Sheikh Safiullah
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sheikh Safiullah has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Asadur Rahman
National Institute of Technology
6 shared publications Shameem Ahmad Lone
4 shared publications- S. M. Suhail Hussain
Electrical Engineering Department, KFUPM, Dhahran, Saudi Arabia
3 shared publications - Shameem Ahmad Lone
National Institute of Technology Srinagar
2 shared publications - Taha Selim Ustun
Fukushima Renewable Energy Institute, AIST, Koriyama, Japan
2 shared publications - Asadur Rahman
Electrical Engineering Department National Institute of Technology Srinagar Srinagar India
1 shared publication
Latest Publications
- Open Access
- 1 November 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (21) , 14287
Novel COVID-19 Based Optimization Algorithm (C-19BOA) for Performance Improvement of Power Systems
The ongoing pandemic due to novel coronavirus disease-2019 (COVID-19) has rapidly unsettled the health sector with a considerable fatality rate. The main factors that help minimize the spread of this deadly virus are the proper use of masks, social distancing and antibody growth rate in a person. Based on these factors, we propose a new nature-inspired meta-heuristic algorithm named COVID-19 Based Optimization Algorithm (C-19BOA). The proposed C-19BOA mimics the spread and control behavior of coronavirus disease centered on three containment factors: (1) social distancing, (2) use of masks, and (3) antibody rate. Initially, the mathematical models of containment factors are presented, and further, the proposed C-19BOA is developed. To ascertain the effectiveness of the developed C-19BOA, its performance is verified on standard IEEE mathematical benchmark functions for the minimization of these benchmark functions and convergence to the optimal values. These performances are compared with established bio-inspired optimization algorithms available in the literature. Finally, the developed C-19BOA is applied on an electrical power system load–frequency–control model to test its effectiveness in optimizing the power system parameters and to check its applicability in solving modern engineering problems. A performance comparison of the proposed C-19BOA and other optimization algorithms is validated based on optimizing the controller gains for reducing the steady-state errors by comparing the effective frequency and tie-line power regulation ability of an industrially applied Proportional–Integral–Derivative controller (PID) and Active Disturbance Rejection controller (ADRC). Moreover, the robustness of C-19BOA optimized PID and ADRC gains is tested by varying the system parameters from their nominal values.
- 1 November 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (21) , 14287
Open AccessNovel COVID-19 Based Optimization Algorithm (C-19BOA) for Performance Improvement of Power Systems
The ongoing pandemic due to novel coronavirus disease-2019 (COVID-19) has rapidly unsettled the health sector with a considerable fatality rate. The main factors that help minimize the spread of this deadly virus are the proper use of masks, social distancing and antibody growth rate in a person. Based on these factors, we propose a new nature-inspired meta-heuristic algorithm named COVID-19 Based Optimization Algorithm (C-19BOA). The proposed C-19BOA mimics the spread and control behavior of coronavirus disease centered on three containment factors: (1) social distancing, (2) use of masks, and (3) antibody rate. Initially, the mathematical models of containment factors are presented, and further, the proposed C-19BOA is developed. To ascertain the effectiveness of the developed C-19BOA, its performance is verified on standard IEEE mathematical benchmark functions for the minimization of these benchmark functions and convergence to the optimal values. These performances are compared with established bio-inspired optimization algorithms available in the literature. Finally, the developed C-19BOA is applied on an electrical power system load–frequency–control model to test its effectiveness in optimizing the power system parameters and to check its applicability in solving modern engineering problems. A performance comparison of the proposed C-19BOA and other optimization algorithms is validated based on optimizing the controller gains for reducing the steady-state errors by comparing the effective frequency and tie-line power regulation ability of an industrially applied Proportional–Integral–Derivative controller (PID) and Active Disturbance Rejection controller (ADRC). Moreover, the robustness of C-19BOA optimized PID and ADRC gains is tested by varying the system parameters from their nominal values.
- Open Access
- 17 October 2022
- Published by MDPI AG in World Electric Vehicle Journal
- Vol. 13 (10) , 192
Evaluating the Optimal Electric Vehicle Location for a Hybrid Energy System Controlled with Novel Active Disturbance Rejection Controller
Power system control is an important issue with regard to power system safety, flexibility, and reliability. Over the years, various new power system control strategies have been explored, but the main disadvantage of these control strategies is their complexity in structures with respect to industrially applied PID controller. The present paper introduces a novel control strategy based on modified disturbance rejection control, which is a modification of the PID controller that not only preserves the simplicity of control design but also offers an effective control based on state observer-based control law. The proposed control strategy addresses some basic limitations of a PID controller and implements modified control law to remove these limitations. In order to prove the effective control of the proposed control strategy, a standard IEEE-39 bus power system integrated with renewable energy generations is developed, and a comparative analysis of the proposed controller is performed with respect to its ancestor controllers. The comparison is validated based on the system dynamic responses like frequency and tie-line power deviations when the power system is subjected to different disturbances. Furthermore, the power system is integrated with electric vehices (EVs) in vehicle-to-grid (V2G) mode in order to ascertain the effect of EVs when used in V2G mode. A novel study is carried out in which the optimal location of EVs in the power system is determined based on the enhancement in stability of the power system by EVs. The analyses are carried out in MATLAB Simulink software. Simulation reports reflect the optimal control action of the proposed controller with respect to already established strategies projected in the literature. Moreover, the results illustrate that EVs when connected in Area 1 and Area 3 of the power system, the system deviations and steady-state errors are much less as compared to the other cases.
- 17 October 2022
- Published by MDPI AG in World Electric Vehicle Journal
- Vol. 13 (10) , 192
Open AccessEvaluating the Optimal Electric Vehicle Location for a Hybrid Energy System Controlled with Novel Active Disturbance Rejection Controller
Power system control is an important issue with regard to power system safety, flexibility, and reliability. Over the years, various new power system control strategies have been explored, but the main disadvantage of these control strategies is their complexity in structures with respect to industrially applied PID controller. The present paper introduces a novel control strategy based on modified disturbance rejection control, which is a modification of the PID controller that not only preserves the simplicity of control design but also offers an effective control based on state observer-based control law. The proposed control strategy addresses some basic limitations of a PID controller and implements modified control law to remove these limitations. In order to prove the effective control of the proposed control strategy, a standard IEEE-39 bus power system integrated with renewable energy generations is developed, and a comparative analysis of the proposed controller is performed with respect to its ancestor controllers. The comparison is validated based on the system dynamic responses like frequency and tie-line power deviations when the power system is subjected to different disturbances. Furthermore, the power system is integrated with electric vehices (EVs) in vehicle-to-grid (V2G) mode in order to ascertain the effect of EVs when used in V2G mode. A novel study is carried out in which the optimal location of EVs in the power system is determined based on the enhancement in stability of the power system by EVs. The analyses are carried out in MATLAB Simulink software. Simulation reports reflect the optimal control action of the proposed controller with respect to already established strategies projected in the literature. Moreover, the results illustrate that EVs when connected in Area 1 and Area 3 of the power system, the system deviations and steady-state errors are much less as compared to the other cases.
- Open Access
- 26 September 2022
- Published by Elsevier in Energy Reports
- Vol. 8, 12186-12202
Robust frequency–voltage stabilization scheme for multi-area power systems incorporated with EVs and renewable generations using AI based modified disturbance rejection controller
- 26 September 2022
- Published by Elsevier in Energy Reports
- Vol. 8, 12186-12202
Open AccessRobust frequency–voltage stabilization scheme for multi-area power systems incorporated with EVs and renewable generations using AI based modified disturbance rejection controller
- 18 September 2022
- Published by Taylor & Francis in IETE Journal of Research
- Vol. 70 (1) , 515-530
A Second-order ADRC for Synchronized Frequency-Voltage Mitigation of EV Integrated Power System
The present paper proposes a novel disturbance rejection-based scheme applied to a power system for concurrent control of system voltage, frequency, and tie-line power. The generating units in the power system comprise varied generating sources, such as thermal, diesel, solar-thermal, and wind sources. Owing to the present rigid limitations on energy assets and environmental alarms, electric vehicles are integrated with the power system in both areas. The complex power system needs a robust controller for stable operation. In response to this challenge, a novel second-order Active Disturbance-Rejection-Control (ADRC) is modeled as a secondary controller for performance studies. An extended state observer is designed for the estimation of system disturbance and uncertainties assisting ADRC in compensating for the impact through disturbance rejection. The magnetotactic bacteria-optimization approach is utilized to optimize the controller gains by reducing the errors in the objective function. Detailed case studies are carried out on two-area and three-area hybrid power-system incorporating different renewable energy plants to test the performance of the proposed controller. The dominance of the developed second-order-ADRC is verified based on system performance improvement concerning testified controllers available in the literature. The developed second-order-ADRC validates the robustness under different system-changed conditions. The fact that electric vehicles assist in system dynamic regulation is studied thoroughly.
- 18 September 2022
- Published by Taylor & Francis in IETE Journal of Research
- Vol. 70 (1) , 515-530
A Second-order ADRC for Synchronized Frequency-Voltage Mitigation of EV Integrated Power System
The present paper proposes a novel disturbance rejection-based scheme applied to a power system for concurrent control of system voltage, frequency, and tie-line power. The generating units in the power system comprise varied generating sources, such as thermal, diesel, solar-thermal, and wind sources. Owing to the present rigid limitations on energy assets and environmental alarms, electric vehicles are integrated with the power system in both areas. The complex power system needs a robust controller for stable operation. In response to this challenge, a novel second-order Active Disturbance-Rejection-Control (ADRC) is modeled as a secondary controller for performance studies. An extended state observer is designed for the estimation of system disturbance and uncertainties assisting ADRC in compensating for the impact through disturbance rejection. The magnetotactic bacteria-optimization approach is utilized to optimize the controller gains by reducing the errors in the objective function. Detailed case studies are carried out on two-area and three-area hybrid power-system incorporating different renewable energy plants to test the performance of the proposed controller. The dominance of the developed second-order-ADRC is verified based on system performance improvement concerning testified controllers available in the literature. The developed second-order-ADRC validates the robustness under different system-changed conditions. The fact that electric vehicles assist in system dynamic regulation is studied thoroughly.
- 25 November 2021
- Published by Wiley in Optimal Control Applications and Methods
- Vol. 44 (2) , 905-934
Optimal control of electrical vehicle incorporated hybrid power system with second order fractional‐active disturbance rejection controller
This article proposes a novel control methodology employing a fractional‐active‐disturbance‐rejection‐controller for the combined operation of load frequency control and automatic voltage regulator of a hybrid power system. A two area hybrid power system with diverse energy sources like solar‐thermal, conventional‐thermal and wind sources equipped with appropriate system nonlinearities is investigated. In order to ascertain the role of modern‐day electric‐vehicle (EV), the hybrid power system is incorporated with EVs in both the areas. To establish an effective frequency, voltage and tie line power control of the hybrid power system, a second order fractional‐active‐disturbance‐rejection‐controller with fractional‐extended state observer is modeled as secondary controller. Magnetotactic‐bacteria‐optimization (MBO) technique is applied to obtain optimal values of the controller gains and the hybrid system parameters. The robustness of the controller gains is tested under different system parameter changes from their nominal values. In addition, the effect of incorporating a power system stabilizer on the hybrid power system is evaluated. Further, the impact of integrating renewable sources and EVs in the hybrid power system is explored. Moreover, the stability of the hybrid power system is monitored with the inclusion of FACTS device. The developed controller operates encouragingly with reference to system stability, rapidity and accuracy in comparison to testified control strategies available in the literature. The robustness test under load‐perturbation, solar‐insolation, wind input variations also proves the efficiency of MBO optimized second order fractional‐active‐disturbance‐rejection‐controller gains.
- 25 November 2021
- Published by Wiley in Optimal Control Applications and Methods
- Vol. 44 (2) , 905-934
Optimal control of electrical vehicle incorporated hybrid power system with second order fractional‐active disturbance rejection controller
This article proposes a novel control methodology employing a fractional‐active‐disturbance‐rejection‐controller for the combined operation of load frequency control and automatic voltage regulator of a hybrid power system. A two area hybrid power system with diverse energy sources like solar‐thermal, conventional‐thermal and wind sources equipped with appropriate system nonlinearities is investigated. In order to ascertain the role of modern‐day electric‐vehicle (EV), the hybrid power system is incorporated with EVs in both the areas. To establish an effective frequency, voltage and tie line power control of the hybrid power system, a second order fractional‐active‐disturbance‐rejection‐controller with fractional‐extended state observer is modeled as secondary controller. Magnetotactic‐bacteria‐optimization (MBO) technique is applied to obtain optimal values of the controller gains and the hybrid system parameters. The robustness of the controller gains is tested under different system parameter changes from their nominal values. In addition, the effect of incorporating a power system stabilizer on the hybrid power system is evaluated. Further, the impact of integrating renewable sources and EVs in the hybrid power system is explored. Moreover, the stability of the hybrid power system is monitored with the inclusion of FACTS device. The developed controller operates encouragingly with reference to system stability, rapidity and accuracy in comparison to testified control strategies available in the literature. The robustness test under load‐perturbation, solar‐insolation, wind input variations also proves the efficiency of MBO optimized second order fractional‐active‐disturbance‐rejection‐controller gains.
- 11 October 2021
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 31 (11) , e13083
State‐observerbasedIDDcontroller for concurrentfrequency‐voltagecontrol of a hybrid power system with electric vehicle uncertainties
- 11 October 2021
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 31 (11) , e13083
State‐observerbasedIDDcontroller for concurrentfrequency‐voltagecontrol of a hybrid power system with electric vehicle uncertainties