Vagarshak M. Aivazyan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Vagarshak M. Aivazyan has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Anton P. Broyko
СПбГЭТУ "ЛЭТИ
2 shared publications - Ivan K. Khmelnitskiy
Research and Education Center “Nanotechnologies” / Faculty of Electronics, Saint-Petersburg Electrotechnical University “LETI”, St. Petersburg, Russia
2 shared publications - Nikolay I. Alekseyev
St. Petersburg Electrotechnical University (LETI), St. Petersburg, Russia
2 shared publications - Victor V. Luchinin
St. Petersburg State Electrotechnical University “LETI”, St. Petersburg, Russia
2 shared publications A.E. Petukhov
1 shared publication- Alexander V. Kolyadin
OOO NPK Almaz, Sestroretsk, Russia
1 shared publication
Latest Publications
- 22 September 2025
- Published by Springer Nature in Biomedical Engineering
- Vol. 59 (3) , 1-5
A sensor glove with conformal sensors based on ionic electroactive polymers for biomedical applications
- 22 September 2025
- Published by Springer Nature in Biomedical Engineering
- Vol. 59 (3) , 1-5
A sensor glove with conformal sensors based on ionic electroactive polymers for biomedical applications
- Open Access
Temperature- and Pressure-Reducing Regimes in the Growth Cell of HPHT Diamonds, Optimal for Preserving Crystal Integrity after Growth Completion
With its exceptional strength characteristics, diamond has some mechanical drawbacks, significant brittleness being among them. In particular, some HPHT-grown diamonds crack when the extreme parameters inherent to the diamond growth process gradually decrease. The cracking is caused by excessive stress due to the poor plastic properties of the diamond growth catalytic medium at certain stages of reducing the pressure and the temperature. An insulating container with the growth cell and heating circuit fragment inside can also make a significant contribution to the probability of cracking. This paper considers the possibility of minimizing the mechanical stress in the growth cell and, consequently, in the diamond crystal by choosing the optimal trajectory for the decrease in the pressure and temperature from diamond growth conditions to normal conditions.
Open AccessTemperature- and Pressure-Reducing Regimes in the Growth Cell of HPHT Diamonds, Optimal for Preserving Crystal Integrity after Growth Completion
With its exceptional strength characteristics, diamond has some mechanical drawbacks, significant brittleness being among them. In particular, some HPHT-grown diamonds crack when the extreme parameters inherent to the diamond growth process gradually decrease. The cracking is caused by excessive stress due to the poor plastic properties of the diamond growth catalytic medium at certain stages of reducing the pressure and the temperature. An insulating container with the growth cell and heating circuit fragment inside can also make a significant contribution to the probability of cracking. This paper considers the possibility of minimizing the mechanical stress in the growth cell and, consequently, in the diamond crystal by choosing the optimal trajectory for the decrease in the pressure and temperature from diamond growth conditions to normal conditions.
- Open Access
Ionic EAP Actuators with Electrodes Based on Carbon Nanomaterials
Flexible polymer-based actuators, often also called artificial muscles, are an essential part of biomimetic systems that mimic the movement principles of animal world creatures. The most used electrode material to force the actuator move is an ensemble of noble metal nanoparticles in the electroactive polymer surface. Noble metal electrodes have enough electrical conductivity and elasticity and are not subjected to oxidation. However, high cost of such electrodes and their tendency to cracking dictate the need for searching other materials, primarily carbon ones. The review considers several options for this search. For example, carbon nanotubes and graphene have excellent properties at the level of a single individually taken nanotube or graphene sheet. However, conservation of these properties in structurally imperfect film electrodes requires a separate study. In addition, there are problems of compatibility of such electrodes with the polymers that requires cumbersome technologies, e.g., hot pressing, which complicates the production of the actuator as a whole. The review concerns the technology options of manufacturing actuators and the results obtained on their basis, both including hot pressing and avoiding this procedure. In particular, the required level of the graphene oxide reduction in hydrazine provides sufficient adhesion at rather high electrical conductivity of the graphene film. The ability to simultaneous achieving these properties is a nontrivial result, providing the same level of actuation as with expensive noble metal electrodes. Actuators that additionally require greater lifetime resource should be obtained in other ways. Among them are using the graphdiyne electrodes and laser processing of the graphene electrodes.
Open AccessIonic EAP Actuators with Electrodes Based on Carbon Nanomaterials
Flexible polymer-based actuators, often also called artificial muscles, are an essential part of biomimetic systems that mimic the movement principles of animal world creatures. The most used electrode material to force the actuator move is an ensemble of noble metal nanoparticles in the electroactive polymer surface. Noble metal electrodes have enough electrical conductivity and elasticity and are not subjected to oxidation. However, high cost of such electrodes and their tendency to cracking dictate the need for searching other materials, primarily carbon ones. The review considers several options for this search. For example, carbon nanotubes and graphene have excellent properties at the level of a single individually taken nanotube or graphene sheet. However, conservation of these properties in structurally imperfect film electrodes requires a separate study. In addition, there are problems of compatibility of such electrodes with the polymers that requires cumbersome technologies, e.g., hot pressing, which complicates the production of the actuator as a whole. The review concerns the technology options of manufacturing actuators and the results obtained on their basis, both including hot pressing and avoiding this procedure. In particular, the required level of the graphene oxide reduction in hydrazine provides sufficient adhesion at rather high electrical conductivity of the graphene film. The ability to simultaneous achieving these properties is a nontrivial result, providing the same level of actuation as with expensive noble metal electrodes. Actuators that additionally require greater lifetime resource should be obtained in other ways. Among them are using the graphdiyne electrodes and laser processing of the graphene electrodes.