A. O. Kovalchuk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
A. O. Kovalchuk has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
A. I. Dovhaliuk
Department of Histology and Embryology, Ivan Horbachevsky Ternopil National Medical University, Ternopil, Ukraine
1 shared publicationA. V. Pavlyshyn
1 shared publication- I. I. Medvid
I. HORBACHEVSKY TERNOPIL NATIONAL MEDICAL UNIVERSITY, TERNOPIL, UKRAINE
1 shared publication - I. M. Klishch
IY Horbachevskyi National Medical University, Ternopil, Ukraine
1 shared publication - Mykhaylo M. Korda
Department of Medical Biochemistry, I. Horbachevsky Ternopil National Medical University, Ternopil, Ukraine
1 shared publication - Nataliia Vitaliivna Ohinska
I. HORBACHEVSKY TERNOPIL NATIONAL MEDICAL UNIVERSITY, TERNOPIL, UKRAINE
1 shared publication
Latest Publications
- 3 August 2026
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in The Ukrainian Biochemical Journal
- Vol. 98 (4) , 108-126
Acellular dermal matrix for chronic wound treatment: dry or wet?
Background. Chronic wounds pose a serious clinical and economic burden, and their effective treatment requires the development of new biomaterials that promote tissue regeneration. Acellular dermal matrices (ADMs) represent a promising regenerative strategy; however, their biological properties largely depend on the manufacturing protocol. Objective. To compare the biocompatibility and cytotoxicity of two porcine acellular dermal matrix variants, dry (d-ADM) and wet (w-ADM), and to evaluate the therapeutic efficacy of the biocompatible matrix in an experimental porcine model of chronic full-thickness wounds. Methods. Biocompatibility was assessed in vitro using human umbilical cord-derived mesenchymal stem cells (hU-MSCs) by evaluating cell morphology, viability, proliferation, and lactate dehydrogenase (LDH) release. The therapeutic efficacy of the selected ADM was investigated in a porcine chronic full-thickness excisional wound model and compared with non-adhesive dressings and Promogran Prisma. Wound healing was evaluated after 28 days using histological, immunohistochemical (TNF-α, TGF-β, Ki-67), and morphometric analyses. Results. The wet ADM preserved hU-MSC morphology, viability, and proliferative capacity, whereas the dry ADM induced marked cytotoxicity, increased LDH release, and extensive cell death. In vivo, treatment with w-ADM significantly accelerated wound healing compared with both control dressings, resulting in complete and stable re-epithelialization, minimal inflammatory infiltration, organized collagen remodeling, and improved tissue architecture. Immunohistochemical analysis demonstrated significantly lower expression of TNF-α, TGF-β, and Ki-67, indicating resolution of inflammation and transition toward tissue remodeling and regenerative stabilization. Conclusions. Wet acellular dermal matrix demonstrated excellent biocompatibility and superior regenerative performance, whereas the dry matrix exhibited unacceptable cytotoxicity. Wet ADM represents a promising scaffold for regenerative treatment of chronic wounds and warrants further investigation as a clinically applicable biomaterial, including in combination with mesenchymal stem cell-based therapies. Keywords: acellular dermal matrix, biocompatibility, chronic wounds, cytotoxicity, human umbilical mesenchymal stem cells, lyophilization, morphology
- 3 August 2026
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in The Ukrainian Biochemical Journal
- Vol. 98 (4) , 108-126
Acellular dermal matrix for chronic wound treatment: dry or wet?
Background. Chronic wounds pose a serious clinical and economic burden, and their effective treatment requires the development of new biomaterials that promote tissue regeneration. Acellular dermal matrices (ADMs) represent a promising regenerative strategy; however, their biological properties largely depend on the manufacturing protocol. Objective. To compare the biocompatibility and cytotoxicity of two porcine acellular dermal matrix variants, dry (d-ADM) and wet (w-ADM), and to evaluate the therapeutic efficacy of the biocompatible matrix in an experimental porcine model of chronic full-thickness wounds. Methods. Biocompatibility was assessed in vitro using human umbilical cord-derived mesenchymal stem cells (hU-MSCs) by evaluating cell morphology, viability, proliferation, and lactate dehydrogenase (LDH) release. The therapeutic efficacy of the selected ADM was investigated in a porcine chronic full-thickness excisional wound model and compared with non-adhesive dressings and Promogran Prisma. Wound healing was evaluated after 28 days using histological, immunohistochemical (TNF-α, TGF-β, Ki-67), and morphometric analyses. Results. The wet ADM preserved hU-MSC morphology, viability, and proliferative capacity, whereas the dry ADM induced marked cytotoxicity, increased LDH release, and extensive cell death. In vivo, treatment with w-ADM significantly accelerated wound healing compared with both control dressings, resulting in complete and stable re-epithelialization, minimal inflammatory infiltration, organized collagen remodeling, and improved tissue architecture. Immunohistochemical analysis demonstrated significantly lower expression of TNF-α, TGF-β, and Ki-67, indicating resolution of inflammation and transition toward tissue remodeling and regenerative stabilization. Conclusions. Wet acellular dermal matrix demonstrated excellent biocompatibility and superior regenerative performance, whereas the dry matrix exhibited unacceptable cytotoxicity. Wet ADM represents a promising scaffold for regenerative treatment of chronic wounds and warrants further investigation as a clinically applicable biomaterial, including in combination with mesenchymal stem cell-based therapies. Keywords: acellular dermal matrix, biocompatibility, chronic wounds, cytotoxicity, human umbilical mesenchymal stem cells, lyophilization, morphology
- Open Access
- 23 September 2021
- Published by Vinnytsia National Pyrogov Memorial Medical University in Reports of Vinnytsia National Medical University
- Vol. 25 (3) , 466-468
Evaluation of antibacterial and antiviral barrier function of the conceptual model of a pneumatic helmet
Annotation. The global pandemic has necessitated the development of new respiratory protective equipment that seems to combine reliability and ergonomics. The article tests an innovative conceptual model of a pneumatic helmet with a laminar air supply system for its permeability to bacteria Micrococcus luteus and antistaphylococcal bacteriophages. The latter were fed in the form of an aerosol to the external filter of the working device with subsequent titration and seeding. Evaluation of bacterial infection is performed by counting the units that form colonies by multiplying the above indicator by the degree of dilution. The presence of bacteriophages and their number was determined by the Grace method with the calculation of plaque-forming units in the culture of Staphylococcus aureus. Statistical processing of the results was performed on a personal computer Intel Core i3 using one- and multi-factor analysis of variance (licensed software packages Microsoft Office 2016 and Statistica 10). In the full and partial configuration of the device (if there is only an external or internal filter), the penetration of microorganisms into the internal space is not detected. The results of the study confirmed the reliability of the protection system for 6 hours of continuous operation, which makes the conceptual model of a pneumatic helmet a more ergonomic alternative to the usual means of respiratory protection.
- 23 September 2021
- Published by Vinnytsia National Pyrogov Memorial Medical University in Reports of Vinnytsia National Medical University
- Vol. 25 (3) , 466-468
Open AccessEvaluation of antibacterial and antiviral barrier function of the conceptual model of a pneumatic helmet
Annotation. The global pandemic has necessitated the development of new respiratory protective equipment that seems to combine reliability and ergonomics. The article tests an innovative conceptual model of a pneumatic helmet with a laminar air supply system for its permeability to bacteria Micrococcus luteus and antistaphylococcal bacteriophages. The latter were fed in the form of an aerosol to the external filter of the working device with subsequent titration and seeding. Evaluation of bacterial infection is performed by counting the units that form colonies by multiplying the above indicator by the degree of dilution. The presence of bacteriophages and their number was determined by the Grace method with the calculation of plaque-forming units in the culture of Staphylococcus aureus. Statistical processing of the results was performed on a personal computer Intel Core i3 using one- and multi-factor analysis of variance (licensed software packages Microsoft Office 2016 and Statistica 10). In the full and partial configuration of the device (if there is only an external or internal filter), the penetration of microorganisms into the internal space is not detected. The results of the study confirmed the reliability of the protection system for 6 hours of continuous operation, which makes the conceptual model of a pneumatic helmet a more ergonomic alternative to the usual means of respiratory protection.