JHJiaru He

Jiaru He

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jiaru He has a total of 18 co-authors. Here are the top co-authors by number of shared publications:

  • Junwei Wu

    State Key Laboratory of Precision Electronic Manufacturing Technology and Equipment, Guangdong University of Technology, Guangzhou 510006, China

    3 shared publications
  • Lvming Zeng

    State Key Laboratory of Precision Electronic Manufacturing Technology and Equipment, Guangdong University of Technology, Guangzhou 510006, China

    3 shared publications
  • Maodan Yuan

    State Key Laboratory of Precision Electronic Manufacturing Technology and Equipment, Guangdong University of Technology, Guangzhou 510006, China

    3 shared publications
  • Xuanrong Ji

    State Key Laboratory of Precision Electronic Manufacturing Technology and Equipment, School of Electromechanical Engineering, Guangdong University of Technology, Guangzhou 510006, China

    3 shared publications
  • Yan Chen

    State Key Laboratory of Precision Electronic Manufacturing Technology and Equipment, Guangdong University of Technology, Guangzhou 510006, China

    3 shared publications
  • Jiejun Zhu

    Guangdong Institute of Intelligence Science and Technology Zhuhai Guangdong P. R. China

    2 shared publications

Latest Publications

  • Open Access

    Ultrasound Modulation of Visual Circuits in Mice Independent of Auditory Confound

    by Jiaru He, Jiejun Zhu, Xinxin Wang, Zihao Chen, Jin Yang, Zhen Yuan, Hongzhi Xu, Lei Sun, Zhihai Qiu

    Despite its growing potential as a noninvasive neuromodulation technology, the fundamental biophysical mechanism of focused ultrasound neuromodulation (FUN) remains elusive. Progress has been hampered by a persistent auditory confound, making it difficult to isolate the direct mechanical effects on neural circuits. To overcome this barrier, we employed two‐photon calcium imaging (2PCI) in the primary visual cortex (V1) of deafened mice. Here, this study identifies a sparse (<1.5%) and spatially distributed population of neurons that is robustly and directly activated by ultrasound in a pressure‐dependent manner. Crucially, this sparse, direct activation is sufficient to modulate the broader visual circuit, altering the response dynamics of neighboring neurons to visual stimuli. By unequivocally decoupling direct neuromodulation from auditory artifacts, the findings identify a key cellular substrate for FUN and establish a robust framework for future studies. This work paves the way for targeted investigations into the precise biophysical mechanisms governing the interaction between ultrasound and neurons.

  • Open Access

    Ultrasound Directly Activates Sparse Neurons and Modulates Visual Circuits in Deafened Mice

    by Jiaru He, Jiejun Zhu, Xinxin Wang, Zihao Chen, Jin Yang, Zhen Yuan, Hongzhi Xu, Lei Sun, Zhihai Qiu

    Focused ultrasound neuromodulation (FUN) is widely regarded as a next-generation technology for neural modulation, with applications spanning rodents, non-human primates, and humans. While mechanistic studies are advancing, a persistent confound—auditory interference—casts doubt on whether ultrasound exerts direct mechanical effects or merely indirect auditory responses. To resolve this, we engineered a circular ultrasound transducer compatible with two-photon calcium imaging and examined its effects on the primary visual cortex (V1) of surgically deafened mice, eliminating auditory contributions. Our results reveal that ultrasound directly activates a sparse subset of ultrasound-sensitive neurons (USSN) (response rate >30%) in V1, comprising only a small fraction of the total population and exhibiting a spatially sparse distribution. The proportion of USSN scale with ultrasound pressure, confirming a direct neuromodulatory effect independent of audition. Intriguingly, despite this sparse activation, ultrasound significantly modulates V1 circuitry: it alters the dynamics of light-sensitive neurons (LSN), with subsets showing excitation, inhibition, or no change in response to visual stimuli. These findings provide the first rigorous in-vivo evidence that FUN induces direct mechanical effects on neural activity, disentangling them from auditory confounds. By demonstrating both the specificity and broader circuit-level impact of ultrasound in deafened mice, this study reframes our understanding of FUN’s mechanisms and strengthens its potential as a precise neuromodulatory tool. Highlights: Ultrasound directly activates sparse neurons in deafened mice, demonstrating auditory-independent effects. Sparse ultrasound-sensitive neurons in V1 show pressure-dependent responses. Ultrasound modulates visual circuitry, with diverse excitatory and inhibitory effects.

  • Transcranial ultrasound neuromodulation facilitates isoflurane-induced general anesthesia recovery and improves cognition in mice

    by Jiaru He, Yiyue Zhu, Canwen Wu, Junwei Wu, Yan Chen, Maodan Yuan, Zhongwen Cheng, Lvming Zeng, Xuanrong Ji


  • A Spatial Multitarget Ultrasound Neuromodulation System Using High-Powered 2-D Array Transducer

    by Xiaopeng Zhuang, Jiaru He, Junwei Wu, Xuanrong Ji, Yan Chen, Maodan Yuan, Lvming Zeng

    Transcranial focused ultrasound (tFUS) is increasingly used in experimental neuroscience due to its neuromodulatory effectiveness in animal studies. However, achieving multitarget tFUS in small animals is typically limited by transducer size, energy transfer efficiency, and brain volume. The objective of this work was to construct an ultrasound system for multitarget neuromodulation in small animals. First, a miniaturized high-powered 2-D array transducer was developed. The phase delay of each array element was calculated based on the multifocal time-reversal method, generating multiple foci simultaneously in a 3-D field. The effects of the axial focal length, interfocus spacing (lateral distance between the two focal centers), and the number of foci on the focal properties of the pressure field were examined through numerical simulations. In-vitro ultrasonic measurements and transcranial simulations on a rat skull were conducted. The minimum interfocus spacing separating two −6-dB foci and the peak full-width at half-maximum were positively correlated with axial focal length; the relative relationship between the interfocus spacing and pressure field properties was similar for each axial focal length. The maximum acoustic pressure and spatial average intensity at focus in deionized water were 2.21 MPa and 133 W/cm 2 , respectively. The simulated and experimental results were compared, demonstrating agreement in both peak position and focus shape. The ultrasound system can provide a neuroscientific platform for evaluating the feasibility of multitarget ultrasound stimulation treatment protocols, thus improving the understanding of functional neuroanatomy.


  • Multitarget Transcranial Ultrasound Therapy in Small Animals Based on Phase-Only Acoustic Holographic Lens

    by Jiaru He, Junwei Wu, Yiyue Zhu, Yan Chen, Maodan Yuan, Lvming Zeng, Xuanrong Ji

    Transcranial ultrasound therapy has become a noninvasive method for treating neurological and psychiatric disorders, and studies have further demonstrated that multitarget transcranial ultrasound therapy is a better solution. At present, multitarget transcranial ultrasound therapy in small animals can only be achieved by the multitransducer or phased array. However, multiple transducers may cause spatial interference, and the phased array system is complicated, expensive, and especially unsuitable for small animals. This study is the first to design and fabricate a miniature acoustic holography lens for multitarget transcranial ultrasound therapy in rats. The acoustic holographic lens, working at a frequency of 1.0 MHz, with a size of 10.08 mm $\times10.08$ mm and a pixel resolution of 0.72 mm, was designed, optimized, and fabricated. The dual-focus transcranial ultrasound generated based on the lens was measured; the full-width at half-maximum (FWHM) of the focal spots in the ${y}$ -direction was 2.15 and 2.27 mm and in the ${z}$ -direction was 2.3 and 2.36 mm. The focal length was 5.4 mm, and the distance between the two focuses was 5.6 mm, close to the desired values of 5.4 and 6.0 mm. Finally, the multiple-target blood–brain barrier opening in rats’ bilateral secondary visual cortex (mediolateral area, V2ML) was demonstrated using the transcranial ultrasound therapy system based on the lens. These results demonstrate the good performance of the multitarget transcranial ultrasound therapy system for small animals, including high spatial resolution, small size, and low cost.