Liang Yan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Liang Yan has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Feng Siman
Faculty of Science, Beijing University of Technology, Beijing, China
1 shared publicationXia Cai
School of Science, Hebei University of Science and Technology, Shijiazhuang, China
1 shared publication- Xia Cai
School of Science, Hebei University of Science and Technology, Shijiazhuang 050018, China
1 shared publication - Yan Li
School of Sciences Hebei University of Science and Technology Shijiazhuang China
1 shared publication - Yutong Wu
School of Science, Hebei University of Science and Technology, Shijiazhuang 050018, China
1 shared publication
Latest Publications
- 2 May 2022
- Published by Taylor & Francis in Communications in Statistics - Simulation and Computation
- Vol. 53 (5) , 2097-2107
Generalized fiducial inference for the lower confidence limit of reliability based on Weibull distribution
Reliability performance, especially the lower confidence limit of reliability, plays an important role in reliability assessment, and it is also of concern to researchers and engineers. In this article, a novel estimate of the lower confidence limit of the reliability for two-parameter Weibull distribution is proposed based on the generalized fiducial inference. The corresponding adaptive Metropolis-Hastings within Gibbs algorithm is provided to analyze the generalized fiducial lower confidence limit. The proposed lower confidence limit of the reliability is compared with that from frequentist method. In addition, this novel procedure is generalized to the series system and the parallel system which consists of identical Weibull components. Simulation results show that the proposed generalized fiducial lower confidence limit is more applicable than the frequentist method, especially for the case of small sample size. Finally, the MOS transistor lifetime data is used to illustrate the new procedure.
- 2 May 2022
- Published by Taylor & Francis in Communications in Statistics - Simulation and Computation
- Vol. 53 (5) , 2097-2107
Generalized fiducial inference for the lower confidence limit of reliability based on Weibull distribution
Reliability performance, especially the lower confidence limit of reliability, plays an important role in reliability assessment, and it is also of concern to researchers and engineers. In this article, a novel estimate of the lower confidence limit of the reliability for two-parameter Weibull distribution is proposed based on the generalized fiducial inference. The corresponding adaptive Metropolis-Hastings within Gibbs algorithm is provided to analyze the generalized fiducial lower confidence limit. The proposed lower confidence limit of the reliability is compared with that from frequentist method. In addition, this novel procedure is generalized to the series system and the parallel system which consists of identical Weibull components. Simulation results show that the proposed generalized fiducial lower confidence limit is more applicable than the frequentist method, especially for the case of small sample size. Finally, the MOS transistor lifetime data is used to illustrate the new procedure.
- Open Access
- 29 November 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (23) , 11317
Fiducial Lower Confidence Limit of Reliability for a Power Distribution System
Reliability performance, especially the lower confidence limit of reliability, plays an important role in system risk and safety assessment. A good estimator of the lower confidence limit of system reliability can help engineers to make the right decisions. Based on the lifetime of the key component in a typical satellite intelligent power distribution system, the generalized fiducial method is adopted to estimate the lower confidence limit of the system reliability in this paper. First, the generalized pivotal quantity and the lower confidence limit of reliability for the key component are derived for the lifetimes of the exponential-type and Weibull-type components. Simulations show that the sample median is more appropriate than the sample mean when the lower confidence limit of reliability is estimated. Moreover, the lower confidence limit of reliability is obtained for the typical satellite intelligent power distribution system through the pseudo-lifetime data of the metallic oxide semiconductor field effect transistor. The lower confidence limit of reliability for this power distribution system at 15 years is 0.998, which meets the factory’s reliability requirement. Finally, through the comparison, a hot standby subsystem can be substituted with a cold standby subsystem to increase the lower confidence limit of the system reliability.
- 29 November 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (23) , 11317
Open AccessFiducial Lower Confidence Limit of Reliability for a Power Distribution System
Reliability performance, especially the lower confidence limit of reliability, plays an important role in system risk and safety assessment. A good estimator of the lower confidence limit of system reliability can help engineers to make the right decisions. Based on the lifetime of the key component in a typical satellite intelligent power distribution system, the generalized fiducial method is adopted to estimate the lower confidence limit of the system reliability in this paper. First, the generalized pivotal quantity and the lower confidence limit of reliability for the key component are derived for the lifetimes of the exponential-type and Weibull-type components. Simulations show that the sample median is more appropriate than the sample mean when the lower confidence limit of reliability is estimated. Moreover, the lower confidence limit of reliability is obtained for the typical satellite intelligent power distribution system through the pseudo-lifetime data of the metallic oxide semiconductor field effect transistor. The lower confidence limit of reliability for this power distribution system at 15 years is 0.998, which meets the factory’s reliability requirement. Finally, through the comparison, a hot standby subsystem can be substituted with a cold standby subsystem to increase the lower confidence limit of the system reliability.