MZMarek Zelechowski

Marek Zelechowski

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Marek Zelechowski has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Visuomotor mismatch EEG responses over occipital cortex of freely moving human subjects

    by Magdalena Solyga, Marek Zelechowski, Georg B Keller

    Likely the strongest predictor of visual feedback is self-motion. In mice, the coupling between movement and visual feedback is learned with first visual experience of the world, and brief perturbations of the coupling result in strong visuomotor mismatch responses in visual cortex that possibly reflect prediction errors. In humans, predictive coding has primarily been studied using oddball paradigms, which rely on violations of stimulus probability based on recent sensory history. It was still unclear, however, whether humans exhibit visuomotor mismatch responses similar to those observed in mice. This question was important for two reasons. First, visuomotor mismatch responses in humans constitute a basis to start translating the mechanistic understanding of the circuit that computes these responses from mouse to human cortex. Second, a paradigm that can trigger strong prediction error responses and consequently requires shorter recording times would simplify experiments in a clinical setting. Here, by combining a wireless EEG recording system with a virtual reality headset, we found robust visuomotor mismatch responses in human cortex that were characterized by a reversed polarity relative to visual-evoked responses and a greater signal power than both visual responses and oddball mismatch responses.

  • Open Access

    Visuomotor mismatch EEG responses over occipital cortex of freely moving human subjects

    by Magdalena Solyga, Marek Zelechowski, Georg B. Keller

    SUMMARY: Likely the strongest predictor of visual feedback is self-motion. In mice, the coupling between movement and visual feedback is learned with first visual experience of the world (Attinger et al., 2017), and brief perturbations of the coupling result in strong visuomotor mismatch responses in visual cortex that possibly reflect prediction errors (Keller et al., 2012; Zmarz and Keller, 2016). In humans, predictive coding has primarily been studied using oddball paradigms which rely on violations of stimulus probability based on recent sensory history. It was still unclear, however, whether humans exhibit visuomotor mismatch responses similar to those observed in mice. This question was important for two reasons. First, visuomotor mismatch responses in humans constitute a basis to start translating the mechanistic understanding of the circuit that computes these responses from mouse to human cortex. Second, a paradigm that can trigger strong prediction error responses and consequently requires shorter recording times would simplify experiments in a clinical setting. Here, by combining a wireless EEG recording system with a virtual reality headset, we found robust visuomotor mismatch responses in human cortex that were characterized by a reversed polarity relative to visual evoked responses and a greater signal power than both visual responses and oddball mismatch responses.


  • Open Access

    Augmented reality navigation in orthognathic surgery: Comparative analysis and a paradigm shift

    by Marek Żelechowski, Jokin Zubizarreta‐Oteiza, Murali Karnam, Balázs Faludi, Norbert Zentai, Nicolas Gerig, Georg Rauter, Florian M. Thieringer, Philippe C. Cattin

    The emergence of augmented reality (AR) in surgical procedures could significantly enhance accuracy and outcomes, particularly in the complex field of orthognathic surgery. This study compares the effectiveness and accuracy of traditional drilling guides with two AR‐based navigation techniques: one utilizing ArUco markers and the other employing small‐workspace infrared tracking cameras for a drilling task. Additionally, an alternative AR visualization paradigm for surgical navigation is proposed that eliminates the potential inaccuracies of image detection using headset cameras. Through a series of controlled experiments designed to assess the accuracy of hole placements in surgical scenarios, the performance of each method was evaluated both quantitatively and qualitatively. The findings reveal that the small‐workspace infrared tracking camera system is on par with the accuracy of conventional drilling guides, hinting at a promising future where such guides could become obsolete. This technology demonstrates a substantial advantage by circumventing the common issues encountered with traditional tracking systems and surpassing the accuracy of ArUco marker‐based navigation. These results underline the potential of this system for enabling more minimally invasive interventions, a crucial step towards enhancing surgical accuracy and, ultimately, patient outcomes. The study resulted in three relevant contributions: first, a new paradigm for AR visualization in the operating room, relying only on exact tracking information to navigate the surgeon is proposed. Second, the comparative analysis marks a critical step forward in the evolution of surgical navigation, paving the way for integrating more sophisticated AR solutions in orthognathic surgery and beyond. Finally, the system with a robotic arm is integrated and the inaccuracies present in a typical human‐controlled system are evaluated.


  • Open Access

    Assessment of Interrater Reliability and Accuracy of Cerebral Aneurysm Morphometry Using 3D Virtual Reality, 2D Digital Subtraction Angiography, and 3D Reconstruction: A Randomized Comparative Study

    by Attill Saemann, Daniel de Wilde, Jonathan Rychen, Michel Roethlisberger, Marek Żelechowski, Balázs Faludi, Philippe Claude Cattin, Marios-Nikos Psychogios, Jehuda Soleman, Raphael Guzman

    Background/Objectives: Detailed morphometric analysis of an aneurysm and the related vascular bifurcation are critical factors when determining rupture risk and planning treatment for unruptured intracranial aneurysms (UIAs). The standard visualization of digital subtraction angiography (DSA) and its 3D reconstruction on a 2D monitor provide precise measurements but are subject to variability based on the rater. Visualization using virtual (VR) and augmented reality platforms can overcome those limitations. It is, however, unclear whether accurate measurements of the aneurysm and adjacent arterial branches can be obtained on VR models. This study aimed to assess interrater reliability and compare measurements between 3D VR, standard 2D DSA, and 3D DSA reconstructions, evaluating the reliability and accuracy of 3D VR as a measurement tool. Methods: A pool of five neurosurgeons performed three individual analyses on each of the ten UIA cases, measuring them in completely immersed 3D VR and the standard on-screen format (2D DSA and 3D reconstruction). This resulted in three independent measurements per modality for each case. Interrater reliability of measurements and morphology characterization, comparative differences, measurement duration, and VR user experience were assessed. Results: Interrater reliability for 3D VR measurements was significantly higher than for 3D DSA measurements (3D VR mean intraclass correlation coefficient [ICC]: 0.69 ± 0.22 vs. 3D DSA mean ICC: 0.36 ± 0.37, p = 0.042). No significant difference was observed between 3D VR and 2D DSA (3D VR mean ICC: 0.69 ± 0.22 vs. 2D DSA mean ICC: 0.43 ± 0.31, p = 0.12). A linear mixed-effects model showed no effect of 3D VR and 3D DSA (95% CI = −0.26–0.28, p = 0.96) or 3D VR and 2D DSA (95% CI = −0.02–0.53, p = 0.066) on absolute measurements of the aneurysm in the anteroposterior, mediolateral, and craniocaudal dimensions. Conclusions: 3D VR technology allows for reproducible, accurate, and reliable measurements comparable to measurements performed on a 2D screen. It may also potentially improve precision for measurements of non-planar aneurysm dimensions.


  • Open Access

    Automatic patient positioning based on robot rotational workspace for extended reality

    by Marek Żelechowski, Balázs Faludi, Murali Karnam, Nicolas Gerig, Georg Rauter, Philippe C. Cattin

    Purpose: Understanding the properties and aspects of the robotic system is essential to a successful medical intervention, as different capabilities and limits characterize each. Robot positioning is a crucial step in the surgical setup that ensures proper reachability to the desired port locations and facilitates docking procedures. This very demanding task requires much experience to master, especially with multiple trocars, increasing the barrier of entry for surgeons in training. Methods: Previously, we demonstrated an Augmented Reality-based system to visualize the rotational workspace of the robotic system and proved it helps the surgical staff to optimize patient positioning for single-port interventions. In this work, we implemented a new algorithm to allow for an automatic, real-time robotic arm positioning for multiple ports. Results: Our system, based on the rotational workspace data of the robotic arm and the set of trocar locations, can calculate the optimal position of the robotic arm in milliseconds for the positional and in seconds for the rotational workspace in virtual and augmented reality setups. Conclusions: Following the previous work, we extended our system to support multiple ports to cover a broader range of surgical procedures and introduced the automatic positioning component. Our solution can decrease the surgical setup time and eliminate the need to repositioning the robot mid-procedure and is suitable both for the preoperative planning step using VR and in the operating room—running on an AR headset.


  • Workspace-aware Planning of a Surgical Robot Mounting in Virtual Reality

    by Murali Karnam, Marek Zelechowski, Philippe C. Cattin, Georg Rauter, Nicolas Gerig


  • Volume Rendering-Based Patient Registration for Extended Reality

    by Marek Żelechowski, Balázs Faludi, Georg Rauter, Philippe C. Cattin

  • Patient positioning by visualising surgical robot rotational workspace in augmented reality

    by Marek Żelechowski, Murali Karnam, Balázs Faludi, Nicolas Gerig, Georg Rauter, Philippe C. Cattin

    Surgical robots have been the focal point of minimally invasive approaches in the last decades, gradually changing laparoscopic procedures. Robotic platforms offer many advantages that assist the surgeon, including a magnified view of the operative field, motion stability, and 3D visualisation. Understanding the characteristics and limitations of the robot’s workspace is crucial for a successful intervention. Proper positioning of the patient with respect to the robot ensures optimal intraoperative reachability of the desired target regions by the robot and eliminates the need to reposition. In this work, we present a workspace visualisation system using augmented reality. We aim to assist the user wearing a head-mounted display with placing the patient in an optimal position in preparation for the robotic surgery. We evaluated three possible modes of presenting rotational workspace information to the user and quantitatively assessed the placement accuracy. We demonstrated the effectiveness of the implemented solution to increase the robot’s effective range of motion at the surgical port location.