Rüya Sessiz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Rüya Sessiz has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Gamze Coşan Ata
Department of Dentomaxillofacial Radiology, School of Dentistry, Çanakkale Onsekiz Mart University, Çanakkale 17100, Türkiye
2 shared publications - Hakan Eren
Çanakkale Onsekiz Mart University, Faculty of Dentistry
2 shared publications - Yeşim Deniz
Department of Dental and Maxillofacial Radiology, Faculty of Dentistry, Çanakkale Onsekiz Mart University, Çanakkale, Turkey
2 shared publications - Öznur Sarıyılmaz
Department of Endodontics, Faculty of Dentistry, Çanakkale Onsekiz Mart University, Çanakkale, Türkiye
2 shared publications - Emek Bayındır
Department of Endodontics, Faculty of Dentistry, Çanakkale Onsekiz Mart University, Çanakkale, Türkiye
1 shared publication Emre Köse
Department of Dentomaxillofacial Radiology Faculty of Dentistry Aydın Adnan Menderes University Aydın Turkey
1 shared publication
Latest Publications
- 29 June 2026
- Published by Marmara University in Clinical and Experimental Health Sciences
- Vol. 16 (2) , 324-330
Reassessment of the Anterior Mandibular Safe Zone: A CBCT-Based Analysis of Accessory Canal Prevalence and Sex Differences
Objective: The aim of this study was to evaluate the medial and lateral lingual canals and anterior labial accessory canals in the mandibular anterior region, called the safe zone, using cone beam computed tomography (CBCT) images and to evaluate their prevalence, location and laterality, and possible sex-related differences.Methods: CBCT images of 167 individuals (76 males, 91 females) were analyzed. Accessory canals in the anterior mandible were classified as medial lingual, lateral lingual, and anterior labial canals. The presence and number of medial lingual canals, their relationship to the genial tubercles (superior, median, inferior), and the presence and laterality of the lateral lingual and anterior labial canals were recorded. Sex-related differences were evaluated using chi-square or Fisher’s exact tests, with post-hoc analyses for multiple comparisons (p < .05).Results:The medial lingual canal was present in all cases, with females more frequently exhibiting a single canal (p < .05). The superior and inferior canals were observed in 80.8% and 72.5% of CBCT images, respectively, with the inferior canal significantly more common in males (p < .05). The anterior lateral lingual canal was present in 69.5% of cases, and the anterior labial canal in 40.7%, with a significantly higher prevalence in males (p < .05); no significant sex differences were found in the laterality of either canal.Conclusion:Accessory canals in the anterior mandible are common anatomical variations, with certain sex-related differences. Awareness of their prevalence and distribution is crucial to minimize neurovascular complications during implant placement and other anterior mandibular surgeries.
- 29 June 2026
- Published by Marmara University in Clinical and Experimental Health Sciences
- Vol. 16 (2) , 324-330
Reassessment of the Anterior Mandibular Safe Zone: A CBCT-Based Analysis of Accessory Canal Prevalence and Sex Differences
Objective: The aim of this study was to evaluate the medial and lateral lingual canals and anterior labial accessory canals in the mandibular anterior region, called the safe zone, using cone beam computed tomography (CBCT) images and to evaluate their prevalence, location and laterality, and possible sex-related differences.Methods: CBCT images of 167 individuals (76 males, 91 females) were analyzed. Accessory canals in the anterior mandible were classified as medial lingual, lateral lingual, and anterior labial canals. The presence and number of medial lingual canals, their relationship to the genial tubercles (superior, median, inferior), and the presence and laterality of the lateral lingual and anterior labial canals were recorded. Sex-related differences were evaluated using chi-square or Fisher’s exact tests, with post-hoc analyses for multiple comparisons (p < .05).Results:The medial lingual canal was present in all cases, with females more frequently exhibiting a single canal (p < .05). The superior and inferior canals were observed in 80.8% and 72.5% of CBCT images, respectively, with the inferior canal significantly more common in males (p < .05). The anterior lateral lingual canal was present in 69.5% of cases, and the anterior labial canal in 40.7%, with a significantly higher prevalence in males (p < .05); no significant sex differences were found in the laterality of either canal.Conclusion:Accessory canals in the anterior mandible are common anatomical variations, with certain sex-related differences. Awareness of their prevalence and distribution is crucial to minimize neurovascular complications during implant placement and other anterior mandibular surgeries.
- 6 March 2026
- Published by Elsevier in Journal of Endodontics
- Vol. 52 (6) , 1023-1031
Influence of Sodium Hypochlorite Heating Method, Activation Technique, and Concentration on Organic Tissue Removal in Simulated Internal Resorption Cavities
- 6 March 2026
- Published by Elsevier in Journal of Endodontics
- Vol. 52 (6) , 1023-1031
Influence of Sodium Hypochlorite Heating Method, Activation Technique, and Concentration on Organic Tissue Removal in Simulated Internal Resorption Cavities
- 25 December 2025
- Published by Adnan Menderes University in Meandros Medical and Dental Journal
- Vol. 26 (4) , 415-420
The Effect of Temperature on the Efficacy of Solvents in Endodontic Retreatment: In Vitro Study
Objective: Complete removal of root canal filling materials is critical for the success of non-surgical endodontic retreatment. Solvents are specifically recommended when mechanical methods are inadequate. This study was evaluated the effectiveness of eucalyptol oil, orange oil, and turpentine oil in removing canal fillings at different temperatures. Material and Methods: Sixty premolars were divided into two main and three subgroups based on solvent temperature and solvent type, respectively. The canals were filled using gutta-percha and AH Plus. After 21 days, the assigned solvent was applied, and canal filling was removed using ProTaper Universal Retreatment System. CBCT images were taken before and after the procedures, and residual filling volume was measured using 3D Slicer software. Results: Residual filling volumes differed significantly between solvents (p0.05). Turpentine left the most residue at both temperatures. Lower temperatures reduced remnants, with a significant reduction only in the turpentine group. Conclusion: Pine turpentine left the most residual material among the solvents used at both temperatures. Although the use of solvents at lower temperatures reduced the amount of residual material, this reduction was statistically significant only in the pine turpentine group.
- 25 December 2025
- Published by Adnan Menderes University in Meandros Medical and Dental Journal
- Vol. 26 (4) , 415-420
The Effect of Temperature on the Efficacy of Solvents in Endodontic Retreatment: In Vitro Study
Objective: Complete removal of root canal filling materials is critical for the success of non-surgical endodontic retreatment. Solvents are specifically recommended when mechanical methods are inadequate. This study was evaluated the effectiveness of eucalyptol oil, orange oil, and turpentine oil in removing canal fillings at different temperatures. Material and Methods: Sixty premolars were divided into two main and three subgroups based on solvent temperature and solvent type, respectively. The canals were filled using gutta-percha and AH Plus. After 21 days, the assigned solvent was applied, and canal filling was removed using ProTaper Universal Retreatment System. CBCT images were taken before and after the procedures, and residual filling volume was measured using 3D Slicer software. Results: Residual filling volumes differed significantly between solvents (p0.05). Turpentine left the most residue at both temperatures. Lower temperatures reduced remnants, with a significant reduction only in the turpentine group. Conclusion: Pine turpentine left the most residual material among the solvents used at both temperatures. Although the use of solvents at lower temperatures reduced the amount of residual material, this reduction was statistically significant only in the pine turpentine group.
- Open Access
- 1 January 2025
- Published by Termedia Sp. z.o.o. in Journal of Stomatology
- Vol. 78 (1) , 52-58
Is panoramic radiography sufficient enough for the evaluation of mandibular condyle osseous changes and cortication types?
Introduction: Temporomandibular disorders (TMDs) are identified by cranio-facial pain that affects the temporomandibular joint or masticatory muscles, along with symptoms, such as limited mouth opening, clicking, and crepitus. Objectives: The aim of this study was to investigate the accuracy...
- 1 January 2025
- Published by Termedia Sp. z.o.o. in Journal of Stomatology
- Vol. 78 (1) , 52-58
Open AccessIs panoramic radiography sufficient enough for the evaluation of mandibular condyle osseous changes and cortication types?
Introduction: Temporomandibular disorders (TMDs) are identified by cranio-facial pain that affects the temporomandibular joint or masticatory muscles, along with symptoms, such as limited mouth opening, clicking, and crepitus. Objectives: The aim of this study was to investigate the accuracy...
- 5 January 2024
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 63 (1) , 39-45
Comparison of CBCT radiation doses with conventional radiographs in TMJ imaging using Monte Carlo simulations
Three-dimensional imaging methods are widely used for evaluation of bony changes of temporomandibular joint (TMJ). Besides, lateral and posterio-anterior TMJ projections in both closed- and open-jaw positions for each temporomandibular joint are used as two-dimensional diagnostic tools. The purpose of the present study was to compare effective and mean organ absorbed doses of plain radiography techniques with those of different modalities of cone beam computed tomography (CBCT) scanning of an adult’s temporomandibular joint. PCXMC 2.0 software was used to calculate mean organ and effective doses. A NewTom CBCT device (Newtom 5G XL; QR systems; Verona, Italy) was simulated at 360° rotation using a 6 × 6 cm2 FOV in standard and high-resolution modes. Lateral and posterio-anterior TMJ plain projections were simulated according to recommendations of the manufacturer of the Planmeca ProMax® 2D S3 device. Doses for both projections were simulated with Monte Carlo methods and the International Commission on radiological protection adult reference computational phantoms. The highest mean organ absorbed doses occurred in bone surfaces, salivary glands, and skull for posterio-anterior TMJ and lateral TMJ, and for CBCT scanning in all examinations. The effective doses of posterio-anterior and lateral TMJ plain radiographs were found to be higher than those of the Standard Mode-Eco Scan CBCT. Therefore, the lowest effective dose was calculated in Standard Mode-Eco Scan CBCT. It is concluded that NewTom 5G XL Standard Mode-Eco Scan CBCT can be used instead of plain radiographs (lateral and posterio-anterior TMJ) in temporomandibular joint imaging as it allows visualizing the three-dimensional structure of the temporomandibular joint as an advantage.
- 5 January 2024
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 63 (1) , 39-45
Comparison of CBCT radiation doses with conventional radiographs in TMJ imaging using Monte Carlo simulations
Three-dimensional imaging methods are widely used for evaluation of bony changes of temporomandibular joint (TMJ). Besides, lateral and posterio-anterior TMJ projections in both closed- and open-jaw positions for each temporomandibular joint are used as two-dimensional diagnostic tools. The purpose of the present study was to compare effective and mean organ absorbed doses of plain radiography techniques with those of different modalities of cone beam computed tomography (CBCT) scanning of an adult’s temporomandibular joint. PCXMC 2.0 software was used to calculate mean organ and effective doses. A NewTom CBCT device (Newtom 5G XL; QR systems; Verona, Italy) was simulated at 360° rotation using a 6 × 6 cm2 FOV in standard and high-resolution modes. Lateral and posterio-anterior TMJ plain projections were simulated according to recommendations of the manufacturer of the Planmeca ProMax® 2D S3 device. Doses for both projections were simulated with Monte Carlo methods and the International Commission on radiological protection adult reference computational phantoms. The highest mean organ absorbed doses occurred in bone surfaces, salivary glands, and skull for posterio-anterior TMJ and lateral TMJ, and for CBCT scanning in all examinations. The effective doses of posterio-anterior and lateral TMJ plain radiographs were found to be higher than those of the Standard Mode-Eco Scan CBCT. Therefore, the lowest effective dose was calculated in Standard Mode-Eco Scan CBCT. It is concluded that NewTom 5G XL Standard Mode-Eco Scan CBCT can be used instead of plain radiographs (lateral and posterio-anterior TMJ) in temporomandibular joint imaging as it allows visualizing the three-dimensional structure of the temporomandibular joint as an advantage.
- Open Access
- 6 December 2023
- Published by Ankara University in European Annals of Dental Sciences
- Vol. 50 (Suppl 1) , 19-22
Ultrasound examination of various dental materials and foreign bodies
Purpose To provide information on the sonographic properties of different foreign bodies and dental materials to help with diagnosis. Materials & Methods The investigation contained 10 various dental materials and foreign bodies that were consisting of composite, glass ionomer cement, gutta percha, suture, wooden, stone, canal file, acrylic, alginate, and silicone impression material. The objects were embedded to chicken meat and imaged using ultrasonography (USG). Their visibility and posterior acoustic behaviors were evaluated by both hockey and linear transducers. The actual sizes of this objects and measured dimensions by transducers were compared. Results Only gutta percha could not be distinguished in chicken meat. No difference was observed between the measurements made with the hockey and linear transducers and the actual size. Conclusion USG is a useful method for detecting and measuring foreign bodies and dental materials in soft tissues.
- 6 December 2023
- Published by Ankara University in European Annals of Dental Sciences
- Vol. 50 (Suppl 1) , 19-22
Open AccessUltrasound examination of various dental materials and foreign bodies
Purpose To provide information on the sonographic properties of different foreign bodies and dental materials to help with diagnosis. Materials & Methods The investigation contained 10 various dental materials and foreign bodies that were consisting of composite, glass ionomer cement, gutta percha, suture, wooden, stone, canal file, acrylic, alginate, and silicone impression material. The objects were embedded to chicken meat and imaged using ultrasonography (USG). Their visibility and posterior acoustic behaviors were evaluated by both hockey and linear transducers. The actual sizes of this objects and measured dimensions by transducers were compared. Results Only gutta percha could not be distinguished in chicken meat. No difference was observed between the measurements made with the hockey and linear transducers and the actual size. Conclusion USG is a useful method for detecting and measuring foreign bodies and dental materials in soft tissues.
- 17 July 2023
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 45 (11) , 1497-1504
Evaluation of sex dimorphism of the mandible with geometric morphometric analysis: conventional and reconstructed panoramic radiography study
Purpose The purpose of the study was to investigate the mandible shape dimorphism between males and females both on conventional panoramic radiographs (cPR) and reconstructed panoramic radiographs obtained from cone beam computed tomography (rPR) with geometric morphometric method. Methods Panoramic radiographs and cone beam computed tomography scans were performed on 33 males and 35 females with median age 23.0 (13.0–57.0) years old. The mandibular shape comparisons between genders were examined with Procrustes analysis, mandible shape classification analysis was made with principal component analysis and shape deformations were concluded from thin plate spline (TPS) analysis. Results Age had no statistically significant difference between gender (p = 0.580). For the shape of mandible on cPR and rPR, there were statistically significant differences between males and females (p = 0.002, p = 0.032, respectively). The shape variabilities of mandible on cPR for females were 0.054 and for males 0.053. The shape variabilities of mandible on rPR for females were 0.051 and for males 0.049. Both on cPR and rPR, the shape variability of the females’ mandible was similar within their group, the shape variability of the males’ mandible was similar within their group. In the examination of mandibular dimorphism in cPR, maximal deformations were seen in the region between the mandibular notch, posterior ramus, anterior ramus, gonion, in both sides, in TPS graphs. On the other hand, a high level of deformations was observed in all landmarks that define the mandibular shape on rPR. Conclusions The mandible dimorphism can be detected in the examination performed with geometric morphometric methods on cPR and rPR. While mandible shape differences according to gender are seen most in the ramus region in cPR, differences can be detected in all landmarks in rRP.
- 17 July 2023
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 45 (11) , 1497-1504
Evaluation of sex dimorphism of the mandible with geometric morphometric analysis: conventional and reconstructed panoramic radiography study
Purpose The purpose of the study was to investigate the mandible shape dimorphism between males and females both on conventional panoramic radiographs (cPR) and reconstructed panoramic radiographs obtained from cone beam computed tomography (rPR) with geometric morphometric method. Methods Panoramic radiographs and cone beam computed tomography scans were performed on 33 males and 35 females with median age 23.0 (13.0–57.0) years old. The mandibular shape comparisons between genders were examined with Procrustes analysis, mandible shape classification analysis was made with principal component analysis and shape deformations were concluded from thin plate spline (TPS) analysis. Results Age had no statistically significant difference between gender (p = 0.580). For the shape of mandible on cPR and rPR, there were statistically significant differences between males and females (p = 0.002, p = 0.032, respectively). The shape variabilities of mandible on cPR for females were 0.054 and for males 0.053. The shape variabilities of mandible on rPR for females were 0.051 and for males 0.049. Both on cPR and rPR, the shape variability of the females’ mandible was similar within their group, the shape variability of the males’ mandible was similar within their group. In the examination of mandibular dimorphism in cPR, maximal deformations were seen in the region between the mandibular notch, posterior ramus, anterior ramus, gonion, in both sides, in TPS graphs. On the other hand, a high level of deformations was observed in all landmarks that define the mandibular shape on rPR. Conclusions The mandible dimorphism can be detected in the examination performed with geometric morphometric methods on cPR and rPR. While mandible shape differences according to gender are seen most in the ramus region in cPR, differences can be detected in all landmarks in rRP.
- 1 December 2021
- Published by Adnan Menderes University in Meandros Medical and Dental Journal
- Vol. 22 (3) , 229-234
Assessment of Morphological Alterations of Temporomandibular Joint Articular Surfaces in Patients with Temporomandibular Dysfunction
- 1 December 2021
- Published by Adnan Menderes University in Meandros Medical and Dental Journal
- Vol. 22 (3) , 229-234
Assessment of Morphological Alterations of Temporomandibular Joint Articular Surfaces in Patients with Temporomandibular Dysfunction