Grace Keane
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Grace Keane has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Arthur Johannes Anthonius Theodorus Braat
Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, 3584 CX Utrecht, The Netherlands
3 shared publications Hugo de Jong
Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, The Netherlands
3 shared publications- Maarten Leonard Johannes Smits
Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, 3584 CX Utrecht, The Netherlands
3 shared publications - Marnix G. E. H. Lam
Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, 3584 CX Utrecht, The Netherlands
3 shared publications Marnix Lam
Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, The Netherlands
3 shared publications- Hugo W. A. M. de Jong
Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, 3584 CX Utrecht, The Netherlands
2 shared publications
Latest Publications
- Open Access
- 11 August 2026
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 53 (13) , 8217-8228
Predictive value of [99mTc]Tc-MAA SPECT/CT personalised dosimetry in 90Y radioembolization of hepatocellular carcinoma: a DOSISPHERE-01 ancillary study
Purpose: The DOSISPHERE-01 study demonstrated a survival benefit for patients treated with 90 Y radioembolization using personalised [ 99m Tc]Tc-MAA guided versus standard dosimetry guided treatment. This ancillary analysis complements DOSISPHERE-01 by reporting post-treatment dosimetry and assessing agreement between predictive ([ 99m Tc]Tc-MAA) and post-treatment ( 90 Y) absorbed doses. Materials and methods: All DOSISPHERE-01 patients with both pre-treatment [ 99m Tc]Tc-MAA SPECT/CT and post-treatment 90 Y imaging were eligible. Multicompartment dosimetry was performed using two segmentation methods: anatomic (MRI/CT) and count-threshold based (SPECT). Mean normal liver tissue and index-lesion absorbed dose, and dose volume histogram (DVH) metrics were determined using Simplicit 90 Y (Mirada Medical, Oxford UK). Agreement between [ 99m Tc]Tc-MAA and 90 Y absorbed doses was assessed via Bland-Altman and paired-sample analysis, with correlation assessed via linear-regression. Results: Thirty-seven patients were included: 19 from the personalised arm and 18 from the standard dosimetry arm. Pre- and post-treatment absorbed dose differences were not statistically significant for the index lesion (241 Gy vs. 229 Gy, p = 0.15; mean difference 11.9 Gy; 95% LoA − 84.3 to 108.2 Gy), Perfused Volume Normal Liver Tissue (PVNT) (91 Gy vs. 99 Gy, p = 0.14; mean difference − 8.2 Gy; 95% LoA − 71.6 to 55.1 Gy), or DVH metrics (V200, D70, D50) using anatomic segmentation. Corresponding metrics were significantly different using count-threshold segmentation ( p < 0.05). For both methods, pre- and post-treatment mean index lesion and PVNT absorbed doses, and V200, D70, D50 were strongly correlated (Pearsons Correlation Coefficient > 0.65, p < 0.05). Conclusion: 90 Y absorbed dose outcomes in the DOSISPHERE-01 study corresponded closely with [ 99m Tc]Tc-MAA predictive dosimetry, confirming the validity of [ 99m Tc]Tc-MAA for dosimetry-based treatment planning in this clinical scenario. Agreement was maximised using anatomic segmentation.
- 11 August 2026
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 53 (13) , 8217-8228
Open AccessPredictive value of [99mTc]Tc-MAA SPECT/CT personalised dosimetry in 90Y radioembolization of hepatocellular carcinoma: a DOSISPHERE-01 ancillary study
Purpose: The DOSISPHERE-01 study demonstrated a survival benefit for patients treated with 90 Y radioembolization using personalised [ 99m Tc]Tc-MAA guided versus standard dosimetry guided treatment. This ancillary analysis complements DOSISPHERE-01 by reporting post-treatment dosimetry and assessing agreement between predictive ([ 99m Tc]Tc-MAA) and post-treatment ( 90 Y) absorbed doses. Materials and methods: All DOSISPHERE-01 patients with both pre-treatment [ 99m Tc]Tc-MAA SPECT/CT and post-treatment 90 Y imaging were eligible. Multicompartment dosimetry was performed using two segmentation methods: anatomic (MRI/CT) and count-threshold based (SPECT). Mean normal liver tissue and index-lesion absorbed dose, and dose volume histogram (DVH) metrics were determined using Simplicit 90 Y (Mirada Medical, Oxford UK). Agreement between [ 99m Tc]Tc-MAA and 90 Y absorbed doses was assessed via Bland-Altman and paired-sample analysis, with correlation assessed via linear-regression. Results: Thirty-seven patients were included: 19 from the personalised arm and 18 from the standard dosimetry arm. Pre- and post-treatment absorbed dose differences were not statistically significant for the index lesion (241 Gy vs. 229 Gy, p = 0.15; mean difference 11.9 Gy; 95% LoA − 84.3 to 108.2 Gy), Perfused Volume Normal Liver Tissue (PVNT) (91 Gy vs. 99 Gy, p = 0.14; mean difference − 8.2 Gy; 95% LoA − 71.6 to 55.1 Gy), or DVH metrics (V200, D70, D50) using anatomic segmentation. Corresponding metrics were significantly different using count-threshold segmentation ( p < 0.05). For both methods, pre- and post-treatment mean index lesion and PVNT absorbed doses, and V200, D70, D50 were strongly correlated (Pearsons Correlation Coefficient > 0.65, p < 0.05). Conclusion: 90 Y absorbed dose outcomes in the DOSISPHERE-01 study corresponded closely with [ 99m Tc]Tc-MAA predictive dosimetry, confirming the validity of [ 99m Tc]Tc-MAA for dosimetry-based treatment planning in this clinical scenario. Agreement was maximised using anatomic segmentation.
- Open Access
- 11 July 2026
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 53 (12) , 7038-7048
A novel approach to radioembolization treatment planning using a hybrid [99mTc]Tc-MAA contrast enhanced SPECT/CT
Purpose: Dosimetry-guided treatment planning is central to radioembolization. Guidelines recommend segmenting volumes on baseline contrast-enhanced CT (ceCT) and registering to a SPECT/low-dose CT. However, this conventional approach is vulnerable to spatial misregistration and potential disease progression. This study evaluates a hybrid SPECT/ceCT-based planning methodology, hypothesising that it yields significantly different dosimetry metrics compared to the conventional workflow. Materials and methods: Hybrid SPECT/ceCT was performed in 24 patients with hepatocellular carcinoma. Treatment planning followed both the conventional and hybrid workflow, where delineation was performed directly on SPECT/ceCT. Quantification of dosimetric and positional differences between volumes from the two workflows was performed using Simplicit 90 Y (Mirada Medical) and SurePlan Liver Y90 (MIM) software, respectively. Outcomes were evaluated by Bland-Altman analysis and contour intercomparison indices. Results: Direct delineation on SPECT/ceCT yielded higher index lesion (largest single tumour) doses (6% increased) (mean: 19.5 Gy, 95% limits of agreement [LoA]: -43.9 Gy, 83.0 Gy) and lower normal tissue doses (11% decrease) (mean: -17.6 Gy 95% LoA: -104.4 Gy, 69.3 Gy). Index lesion volume increase between baseline CT and SPECT/ceCT was 14% (95% LoA: -55.9%, 82.9%). Index lesion dose ( p = 0.01) and volume ( p = 0.01) differed significantly between workflows. The median time interval between baseline imaging and SPECT/ceCT was 6 weeks (IQR: 3.7 to 9.3 weeks). The median deviation of the index lesion between the baseline diagnostic image and hybrid SPECT/ceCT image was 4.9 ± 2.2 mm and there was an average DICE score of 0.6 ± 0.2. Conclusion: Hybrid [99mTc]Tc-MAA SPECT/ceCT treatment planning is technically feasible and leads to significant differences in dosimetry metrics compared with the conventional method.
- 11 July 2026
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 53 (12) , 7038-7048
Open AccessA novel approach to radioembolization treatment planning using a hybrid [99mTc]Tc-MAA contrast enhanced SPECT/CT
Purpose: Dosimetry-guided treatment planning is central to radioembolization. Guidelines recommend segmenting volumes on baseline contrast-enhanced CT (ceCT) and registering to a SPECT/low-dose CT. However, this conventional approach is vulnerable to spatial misregistration and potential disease progression. This study evaluates a hybrid SPECT/ceCT-based planning methodology, hypothesising that it yields significantly different dosimetry metrics compared to the conventional workflow. Materials and methods: Hybrid SPECT/ceCT was performed in 24 patients with hepatocellular carcinoma. Treatment planning followed both the conventional and hybrid workflow, where delineation was performed directly on SPECT/ceCT. Quantification of dosimetric and positional differences between volumes from the two workflows was performed using Simplicit 90 Y (Mirada Medical) and SurePlan Liver Y90 (MIM) software, respectively. Outcomes were evaluated by Bland-Altman analysis and contour intercomparison indices. Results: Direct delineation on SPECT/ceCT yielded higher index lesion (largest single tumour) doses (6% increased) (mean: 19.5 Gy, 95% limits of agreement [LoA]: -43.9 Gy, 83.0 Gy) and lower normal tissue doses (11% decrease) (mean: -17.6 Gy 95% LoA: -104.4 Gy, 69.3 Gy). Index lesion volume increase between baseline CT and SPECT/ceCT was 14% (95% LoA: -55.9%, 82.9%). Index lesion dose ( p = 0.01) and volume ( p = 0.01) differed significantly between workflows. The median time interval between baseline imaging and SPECT/ceCT was 6 weeks (IQR: 3.7 to 9.3 weeks). The median deviation of the index lesion between the baseline diagnostic image and hybrid SPECT/ceCT image was 4.9 ± 2.2 mm and there was an average DICE score of 0.6 ± 0.2. Conclusion: Hybrid [99mTc]Tc-MAA SPECT/ceCT treatment planning is technically feasible and leads to significant differences in dosimetry metrics compared with the conventional method.
- Open Access
- 12 May 2026
- Published by MDPI AG in Current Oncology
- Vol. 33 (5) , 285
Radioembolization Practice in North America Versus Europe: Results from a Global Survey
Purpose: The Cardiovascular and Interventional Radiological Society of Europe (CIRSE) conducted an international survey on the real-life application of transarterial radioembolization (TARE). This sub-analysis of the complete survey evaluates intercontinental disparities in TARE practices. Materials and Methods: A survey of 32 multiple-choice questions was distributed to CIRSE members between November and December 2022. The questions addressed steps of the TARE workflow, including treatment work-up, planning and dosimetry, intervention, follow-up and innovations. Responses were curated to remove duplicates and incomplete entries and categorised into continental groups. Analysis focused on variations between Europe and North America and impacting factors in the respective regions were identified. Data is presented using descriptive statistics. Results: Responses were obtained from 30 countries and 133 hospitals, including 87 European and 21 North American centres. Hepatocellular carcinoma was the most common indication, constituting 61% of treatments in North America and 51% in Europe. North America predominantly used 90Y glass microspheres, whereas Europe used 90Y resin. Procedural differences included the adoption of intra-procedural CT imaging, utilized by all North American sites, versus 89% of European sites. Outpatient treatments were favoured in North America (85%), while in Europe, most patients remained hospitalized for one night (51%). Both regions increasingly emphasized dosimetry-guided treatments, with personalized dosimetry planning in 71% and 84% of North American and European sites, respectively. Conclusions: This North America–Europe comparison highlights regional differences in radioembolization practice between the leading continents in procedure volume, based on results of the CIRSE TARE survey. Specific intercontinental differences identified in this survey included hospitalization, product utilization, and procedural techniques.
- 12 May 2026
- Published by MDPI AG in Current Oncology
- Vol. 33 (5) , 285
Open AccessRadioembolization Practice in North America Versus Europe: Results from a Global Survey
Purpose: The Cardiovascular and Interventional Radiological Society of Europe (CIRSE) conducted an international survey on the real-life application of transarterial radioembolization (TARE). This sub-analysis of the complete survey evaluates intercontinental disparities in TARE practices. Materials and Methods: A survey of 32 multiple-choice questions was distributed to CIRSE members between November and December 2022. The questions addressed steps of the TARE workflow, including treatment work-up, planning and dosimetry, intervention, follow-up and innovations. Responses were curated to remove duplicates and incomplete entries and categorised into continental groups. Analysis focused on variations between Europe and North America and impacting factors in the respective regions were identified. Data is presented using descriptive statistics. Results: Responses were obtained from 30 countries and 133 hospitals, including 87 European and 21 North American centres. Hepatocellular carcinoma was the most common indication, constituting 61% of treatments in North America and 51% in Europe. North America predominantly used 90Y glass microspheres, whereas Europe used 90Y resin. Procedural differences included the adoption of intra-procedural CT imaging, utilized by all North American sites, versus 89% of European sites. Outpatient treatments were favoured in North America (85%), while in Europe, most patients remained hospitalized for one night (51%). Both regions increasingly emphasized dosimetry-guided treatments, with personalized dosimetry planning in 71% and 84% of North American and European sites, respectively. Conclusions: This North America–Europe comparison highlights regional differences in radioembolization practice between the leading continents in procedure volume, based on results of the CIRSE TARE survey. Specific intercontinental differences identified in this survey included hospitalization, product utilization, and procedural techniques.
- Open Access
- 26 November 2024
- Published by MDPI AG in Current Oncology
- Vol. 31 (12) , 7511-7522
An Evaluation of 90Y Bremsstrahlung SPECT Image Quality in the Presence of 99mTc: A Technical Perspective on Same-Day Radioembolization
In same-day radioembolization, 99mTc-MAA SPECT/CT, 90Y radioembolization, and post-treatment 90Y SPECT/CT procedures are conducted on the same-day, resulting in a dual-isotope environment of 90Y and 99mTc during post-treatment imaging. This study aimed to quantify the impact of 99mTc on 90Y bremsstrahlung-SPECT/CT image quality and to establish an optimised imaging protocol for both clinical practice, and with advanced reconstruction techniques. Utilising a NEMA IQ phantom, contrast recovery coefficients (CRCs) were measured to evaluate the 90Y image quality degradation caused by 99mTc. SPECT/CT scans of 90Y-only and 90Y with varying amounts of 99mTc were conducted using a standard protocol (90–120 keV energy window, high-energy collimator) and various dual-isotope protocols. The standard protocol resulted in a marked CRC reduction, with the largest sphere’s CRC decreasing from 0.21 (90Y-only) to 0.05 when 99mTc activity was 5% of 90Y. For an optimised protocol (160–200 keV energy window, high-energy collimator) CRC values were 0.16 for 90Y-only and 0.15 for 90Y+99mTc. The highest CRC values were achieved with an advanced Monte Carlo-based reconstruction, showing 0.58 for 90Y-only and 0.46 for 90Y+99mTc. Image quality degradation was noted in dual-isotope settings even when using an optimised protocol. Advanced reconstruction techniques markedly improved post-treatment image quality.
- 26 November 2024
- Published by MDPI AG in Current Oncology
- Vol. 31 (12) , 7511-7522
Open AccessAn Evaluation of 90Y Bremsstrahlung SPECT Image Quality in the Presence of 99mTc: A Technical Perspective on Same-Day Radioembolization
In same-day radioembolization, 99mTc-MAA SPECT/CT, 90Y radioembolization, and post-treatment 90Y SPECT/CT procedures are conducted on the same-day, resulting in a dual-isotope environment of 90Y and 99mTc during post-treatment imaging. This study aimed to quantify the impact of 99mTc on 90Y bremsstrahlung-SPECT/CT image quality and to establish an optimised imaging protocol for both clinical practice, and with advanced reconstruction techniques. Utilising a NEMA IQ phantom, contrast recovery coefficients (CRCs) were measured to evaluate the 90Y image quality degradation caused by 99mTc. SPECT/CT scans of 90Y-only and 90Y with varying amounts of 99mTc were conducted using a standard protocol (90–120 keV energy window, high-energy collimator) and various dual-isotope protocols. The standard protocol resulted in a marked CRC reduction, with the largest sphere’s CRC decreasing from 0.21 (90Y-only) to 0.05 when 99mTc activity was 5% of 90Y. For an optimised protocol (160–200 keV energy window, high-energy collimator) CRC values were 0.16 for 90Y-only and 0.15 for 90Y+99mTc. The highest CRC values were achieved with an advanced Monte Carlo-based reconstruction, showing 0.58 for 90Y-only and 0.46 for 90Y+99mTc. Image quality degradation was noted in dual-isotope settings even when using an optimised protocol. Advanced reconstruction techniques markedly improved post-treatment image quality.
- Open Access
- 24 June 2024
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 47 (9) , 1224-1236
Transarterial Radioembolization (TARE) Global Practice Patterns: An International Survey by the Cardiovascular and Interventional Radiology Society of Europe (CIRSE)
Purpose: An international survey was conducted by the Cardiovascular Interventional Radiological Society of Europe (CIRSE) to evaluate radioembolization practice and capture opinions on real-world clinical and technical aspects of this therapy. Materials and Methods: A survey with 32 multiple choice questions was sent as an email to CIRSE members between November and December 2022. CIRSE group member and sister societies promoted the survey to their local members. The dataset was cleaned of duplicates and entries with missing data, and the resulting anonymized dataset was analysed. Data were presented using descriptive statistics. Results: The survey was completed by 133 sites, from 30 countries, spanning 6 continents. Most responses were from European centres (87/133, 65%), followed by centres from the Americas (22/133, 17%). Responding sites had been performing radioembolization for 10 years on average and had completed a total of 20,140 procedures over the last 5 years. Hepatocellular carcinoma treatments constituted 56% of this total, colorectal liver metastasis 17% and cholangiocarcinoma 14%. New sites had opened every year for the past 20 years, indicating the high demand for this therapy. Results showed a trend towards individualized treatment, with 79% of responders reporting use of personalized dosimetry for treatment planning and 97% reporting routine assessment of microsphere distribution post-treatment. Interventional radiologists played an important role in referrals, being present in the referring multi-disciplinary team in 91% of responding centres. Conclusion: This survey provides insight into the current state of radioembolization practice globally. The results reveal the increasing significance placed on dosimetry, evolving interventional techniques and increased technology integration. Graphical
- 24 June 2024
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 47 (9) , 1224-1236
Open AccessTransarterial Radioembolization (TARE) Global Practice Patterns: An International Survey by the Cardiovascular and Interventional Radiology Society of Europe (CIRSE)
Purpose: An international survey was conducted by the Cardiovascular Interventional Radiological Society of Europe (CIRSE) to evaluate radioembolization practice and capture opinions on real-world clinical and technical aspects of this therapy. Materials and Methods: A survey with 32 multiple choice questions was sent as an email to CIRSE members between November and December 2022. CIRSE group member and sister societies promoted the survey to their local members. The dataset was cleaned of duplicates and entries with missing data, and the resulting anonymized dataset was analysed. Data were presented using descriptive statistics. Results: The survey was completed by 133 sites, from 30 countries, spanning 6 continents. Most responses were from European centres (87/133, 65%), followed by centres from the Americas (22/133, 17%). Responding sites had been performing radioembolization for 10 years on average and had completed a total of 20,140 procedures over the last 5 years. Hepatocellular carcinoma treatments constituted 56% of this total, colorectal liver metastasis 17% and cholangiocarcinoma 14%. New sites had opened every year for the past 20 years, indicating the high demand for this therapy. Results showed a trend towards individualized treatment, with 79% of responders reporting use of personalized dosimetry for treatment planning and 97% reporting routine assessment of microsphere distribution post-treatment. Interventional radiologists played an important role in referrals, being present in the referring multi-disciplinary team in 91% of responding centres. Conclusion: This survey provides insight into the current state of radioembolization practice globally. The results reveal the increasing significance placed on dosimetry, evolving interventional techniques and increased technology integration. Graphical
- Open Access
- 29 May 2024
- Published by Springer Nature in EJNMMI Physics
- Vol. 11 (1) , 1-18
An international phantom study of inter-site variability in Technetium-99m image quantification: analyses from the TARGET radioembolization study
Background: Personalised multi-compartment dosimetry based on [99mTc]Tc-MAA is a valuable tool for planning 90Y radioembolization treatments. The establishment and effective application of dose–effect relationships in yttrium-90 (90Y) radioembolization requires [99mTc]Tc-MAA SPECT quantification ideally independent of clinical site. The purpose of this multi-centre phantom study was to evaluate inter-site variability of [99mTc]Tc-MAA imaging and evaluate a standardised imaging protocol. Data was obtained from the TARGET study, an international, retrospective multi-centre study including 14 sites across 8 countries. The impact of imaging related factors was estimated using a NEMA IQ phantom (representing the liver), and a uniformly filled cylindrical phantom (representing the lungs). Imaging was performed using site-specific protocols and a standardized protocol. In addition, the impact of implementing key image corrections (scatter and attenuation correction) in the site-specific protocols was investigated. Inter-site dosimetry accuracy was evaluated by comparing computed Lung Shunt Fraction (LSF) measured using planar imaging of the cylindrical and NEMA phantom, and contrast recovery coefficient (CRC) measured using SPECT imaging of the NEMA IQ phantom. Results: Regarding the LSF, inter-site variation with planar site-specific protocols was minimal, as determined by comparing computed LSF between sites (interquartile range 9.6–10.1%). A standardised protocol did not improve variation (interquartile range 8.4–9.0%) but did improve mean accuracy compared to the site-specific protocols (5.0% error for standardised protocol vs 8.8% error for site-specific protocols). Regarding the CRC, inter-system variation was notable for site-specific SPECT protocols and could not be improved by the standardised protocol (CRC interquartile range for 37 mm sphere 0.5–0.7 and 0.6–0.8 respectively), however the standardised protocol did improve accuracy of sphere:background determination. Implementation of key image corrections did improve inter-site variation (CRC interquartile range for 37 mm sphere 0.6–0.7). Conclusion: Eliminating sources of variability in image corrections between imaging protocols reduces inter-site variation in quantification. A standardised protocol was not able to improve consistency of LSF or CRC but was able to improve accuracy.
- 29 May 2024
- Published by Springer Nature in EJNMMI Physics
- Vol. 11 (1) , 1-18
Open AccessAn international phantom study of inter-site variability in Technetium-99m image quantification: analyses from the TARGET radioembolization study
Background: Personalised multi-compartment dosimetry based on [99mTc]Tc-MAA is a valuable tool for planning 90Y radioembolization treatments. The establishment and effective application of dose–effect relationships in yttrium-90 (90Y) radioembolization requires [99mTc]Tc-MAA SPECT quantification ideally independent of clinical site. The purpose of this multi-centre phantom study was to evaluate inter-site variability of [99mTc]Tc-MAA imaging and evaluate a standardised imaging protocol. Data was obtained from the TARGET study, an international, retrospective multi-centre study including 14 sites across 8 countries. The impact of imaging related factors was estimated using a NEMA IQ phantom (representing the liver), and a uniformly filled cylindrical phantom (representing the lungs). Imaging was performed using site-specific protocols and a standardized protocol. In addition, the impact of implementing key image corrections (scatter and attenuation correction) in the site-specific protocols was investigated. Inter-site dosimetry accuracy was evaluated by comparing computed Lung Shunt Fraction (LSF) measured using planar imaging of the cylindrical and NEMA phantom, and contrast recovery coefficient (CRC) measured using SPECT imaging of the NEMA IQ phantom. Results: Regarding the LSF, inter-site variation with planar site-specific protocols was minimal, as determined by comparing computed LSF between sites (interquartile range 9.6–10.1%). A standardised protocol did not improve variation (interquartile range 8.4–9.0%) but did improve mean accuracy compared to the site-specific protocols (5.0% error for standardised protocol vs 8.8% error for site-specific protocols). Regarding the CRC, inter-system variation was notable for site-specific SPECT protocols and could not be improved by the standardised protocol (CRC interquartile range for 37 mm sphere 0.5–0.7 and 0.6–0.8 respectively), however the standardised protocol did improve accuracy of sphere:background determination. Implementation of key image corrections did improve inter-site variation (CRC interquartile range for 37 mm sphere 0.6–0.7). Conclusion: Eliminating sources of variability in image corrections between imaging protocols reduces inter-site variation in quantification. A standardised protocol was not able to improve consistency of LSF or CRC but was able to improve accuracy.
- Open Access
- 1 November 2023
- Published by KEAI Publishing in Journal of Interventional Medicine
- Vol. 6 (4) , 153-159
Current status of yttrium-90 microspheres radioembolization in primary and metastatic liver cancer
Liver malignancy, including primary liver cancer and metastatic liver cancer, has become one of the most common causes of cancer-related death worldwide due to the high malignant degree and limited systematic treatment strategy. Radioembolization with yttrium-90 (90Y)-loaded microspheres is a relatively novel technology that has made significant progress in the local treatment of liver malignancy. The different steps in the extensive work-up of radioembolization for patients with an indication for treatment with 90Y microspheres, from patient selection to follow up, both technically and clinically, are discussed in this paper. It describes the application and development of 90Y microspheres in the treatment of liver cancer.
- 1 November 2023
- Published by KEAI Publishing in Journal of Interventional Medicine
- Vol. 6 (4) , 153-159
Open AccessCurrent status of yttrium-90 microspheres radioembolization in primary and metastatic liver cancer
Liver malignancy, including primary liver cancer and metastatic liver cancer, has become one of the most common causes of cancer-related death worldwide due to the high malignant degree and limited systematic treatment strategy. Radioembolization with yttrium-90 (90Y)-loaded microspheres is a relatively novel technology that has made significant progress in the local treatment of liver malignancy. The different steps in the extensive work-up of radioembolization for patients with an indication for treatment with 90Y microspheres, from patient selection to follow up, both technically and clinically, are discussed in this paper. It describes the application and development of 90Y microspheres in the treatment of liver cancer.
- 24 November 2021
- Published by Georg Thieme Verlag KG in Seminars in Interventional Radiology
- Vol. 38 (05) , 542-553
Beyond the MAA-Y90 Paradigm: The Evolution of Radioembolization Dosimetry Approaches and Scout Particles
Radioembolization is a well-established treatment for primary and metastatic liver cancer. There is increasing interest in personalized treatment planning supported by dosimetry, as it provides an opportunity to optimize dose delivery to tumor and minimize nontarget deposition, which demonstrably increases the efficacy and safety of this therapy. However, the optimal dosimetry procedure in the radioembolization setting is still evolving; existing data are limited as few trials have prospectively tailored dose based on personalized planning and predominantly semi-empirical methods are used for dose calculation. Since the pretreatment or “scout” procedure forms the basis of dosimetry calculations, an accurate and reliable technique is essential. 99mTc-MAA SPECT constitutes the current accepted standard for pretreatment imaging; however, inconsistent patterns in published data raise the question whether this is the optimal agent. Alternative particles are now being introduced to the market, and early indications suggest use of an identical scout and treatment particle may be superior to the current standard. This review will undertake an evaluation of the increasingly refined dosimetric methods driving radioembolization practices, and a horizon scanning exercise identifying alternative scout particle solutions. Together these constitute a compelling vision for future treatment planning methods that prioritize individualized care. Publication Date: 24 November 2021 (online) © 2021. Thieme. All rights reserved. Thieme Medical Publishers, Inc. 333 Seventh Avenue, 18th Floor, New York, NY 10001, USA
- 24 November 2021
- Published by Georg Thieme Verlag KG in Seminars in Interventional Radiology
- Vol. 38 (05) , 542-553
Beyond the MAA-Y90 Paradigm: The Evolution of Radioembolization Dosimetry Approaches and Scout Particles
Radioembolization is a well-established treatment for primary and metastatic liver cancer. There is increasing interest in personalized treatment planning supported by dosimetry, as it provides an opportunity to optimize dose delivery to tumor and minimize nontarget deposition, which demonstrably increases the efficacy and safety of this therapy. However, the optimal dosimetry procedure in the radioembolization setting is still evolving; existing data are limited as few trials have prospectively tailored dose based on personalized planning and predominantly semi-empirical methods are used for dose calculation. Since the pretreatment or “scout” procedure forms the basis of dosimetry calculations, an accurate and reliable technique is essential. 99mTc-MAA SPECT constitutes the current accepted standard for pretreatment imaging; however, inconsistent patterns in published data raise the question whether this is the optimal agent. Alternative particles are now being introduced to the market, and early indications suggest use of an identical scout and treatment particle may be superior to the current standard. This review will undertake an evaluation of the increasingly refined dosimetric methods driving radioembolization practices, and a horizon scanning exercise identifying alternative scout particle solutions. Together these constitute a compelling vision for future treatment planning methods that prioritize individualized care. Publication Date: 24 November 2021 (online) © 2021. Thieme. All rights reserved. Thieme Medical Publishers, Inc. 333 Seventh Avenue, 18th Floor, New York, NY 10001, USA