Tomáš Veselý
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tomáš Veselý has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Pavel Smrčka
Department of Information and Communication Technologies in Medicine, Faculty of Biomedical Engineering, Czech Technical University in Prague, 128 00 Prague, Czech Republic
6 shared publications - Karel Hana
Department of Information and Communication Technologies in Medicine, Faculty of Biomedical Engineering, Czech Technical University in Prague, 128 00 Prague, Czech Republic
4 shared publications - Martin Vítězník
Department of Information and Communication Technologies in Medicine, Faculty of Biomedical Engineering, Czech Technical University in Prague, 128 00 Prague, Czech Republic
4 shared publications - Radim Kliment
Department of Information and Communication Technologies in Medicine, Faculty of Biomedical Engineering, Czech Technical University in Prague, 128 00 Prague, Czech Republic
4 shared publications - Adam Zach
Department of Information and Communication Technologies in Medicine, Faculty of Biomedical Engineering, Czech Technical University in Prague, 128 00 Prague, Czech Republic
1 shared publication - Dalibor Herman
Cardiocenter, Third Faculty of Medicine (P.O., J.H., D.H., M.H., J.V., V.F., J.K.), Charles University Prague and University Hospital Kralovske Vinohrady, Czech Republic
1 shared publication
Latest Publications
- Open Access
Convolutional Neural Network for Automatic Detection of Segments Contaminated by Interference in ECG Signal
Various types of interfering signals are an integral part of ECGs recorded using wearable electronics, specifically during field monitoring, outside the controlled environment of a medical doctor’s office, or laboratory. The frequency spectrum of several types of interfering signals overlaps significantly with the ECG signal, making effective filtration impossible without losing clinically relevant information. In this article, we proceed from the practical assumption that it is unnecessary to analyze the entire ECG recording in real long-term recordings. Conversely, in the preprocessing phase, it is necessary to detect unreadable segments of the ECG signal. This paper proposes a novel method for automatically detecting unreadable segments distorted by superimposed interference in ECG recordings. The method is based on a convolutional neural network (CNN) and is comparable in quality to annotation performed by a medical expert, but incomparably faster. In a series of controlled experiments, the ECG signal was recorded during physical activities of varying intensities, and individual segments of the recordings were manually annotated based on visual assessment by a medical expert, i.e., divided into four different classes based on the intensity of distortion to the useful ECG signal. A deep convolutional model was designed and evaluated, exhibiting a 87.62% accuracy score and the same F1-score in automatic recognition of segments distorted by superimposed interference. Furthermore, the model exhibits an accuracy and F1-score of 98.70% in correctly identifying segments with visually detectable and non-detectable heart rate. The proposed interference detection procedure appears to be sufficiently effective despite its simplicity. It facilitates subsequent automatic analysis of undisturbed ECG waveform segments, which is crucial in ECG monitoring using wearable electronics.
Open AccessConvolutional Neural Network for Automatic Detection of Segments Contaminated by Interference in ECG Signal
Various types of interfering signals are an integral part of ECGs recorded using wearable electronics, specifically during field monitoring, outside the controlled environment of a medical doctor’s office, or laboratory. The frequency spectrum of several types of interfering signals overlaps significantly with the ECG signal, making effective filtration impossible without losing clinically relevant information. In this article, we proceed from the practical assumption that it is unnecessary to analyze the entire ECG recording in real long-term recordings. Conversely, in the preprocessing phase, it is necessary to detect unreadable segments of the ECG signal. This paper proposes a novel method for automatically detecting unreadable segments distorted by superimposed interference in ECG recordings. The method is based on a convolutional neural network (CNN) and is comparable in quality to annotation performed by a medical expert, but incomparably faster. In a series of controlled experiments, the ECG signal was recorded during physical activities of varying intensities, and individual segments of the recordings were manually annotated based on visual assessment by a medical expert, i.e., divided into four different classes based on the intensity of distortion to the useful ECG signal. A deep convolutional model was designed and evaluated, exhibiting a 87.62% accuracy score and the same F1-score in automatic recognition of segments distorted by superimposed interference. Furthermore, the model exhibits an accuracy and F1-score of 98.70% in correctly identifying segments with visually detectable and non-detectable heart rate. The proposed interference detection procedure appears to be sufficiently effective despite its simplicity. It facilitates subsequent automatic analysis of undisturbed ECG waveform segments, which is crucial in ECG monitoring using wearable electronics.
- Open Access
- 6 September 2025
- Published by MDPI AG in Technologies
- Vol. 13 (9) , 407
User Evaluation of Head-Level Obstacle Detector for Visually Impaired
The white cane is a reliable and often-used assistive aid; however, it does not protect against obstacles at the head level. We designed and built an ultrasonic-based obstacle detector with a limited detection field in front of the head. The detector is located on the chest and can be mounted on backpack straps or around the neck. We have performed testing with 74 blind people and their instructors. Blind people used the device for three to four weeks in their regular lives, and instructors tested it by themselves or with their clients. The testing showed that individualization by the type of mounting is helpful. The needed detection distance depends on the situation and the speed of movement. In total, 70% of the users were satisfied with the distance options 80 cm, 110 cm, and 140 cm. 81% of the testers were satisfied, or somewhat satisfied, with the sliding switches to control. It is simple, and its position (setting) can be detected by touch. The testers see the benefit of using the device, especially in unknown environments (outdoor and indoor), primarily because of the increased safety by movement (64%) or the feeling of security (41%).
- 6 September 2025
- Published by MDPI AG in Technologies
- Vol. 13 (9) , 407
Open AccessUser Evaluation of Head-Level Obstacle Detector for Visually Impaired
The white cane is a reliable and often-used assistive aid; however, it does not protect against obstacles at the head level. We designed and built an ultrasonic-based obstacle detector with a limited detection field in front of the head. The detector is located on the chest and can be mounted on backpack straps or around the neck. We have performed testing with 74 blind people and their instructors. Blind people used the device for three to four weeks in their regular lives, and instructors tested it by themselves or with their clients. The testing showed that individualization by the type of mounting is helpful. The needed detection distance depends on the situation and the speed of movement. In total, 70% of the users were satisfied with the distance options 80 cm, 110 cm, and 140 cm. 81% of the testers were satisfied, or somewhat satisfied, with the sliding switches to control. It is simple, and its position (setting) can be detected by touch. The testers see the benefit of using the device, especially in unknown environments (outdoor and indoor), primarily because of the increased safety by movement (64%) or the feeling of security (41%).
- Open Access
Accuracy Improvement of Energy Expenditure Estimation Through Neural Networks: A Pilot Study
The estimation of energy expenditure (EE) is often an integral part of algorithms for wearable electronics. In field practice, procedures based on an indirect estimation of EE from the heart rate (using empirically or statistically based relationships) work correctly only in a narrow range of physical loads, yet they are current considered state of the art. This pilot study aims to experimentally assess novel method using a wide range of input sensors and parameters (heart rate, RR intervals, and 3D motion activity in several places on the body) and neural network (NN) algorithms. Our proposed method consists of training an NN on a specific subject, with a specific set and placement of sensors during the so-called training run, using the golden standard method of indirect calorimetry as a reference. Then, the subject’s EE can be estimated using trained NN. The results of the experiments (carried out on a total of 12 subjects during various physical activities) show a statistically significant improvement in EE estimation with the new prospective method, and it outperforms the state-of-the-art method based on the heart rate and regression model.
Open AccessAccuracy Improvement of Energy Expenditure Estimation Through Neural Networks: A Pilot Study
The estimation of energy expenditure (EE) is often an integral part of algorithms for wearable electronics. In field practice, procedures based on an indirect estimation of EE from the heart rate (using empirically or statistically based relationships) work correctly only in a narrow range of physical loads, yet they are current considered state of the art. This pilot study aims to experimentally assess novel method using a wide range of input sensors and parameters (heart rate, RR intervals, and 3D motion activity in several places on the body) and neural network (NN) algorithms. Our proposed method consists of training an NN on a specific subject, with a specific set and placement of sensors during the so-called training run, using the golden standard method of indirect calorimetry as a reference. Then, the subject’s EE can be estimated using trained NN. The results of the experiments (carried out on a total of 12 subjects during various physical activities) show a statistically significant improvement in EE estimation with the new prospective method, and it outperforms the state-of-the-art method based on the heart rate and regression model.
- 5 November 2023
- Published by SAE International in SAE International Journal of Advances and Current Practices in Mobility
- Vol. 1
Brake Control Allocation Employing Vehicle Motion Feedback for Four-Wheel-Independent-Drive Vehicle
This paper uses the brake control allocation method for Electric Vehicles (EVs) based on system-level vehicle Reference Point (RP) motion feedback. The RP motion control is an alternative to the standard brake torque allocation methods and results in improved vehicle stability in both longitudinal and lateral directions without requiring additional measurements beyond what is available in EVs with ABS and ESP. The proposed control law simplifies the brake torque allocation algorithm, reduces overall development time and effort, and merges most of the braking systems into one. Additionally, the measured or estimated signals required are reduced compared to the standard approach. The system-level RP measurements and references are transformed into individual wheel coordinate systems, where tracking is ensured by actuating both friction torques and electric motor regenerative torques using a proposed brake torque blending mechanism. The whole control system is validated in simulations using the Simulink vehicle dynamic simulator and IPG Carmaker high-fidelity simulator, utilizing the CTU FEE EFORCE formula model. Finally, a brake HiL stand validation is presented.
- 5 November 2023
- Published by SAE International in SAE International Journal of Advances and Current Practices in Mobility
- Vol. 1
Brake Control Allocation Employing Vehicle Motion Feedback for Four-Wheel-Independent-Drive Vehicle
This paper uses the brake control allocation method for Electric Vehicles (EVs) based on system-level vehicle Reference Point (RP) motion feedback. The RP motion control is an alternative to the standard brake torque allocation methods and results in improved vehicle stability in both longitudinal and lateral directions without requiring additional measurements beyond what is available in EVs with ABS and ESP. The proposed control law simplifies the brake torque allocation algorithm, reduces overall development time and effort, and merges most of the braking systems into one. Additionally, the measured or estimated signals required are reduced compared to the standard approach. The system-level RP measurements and references are transformed into individual wheel coordinate systems, where tracking is ensured by actuating both friction torques and electric motor regenerative torques using a proposed brake torque blending mechanism. The whole control system is validated in simulations using the Simulink vehicle dynamic simulator and IPG Carmaker high-fidelity simulator, utilizing the CTU FEE EFORCE formula model. Finally, a brake HiL stand validation is presented.
- Open Access
- 7 June 2023
- Published by Springer Nature in BMC Cardiovascular Disorders
- Vol. 23 (1) , 1-9
Prediction of post-operative atrial fibrillation in patients after cardiac surgery using heart rate variability
Purpose: Post-operative atrial fibrillation (PoAF) occurs in ~ 30% of patients after cardiac surgery. The etiology of PoAF is complex, but a disbalance in autonomic systems plays an important role. The goal of this study was to assess whether pre-operative heart rate variability analysis can predict the risk of PoAF. Methods: Patients without a history of AF with an indication for cardiac surgery were included. Two-hour ECG recordings one day before surgery was used for the HRV analysis. Univariate and multivariate logistic regression, including all HRV parameters, their combination, and clinical variables, were calculated to find the best predictive model for post-operative AF. Results: One hundred and thirty-seven patients (33 women) were enrolled in the study. PoAF occurred in 48 patients (35%, AF group); the remaining 89 patients were in the NoAF group. AF patients were significantly older (69.1 ± 8.6 vs. 63.4 ± 10.5 yrs., p = 0.002), and had higher CHA2DS2-VASc score (3 ± 1.4 vs. 2.5 ± 1.3, p = 0.01). In the multivariate regression model, parameters independently associated with higher risk of AF were pNN50, TINN, absolute power VLF, LF and HF, total power, SD2, and the Porta index. A combination of clinical variables with HRV parameters in the ROC analysis achieved an AUC of 0.86, a sensitivity of 0.95, and a specificity of 0.57 and was more effective in PoAF prediction than a combination of clinical variables alone. Conclusion: A combination of several HRV parameters is helpful in predicting the risk of PoAF. Attenuation of heart rate variability increases the risk for PoAF.
- 7 June 2023
- Published by Springer Nature in BMC Cardiovascular Disorders
- Vol. 23 (1) , 1-9
Open AccessPrediction of post-operative atrial fibrillation in patients after cardiac surgery using heart rate variability
Purpose: Post-operative atrial fibrillation (PoAF) occurs in ~ 30% of patients after cardiac surgery. The etiology of PoAF is complex, but a disbalance in autonomic systems plays an important role. The goal of this study was to assess whether pre-operative heart rate variability analysis can predict the risk of PoAF. Methods: Patients without a history of AF with an indication for cardiac surgery were included. Two-hour ECG recordings one day before surgery was used for the HRV analysis. Univariate and multivariate logistic regression, including all HRV parameters, their combination, and clinical variables, were calculated to find the best predictive model for post-operative AF. Results: One hundred and thirty-seven patients (33 women) were enrolled in the study. PoAF occurred in 48 patients (35%, AF group); the remaining 89 patients were in the NoAF group. AF patients were significantly older (69.1 ± 8.6 vs. 63.4 ± 10.5 yrs., p = 0.002), and had higher CHA2DS2-VASc score (3 ± 1.4 vs. 2.5 ± 1.3, p = 0.01). In the multivariate regression model, parameters independently associated with higher risk of AF were pNN50, TINN, absolute power VLF, LF and HF, total power, SD2, and the Porta index. A combination of clinical variables with HRV parameters in the ROC analysis achieved an AUC of 0.86, a sensitivity of 0.95, and a specificity of 0.57 and was more effective in PoAF prediction than a combination of clinical variables alone. Conclusion: A combination of several HRV parameters is helpful in predicting the risk of PoAF. Attenuation of heart rate variability increases the risk for PoAF.
- Open Access
- 8 April 2022
- Published by MDPI AG in Electronics
- Vol. 11 (8) , 1179
System for Game-like Therapy in Balance Issues Using Audiovisual Feedback and Force Platform
Background: The aim of the work is to verify the usability of a stabilometric platform and audiovisual feedback in the group-based therapy of patients with vertebral algic syndrome, to analyze an immediate effect after a single therapeutic unit, and to analyze differences between male and female probands. Methods: The study included 189 patients (90 male, age 55 ± 12 and 89 female, age 52 ± 12). All patients received group balance therapy with a portable medical device, Homebalance MA. The intervention consisted of measurement of quiet stance and a reference training scene before and after 15 min of game-like balance training with audiovisual feedback. Results: A statistically significantly lower value of the body sway trajectory during quiet stance was detected in men than in women. After a single therapy session, there was a statistically significant improvement in quiet stance with visual feedback, and marginal statistically significant improvement in the time required to complete the reference training scene. Conclusions: Homebalance MA is a utilizable tool for group therapy. The use of group game-like balance training increases the availability of physiotherapeutic intervention for a larger number of patients, while maintaining the positive effect of the therapy.
- 8 April 2022
- Published by MDPI AG in Electronics
- Vol. 11 (8) , 1179
Open AccessSystem for Game-like Therapy in Balance Issues Using Audiovisual Feedback and Force Platform
Background: The aim of the work is to verify the usability of a stabilometric platform and audiovisual feedback in the group-based therapy of patients with vertebral algic syndrome, to analyze an immediate effect after a single therapeutic unit, and to analyze differences between male and female probands. Methods: The study included 189 patients (90 male, age 55 ± 12 and 89 female, age 52 ± 12). All patients received group balance therapy with a portable medical device, Homebalance MA. The intervention consisted of measurement of quiet stance and a reference training scene before and after 15 min of game-like balance training with audiovisual feedback. Results: A statistically significantly lower value of the body sway trajectory during quiet stance was detected in men than in women. After a single therapy session, there was a statistically significant improvement in quiet stance with visual feedback, and marginal statistically significant improvement in the time required to complete the reference training scene. Conclusions: Homebalance MA is a utilizable tool for group therapy. The use of group game-like balance training increases the availability of physiotherapeutic intervention for a larger number of patients, while maintaining the positive effect of the therapy.
- Open Access
- 1 April 2022
- Published by MDPI AG in Electronics
- Vol. 11 (7) , 1121
Linear, High Dynamic Range Isolated Skin Resistance Transducer Circuit for Neurophysiological Research in Individuals after Spinal Cord Injury
The quantification of skin resistance in individuals after spinal cord injury for the purpose of neurophysiological research is difficult, mainly as a consequence of decreased activity of sweat glands in the injured human organism. In this original work, we propose a custom electrical skin resistance transducer, featuring extremely low patient auxiliary current, linear response and high dynamic range. After the design and fabrication of the prototype device, we conducted preliminary benchmark tests. We found that our prototype transducer was able to linearly report a broad range of resistance presented to its input terminals, which is not usually found in skin resistance research instrumentation. The basic design idea is viable and, following further research, an improved version of presented prototype device may be used for the purpose of neurophysiological research in individuals after spinal cord injury.
- 1 April 2022
- Published by MDPI AG in Electronics
- Vol. 11 (7) , 1121
Open AccessLinear, High Dynamic Range Isolated Skin Resistance Transducer Circuit for Neurophysiological Research in Individuals after Spinal Cord Injury
The quantification of skin resistance in individuals after spinal cord injury for the purpose of neurophysiological research is difficult, mainly as a consequence of decreased activity of sweat glands in the injured human organism. In this original work, we propose a custom electrical skin resistance transducer, featuring extremely low patient auxiliary current, linear response and high dynamic range. After the design and fabrication of the prototype device, we conducted preliminary benchmark tests. We found that our prototype transducer was able to linearly report a broad range of resistance presented to its input terminals, which is not usually found in skin resistance research instrumentation. The basic design idea is viable and, following further research, an improved version of presented prototype device may be used for the purpose of neurophysiological research in individuals after spinal cord injury.
- Open Access
- 30 March 2022
- Published by MDPI AG in Electronics
- Vol. 11 (7) , 1096
Measuring of the Energy Expenditure during Balance Training Using Wearable Electronics
Homebalance Stability medical device, based on audio-visual feedback and Nintendo Wii Balance Board, is a suitable tool for telerehabilitation of balance issues in patients with brain damage. The main goal was to expand the system by energy expenditure measurements and to verify the usability of the telemetric mobile device FlexiGuard. We used the FlexiGuard system (developed at our institute) and Oxycon (JAEGER® Oxycon Mobile, Germany) to measure the energy expenditure. We performed measurements on eight probands. Each proband underwent six activities for a total length of 90 min. During these activities, we measured energy expenditure using Oxycon and heart rate using the FlexiGuard system, from which we calculated the energy expenditure. By comparing the energy expenditure from measuring the heart rate with the FlexiGuard system with that from the Oxycon reference device, we verified the applicability of the FlexiGuard system for estimation energy expenditure. The average deviation from the reference instrument was under 30%. The conventional method, such as Oxycon, cannot be used during home therapy. Therefore, we upgraded the platform of our telemetry system (FlexiGuard), which can measure the heart rate and calculate the energy expenditure.
- 30 March 2022
- Published by MDPI AG in Electronics
- Vol. 11 (7) , 1096
Open AccessMeasuring of the Energy Expenditure during Balance Training Using Wearable Electronics
Homebalance Stability medical device, based on audio-visual feedback and Nintendo Wii Balance Board, is a suitable tool for telerehabilitation of balance issues in patients with brain damage. The main goal was to expand the system by energy expenditure measurements and to verify the usability of the telemetric mobile device FlexiGuard. We used the FlexiGuard system (developed at our institute) and Oxycon (JAEGER® Oxycon Mobile, Germany) to measure the energy expenditure. We performed measurements on eight probands. Each proband underwent six activities for a total length of 90 min. During these activities, we measured energy expenditure using Oxycon and heart rate using the FlexiGuard system, from which we calculated the energy expenditure. By comparing the energy expenditure from measuring the heart rate with the FlexiGuard system with that from the Oxycon reference device, we verified the applicability of the FlexiGuard system for estimation energy expenditure. The average deviation from the reference instrument was under 30%. The conventional method, such as Oxycon, cannot be used during home therapy. Therefore, we upgraded the platform of our telemetry system (FlexiGuard), which can measure the heart rate and calculate the energy expenditure.
- Open Access
- 24 November 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (23) , 11150
Gearbox Mechanical Efficiency Determination by Strain Gauges Direct Application
This article describes a unique method of measuring the efficiency of gearboxes using foil strain gauges, which allows maintaining the current configuration of the gearbox within the overall assembly of the machine and its functional condition. The presented method is applicable to gearboxes located in the original equipment assembly without the need to use a test rig. Using foil strain gauges, the torque at the input and output of the gearbox is detected. Therefore, the accuracy of torque measurement is key. The crucial step is the calibration of the instrumentation to the given application conditions, which, in this case, is ensured by a virtual calibration using a very accurate FEM analysis. The accuracy of the position of strain gauges and virtual calibration of measurements generate inaccuracies affecting the resulting uncertainty of the determined efficiency. The present article shows, on the example of several measurements, that when using 24-bit converters, after processing the obtained data, mechanical stress with a sensitivity better than hundredths of an MPa can be reliably detected even without signal amplification from strain gauges. It follows that the efficiency is determined with an accuracy of better than low units of tenths.
- 24 November 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (23) , 11150
Open AccessGearbox Mechanical Efficiency Determination by Strain Gauges Direct Application
This article describes a unique method of measuring the efficiency of gearboxes using foil strain gauges, which allows maintaining the current configuration of the gearbox within the overall assembly of the machine and its functional condition. The presented method is applicable to gearboxes located in the original equipment assembly without the need to use a test rig. Using foil strain gauges, the torque at the input and output of the gearbox is detected. Therefore, the accuracy of torque measurement is key. The crucial step is the calibration of the instrumentation to the given application conditions, which, in this case, is ensured by a virtual calibration using a very accurate FEM analysis. The accuracy of the position of strain gauges and virtual calibration of measurements generate inaccuracies affecting the resulting uncertainty of the determined efficiency. The present article shows, on the example of several measurements, that when using 24-bit converters, after processing the obtained data, mechanical stress with a sensitivity better than hundredths of an MPa can be reliably detected even without signal amplification from strain gauges. It follows that the efficiency is determined with an accuracy of better than low units of tenths.