is higher under flashover condition than under PD condition and is accompanied by the appearance of H 2 S and CS 2 . However, the yield of SO 2 F 2 is always low. Compared to negative DC voltages, positive DC voltages have a higher proportion of carbon‐containing components, mainly in the form of more CO 2 and less SOF 2 . Compared to the PD decomposition behaviour of typical insulation defects in GIS, when PD involves ERIP, the proportion of carbon‐containing products, especially CO 2 , is significant higher, while the proportion of sulphur containing products, especially SO 2 F 2 , is lower.
- 26 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 29 (4) , 1498-1505
Study on Photoacoustic Spectroscopy Detection of CO in Gas Insulation Equipment
The related regulations for electric power industry stipulate that CO gas is an important component to be detected when analyzing the gas composition of SF6 equipment. In this study, based on the photoacoustic spectroscopy technology, the quantitative gas detection of CO is carried out. Firstly, in order to avoid the cross-interference effects of other component gases on photoacoustic spectroscopy detection of CO, the characteristic absorption spectrum of CO in 4291.5 cm-1 (which’s wavelength is 2330.2nm) is determined. Secondly, the non-resonant photoacoustic cell is optimized in this study. After that, designing and building a trace gas photoacoustic spectroscopy detection platform around the developed photoacoustic cell, using the built detection platform to perform photoacoustic spectroscopy detection of the concentration of CO, obtaining photoacoustic signals of different concentrations of CO, the photoacoustic signals increase linearly as the concentration increases. With SF6 as the background gas, the lower detection limit of CO gas reaches 20.5 ppm, and with N2 as the background gas, it reaches 5.6 ppm. After all, the influence mechanism of the background gas on the photoacoustic signal is studied, based on the influence mechanism, the lower detection limit of CO with the background gas of different mixing ratios of SF6/N2 is predicted. The verified experiment is basically consistent with the predicted results, which proves the accuracy of the forecast. This study provides guidance for the engineering application of CO photoacoustic spectroscopy detection in SF6 equipment.
- 26 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 29 (4) , 1498-1505
Study on Photoacoustic Spectroscopy Detection of CO in Gas Insulation Equipment
The related regulations for electric power industry stipulate that CO gas is an important component to be detected when analyzing the gas composition of SF6 equipment. In this study, based on the photoacoustic spectroscopy technology, the quantitative gas detection of CO is carried out. Firstly, in order to avoid the cross-interference effects of other component gases on photoacoustic spectroscopy detection of CO, the characteristic absorption spectrum of CO in 4291.5 cm-1 (which’s wavelength is 2330.2nm) is determined. Secondly, the non-resonant photoacoustic cell is optimized in this study. After that, designing and building a trace gas photoacoustic spectroscopy detection platform around the developed photoacoustic cell, using the built detection platform to perform photoacoustic spectroscopy detection of the concentration of CO, obtaining photoacoustic signals of different concentrations of CO, the photoacoustic signals increase linearly as the concentration increases. With SF6 as the background gas, the lower detection limit of CO gas reaches 20.5 ppm, and with N2 as the background gas, it reaches 5.6 ppm. After all, the influence mechanism of the background gas on the photoacoustic signal is studied, based on the influence mechanism, the lower detection limit of CO with the background gas of different mixing ratios of SF6/N2 is predicted. The verified experiment is basically consistent with the predicted results, which proves the accuracy of the forecast. This study provides guidance for the engineering application of CO photoacoustic spectroscopy detection in SF6 equipment.
- 28 April 2022
- Published by Elsevier in Optics & Laser Technology
- Vol. 153, 108211
The effect of the photoacoustic Field-Photoacoustic cell coupling term on the performance of the gas detection system
- 28 April 2022
- Published by Elsevier in Optics & Laser Technology
- Vol. 153, 108211
The effect of the photoacoustic Field-Photoacoustic cell coupling term on the performance of the gas detection system
- 14 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-10
Simultaneous Detection of C₂H₂ and CO Based on Cantilever-Enhanced Photoacoustic Spectroscopy
Gas detection based on photoacoustic (PA) spectroscopy has attracted extensive attention due to high sensitivity and portability. Herein, to achieve the simultaneously detection of the transformer oil carbide gases, C 2 H 2 and CO, a gas-detection system based on one cantilever beam sensor and single-pass PA cell was proposed. The infrared light beams were coupled by the coarse wavelength division multiplexer (CWDM) and fiber coupler, the vibration of the cantilever beam was measured by the vibration meter, and the gas detection experiment was carried out. The results showed that cantilever could distinguish multiple kinds of acoustic waves, in the frequency domain, the simultaneous detection of C 2 H 2 and CO can be realized by extracting the fast Fourier transform (FFT) values at 20 and 55 Hz. The system exhibits a good repeatability, and a linear relationship between the pure PA signals and gas concentration was confirmed with the correlation coefficient greater than 0.9. In addition, the pure PA signals also show linear trend with the coupling ratio. The minimum detection limit and resolution of C 2 H 2 are 0.27 and 0.12 per part million (ppm), respectively, when the CWDM is used to couple the light beams, whereas they are 23.42 and 14.94 ppm of CO. Especially, it was found that the PA signals have good superposition whether the modulation frequencies of the external lasers are same or not. This article provides an idea for simultaneous detection of multicomponent in gas mixture.
- 14 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-10
Simultaneous Detection of C₂H₂ and CO Based on Cantilever-Enhanced Photoacoustic Spectroscopy
Gas detection based on photoacoustic (PA) spectroscopy has attracted extensive attention due to high sensitivity and portability. Herein, to achieve the simultaneously detection of the transformer oil carbide gases, C 2 H 2 and CO, a gas-detection system based on one cantilever beam sensor and single-pass PA cell was proposed. The infrared light beams were coupled by the coarse wavelength division multiplexer (CWDM) and fiber coupler, the vibration of the cantilever beam was measured by the vibration meter, and the gas detection experiment was carried out. The results showed that cantilever could distinguish multiple kinds of acoustic waves, in the frequency domain, the simultaneous detection of C 2 H 2 and CO can be realized by extracting the fast Fourier transform (FFT) values at 20 and 55 Hz. The system exhibits a good repeatability, and a linear relationship between the pure PA signals and gas concentration was confirmed with the correlation coefficient greater than 0.9. In addition, the pure PA signals also show linear trend with the coupling ratio. The minimum detection limit and resolution of C 2 H 2 are 0.27 and 0.12 per part million (ppm), respectively, when the CWDM is used to couple the light beams, whereas they are 23.42 and 14.94 ppm of CO. Especially, it was found that the PA signals have good superposition whether the modulation frequencies of the external lasers are same or not. This article provides an idea for simultaneous detection of multicomponent in gas mixture.
- 6 January 2021
- Published by Elsevier in Measurement
- Vol. 174, 108979
The application of fluorescent optical fiber in partial discharge detection of Ring Main Unit
- 6 January 2021
- Published by Elsevier in Measurement
- Vol. 174, 108979
The application of fluorescent optical fiber in partial discharge detection of Ring Main Unit