JLJean-Pierre Likforman

Jean-Pierre Likforman

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jean-Pierre Likforman has a total of 111 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Incoherent repumping scheme in the Sr + 88 five-level manifold

    by Valentin Martimort, Sacha Guesne, Derwell Drapier, Vincent Tugayé, Lilay Gros-Desormeaux, Valentin Cambier, Albane Douillet, Luca Guidoni, Jean-Pierre Likforman

  • Open Access

    Next-Value Prediction of Beam Waists From Mixed Pitch Grating Using Simplified Transformer Model

    by Yu Dian Lim, Peng Zhao, Luca Guidoni, Jean-Pierre Likforman, Chuan Seng Tan

    In this study, a simplified transformer model is used to predict the beam waist of 1,092 nm light coupled out from SiN-based mixed pitch gratings at various heights. The beam waists data at various heights above the grating is first compiled. Then, we used a sequence of the current beam waist values, z-positions, and the computed mathematical indicators (features) to predict the next beam waist value (labels). Optimized transformer model yields average percentage error (APE) of 6.6% between the predicted and actual beam waists, which corresponds to 93.4% prediction accuracy. This study provides a pioneering approach to using natural language processing model to perform predictive modelling on photonics data, and possible extrapolation of photonics data using transformer model.


  • Predictive Modelling of Optical Beams From Grating Structure Using Deep Neural Network

    by Yu Dian Lim, Peng Zhao, Luca Guidoni, Jean-Pierre Likforman, Chuan Seng Tan

    Integrated grating structure has been widely used in the optical addressing of trapped ion qubits in quantum computing. For accurate optical addressing, the optical properties of light beam coupled out from the grating should be thoroughly understood. In this study, deep neural network (DNN) modeling is used to predict the optical properties of light from silicon nitride (SiN) grating. DNN models with various number of layers (L) and nodes per layer (N) are attempted and optimized. Both overfitted and well-fitted L/N combinations are addressed. The APE values of the overfitted DNNs can reach as low as 5.2%, while the APE values of the well-fitted DNN reaches as low as 7.2%.


  • Simplified Assembly of Through-Silicon-Via Integrated Ion Traps

    by Peng Zhao, Hong Yu Li, Jean-Pierre Likforman, Theo Henner, Yu Dian Lim, Liang Xing Hu, Wen Wei Seit, Guidoni Luca, Chuan Seng Tan

    The scalability of surface electrode ion traps has been progressively improved with the on-chip integration of conventionally bulk components. Based on the development of through silicon via (TSV) integrated ion trap, in this work, we further simplify the back-end assembly process by patterning a redistribution layer (RDL) onto customized ceramic pin grid array (CPGA) package. This RDL has internal connection with CPGA pin on the back side, rerouting the electrical signal and facilitating the direct bonding of TSV trap and CPGA. The patterned neighboring RDL has an averaged resistance of 4.5 × 10 12 Ω, three orders of magnitude higher than that of TSV trap itself. As compared to the previous assembly (glass interposer wire bonded to a conventional CPGA), a small parasitic capacitance increase of 0.1 pF of the customized CPGA is observed. Radio frequency (RF) electrical tests indicate that the trap on customized CPGA will not induce additional power loss. Meanwhile, due to the high thermal conductivity of ceramic materials, the heat dissipation capability of customized CPGA is boosted. The functionality of TSV trap on customized CPGA is also demonstrated by trapping and laser cooling the 88 Sr + ions. The measured heating rate (21 quanta per millisecond for an axial frequency of 300 kHz) is comparable with the trap assembled in previous approach. This indicates that the CPGA with built-in RDL is fully compatible with ion trapping applications, providing a new approach towards compact, flexible, and robust ion trap assembly.


  • Development of Nitride-Based Optical Phased Array at 1092 nm for the Optical Addressing of 88Sr+ Ion

    by Yu Dian Lim, Simon Goh Chun Kiat, Wen Wei Seit, Peng Zhao, Luca Guidoni, Jean-Pierre Likforman, Chuan Seng Tan

    Optical phased array (OPA) structures are designed and fabricated for the optical addressing of trapped 88 Sr + ions. Laser light of 1092 nm wavelength corresponding to the $^{2}\text{D}_{3/2}$ to $^{2}\text{P}_{1/2}$ of 88 Sr + ion is used, where silicon nitride (SiN) platform with integrated titanium nitride (TiN) thermos-optic heaters are selected. Beam steering of $\sim 33~\mu \text{m}$ , which corresponds to ~11.6° steering angle, is obtained by applying 10V on alternative TiN heaters in the 8-Channel OPA structure.


  • Open Access

    Development of Grating for the Optical Addressing of Sr+ Ions With Data Analysis Techniques

    by Yu Dian Lim, Peng Zhao, Luca Guidoni, Jean-Pierre Likforman, Chuan Seng Tan

    In this study, SiN-based gratings with various radius of curvature ( r ) are designed and fabricated for the optical addressing of trapped Sr + ion. The beam width of the light coupled out from the gratings is investigated using a self-developed Python-based data analysis technique. It is found that the r values have insignificant influence on the beam width along x -axis; whereas the beam waist along y -axis reduces from 13.96 to 12.3 μm as r increases from 15 to 20 μm, then increases gradually to 20.51 μm as the r value further increases to 60 μm. The obtained results can provide a versatile solution on the optical addressing of trapped Sr + for applications in quantum engineering.


  • RF Performance Benchmarking of TSV Integrated Surface Electrode Ion Trap for Quantum Computing

    by Peng Zhao, Hong Yu Li, Jing Tao, Jean-Pierre Likforman, Yu Dian Lim, Wen Wei Seit, Luca Guidoni, Chuan Seng Tan

    Surface electrode ion trap is highly promising for practical quantum computing due to its superior controllability on the trapped ions. With advanced microfabrication techniques, silicon has been developed as an ion trap substrate for delicate surface electrodes design and monolithic electro-optical components integration. However, the high RF loss of silicon hinders the possible large-scale implementation. In this work, we demonstrate a through silicon via (TSV) integrated ion trap, which has low RF loss due to the elimination of wire bonding (WB) pads on the surface and the miniaturization of form factor. We also fabricate two types of conventional WB traps with or without a grounding screen layer. The RF performances of different ion traps are tested and compared, in terms of on-chip S-parameter, postpackaging resonance, and resulting power loss. The results show that the TSV trap has low S21 (~0.2 dB at 50 MHz), high $Q$ factor (~22), and low power loss (0.26 W) compared to WB traps. In addition, 3-D finite element modeling (FEM) is employed for electric field visualization and RF loss analysis of different traps. The extracted results from the modeling show a decent agreement with the measurements. In addition to various RF tests, the design, fabrication, and ion trapping operation of different ion traps are presented. This work provides insights into RF loss of ion trapping devices and offers a new solution for RF loss reduction.


  • Absolute single-ion thermometry

    by Vincent Tugayé, Jean-Pierre Likforman, Samuel Guibal, Luca Guidoni

    We describe and experimentally implement a single-ion local thermometry technique with absolute sensitivity adaptable to all laser-cooled atomic ion species. The technique is based on the velocity-dependent spectral shape of a quasi-dark resonance tailored by two driving fields in a J→J transition such that the two fields can be derived from the same laser source, leading to a negligible relative phase shift. We validated the method and tested its performance in an experiment on a single Sr+88 ion cooled in a surface radio-frequency trap. We first applied the technique to characterize the heating rate of the surface trap. We then measured the stationary temperature of the ion as a function of cooling laser detuning in the Doppler regime. The results agree with theoretical calculations, with an absolute error smaller than 100 μK at 500 μK, in a temperature range between 0.5 and 3 mK and in the absence of adjustable parameters. This simple-to-implement and reliable method opens the way to fast absolute measurements of single-ion temperatures in future experiments dealing with heat transport in ion chains or thermodynamics at the single-ion level.


  • Ion microtrap technology for quantum information and precision spectroscopy

    by Jean-Pierre Likforman, Vincent Tugayé, Samuel Guibal, Luca Guidoni

    We design and operate micro-fabricated ion surface traps made of gold electrodes deposited on silica substrates.We clean the electrodes by ion bombardment, load the traps with single ions, and characterize the heating-rate by Doppler-re-cooling.

  • Open Access

    Precision measurement of the branching fractions of the5pP1/22state inSr+88with a single ion in a microfabricated surface trap

    by Jean-Pierre Likforman, Vincent Tugayé, Samuel Guibal, Luca Guidoni

    We measured the branching fractions for the decay of the 5pP1/22 state of Sr+88 by applying a recently demonstrated photon-counting sequential method [M. Ramm, T. Pruttivarasin, M. Kokish, I. Talukdar, and H. Häffner, Phys. Rev. Lett. 111, 023004 (2013)] to a single ion laser cooled in a microfabricated surface trap. The branching fraction for the decay into the 5sS1/22 ground level was found to be p=0.9449(5). This result is in good agreement with recent theoretical calculations but disagrees with previous experimental measurements, however affected by a one-order-of-magnitude larger uncertainty. This experiment demonstrates that microtrap technology is also applicable in the domain of precision measurements and spectroscopy.