Simon Lauber
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Simon Lauber has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
C. Burandt
5 shared publicationsF. Dziuba
5 shared publicationsJ. List
5 shared publicationsK. Aulenbacher
5 shared publications- Stepan Yaramyshev
GSI Helmholtzzentrum für Schwerionenforschung, 64291 Darmstadt, Germany
5 shared publications V. Gettmann
5 shared publications
Latest Publications
- Open Access
- 5 April 2024
- Published by Springer Nature in EPJ Techniques and Instrumentation
- Vol. 11 (1) , 1-15
Alternating phase focusing beam dynamics for drift tube linacs
In contrast to conventional E-mode resonance accelerators, H-mode DTLs provide for compact linac sections and have been established as highly efficient resonators during the last decades. Thus, H-mode structures are widely applied for heavy-ion acceleration with medium beam energies because of their outstanding capability to provide high acceleration gradients with relatively low energy consumption. To build upon those advantages, an alternating phase focusing beam dynamics layout has been applied to provide for a resonance accelerator design without internal lenses, which allows for eased commissioning, routine operation, maintenance, and potential future upgrades. The features of such a channel are going to be demonstrated on the example of two interdigital H-mode cavities, separated by an external quadrupole triplet. This setup provides for heavy ion (mass-to-charge ratio $A/z\le 6$ A / z ≤ 6 ) acceleration from 300 keV/u to 1400 keV/u and is used as an injector part of the superconducting continuous wave accelerator HELIAC. Hence, this promising approach generally enables effective and compact routine operation for various applications, such as super heavy ion research, material science, and radio biological applications such as heavy-ion tumor therapy.
- 5 April 2024
- Published by Springer Nature in EPJ Techniques and Instrumentation
- Vol. 11 (1) , 1-15
Open AccessAlternating phase focusing beam dynamics for drift tube linacs
In contrast to conventional E-mode resonance accelerators, H-mode DTLs provide for compact linac sections and have been established as highly efficient resonators during the last decades. Thus, H-mode structures are widely applied for heavy-ion acceleration with medium beam energies because of their outstanding capability to provide high acceleration gradients with relatively low energy consumption. To build upon those advantages, an alternating phase focusing beam dynamics layout has been applied to provide for a resonance accelerator design without internal lenses, which allows for eased commissioning, routine operation, maintenance, and potential future upgrades. The features of such a channel are going to be demonstrated on the example of two interdigital H-mode cavities, separated by an external quadrupole triplet. This setup provides for heavy ion (mass-to-charge ratio $A/z\le 6$ A / z ≤ 6 ) acceleration from 300 keV/u to 1400 keV/u and is used as an injector part of the superconducting continuous wave accelerator HELIAC. Hence, this promising approach generally enables effective and compact routine operation for various applications, such as super heavy ion research, material science, and radio biological applications such as heavy-ion tumor therapy.
- Open Access
- 21 July 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (14) , 8422
DYNAMION—A Powerful Beam Dynamics Software Package for the Development of Ion Linear Accelerators and Decelerators
Numerous ambitious particle accelerator facilities, based on proton and ion linear accelerators, have recently been in development for fundamental research, as well as for industrial applications. The advanced design of such new machines, as well as the upgrade and optimization of existing linacs, requires adequate, precise and reliable tools to simulate beam dynamics. The software package DYNAMION, created about 30 years ago, is undergoing systematic improvement and further development in order to characterize modern ion linacs and to provide solutions for its intrinsic complex problems. The DYNAMION code features Front to End beam dynamics simulations under space charge conditions in a linac system, comprising an arbitrary sequence of accelerating-focusing structures and beam transport lines. The evolution of a macroparticle ensemble could be analyzed at a high level of specification. A 3D distribution of the external electrical field (RFQ, DTL) is modeled using integrated internal solvers. Optionally, a 3D electromagnetic field mapping, supplied by specialized external codes, could be used. The recent status of the DYNAMION software package is presented in this paper. Furthermore, the performance of the code is demonstrated on the basis of its application for various linear accelerator/decelerator projects.
- 21 July 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (14) , 8422
Open AccessDYNAMION—A Powerful Beam Dynamics Software Package for the Development of Ion Linear Accelerators and Decelerators
Numerous ambitious particle accelerator facilities, based on proton and ion linear accelerators, have recently been in development for fundamental research, as well as for industrial applications. The advanced design of such new machines, as well as the upgrade and optimization of existing linacs, requires adequate, precise and reliable tools to simulate beam dynamics. The software package DYNAMION, created about 30 years ago, is undergoing systematic improvement and further development in order to characterize modern ion linacs and to provide solutions for its intrinsic complex problems. The DYNAMION code features Front to End beam dynamics simulations under space charge conditions in a linac system, comprising an arbitrary sequence of accelerating-focusing structures and beam transport lines. The evolution of a macroparticle ensemble could be analyzed at a high level of specification. A 3D distribution of the external electrical field (RFQ, DTL) is modeled using integrated internal solvers. Optionally, a 3D electromagnetic field mapping, supplied by specialized external codes, could be used. The recent status of the DYNAMION software package is presented in this paper. Furthermore, the performance of the code is demonstrated on the basis of its application for various linear accelerator/decelerator projects.
- Open Access
- 5 July 2022
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1040
An Alternating Phase Focusing injector for heavy ion acceleration
- 5 July 2022
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1040
Open AccessAn Alternating Phase Focusing injector for heavy ion acceleration
- Open Access
- 1 June 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (6) , 063303
Continuous wave interdigital H-mode cavities for alternating phase focusing heavy ion acceleration
In the future, a new superconducting (SC) continuous wave (CW) high intensity heavy ion HElmholtz LInear ACcelerator (HELIAC) should provide ion beams with maximum beam energy above the Coulomb barrier for the Super Heavy Element program at GSI (Gesellschaft für Schwerionenforschung, in Engl.: Association for Heavy Ion Research). The HELIAC consists of a SC main accelerator supplied by a normal conducting injector, which comprises an electron cyclotron resonance ion source, a radio-frequency quadrupole, and two separate interdigital H-mode drift-tube linear accelerator cavities, based on an Alternating Phase Focusing (APF) scheme. Together, both cavities will accelerate ions from 300 to 1400 keV/u with only one external quadrupole triplet for transverse focusing in between. Due to the demanding requirements of the APF concept on the voltage distribution along the beam axis on the one hand and the CW operation on the other hand, the optimization of each cavity concerning RF, mechanical, and thermal properties is crucial for the successful operation of the HELIAC injector.
- 1 June 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (6) , 063303
Open AccessContinuous wave interdigital H-mode cavities for alternating phase focusing heavy ion acceleration
In the future, a new superconducting (SC) continuous wave (CW) high intensity heavy ion HElmholtz LInear ACcelerator (HELIAC) should provide ion beams with maximum beam energy above the Coulomb barrier for the Super Heavy Element program at GSI (Gesellschaft für Schwerionenforschung, in Engl.: Association for Heavy Ion Research). The HELIAC consists of a SC main accelerator supplied by a normal conducting injector, which comprises an electron cyclotron resonance ion source, a radio-frequency quadrupole, and two separate interdigital H-mode drift-tube linear accelerator cavities, based on an Alternating Phase Focusing (APF) scheme. Together, both cavities will accelerate ions from 300 to 1400 keV/u with only one external quadrupole triplet for transverse focusing in between. Due to the demanding requirements of the APF concept on the voltage distribution along the beam axis on the one hand and the CW operation on the other hand, the optimization of each cavity concerning RF, mechanical, and thermal properties is crucial for the successful operation of the HELIAC injector.
- Open Access
- 1 November 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (11) , 113306
A dynamic collimation and alignment system for the Helmholtz linear accelerator
The upcoming commissioning of the superconducting (SC) continuous wave Helmholtz linear accelerators first of series cryomodule is going to demand precise alignment of the four internal SC cavities and two SC solenoids. For optimal results, a beam-based alignment method is used to reduce the misalignment of the whole cryomodule, as well as its individual components. A symmetric beam of low transverse emittance is required for this method, which is to be formed by a collimation system. It consists of two separate plates with milled slits, aligned in the horizontal and vertical direction. The collimation system and alignment measurements are proposed, investigated, and realized. The complete setup of this system and its integration into the existing environment at the GSI High Charge State Injector are presented, as well as the results of the recent reference measurements.
- 1 November 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (11) , 113306
Open AccessA dynamic collimation and alignment system for the Helmholtz linear accelerator
The upcoming commissioning of the superconducting (SC) continuous wave Helmholtz linear accelerators first of series cryomodule is going to demand precise alignment of the four internal SC cavities and two SC solenoids. For optimal results, a beam-based alignment method is used to reduce the misalignment of the whole cryomodule, as well as its individual components. A symmetric beam of low transverse emittance is required for this method, which is to be formed by a collimation system. It consists of two separate plates with milled slits, aligned in the horizontal and vertical direction. The collimation system and alignment measurements are proposed, investigated, and realized. The complete setup of this system and its integration into the existing environment at the GSI High Charge State Injector are presented, as well as the results of the recent reference measurements.
- Open Access
- 13 November 2020
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 23 (11) , 114201
Longitudinal phase space reconstruction for a heavy ion accelerator
At the GSI Helmholtzzentrum fur Schwerionenforschung (GSI) in Darmstadt, Germany, a prototype cryomodule (advanced demonstrator) for the superconducting (SC) continuous wave (CW) Helmholtz Linear Accelerator (HELIAC) is under construction. A transport line, comprising quadrupole lenses, rebuncher cavities, beam correctors, and adequate beam instrumentation has been built to deliver the beam from the GSI 1.4 MeV/u High Charge Injector (HLI) to the advanced demonstrator, which offers a test environment for SC CW multigap cavities. In order to achieve proper phase space matching, the beam from the HLI must be characterized in detail. In a dedicated machine experiment the bunch shape has been measured with a nondestructive bunch shape monitor (BSM). Therefore, different bunch projections were obtained by altering the voltage of two rebunchers. These measurements were combined with dedicated beam dynamics simulations using the particle tracking code DYNAMION. The longitudinal bunch shape and density distribution at the beginning of the matching line are fully characterized by a tomographic reconstruction method based on a non-negative least square minimization approach.
- 13 November 2020
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 23 (11) , 114201
Open AccessLongitudinal phase space reconstruction for a heavy ion accelerator
At the GSI Helmholtzzentrum fur Schwerionenforschung (GSI) in Darmstadt, Germany, a prototype cryomodule (advanced demonstrator) for the superconducting (SC) continuous wave (CW) Helmholtz Linear Accelerator (HELIAC) is under construction. A transport line, comprising quadrupole lenses, rebuncher cavities, beam correctors, and adequate beam instrumentation has been built to deliver the beam from the GSI 1.4 MeV/u High Charge Injector (HLI) to the advanced demonstrator, which offers a test environment for SC CW multigap cavities. In order to achieve proper phase space matching, the beam from the HLI must be characterized in detail. In a dedicated machine experiment the bunch shape has been measured with a nondestructive bunch shape monitor (BSM). Therefore, different bunch projections were obtained by altering the voltage of two rebunchers. These measurements were combined with dedicated beam dynamics simulations using the particle tracking code DYNAMION. The longitudinal bunch shape and density distribution at the beginning of the matching line are fully characterized by a tomographic reconstruction method based on a non-negative least square minimization approach.
- Open Access
- 1 November 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1350 (1) , 012075
Advanced Beam Dynamics Design for the Superconducting Heavy Ion Accelerator HELIAC
The standalone superconducting (SC) continuous wave (CW) heavy ion linac HELIAC (HElmholtz LInear ACcelerator) is a common project of GSI and HIM under key support of IAP Frankfurt and in collaboration with Moscow Engineering Physics Institute (MEPhI) and Moscow Institute for Theoretical and Experimental Physics (KI-ITEP). It is intended for future experiments with heavy ions near the Coulomb barrier within super-heavy element (SHE) research and aims at developing a linac with multiple CH cavities as key components downstream the High Charge State Injector (HLI) at GSI. The design is challenging due to the requirement of intense beams in CW mode up to a mass-to-charge ratio of 6, while covering a broad output energy range from 3.5 to 7.3MeV/u with minimum energy spread. In 2017 the first superconducting section of the linac has been successfully commissioned and extensively tested with beam at GSI. In the light of experience gained in this research so far, the beam dynamics layout for the entire linac has recently been updated and optimized with particular emphasis on realistic assumptions of cavity gap and drift lengths as well as gap voltage distributions for CH3-CH11.
- 1 November 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1350 (1) , 012075
Open AccessAdvanced Beam Dynamics Design for the Superconducting Heavy Ion Accelerator HELIAC
The standalone superconducting (SC) continuous wave (CW) heavy ion linac HELIAC (HElmholtz LInear ACcelerator) is a common project of GSI and HIM under key support of IAP Frankfurt and in collaboration with Moscow Engineering Physics Institute (MEPhI) and Moscow Institute for Theoretical and Experimental Physics (KI-ITEP). It is intended for future experiments with heavy ions near the Coulomb barrier within super-heavy element (SHE) research and aims at developing a linac with multiple CH cavities as key components downstream the High Charge State Injector (HLI) at GSI. The design is challenging due to the requirement of intense beams in CW mode up to a mass-to-charge ratio of 6, while covering a broad output energy range from 3.5 to 7.3MeV/u with minimum energy spread. In 2017 the first superconducting section of the linac has been successfully commissioned and extensively tested with beam at GSI. In the light of experience gained in this research so far, the beam dynamics layout for the entire linac has recently been updated and optimized with particular emphasis on realistic assumptions of cavity gap and drift lengths as well as gap voltage distributions for CH3-CH11.
- Open Access
- 1 November 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1350 (1) , 012073
Reconstruction of the longitudinal phase portrait for the SC CW heavy ion HELIAC at GSI
At the GSI Helmholtzzentrum für Schwerionenforschung (GSI) in Darmstadt, Germany, the HElmholtz LInear Accelerator (HELIAC) is currently under construction. The HELIAC comprises superconducting multigap Crossbar H-mode (SC CH) cavities. The input beam is delivered by an already existing High Charge Injector (HLI). For the further development of the accelerator a detailed knowledge of the input beam parameters to the SC section is necessary. A method for beam reconstruction is incorporated, which provides for longitudinal beam characteristics using measurements with a beam shape monitor and a particle simulation code. This finalizes the investigations on 6D beam parameters, following previous measurements in transversal phase space. The reconstruction of the longitudinal phase portrait is presented.
- 1 November 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1350 (1) , 012073
Open AccessReconstruction of the longitudinal phase portrait for the SC CW heavy ion HELIAC at GSI
At the GSI Helmholtzzentrum für Schwerionenforschung (GSI) in Darmstadt, Germany, the HElmholtz LInear Accelerator (HELIAC) is currently under construction. The HELIAC comprises superconducting multigap Crossbar H-mode (SC CH) cavities. The input beam is delivered by an already existing High Charge Injector (HLI). For the further development of the accelerator a detailed knowledge of the input beam parameters to the SC section is necessary. A method for beam reconstruction is incorporated, which provides for longitudinal beam characteristics using measurements with a beam shape monitor and a particle simulation code. This finalizes the investigations on 6D beam parameters, following previous measurements in transversal phase space. The reconstruction of the longitudinal phase portrait is presented.