Xiao Cheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Xiao Cheng has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Shaolong Kuang
Mechanical and Electrical Engineering, Soochow University, Suzhou, China
5 shared publications - Wei Kou
Mechanical and Electrical Engineering, Soochow University, Suzhou, China
3 shared publications - Baosen Tan
Key Laboratory for Biomechanics and Mechanobiology of Chinese Education Ministry, Beijing Advanced Innovation Centre for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing 100083, People's Republic of China
1 shared publication Changwan Zheng
Jiangsu Provincial Key Laboratory of Advanced Robotics, Soochow University, Suzhou, China
1 shared publicationDongya Li
Applied Technology College, Soochow University, SuZhou, China
1 shared publication- Feng Zhou
Department of Orthopaedic Surgery, The First Affiliated Hospital of Soochow University, Orthopedic Institute, Suzhou Medical College, Soochow University, Suzhou, Jiangsu, 215000, PR China
1 shared publication
Latest Publications
- 29 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automation Science and Engineering
- Vol. 22 (15455955) , 21936-21947
Design and Experimental Evaluation of a Novel Robot-Assisted Surgical System for Pelvic Fracture Closed Reduction
This paper designs a novel clinical-oriented robot-assisted surgical system (RASS) for pelvic fracture closed reduction, including three core parts: preoperative planning system, intraoperative navigation system and reduction robot. In preoperative planning system, a virtual reduction method based on the Statistical Shape Model (SSM) and pelvic partial surface data is adopted, providing personalized and detailed preoperative plans with high-efficiency and enhanced adaptability. Then, a serial-parallel hybrid reduction robot with robot autonomous and master-slave reduction mode switching control strategy is designed, combined with the intuitive and real-time guidance of the intraoperative navigation system, achieving flexible and precise reduction operations. Additionally, clinical solution research based on the designed RASS is developed and evaluated by ten pelvic models and five animal experiments. In the pelvic model experiments, the root mean square error (RMSE) of the distance between the reduced and intact pelvic point cloud is 1.0mm, and the three points error of 10 cases are all within 2.0mm, achieving an excellent reduction effect. In the animal experiments, the four point-pairs distance decreases from 26.7±1.04mm to 5.86±0.82mm, and the mean distance between the two point clouds of the "Pig-081" before modeling and after reduction is 2.81mm, which further confirmed the effectiveness of the system, as well as the feasibility and safety of the clinical solution. The designed novel RASS provides a promising solution in the treatment of pelvic fractures, and the experimental results lay the foundation for further clinical application.
- 29 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automation Science and Engineering
- Vol. 22 (15455955) , 21936-21947
Design and Experimental Evaluation of a Novel Robot-Assisted Surgical System for Pelvic Fracture Closed Reduction
This paper designs a novel clinical-oriented robot-assisted surgical system (RASS) for pelvic fracture closed reduction, including three core parts: preoperative planning system, intraoperative navigation system and reduction robot. In preoperative planning system, a virtual reduction method based on the Statistical Shape Model (SSM) and pelvic partial surface data is adopted, providing personalized and detailed preoperative plans with high-efficiency and enhanced adaptability. Then, a serial-parallel hybrid reduction robot with robot autonomous and master-slave reduction mode switching control strategy is designed, combined with the intuitive and real-time guidance of the intraoperative navigation system, achieving flexible and precise reduction operations. Additionally, clinical solution research based on the designed RASS is developed and evaluated by ten pelvic models and five animal experiments. In the pelvic model experiments, the root mean square error (RMSE) of the distance between the reduced and intact pelvic point cloud is 1.0mm, and the three points error of 10 cases are all within 2.0mm, achieving an excellent reduction effect. In the animal experiments, the four point-pairs distance decreases from 26.7±1.04mm to 5.86±0.82mm, and the mean distance between the two point clouds of the "Pig-081" before modeling and after reduction is 2.81mm, which further confirmed the effectiveness of the system, as well as the feasibility and safety of the clinical solution. The designed novel RASS provides a promising solution in the treatment of pelvic fractures, and the experimental results lay the foundation for further clinical application.
- Open Access
- 19 January 2024
- Published by Association for Computing Machinery (ACM)
- p. 334-339
An Improved ICP Registration Method for Closed Reduction Navigation of Pelvic Fracture
Image registration is an important technology for closed reduction surgery navigation for pelvic fractures, which can visualize and track the surgical process by registering the patient's physical surgical site with the 3D (three dimensional) model. The most classical spatial image registration method is the point cloud registration method based on the ICP (Iterative Closest Point) algorithm, which has low accuracy and is susceptible to outliers. A Fast-Robust-ICP registration method is proposed for pelvic point cloud registration. Firstly, a robust error measure method with Welsch function is introduced based on the ICP registration process to improve the registration accuracy. Then, the Majorization-Minimization algorithm with Anderson acceleration function is used to improve the efficiency of the registration. Finally, the comparative experiment with six groups of point clouds included three groups of normal data sets and three groups of abnormal data sets is carried out. The experimental results show that the mean RMSE (Root Mean Square Error) of this method is much smaller than ICP, and the registered point cloud registration results are more reasonable. Compared with the ICP algorithm, the algorithm proposed in this paper achieves more accurate registration results within a reasonable time range and exhibits better robustness in handling abnormal situations.
- 19 January 2024
- Published by Association for Computing Machinery (ACM)
- p. 334-339
Open AccessAn Improved ICP Registration Method for Closed Reduction Navigation of Pelvic Fracture
Image registration is an important technology for closed reduction surgery navigation for pelvic fractures, which can visualize and track the surgical process by registering the patient's physical surgical site with the 3D (three dimensional) model. The most classical spatial image registration method is the point cloud registration method based on the ICP (Iterative Closest Point) algorithm, which has low accuracy and is susceptible to outliers. A Fast-Robust-ICP registration method is proposed for pelvic point cloud registration. Firstly, a robust error measure method with Welsch function is introduced based on the ICP registration process to improve the registration accuracy. Then, the Majorization-Minimization algorithm with Anderson acceleration function is used to improve the efficiency of the registration. Finally, the comparative experiment with six groups of point clouds included three groups of normal data sets and three groups of abnormal data sets is carried out. The experimental results show that the mean RMSE (Root Mean Square Error) of this method is much smaller than ICP, and the registered point cloud registration results are more reasonable. Compared with the ICP algorithm, the algorithm proposed in this paper achieves more accurate registration results within a reasonable time range and exhibits better robustness in handling abnormal situations.
- Open Access
- 20 October 2023
- Published by Elsevier in Biomimetic Intelligence and Robotics
- Vol. 3 (4)
Preoperative virtual reduction method for pelvic fractures based on statistical shape models and partial surface data
- 20 October 2023
- Published by Elsevier in Biomimetic Intelligence and Robotics
- Vol. 3 (4)
Open AccessPreoperative virtual reduction method for pelvic fractures based on statistical shape models and partial surface data
- Open Access
- 27 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 118-124
A Fuzzy Adaptive PID Control Method for Novel Designed Rail Grinding Equipment
Rail defects appear in a greater variety and frequency with the rapid development of High-Speed Rail (HSR), which seriously affects the safe operation of trains. Rail grinding is one of the common methods used to eliminate these defects. However, the quality of rail grinding is often limited by the constant power control method. This paper presents a fuzzy adaptive PID control method based on PID control. In this method, a fuzzy rule library of input and output is established according to the experience of experts and grinding operators, and the PID control parameters can be adjusted in real time through the library to achieve the purpose of constant power grinding. Compared with classic PID, the effectiveness of the proposed method was verified by simulation and the rail grinding experiment with the designed equipment. Results showed that the power data of fuzzy adaptive PID control had less fluctuation, which could be basically stabilized at 5KW±0.1KW, and the curve tracking error was reduced by 60.9%. It is concluded that this method can greatly improve the power accuracy and stability of rail grinding.
- 27 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 118-124
Open AccessA Fuzzy Adaptive PID Control Method for Novel Designed Rail Grinding Equipment
Rail defects appear in a greater variety and frequency with the rapid development of High-Speed Rail (HSR), which seriously affects the safe operation of trains. Rail grinding is one of the common methods used to eliminate these defects. However, the quality of rail grinding is often limited by the constant power control method. This paper presents a fuzzy adaptive PID control method based on PID control. In this method, a fuzzy rule library of input and output is established according to the experience of experts and grinding operators, and the PID control parameters can be adjusted in real time through the library to achieve the purpose of constant power grinding. Compared with classic PID, the effectiveness of the proposed method was verified by simulation and the rail grinding experiment with the designed equipment. Results showed that the power data of fuzzy adaptive PID control had less fluctuation, which could be basically stabilized at 5KW±0.1KW, and the curve tracking error was reduced by 60.9%. It is concluded that this method can greatly improve the power accuracy and stability of rail grinding.
- 13 August 2021
- Published by IOP Publishing in Biofabrication
- Vol. 13 (4) , 043001
Stereotactic technology for 3D bioprinting: from the perspective of robot mechanism
Three-dimensional (3D) bioprinting has been widely applied in the field of biomedical engineering because of its rapidly individualized fabrication and precisely geometric designability. The emerging demand for bioprinted tissues/organs with bio-inspired anisotropic property is stimulating new bioprinting strategies. Stereotactic bioprinting is regarded as a preferable strategy for this purpose, which can perform bioprinting at the target position from any desired orientation in 3D space. In this work, based on the motion characteristics analysis of the stacked bioprinting technologies, mechanism configurations and path planning methods for robotic stereotactic bioprinting were investigated and a prototype system based on the double parallelogram mechanism was introduced in detail. Moreover, the influence of the time dimension on stereotactic bioprinting was discussed. Finally, technical challenges and future trends of stereotactic bioprinting within the field of biomedical engineering were summarized.
- 13 August 2021
- Published by IOP Publishing in Biofabrication
- Vol. 13 (4) , 043001
Stereotactic technology for 3D bioprinting: from the perspective of robot mechanism
Three-dimensional (3D) bioprinting has been widely applied in the field of biomedical engineering because of its rapidly individualized fabrication and precisely geometric designability. The emerging demand for bioprinted tissues/organs with bio-inspired anisotropic property is stimulating new bioprinting strategies. Stereotactic bioprinting is regarded as a preferable strategy for this purpose, which can perform bioprinting at the target position from any desired orientation in 3D space. In this work, based on the motion characteristics analysis of the stacked bioprinting technologies, mechanism configurations and path planning methods for robotic stereotactic bioprinting were investigated and a prototype system based on the double parallelogram mechanism was introduced in detail. Moreover, the influence of the time dimension on stereotactic bioprinting was discussed. Finally, technical challenges and future trends of stereotactic bioprinting within the field of biomedical engineering were summarized.
- 1 January 1999
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automatic Control
- Vol. 44 (9) , 1791-1795
Degrees of controllability and observability for close modes of flexible space structures
Flexible structures usually possess vibration modes with close, but not exactly repeated, natural frequencies. Quantifying the controllability and observability of such modes is a nontrivial task; this contrasts with the case of modes that are either exactly repeated or widely separated. The paper derives expressions for the degrees of controllability and observability of near-repeated modes by examining the closed-form Grammians of flexible structures. The results obtained quantify the role of damping and frequency separation in controllability and observability.
- 1 January 1999
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automatic Control
- Vol. 44 (9) , 1791-1795
Degrees of controllability and observability for close modes of flexible space structures
Flexible structures usually possess vibration modes with close, but not exactly repeated, natural frequencies. Quantifying the controllability and observability of such modes is a nontrivial task; this contrasts with the case of modes that are either exactly repeated or widely separated. The paper derives expressions for the degrees of controllability and observability of near-repeated modes by examining the closed-form Grammians of flexible structures. The results obtained quantify the role of damping and frequency separation in controllability and observability.