Oleksii Ostras
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Oleksii Ostras has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Gianmarco F. Pinton
Joint Department of Biomedical Engineering, The University of North Carolina at Chapel Hill, Chapel Hill, NC, USA
2 shared publications - Danai Eleni Soulioti
Lampe Joint Department of Biomedical Engineering, The University of North Carolina at Chapel Hill, 116 Manning Drive, Chapel Hill, North Carolina, 27599, United States
1 shared publication - Dongwoon Hyun
Department of Radiology, Stanford University, Stanford, CA, USA
1 shared publication - Francisco Santibanez
The Lampe Joint Department of Biomedical Engineering at UNC Chapel-Hill, Chapel-Hill and NC State University, Raleigh, NC, USA
1 shared publication Gianmarco Pinton
Joint Department of Biomedical Engineering of the University of North Carolina at Chapel Hill and North Carolina State University , Chapel Hill, North Carolina 27514, USA
1 shared publication- Ihor S. Shponka
Dnipro State Medical University, Volodymyra Vernadskoho str., 9, Dnipro, 49044
1 shared publication
Latest Publications
- 5 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics
- Vol. 73 (1) , 24-34
Labeled Numerical Phantom of Abdominal Wall for Wave-Physics-Based Ultrasound Imaging: Applications to Image Reconstruction
Transabdominal ultrasound imaging requires acoustic wave propagation through the abdominal wall, which consists of a complex organization of tissue layers that degrade imaging of underlying organs such as the liver. A priori knowledge of the acoustic properties of this medium could enable adaptive imaging techniques, but the underlying ground truth properties in a living patient is a fundamentally unknown quantity. Numerical simulations can offer a solution to this challenge by modeling the propagation of ultrasound imaging pulses in media with known acoustic properties and can therefore provide a quantitative relationship between the received ultrasound echoes and the underlying tissue structure. However, to be comparable with clinical scenarios, in silico phantoms of the abdominal wall must be geometrically and quantitatively accurate, with rigorous tolerances. Here, we describe a dataset generation approach to produce experimentally calibrated ultrasound data for transabdominal imaging. Semantically labeled 3D in silico phantoms with 0.33mm isotropic resolution, along with physical parameters from the literature of the human abdominal wall, are used to model acoustic propagation through human tissue. We perform 2D numerical simulations of the Westervelt equation to generate a dataset of raw ultrasound data for liver imaging consisting of 1027 samples. We then discuss the applications of this dataset for facilitating abdominal ultrasound imaging research. The labeled abdominal dataset, simulated data, and the simulation tools that model wave propagation are made publicly available.
- 5 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics
- Vol. 73 (1) , 24-34
Labeled Numerical Phantom of Abdominal Wall for Wave-Physics-Based Ultrasound Imaging: Applications to Image Reconstruction
Transabdominal ultrasound imaging requires acoustic wave propagation through the abdominal wall, which consists of a complex organization of tissue layers that degrade imaging of underlying organs such as the liver. A priori knowledge of the acoustic properties of this medium could enable adaptive imaging techniques, but the underlying ground truth properties in a living patient is a fundamentally unknown quantity. Numerical simulations can offer a solution to this challenge by modeling the propagation of ultrasound imaging pulses in media with known acoustic properties and can therefore provide a quantitative relationship between the received ultrasound echoes and the underlying tissue structure. However, to be comparable with clinical scenarios, in silico phantoms of the abdominal wall must be geometrically and quantitatively accurate, with rigorous tolerances. Here, we describe a dataset generation approach to produce experimentally calibrated ultrasound data for transabdominal imaging. Semantically labeled 3D in silico phantoms with 0.33mm isotropic resolution, along with physical parameters from the literature of the human abdominal wall, are used to model acoustic propagation through human tissue. We perform 2D numerical simulations of the Westervelt equation to generate a dataset of raw ultrasound data for liver imaging consisting of 1027 samples. We then discuss the applications of this dataset for facilitating abdominal ultrasound imaging research. The labeled abdominal dataset, simulated data, and the simulation tools that model wave propagation are made publicly available.
- 1 October 2023
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 154 (4) , 2410-2425
Ultrasound imaging of lung disease and its relationship to histopathology: An experimentally validated simulation approach
Lung ultrasound (LUS) is a widely used technique in clinical lung assessment, yet the relationship between LUS images and the underlying disease remains poorly understood due in part to the complexity of the wave propagation physics in complex tissue/air structures. Establishing a clear link between visual patterns in ultrasound images and underlying lung anatomy could improve the diagnostic accuracy and clinical deployment of LUS. Reverberation that occurs at the lung interface is complex, resulting in images that require interpretation of the artifacts deep in the lungs. These images are not accurate spatial representations of the anatomy due to the almost total reflectivity and high impedance mismatch between aerated lung and chest wall. Here, we develop an approach based on the first principles of wave propagation physics in highly realistic maps of the human chest wall and lung to unveil a relationship between lung disease, tissue structure, and its resulting effects on ultrasound images. It is shown that Fullwave numerical simulations of ultrasound propagation and histology-derived acoustical maps model the multiple scattering physics at the lung interface and reproduce LUS B-mode images that are comparable to clinical images. However, unlike clinical imaging, the underlying tissue structure model is known and controllable. The amount of fluid and connective tissue components in the lung were gradually modified to model disease progression, and the resulting changes in B-mode images and non-imaging reverberation measures were analyzed to explain the relationship between pathological modifications of lung tissue and observed LUS.
- 1 October 2023
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 154 (4) , 2410-2425
Ultrasound imaging of lung disease and its relationship to histopathology: An experimentally validated simulation approach
Lung ultrasound (LUS) is a widely used technique in clinical lung assessment, yet the relationship between LUS images and the underlying disease remains poorly understood due in part to the complexity of the wave propagation physics in complex tissue/air structures. Establishing a clear link between visual patterns in ultrasound images and underlying lung anatomy could improve the diagnostic accuracy and clinical deployment of LUS. Reverberation that occurs at the lung interface is complex, resulting in images that require interpretation of the artifacts deep in the lungs. These images are not accurate spatial representations of the anatomy due to the almost total reflectivity and high impedance mismatch between aerated lung and chest wall. Here, we develop an approach based on the first principles of wave propagation physics in highly realistic maps of the human chest wall and lung to unveil a relationship between lung disease, tissue structure, and its resulting effects on ultrasound images. It is shown that Fullwave numerical simulations of ultrasound propagation and histology-derived acoustical maps model the multiple scattering physics at the lung interface and reproduce LUS B-mode images that are comparable to clinical images. However, unlike clinical imaging, the underlying tissue structure model is known and controllable. The amount of fluid and connective tissue components in the lung were gradually modified to model disease progression, and the resulting changes in B-mode images and non-imaging reverberation measures were analyzed to explain the relationship between pathological modifications of lung tissue and observed LUS.
- 1 November 2021
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 150 (5) , 3904-3913
Diagnostic ultrasound imaging of the lung: A simulation approach based on propagation and reverberation in the human body
Although ultrasound cannot penetrate a tissue/air interface, it images the lung with high diagnostic accuracy. Lung ultrasound imaging relies on the interpretation of “artifacts,” which arise from the complex reverberation physics occurring at the lung surface but appear deep inside the lung. This physics is more complex and less understood than conventional B-mode imaging in which the signal directly reflected by the target is used to generate an image. Here, to establish a more direct relationship between the underlying acoustics and lung imaging, simulations are used. The simulations model ultrasound propagation and reverberation in the human abdomen and at the tissue/air interfaces of the lung in a way that allows for direct measurements of acoustic pressure inside the human body and various anatomical structures, something that is not feasible clinically or experimentally. It is shown that the B-mode images beamformed from these acoustical simulations reproduce primary clinical features that are used in diagnostic lung imaging, i.e., A-lines and B-lines, with a clear relationship to known underlying anatomical structures. Both the oblique and parasagittal views are successfully modeled with the latter producing the characteristic “bat sign,” arising from the ribs and intercostal part of the pleura. These simulations also establish a quantitative link between the percentage of fluid in exudative regions and the appearance of B-lines, suggesting that the B-mode may be used as a quantitative imaging modality.
- 1 November 2021
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 150 (5) , 3904-3913
Diagnostic ultrasound imaging of the lung: A simulation approach based on propagation and reverberation in the human body
Although ultrasound cannot penetrate a tissue/air interface, it images the lung with high diagnostic accuracy. Lung ultrasound imaging relies on the interpretation of “artifacts,” which arise from the complex reverberation physics occurring at the lung surface but appear deep inside the lung. This physics is more complex and less understood than conventional B-mode imaging in which the signal directly reflected by the target is used to generate an image. Here, to establish a more direct relationship between the underlying acoustics and lung imaging, simulations are used. The simulations model ultrasound propagation and reverberation in the human abdomen and at the tissue/air interfaces of the lung in a way that allows for direct measurements of acoustic pressure inside the human body and various anatomical structures, something that is not feasible clinically or experimentally. It is shown that the B-mode images beamformed from these acoustical simulations reproduce primary clinical features that are used in diagnostic lung imaging, i.e., A-lines and B-lines, with a clear relationship to known underlying anatomical structures. Both the oblique and parasagittal views are successfully modeled with the latter producing the characteristic “bat sign,” arising from the ribs and intercostal part of the pleura. These simulations also establish a quantitative link between the percentage of fluid in exudative regions and the appearance of B-lines, suggesting that the B-mode may be used as a quantitative imaging modality.