EDEliomar R. Conde Duque

Eliomar R. Conde Duque

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Eliomar R. Conde Duque has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Improvement of Robustness of MPC Adding Repetitive Behavior for the DFIG Current Control

    by Eliomar R. Conde Duque, Angelo Lunardi, Juan S. Solís-Chaves, Tiago dos S. Paiva, Darlan A. Fernandes, Alfeu J. Sguarezi Filho

    This paper shows an increase in the robustness of a DFIG-based wind energy system when a predictive-repetitive controller in the dq reference frame is used for the control of the rotor current. This designing approach proposes a model predictive control with a receding horizon technique that uses the frequency decomposition of the reference signal as a filter. Furthermore, an augmented space-state model from the original plant model is obtained, and its implementation is addressed from the perspective of normal operating conditions of DFIG in wind energy systems. Additionally, this repetitive controller increases the robustness of the predictive control when a mismatch in machine parameters is considered. Experimental results presented in this paper endorse the advantages of this controller.


  • A Predictive Repetitive Current Control in Stationary Reference Frame for DFIG Systems Under Distorted Voltage Operation

    by Eliomar R. Conde D., Angelo Lunardi, Luis Felipe Normandia Lourenco, Alfeu J. Sguarezi Filho

    This article presents a stationary reference frame implementation of the predictive repetitive controller under ideal and nonideal stator voltage conditions. Thanks to the combination of the model predictive control (MPC) and the repetitive control techniques, the predictive repetitive control uses the capabilities of both techniques to achieve the control objectives without the need of using a PLL for the stator flux in ideal conditions as the approach is developed in the stationary reference frame $\alpha \beta $ . For the operation of the technique, it is also not necessary to know the harmonic content of the nonideal stator voltage beforehand, but, for this case, and given the nature of the distortions, the use of the PLL is necessary to estimate the phase angle and the magnitude of the voltage’s fundamental component. This means a great advantage over previous techniques due to the fact that special considerations are not needed over the mathematical model of the doubly fed induction generator (DFIG). Experimental results of the proposed technique are presented in ideal and nonideal grid conditions, and under variable rotor speed. Moreover, a comparison with the classic MPC technique is presented.


  • Open Access

    Robust Predictive Control with Three-Vector Modulation Connected to the Power Grid

    by Angelo Lunardi, Eliomar R. Conde D., Renato M. Monaro, Darlan A. Fernandes, Alfeu J. Sguarezi Filho

    Robust predictive control is presented in this article using a three-vector modulation for a grid-connected three-phase inverter. The aims of this article are proposing a robust controller that is able to deal with some variations of parameters that occur in practical systems and demonstrating the performance of the controller with experimental tests that change the inductance and consequently the parasitic resistance of the plant; the same controller can predictive the changes to obtain the optimal performance. The article also presents mathematical modeling for plants and controllers and a modulation method to solve the variable frequency problem. Experimental tests corroborate the expected results and validate the controller’s efficiency according to the control system analysis requirements and the IEEE 1547.2-2008 standard.


  • Implementation of DFIG MPC-WM and three-phase power CCG MPRC-WM using Simulink/MATLAB®

    by Alfeu J. Sguarezi Filho, Angelo S. Lunardi, Eliomar R. Conde D.


  • Open Access

    Model Predictive Control with Modulator Applied to Grid Inverter under Voltage Distorted

    by Angelo Lunardi, Eliomar R. Conde D, Jefferson de Assis, Darlan A. Fernandes, Alfeu J. Sguarezi Filho

    This research paper presents a model of predictive control with a modulator for the inverter linked to the electrical grid, using the stationary reference frame and operating under grid distorted voltage. The stationary reference frame model for the system is obtained in its fundamental frequency and then the model predictive technique is implemented, which predicts the system actions using the obtained system model without the need of any other harmonic consideration. The controller calculates the voltage vector of the inverter through the minimization of the cost function. Thus, the proposal demonstrates, through experiments, its positive results regarding the low impact of the distorted voltage in the grid current without using any harmonic consideration on the model. Experimental results and comparisons carried out endorse the proposal of this work.


  • Current Control for DFIG Systems Under Distorted Voltage Using Predictive–Repetitive Control

    by Eliomar R. Conde D., Angelo Lunardi, Alfeu J. Sguarezi Filho

    This article presents a predictive–repetitive control for rotor current control operating under voltage harmonic distortion for a doubly fed induction generator in a synchronous reference frame. Predictive–repetitive control is an approach that uses receding horizon by predictive control with frequency decomposition of the reference signal. Moreover, to apply in wind energy, the predictive–repetitive control is implemented and designed from the perspectives of the power system. This controller is designed by using the state-space model of the plant, and the experimental results with voltage harmonic distortions are presented to prove the proposal.


  • Open Access

    Power System Stability with Power-Electronic Converter Interfaced Renewable Power Generation: Present Issues and Future Trends

    by Lasantha Meegahapola, Alfeu Sguarezi, Jack Stanley Bryant, Mingchen Gu, Eliomar R. Conde D., Rafael B. A. Cunha

    The energy sector is currently undergoing a rapid transformation with the integration of power electronic converter (PEC)-interfaced renewable energy sources (RES), such as wind and solar photovoltaic (PV) systems, at both the transmission and distribution networks. Power system stability has been significantly influenced by this power grid transformation. This paper comprehensively reviews major power system stability issues affected due to large-scale integration of PEC-interfaced RES in power grids, with some example case studies relevant for each stability category. According to the review, stability issues are mainly originating from reduction in synchronous inertia, reduction in reactive power reserve, low short-circuit strength of the power network, and fault ride-through (FRT) strategy/capability of the PEC-interfaced RES. Decrease in synchronous inertia could affect both the rotor angle stability and the frequency stability, while decrease in short-circuit strength and reactive power reserve could cause voltage stability and rotor angle stability issues in power networks. Sub-synchronous control interactions are also receiving a lot of attention by the power industry due to increasing oscillatory stability incidents reported in power networks with PEC-interfaced RES. FRT capabilities/strategies of PEC-interfaced RES are also playing a pivotal role in power grid stability due to its influence on active and reactive power, hence more emphasis should be placed on FRT schemes of PEC-interfaced RES, since future power grids are expected to operate with 100% PEC-interfaced generation sources. Stability improvement strategies could be implemented to address multiple stability issues in PEC-interfaced power networks; however, rigorous stability studies are required to identify the optimal conditions to implement these improvement strategies. Furthermore, ongoing structural changes in power grids to accommodate remotely sited PEC-interfaced RES are also influencing the stability of power grids. Therefore, all these factors must be carefully considered by system operators when planning and operating power grids in a secure and stable manner with high penetration levels of PEC-interfaced RES.