Min Jing
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Min Jing has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Dewar Darren Finlay
School of Engineering, Ulster University, Belfast BT15 1ED, UK
3 shared publications - James McLaughlin
Ulster University
3 shared publications Brian Mac Namee
School of Computer Science, University College Dublin, Dublin 4, Ireland
2 shared publications- Sonya Coleman
Intelligent Systems Research Centre, University of Ulster, Derry, UK
2 shared publications - Thomas Martin McGinnity
School of Science and Technology, Nottingham Trent University, Nottingham, UK
2 shared publications - Agnes Awuah
Biomedical Sciences Research Institute, Ulster University, Northern Ireland
1 shared publication
Latest Publications
- Open Access
- 23 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Translational Engineering in Health and Medicine
- Vol. 9, 1-15
A Novel Method for Quantitative Analysis of C-Reactive Protein Lateral Flow Immunoassays Images via CMOS Sensor and Recurrent Neural Networks
Objective: To design and implement an easy-to-use, Point-of-Care (PoC) lateral flow immunoassays (LFA) reader and data analysis system, which provides a more in-depth quantitative analysis for LFA images than conventional approaches thereby supporting efficient decision making for potential early risk assessment of cardiovascular disease (CVD). Methods and procedures: A novel end-to-end system was developed including a portable device with CMOS camera integrated with optimized illumination and optics to capture the LFA images produced using high-sensitivity C-Reactive Protein (hsCRP) (concentration level < 5 mg/L). The images were transmitted via WiFi to a back-end server system for image analysis and classification. Unlike common image classification approaches which are based on averaging image intensity from a region-of-interest (ROI), a novel approach was developed which considered the signal along the sample’s flow direction as a time series and, consequently, no need for ROI detection. Long Short-Term Memory (LSTM) networks were deployed for multilevel classification. The features based on Dynamic Time Warping (DTW) and histogram bin counts (HBC) were explored for classification. Results: For the classification of hsCRP, the LSTM outperformed the traditional machine learning classifiers with or without DTW and HBC features performed the best (with mean accuracy of 94%) compared to other features. Application of the proposed method to human plasma also suggests that HBC features from LFA time series performed better than the mean from ROI and raw LFA data. Conclusion: As a proof of concept, the results demonstrate the capability of the proposed framework for quantitative analysis of LFA images and suggest the potential for early risk assessment of CVD. Clinical impact: The hsCRP levels < 5 mg/L were aligned with clinically actionable categories for early risk assessment of CVD. The outcomes demonstrated the real-world applicability of the proposed system for quantitative analysis of LFA images, which is potentially useful for more LFA applications beyond presented in this study.
- 23 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Translational Engineering in Health and Medicine
- Vol. 9, 1-15
Open AccessA Novel Method for Quantitative Analysis of C-Reactive Protein Lateral Flow Immunoassays Images via CMOS Sensor and Recurrent Neural Networks
Objective: To design and implement an easy-to-use, Point-of-Care (PoC) lateral flow immunoassays (LFA) reader and data analysis system, which provides a more in-depth quantitative analysis for LFA images than conventional approaches thereby supporting efficient decision making for potential early risk assessment of cardiovascular disease (CVD). Methods and procedures: A novel end-to-end system was developed including a portable device with CMOS camera integrated with optimized illumination and optics to capture the LFA images produced using high-sensitivity C-Reactive Protein (hsCRP) (concentration level < 5 mg/L). The images were transmitted via WiFi to a back-end server system for image analysis and classification. Unlike common image classification approaches which are based on averaging image intensity from a region-of-interest (ROI), a novel approach was developed which considered the signal along the sample’s flow direction as a time series and, consequently, no need for ROI detection. Long Short-Term Memory (LSTM) networks were deployed for multilevel classification. The features based on Dynamic Time Warping (DTW) and histogram bin counts (HBC) were explored for classification. Results: For the classification of hsCRP, the LSTM outperformed the traditional machine learning classifiers with or without DTW and HBC features performed the best (with mean accuracy of 94%) compared to other features. Application of the proposed method to human plasma also suggests that HBC features from LFA time series performed better than the mean from ROI and raw LFA data. Conclusion: As a proof of concept, the results demonstrate the capability of the proposed framework for quantitative analysis of LFA images and suggest the potential for early risk assessment of CVD. Clinical impact: The hsCRP levels < 5 mg/L were aligned with clinically actionable categories for early risk assessment of CVD. The outcomes demonstrated the real-world applicability of the proposed system for quantitative analysis of LFA images, which is potentially useful for more LFA applications beyond presented in this study.
- Open Access
- 2 September 2021
- Published by Elsevier in Journal of Biomedical Informatics
- Vol. 122, 103905
COVID-19 modelling by time-varying transmission rate associated with mobility trend of driving via Apple Maps
- 2 September 2021
- Published by Elsevier in Journal of Biomedical Informatics
- Vol. 122, 103905
Open AccessCOVID-19 modelling by time-varying transmission rate associated with mobility trend of driving via Apple Maps
- 1 November 2019
- Published by Elsevier in Microvascular Research
- Vol. 126, 103907
Quantitative assessment of the conjunctival microcirculation using a smartphone and slit-lamp biomicroscope
- 1 November 2019
- Published by Elsevier in Microvascular Research
- Vol. 126, 103907
Quantitative assessment of the conjunctival microcirculation using a smartphone and slit-lamp biomicroscope
P8 Big data platform for cardiovascular healthcare data storage and data viewer
With increasingly generated big data in the healthcare industry, it is vital to develop the platforms for more effective capture, storage and manipulation of such large volume, high velocity and variable data. A central database has been established for cardiovascular healthcare, which enables the data storage and data transformation between the hospital and data analysis centre with a PHP data viewer. The data are collected from sensors and devices in general applied to patients, which are organised and can be searched according to four fields: projects, events, patients and recordings. Data organised in events englobe a session where the patient was assessed. Different events (or sessions) can form a project and the same event could belong to different projects. Each event contains recordings and each recording can be a time series, an image, a video or a punctual datum, such as, video taken for patient’s eye conjunctival, Electrocardiogram (ECG), temperature, blood pressure or respiration rate. The recordings can have associated annotations for classifications, diagnoses, and additional files such as images, reports or notes. Data are stored within the university servers following the approved guidelines on availability and security of the data. Only authorized users can access the database. The data can be accessed by a PHP viewer application which resides in the university servers, in which login and password are required. The user can navigate and search data by four fields. It is also possible to upload retrospective data into the database through the PHP viewer (to create events). Data can be also uploaded live by Android apps which capture data from a sensor or directly from electronic boards (controlling the sensors) connected via Wi-Fi. Figure 1 (a) shows the relational model of the database, (b) lists different recordings for an event and (c) shows a time series data (ECG). Further extension of the platform will enable the algorithms, trend analysis and analytical methodologies to be developed and operated, which will form the basis of a static and cloud-based platform solution for cardiovascular healthcare research and applications. (a) Relational model for NIBEC database; (b) screenshot of the database PHP viewer showing recordings of one event; (c) screenshot of an example of ECG recoding from this event. This project has been funded by the EU’s INTERREG VA programme, managed by the Special EU Programmes Body (SEUPB).
P8 Big data platform for cardiovascular healthcare data storage and data viewer
With increasingly generated big data in the healthcare industry, it is vital to develop the platforms for more effective capture, storage and manipulation of such large volume, high velocity and variable data. A central database has been established for cardiovascular healthcare, which enables the data storage and data transformation between the hospital and data analysis centre with a PHP data viewer. The data are collected from sensors and devices in general applied to patients, which are organised and can be searched according to four fields: projects, events, patients and recordings. Data organised in events englobe a session where the patient was assessed. Different events (or sessions) can form a project and the same event could belong to different projects. Each event contains recordings and each recording can be a time series, an image, a video or a punctual datum, such as, video taken for patient’s eye conjunctival, Electrocardiogram (ECG), temperature, blood pressure or respiration rate. The recordings can have associated annotations for classifications, diagnoses, and additional files such as images, reports or notes. Data are stored within the university servers following the approved guidelines on availability and security of the data. Only authorized users can access the database. The data can be accessed by a PHP viewer application which resides in the university servers, in which login and password are required. The user can navigate and search data by four fields. It is also possible to upload retrospective data into the database through the PHP viewer (to create events). Data can be also uploaded live by Android apps which capture data from a sensor or directly from electronic boards (controlling the sensors) connected via Wi-Fi. Figure 1 (a) shows the relational model of the database, (b) lists different recordings for an event and (c) shows a time series data (ECG). Further extension of the platform will enable the algorithms, trend analysis and analytical methodologies to be developed and operated, which will form the basis of a static and cloud-based platform solution for cardiovascular healthcare research and applications. (a) Relational model for NIBEC database; (b) screenshot of the database PHP viewer showing recordings of one event; (c) screenshot of an example of ECG recoding from this event. This project has been funded by the EU’s INTERREG VA programme, managed by the Special EU Programmes Body (SEUPB).
- Open Access
- 1 November 2017
- Published by Elsevier in Journal of Visual Communication and Image Representation
- Vol. 49, 371-381
Novel “Squiral” (square spiral) architecture for fast image processing
- 1 November 2017
- Published by Elsevier in Journal of Visual Communication and Image Representation
- Vol. 49, 371-381
Open AccessNovel “Squiral” (square spiral) architecture for fast image processing
- 1 August 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 23 (1094687X) , 2706-2709
Incorporating independent component analysis to Q-ball imaging for diffusion orientation distribution reconstruction
In this paper, we investigate the incorporation of independent component analysis (ICA) with Q-ball imaging (QBI) to extract information on the diffusion orientation distribution function (ODF) from an inner voxel. In our approach, the ICA algorithm is applied to a mixture of ODFs which are constructed based on the analytical QBI solution. The numerical simulation results demonstrate that the proposed ICA framework can not only successfully separate the diffusion ODF from the noisy diffusion data, but also achieves better performance compared with a QBI solution when the data has a low signal to noise ratio (SNR).
- 1 August 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 23 (1094687X) , 2706-2709
Incorporating independent component analysis to Q-ball imaging for diffusion orientation distribution reconstruction
In this paper, we investigate the incorporation of independent component analysis (ICA) with Q-ball imaging (QBI) to extract information on the diffusion orientation distribution function (ODF) from an inner voxel. In our approach, the ICA algorithm is applied to a mixture of ODFs which are constructed based on the analytical QBI solution. The numerical simulation results demonstrate that the proposed ICA framework can not only successfully separate the diffusion ODF from the noisy diffusion data, but also achieves better performance compared with a QBI solution when the data has a low signal to noise ratio (SNR).