Hoda Amani Hamedani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hoda Amani Hamedani has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
Haochen Wang
Department of Electrical, Computer, and Systems Engineering, Case Western Reserve University, Cleveland, OH 44106, USA
3 shared publications- Jeffrey R. Capadona
Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, USA
3 shared publications - Allison Hess-Dunning
Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, 44106, USA; Advanced Platform Technology Center, Louis Stokes Cleveland Veterans Affairs Medical Center, Cleveland, OH, 44106, USA
2 shared publications - Grace Burkhart
Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, USA
2 shared publications - Horst A. von Recum
Department of Biomedical Engineering, Case Western Reserve University, Cleveland, USA
2 shared publications Jeffrey R. Capadona
Department of Biomedical Engineering, , Cleveland, OH, United States
2 shared publications
Latest Publications
- Open Access
- 26 June 2026
- Published by Elsevier in Acta Biomaterialia
- Vol. 219, 126-147
Nanostructured Coatings on Soft-Polymer Based Neural Probes for Addressing Neuroinflammation
- 26 June 2026
- Published by Elsevier in Acta Biomaterialia
- Vol. 219, 126-147
Open AccessNanostructured Coatings on Soft-Polymer Based Neural Probes for Addressing Neuroinflammation
- Open Access
- 3 November 2025
- Published by Elsevier in Biomaterials
- Vol. 328, 123834
Antimicrobial coated intracortical probes reduce invading microbe abundance and subsequent neuroinflammation
- 3 November 2025
- Published by Elsevier in Biomaterials
- Vol. 328, 123834
Open AccessAntimicrobial coated intracortical probes reduce invading microbe abundance and subsequent neuroinflammation
- Open Access
- 20 February 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-27
Bacteria invade the brain following intracortical microelectrode implantation, inducing gut-brain axis disruption and contributing to reduced microelectrode performance
Brain-machine interface performance can be affected by neuroinflammatory responses due to blood-brain barrier (BBB) damage following intracortical microelectrode implantation. Recent findings suggest that certain gut bacterial constituents might enter the brain through damaged BBB. Therefore, we hypothesized that damage to the BBB caused by microelectrode implantation could facilitate microbiome entry into the brain. In our study, we found bacterial sequences, including gut-related ones, in the brains of mice with implanted microelectrodes. These sequences changed over time. Mice treated with antibiotics showed a reduced presence of these bacteria and had a different inflammatory response, which temporarily improved microelectrode recording performance. However, long-term antibiotic use worsened performance and disrupted neurodegenerative pathways. Many bacterial sequences found were not present in the gut or in unimplanted brains. Together, the current study established a paradigm-shifting mechanism that may contribute to chronic intracortical microelectrode recording performance and affect overall brain health following intracortical microelectrode implantation.
- 20 February 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-27
Open AccessBacteria invade the brain following intracortical microelectrode implantation, inducing gut-brain axis disruption and contributing to reduced microelectrode performance
Brain-machine interface performance can be affected by neuroinflammatory responses due to blood-brain barrier (BBB) damage following intracortical microelectrode implantation. Recent findings suggest that certain gut bacterial constituents might enter the brain through damaged BBB. Therefore, we hypothesized that damage to the BBB caused by microelectrode implantation could facilitate microbiome entry into the brain. In our study, we found bacterial sequences, including gut-related ones, in the brains of mice with implanted microelectrodes. These sequences changed over time. Mice treated with antibiotics showed a reduced presence of these bacteria and had a different inflammatory response, which temporarily improved microelectrode recording performance. However, long-term antibiotic use worsened performance and disrupted neurodegenerative pathways. Many bacterial sequences found were not present in the gut or in unimplanted brains. Together, the current study established a paradigm-shifting mechanism that may contribute to chronic intracortical microelectrode recording performance and affect overall brain health following intracortical microelectrode implantation.
- Open Access
- 4 October 2024
- Published by MDPI AG in Nanomanufacturing
- Vol. 4 (4) , 187-201
Glucose Oxidation Performance of Zinc Nano-Hexagons Decorated on TiO2 Nanotube Arrays
Electrochemically anodized TiO2 nanotube arrays (NTAs) were used as a support material for the electrodeposition of zinc nanoparticles. The morphology, composition, and crystallinity of the materials were examined using scanning electron microscopy (SEM). Electrochemical impedance spectroscopy (EIS) was performed to evaluate the electrochemical properties of TiO2 NTAs. Annealing post-anodization was shown to be effective in lowering the impedance of the TiO2 NTAs (measured at 1 kHz frequency). Zinc nanohexagons (NHexs) with a mean diameter of ~300 nm and thickness of 10–20 nm were decorated on the surface of TiO2 NTAs (with a pore diameter of ~80 nm and tube length of ~5 µm) via an electrodeposition process using a zinc-containing deep eutectic solvent. EIS and CV tests were performed to evaluate the functionality of zinc-decorated TiO2 NTAs (Zn/TiO2 NTAs) for glucose oxidation applications. The Zn/TiO2 NTA electrocatalysts obtained at 40 °C demonstrated enhanced glucose sensitivity (160.8 μA mM−1 cm−2 and 4.38 μA mM−1 cm−2) over zinc-based electrocatalysts reported previously. The Zn/TiO2 NTA electrocatalysts developed in this work could be considered as a promising biocompatible electrocatalyst material for in vivo glucose oxidation applications.
- 4 October 2024
- Published by MDPI AG in Nanomanufacturing
- Vol. 4 (4) , 187-201
Open AccessGlucose Oxidation Performance of Zinc Nano-Hexagons Decorated on TiO2 Nanotube Arrays
Electrochemically anodized TiO2 nanotube arrays (NTAs) were used as a support material for the electrodeposition of zinc nanoparticles. The morphology, composition, and crystallinity of the materials were examined using scanning electron microscopy (SEM). Electrochemical impedance spectroscopy (EIS) was performed to evaluate the electrochemical properties of TiO2 NTAs. Annealing post-anodization was shown to be effective in lowering the impedance of the TiO2 NTAs (measured at 1 kHz frequency). Zinc nanohexagons (NHexs) with a mean diameter of ~300 nm and thickness of 10–20 nm were decorated on the surface of TiO2 NTAs (with a pore diameter of ~80 nm and tube length of ~5 µm) via an electrodeposition process using a zinc-containing deep eutectic solvent. EIS and CV tests were performed to evaluate the functionality of zinc-decorated TiO2 NTAs (Zn/TiO2 NTAs) for glucose oxidation applications. The Zn/TiO2 NTA electrocatalysts obtained at 40 °C demonstrated enhanced glucose sensitivity (160.8 μA mM−1 cm−2 and 4.38 μA mM−1 cm−2) over zinc-based electrocatalysts reported previously. The Zn/TiO2 NTA electrocatalysts developed in this work could be considered as a promising biocompatible electrocatalyst material for in vivo glucose oxidation applications.
- Open Access
- 3 April 2024
- Published by Frontiers Media SA in Frontiers in Biomaterials Science
- Vol. 3, 1360443
Synergistic antibacterial activity and inhibition of TiO2 nanotube arrays and loaded antibiotics against gram-positive and gram-negative bacteria
Introduction: Implantable medical devices continue to be vulnerable to bacterial infections. The unrelenting formation of antibiotic resistant bacterial strains not only exacerbates these infections but also renders the current treatment strategies impotent. The need is greater than ever for innovative and effective approaches to counteract drug-resistant bacteria. This study examines the innate antibacterial properties of TiO2 nanotube arrays (TNAs) and their ability to locally deliver antibiotics to inactivate gram-positive and gram-negative bacteria, in vitro.Methods: Using a two-step electrochemical anodization process, TNAs with a diameter of ∼100 nm and a length of ∼5 µm were grown on titanium substrates.Results and Discussion: After 24 h of incubation, as-fabricated TNAs showed 100% clearance of Escherichia coli, and 97% clearance of Staphylococcus aureus growth. The antibiotic-loaded TNAs demonstrated sustained slow-release of cefotaxime and imipenem measured over 14 days. In vitro bacterial studies revealed the capability of cefotaxime- and imipenem-loaded TNAs in completely inhibiting the growth with 100% clearance of Klebsiella pneumoniae after 24 and 48 h of incubation. Bacterial inhibition assay revealed a significantly enlarged inhibition zone difference of 18 mm around the imipenem-loaded TNAs against K. pneumoniae compared to the as-fabricated TNAs which was maintained for 7 days with ∼10 μgmL−1 of antibiotic released from the TNAs which was found to be lower than the dose required to completely eradicate multidrug resistant bacteria when used in conjunction with the antibacterial TNAs. The results of our study highlight the potential of TNAs as a versatile platform for addressing treatment strategies related to bacterial infections and antibiotic resistance in implantable medical devices.
- 3 April 2024
- Published by Frontiers Media SA in Frontiers in Biomaterials Science
- Vol. 3, 1360443
Open AccessSynergistic antibacterial activity and inhibition of TiO2 nanotube arrays and loaded antibiotics against gram-positive and gram-negative bacteria
Introduction: Implantable medical devices continue to be vulnerable to bacterial infections. The unrelenting formation of antibiotic resistant bacterial strains not only exacerbates these infections but also renders the current treatment strategies impotent. The need is greater than ever for innovative and effective approaches to counteract drug-resistant bacteria. This study examines the innate antibacterial properties of TiO2 nanotube arrays (TNAs) and their ability to locally deliver antibiotics to inactivate gram-positive and gram-negative bacteria, in vitro.Methods: Using a two-step electrochemical anodization process, TNAs with a diameter of ∼100 nm and a length of ∼5 µm were grown on titanium substrates.Results and Discussion: After 24 h of incubation, as-fabricated TNAs showed 100% clearance of Escherichia coli, and 97% clearance of Staphylococcus aureus growth. The antibiotic-loaded TNAs demonstrated sustained slow-release of cefotaxime and imipenem measured over 14 days. In vitro bacterial studies revealed the capability of cefotaxime- and imipenem-loaded TNAs in completely inhibiting the growth with 100% clearance of Klebsiella pneumoniae after 24 and 48 h of incubation. Bacterial inhibition assay revealed a significantly enlarged inhibition zone difference of 18 mm around the imipenem-loaded TNAs against K. pneumoniae compared to the as-fabricated TNAs which was maintained for 7 days with ∼10 μgmL−1 of antibiotic released from the TNAs which was found to be lower than the dose required to completely eradicate multidrug resistant bacteria when used in conjunction with the antibacterial TNAs. The results of our study highlight the potential of TNAs as a versatile platform for addressing treatment strategies related to bacterial infections and antibiotic resistance in implantable medical devices.
- Open Access
- 8 December 2023
- Published by Springer Nature in MRS Bulletin
- Vol. 49 (4) , 299-309
Flexible multifunctional titania nanotube array platform for biological interfacing
The current work presents a novel flexible multifunctional platform for biological interface applications. The use of titania nanotube arrays (TNAs) as a multifunctional material is explored for soft-tissue interface applications. In vitro biocompatibility of TNAs to brain-derived cells was first examined by culturing microglia cells—the resident immune cells of the central nervous system on the surface of TNAs. The release profile of an anti-inflammatory drug, dexamethasone from TNAs-on-polyimide substrates, was then evaluated under different bending modes. Flexible TNAs-on-polyimide sustained a linear release of anti-inflammatory dexamethasone up to ~11 days under different bending conditions. Finally, microfabrication processes for patterning and transferring TNA microsegments were developed to facilitate structural stability during device flexing and to expand the set of compatible polymer substrates. The techniques developed in this study can be applied to integrate TNAs or other similar nanoporous inorganic films onto various polymer substrates. Impact statement: Titania nanotube arrays (TNAs) are highly tunable and biocompatible structures that lend themselves to multifunctional implementation in implanted devices. A particularly important aspect of titania nanotubes is their ability to serve as nano-reservoirs for drugs or other therapeutic agents that slowly release after implantation. To date, TNAs have been used to promote integration with rigid, dense tissues for dental and orthopedic applications. This work aims to expand the implant applications that can benefit from TNAs by integrating them onto soft polymer substrates, thereby promoting compatibility with soft tissues. The successful direct growth and integration of TNAs on polymer substrates mark a critical step toward developing mechanically compliant implantable systems with drug delivery from nanostructured inorganic functional materials. Diffusion-driven release kinetics and the high drug-loading efficiency of TNAs offer tremendous potential for sustained drug delivery for scientific investigations, to treat injury and disease, and to promote device integration with biological tissues. This work opens new opportunities for developing novel and more effective implanted devices that can significantly improve patient outcomes and quality of life. Graphical
- 8 December 2023
- Published by Springer Nature in MRS Bulletin
- Vol. 49 (4) , 299-309
Open AccessFlexible multifunctional titania nanotube array platform for biological interfacing
The current work presents a novel flexible multifunctional platform for biological interface applications. The use of titania nanotube arrays (TNAs) as a multifunctional material is explored for soft-tissue interface applications. In vitro biocompatibility of TNAs to brain-derived cells was first examined by culturing microglia cells—the resident immune cells of the central nervous system on the surface of TNAs. The release profile of an anti-inflammatory drug, dexamethasone from TNAs-on-polyimide substrates, was then evaluated under different bending modes. Flexible TNAs-on-polyimide sustained a linear release of anti-inflammatory dexamethasone up to ~11 days under different bending conditions. Finally, microfabrication processes for patterning and transferring TNA microsegments were developed to facilitate structural stability during device flexing and to expand the set of compatible polymer substrates. The techniques developed in this study can be applied to integrate TNAs or other similar nanoporous inorganic films onto various polymer substrates. Impact statement: Titania nanotube arrays (TNAs) are highly tunable and biocompatible structures that lend themselves to multifunctional implementation in implanted devices. A particularly important aspect of titania nanotubes is their ability to serve as nano-reservoirs for drugs or other therapeutic agents that slowly release after implantation. To date, TNAs have been used to promote integration with rigid, dense tissues for dental and orthopedic applications. This work aims to expand the implant applications that can benefit from TNAs by integrating them onto soft polymer substrates, thereby promoting compatibility with soft tissues. The successful direct growth and integration of TNAs on polymer substrates mark a critical step toward developing mechanically compliant implantable systems with drug delivery from nanostructured inorganic functional materials. Diffusion-driven release kinetics and the high drug-loading efficiency of TNAs offer tremendous potential for sustained drug delivery for scientific investigations, to treat injury and disease, and to promote device integration with biological tissues. This work opens new opportunities for developing novel and more effective implanted devices that can significantly improve patient outcomes and quality of life. Graphical
- 17 April 2023
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 6 (10) , 8238-8249
Zinc Nanoparticles Electrodeposited on TiO2Nanotube Arrays Using Deep Eutectic Solvents for Implantable Electrochemical Sensors
- 17 April 2023
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 6 (10) , 8238-8249
Zinc Nanoparticles Electrodeposited on TiO2Nanotube Arrays Using Deep Eutectic Solvents for Implantable Electrochemical Sensors
- Open Access
Investigation of Effects of Copper, Zinc, and Strontium Doping on Electrochemical Properties of Titania Nanotube Arrays for Neural Interface Applications
Direct interaction with the neuronal cells is a prerequisite to deciphering useful information in understanding the underlying causes of diseases and functional abnormalities in the brain. Precisely fabricated nanoelectrodes provide the capability to interact with the brain in its natural habitat without compromising its functional integrity. Yet, challenges exist in terms of the high cost and complexity of fabrication as well as poor control over the chemical composition and geometries at the nanoscale, all imposed by inherent limitations of current micro/nanofabrication techniques. In this work, we report on electrochemical fabrication and optimization of vertically oriented TiO2 nanotube arrays as nanoelectrodes for neural interface application. The effects of zinc, strontium, and copper doping on the structural, electrochemical, and biocompatibility properties of electrochemically anodized TiO2 nanotube arrays were investigated. It was found that doping can alter the geometric features, i.e., the length, diameter, and wall thickness, of the nanotubes. Among pure and doped samples, the 0.02 M copper-doped TiO2 nanotubes exhibited superior electrochemical properties, with the highest specific storage capacitance of 130 F g−1 and the lowest impedance of 0.295 KΩ. In addition, regeneration of Vero cells and neurons was highly promoted on (0.02 M) Cu-doped TiO2 nanotube arrays, with relatively small tube diameters and more hydrophilicity, compared with the other two types of dopants. Our results suggest that in situ doping is a promising method for the optimization of various structural and compositional properties of electrochemically anodized nanotube arrays and improvement of their functionality as a potential nanoelectrode platform for neural interfacing.
Open AccessInvestigation of Effects of Copper, Zinc, and Strontium Doping on Electrochemical Properties of Titania Nanotube Arrays for Neural Interface Applications
Direct interaction with the neuronal cells is a prerequisite to deciphering useful information in understanding the underlying causes of diseases and functional abnormalities in the brain. Precisely fabricated nanoelectrodes provide the capability to interact with the brain in its natural habitat without compromising its functional integrity. Yet, challenges exist in terms of the high cost and complexity of fabrication as well as poor control over the chemical composition and geometries at the nanoscale, all imposed by inherent limitations of current micro/nanofabrication techniques. In this work, we report on electrochemical fabrication and optimization of vertically oriented TiO2 nanotube arrays as nanoelectrodes for neural interface application. The effects of zinc, strontium, and copper doping on the structural, electrochemical, and biocompatibility properties of electrochemically anodized TiO2 nanotube arrays were investigated. It was found that doping can alter the geometric features, i.e., the length, diameter, and wall thickness, of the nanotubes. Among pure and doped samples, the 0.02 M copper-doped TiO2 nanotubes exhibited superior electrochemical properties, with the highest specific storage capacitance of 130 F g−1 and the lowest impedance of 0.295 KΩ. In addition, regeneration of Vero cells and neurons was highly promoted on (0.02 M) Cu-doped TiO2 nanotube arrays, with relatively small tube diameters and more hydrophilicity, compared with the other two types of dopants. Our results suggest that in situ doping is a promising method for the optimization of various structural and compositional properties of electrochemically anodized nanotube arrays and improvement of their functionality as a potential nanoelectrode platform for neural interfacing.