Hyeon Ho Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hyeon Ho Yang has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Kyoung Joon Kim
Department of Mechanical Design Engineering, Pukyong National University, Busan 48513, Republic of Korea
2 shared publications - Wooheon Noh
Department of Mechanical Design Engineering, Pukyong National University, Busan 48513, Korea
2 shared publications - Avram Bar-Cohen
Department of Mechanical Engineering, University of Maryland, College Park, MD 20742, USA
1 shared publication - Bongtae Han
Department of Mechanical Engineering, University of Maryland, College Park, USA
1 shared publication - Sina Jamilah1 shared publication
Latest Publications
- 28 February 2023
- Published by The Korea Society for Power System Engineering in Journal of Power System Engineering
- Vol. 27 (1) , 14-21
An Investigation on Predicting Natural Convection around Hollow Hybrid Fin Arrays
본 연구에서는 할로우 하이브리드 휜 (HHF) 배열 주변의 자연대류 예측에 대해 조사한다. HHF 배열은 HHF의 엇갈림배열이고, HHF는 방사형 판 휜과 결합된 중공 핀 휜이다. HHF 배열에 대한 CFD 모델이 구축되었고, CFD 해석에 의한 HHF 배열의 열저항 결과와 측정값의 상대비교로 CFD 모델이 검증되었다. 48개의 CFD 케이스가 해석되었고, 그 결과는 HHF 배열의 Nu 상관식을 개발하는 데 활용되었다. 상관식은 Ra 수와 휜 외경, 휜 내경, 휜 공간, 휜 높이 등의 구조 변수의 함수로 정의 되었다. 연구결과는 상관식에 의해 계산된 Nu 값이 CFD에 의해 해석된 Nu 값과 유사함을 보여준다. 또한 CFD 해석 대비 상관식 예측 Nu 값의 평균 차이는 Ra 9000에서 3.5%, 9000Ra60000에서 8% 그리고 60000Ra292000에서 2.8%로 확인되었다.
- 28 February 2023
- Published by The Korea Society for Power System Engineering in Journal of Power System Engineering
- Vol. 27 (1) , 14-21
An Investigation on Predicting Natural Convection around Hollow Hybrid Fin Arrays
본 연구에서는 할로우 하이브리드 휜 (HHF) 배열 주변의 자연대류 예측에 대해 조사한다. HHF 배열은 HHF의 엇갈림배열이고, HHF는 방사형 판 휜과 결합된 중공 핀 휜이다. HHF 배열에 대한 CFD 모델이 구축되었고, CFD 해석에 의한 HHF 배열의 열저항 결과와 측정값의 상대비교로 CFD 모델이 검증되었다. 48개의 CFD 케이스가 해석되었고, 그 결과는 HHF 배열의 Nu 상관식을 개발하는 데 활용되었다. 상관식은 Ra 수와 휜 외경, 휜 내경, 휜 공간, 휜 높이 등의 구조 변수의 함수로 정의 되었다. 연구결과는 상관식에 의해 계산된 Nu 값이 CFD에 의해 해석된 Nu 값과 유사함을 보여준다. 또한 CFD 해석 대비 상관식 예측 Nu 값의 평균 차이는 Ra 9000에서 3.5%, 9000Ra60000에서 8% 그리고 60000Ra292000에서 2.8%로 확인되었다.
- Open Access
- 22 November 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (22) , 11071
Thermal Performance of Cryogenic Micro-Pin Fin Coolers with Two-Phase Liquid Nitrogen Flows
This study experimentally explores the thermofluidic performance of a cryogenic micro-pin fin cooler with two-phase liquid nitrogen flows. The liquid nitrogen cooling system is introduced to investigate the performance of the micro-pin cooler in a cryogenic condition. The result reveals that the nominal value of the base heat transfer coefficients of the micro-pin fin cooler with liquid nitrogen flows, 240 kW/m2-K at a mass flow rate of 2.23 g/s, is an order of magnitude greater than that with FC-72 flows. The result also demonstrates that the base heat transfer coefficient of the micro-pin fin cooler is nearly three times greater than that of the micro-gap cooler, not containing any fins. This study shows the feasibility of the cryogenic micro-pin fin cooler for thermally controlling very high heat density devices such as high-power laser diode bars, of which the heat density can reach 2000 kW/m2.
- 22 November 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (22) , 11071
Open AccessThermal Performance of Cryogenic Micro-Pin Fin Coolers with Two-Phase Liquid Nitrogen Flows
This study experimentally explores the thermofluidic performance of a cryogenic micro-pin fin cooler with two-phase liquid nitrogen flows. The liquid nitrogen cooling system is introduced to investigate the performance of the micro-pin cooler in a cryogenic condition. The result reveals that the nominal value of the base heat transfer coefficients of the micro-pin fin cooler with liquid nitrogen flows, 240 kW/m2-K at a mass flow rate of 2.23 g/s, is an order of magnitude greater than that with FC-72 flows. The result also demonstrates that the base heat transfer coefficient of the micro-pin fin cooler is nearly three times greater than that of the micro-gap cooler, not containing any fins. This study shows the feasibility of the cryogenic micro-pin fin cooler for thermally controlling very high heat density devices such as high-power laser diode bars, of which the heat density can reach 2000 kW/m2.