Joonhaeng Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Joonhaeng Lee has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Jongbin Kim
Department of Pediatric Dentistry, College of Dentistry, Dankook University, Cheonan, Korea
24 shared publications - Miran Han
Department of Pediatric Dentistry, College of Dentistry, Dankook University, Cheonan, Korea
24 shared publications - Jisun Shin
Department of Pediatric Dentistry, College of Dentistry, Dankook University, Cheonan, Korea
23 shared publications - Yu-Jin Kim
Institute of Tissue Regeneration Engineering (ITREN), Dankook University, 119 Dandae-ro, Cheonan 31116, Republic of Korea
5 shared publications - Jung-Hwan Lee
Institute of Tissue Regeneration Engineering (ITREN), Dankook University, 119 Dandae-ro, Cheonan 31116, Republic of Korea
4 shared publications - Gahee Son
Department of Pediatric Dentistry Dankook University Jukjeon Dental Hospital Yongin Republic of Korea
2 shared publications
Latest Publications
- Open Access
- 30 September 2026
- Published by Korean Academy of Preventive Dentistry in International Journal of Clinical Preventive Dentistry
- Vol. 22 (3) , 94-105
Effect of a Closed Multi-channel Oral Irrigator (COMORAL) on Oral Rinse Turbidity and Clinical Gingival Indices: A Prospective Clinical Trial
JiHoon Jung, Jongbin Kim, MiRan Han, JongSoo Kim, JoonHaeng Lee, JiSun Shin. IJCPD 2026;22:94-105. https://doi.org/10.15236/ijcpd.2026.22.3.94
- 30 September 2026
- Published by Korean Academy of Preventive Dentistry in International Journal of Clinical Preventive Dentistry
- Vol. 22 (3) , 94-105
Open AccessEffect of a Closed Multi-channel Oral Irrigator (COMORAL) on Oral Rinse Turbidity and Clinical Gingival Indices: A Prospective Clinical Trial
JiHoon Jung, Jongbin Kim, MiRan Han, JongSoo Kim, JoonHaeng Lee, JiSun Shin. IJCPD 2026;22:94-105. https://doi.org/10.15236/ijcpd.2026.22.3.94
- Open Access
- 30 September 2026
- Published by Korean Academy of Preventive Dentistry in International Journal of Clinical Preventive Dentistry
- Vol. 22 (3) , 88-93
Effect of Fluoride Varnish Vehicle on Enamel Remineralization
Dayeon Lee, Jongsoo Kim, Joonhaeng Lee, Jongbin Kim, Miran Han, Jisun Shin, Junhyeok Kang. IJCPD 2026;22:88-93. https://doi.org/10.15236/ijcpd.2026.22.3.88
- 30 September 2026
- Published by Korean Academy of Preventive Dentistry in International Journal of Clinical Preventive Dentistry
- Vol. 22 (3) , 88-93
Open AccessEffect of Fluoride Varnish Vehicle on Enamel Remineralization
Dayeon Lee, Jongsoo Kim, Joonhaeng Lee, Jongbin Kim, Miran Han, Jisun Shin, Junhyeok Kang. IJCPD 2026;22:88-93. https://doi.org/10.15236/ijcpd.2026.22.3.88
- Open Access
- 31 August 2026
- Published by Korean Academy of Pediatric Dentistry in THE JOURNAL OF THE KOREAN ACADEMY OF PEDTATRIC DENTISTRY
- Vol. 53 (3) , 271-282
Evaluation of Color Changes in Composite Resins Using Artificial Intelligence-Based Digital Photography
This study aimed to compare color measurements of composite resins obtained using a spectrophotometer and a digital camera, and to evaluate the feasibility of an image-based classification model developed using Google Cloud Vertex Artificial Intelligence (AI) AutoML. Filtek Z350 XT (A2) specimens were immersed in a coffee solution at 37°C for 1, 3, or 5 hours, and CIE 1976 L*a*b* (CIELAB) color coordinates and ΔE*ab(stain) were recorded before and after immersion. Two AutoML models (VITA shade guide classification and ΔE*ab(stain) classification) were trained using standardized images. Digital photography yielded significantly lower a* values than spectrophotometry in all groups, whereas b* values did not differ significantly. Mean ΔE*ab(inter) values between instruments remained below 2.7 in all groups, indicating clinically acceptable agreement. Both AI models achieved an accuracy of 93.3%, exhibiting stable performance in identifying specimens with ΔE*ab(inter) < 2.7. Despite systematic bias in a* measurements, AI-assisted digital photography provided clinically acceptable color assessment under controlled conditions, supporting its potential as an adjunctive tool to spectrophotometric evaluation.
- 31 August 2026
- Published by Korean Academy of Pediatric Dentistry in THE JOURNAL OF THE KOREAN ACADEMY OF PEDTATRIC DENTISTRY
- Vol. 53 (3) , 271-282
Open AccessEvaluation of Color Changes in Composite Resins Using Artificial Intelligence-Based Digital Photography
This study aimed to compare color measurements of composite resins obtained using a spectrophotometer and a digital camera, and to evaluate the feasibility of an image-based classification model developed using Google Cloud Vertex Artificial Intelligence (AI) AutoML. Filtek Z350 XT (A2) specimens were immersed in a coffee solution at 37°C for 1, 3, or 5 hours, and CIE 1976 L*a*b* (CIELAB) color coordinates and ΔE*ab(stain) were recorded before and after immersion. Two AutoML models (VITA shade guide classification and ΔE*ab(stain) classification) were trained using standardized images. Digital photography yielded significantly lower a* values than spectrophotometry in all groups, whereas b* values did not differ significantly. Mean ΔE*ab(inter) values between instruments remained below 2.7 in all groups, indicating clinically acceptable agreement. Both AI models achieved an accuracy of 93.3%, exhibiting stable performance in identifying specimens with ΔE*ab(inter) < 2.7. Despite systematic bias in a* measurements, AI-assisted digital photography provided clinically acceptable color assessment under controlled conditions, supporting its potential as an adjunctive tool to spectrophotometric evaluation.
- Open Access
- 31 December 2025
- Published by Korean Academy of Preventive Dentistry in International Journal of Clinical Preventive Dentistry
- Vol. 21 (4) , 128-135
Analysis of the Characteristics of Pediatric Orthodontic Patients at Dankook University Dental Hospital: A 10-Year Retrospective Analysis
Junmo Jeong, Jongsoo Kim, Joonhaeng Lee, Jongbin Kim, Jisun Shin, Miran Han. IJCPD 2025;21:128-35. https://doi.org/10.15236/ijcpd.2025.21.4.128
- 31 December 2025
- Published by Korean Academy of Preventive Dentistry in International Journal of Clinical Preventive Dentistry
- Vol. 21 (4) , 128-135
Open AccessAnalysis of the Characteristics of Pediatric Orthodontic Patients at Dankook University Dental Hospital: A 10-Year Retrospective Analysis
Junmo Jeong, Jongsoo Kim, Joonhaeng Lee, Jongbin Kim, Jisun Shin, Miran Han. IJCPD 2025;21:128-35. https://doi.org/10.15236/ijcpd.2025.21.4.128
- Open Access
- 30 November 2025
- Published by Korean Academy of Pediatric Dentistry in THE JOURNAL OF THE KOREAN ACADEMY OF PEDTATRIC DENTISTRY
- Vol. 52 (4) , 425-436
Evaluation of Shear Bond Strength of Submicron Polycrystalline Alumina Ceramic with Different Surface Treatments and Luting Cements
Submicron polycrystalline alumina ceramic offers excellent mechanical strength and translucency, making it a promising material for pediatric crown restorations. However, due to its acid resistance and low surface energy, reliable bonding requires appropriate surface treatments and selection of compatible cement materials. This study aimed to evaluate the shear bond strength of submicron polycrystalline alumina ceramics subjected to various surface treatments and bonded with different types of luting cements. Ninety specimens were divided into three surface treatment groups: no treatment, sandblasting, and Rocatec treatment. Each group was further subdivided by cement type: glass ionomer (GI) cement (GC Fuji I), resin-modified glass ionomer (RMGI) cement (RelyX Luting 2), and self-adhesive resin cement (RelyX U200). Shear bond strength was measured using a universal testing machine, and failure modes were analyzed using scanning electron microscopy. The combination of Rocatec treatment and self-adhesive resin cement exhibited the highest bond strength. Self-adhesive resin cement demonstrated significantly higher bond strength than the other cements under all surface conditions (p < 0.017). Within the self-adhesive resin and RMGI cement groups, shear bond strength varied significantly by surface treatment (p < 0.017), while no significant difference was found in GI cement group (p > 0.017). Adhesive failures occurred only in untreated groups, whereas cohesive and mixed failures appeared exclusively in surface-treated groups. Within the limitations of this in vitro study, Rocatec treatment with self-adhesive resin cement was the most effective bonding strategy for submicron polycrystalline alumina ceramics.
- 30 November 2025
- Published by Korean Academy of Pediatric Dentistry in THE JOURNAL OF THE KOREAN ACADEMY OF PEDTATRIC DENTISTRY
- Vol. 52 (4) , 425-436
Open AccessEvaluation of Shear Bond Strength of Submicron Polycrystalline Alumina Ceramic with Different Surface Treatments and Luting Cements
Submicron polycrystalline alumina ceramic offers excellent mechanical strength and translucency, making it a promising material for pediatric crown restorations. However, due to its acid resistance and low surface energy, reliable bonding requires appropriate surface treatments and selection of compatible cement materials. This study aimed to evaluate the shear bond strength of submicron polycrystalline alumina ceramics subjected to various surface treatments and bonded with different types of luting cements. Ninety specimens were divided into three surface treatment groups: no treatment, sandblasting, and Rocatec treatment. Each group was further subdivided by cement type: glass ionomer (GI) cement (GC Fuji I), resin-modified glass ionomer (RMGI) cement (RelyX Luting 2), and self-adhesive resin cement (RelyX U200). Shear bond strength was measured using a universal testing machine, and failure modes were analyzed using scanning electron microscopy. The combination of Rocatec treatment and self-adhesive resin cement exhibited the highest bond strength. Self-adhesive resin cement demonstrated significantly higher bond strength than the other cements under all surface conditions (p < 0.017). Within the self-adhesive resin and RMGI cement groups, shear bond strength varied significantly by surface treatment (p < 0.017), while no significant difference was found in GI cement group (p > 0.017). Adhesive failures occurred only in untreated groups, whereas cohesive and mixed failures appeared exclusively in surface-treated groups. Within the limitations of this in vitro study, Rocatec treatment with self-adhesive resin cement was the most effective bonding strategy for submicron polycrystalline alumina ceramics.
- Open Access
- 30 September 2025
- Published by Korean Academy of Preventive Dentistry in International Journal of Clinical Preventive Dentistry
- Vol. 21 (3) , 78-85
Real-Time Water Quality Monitoring in Dental Units: Temporal Trends in Turbidity as a Rapid Indicator
Yerim Song, Jongbin Kim, Jongsoo Kim, Joonhaeng Lee, Miran Han, Jisun Shin. IJCPD 2025;21:78-85. https://doi.org/10.15236/ijcpd.2025.21.3.78
- 30 September 2025
- Published by Korean Academy of Preventive Dentistry in International Journal of Clinical Preventive Dentistry
- Vol. 21 (3) , 78-85
Open AccessReal-Time Water Quality Monitoring in Dental Units: Temporal Trends in Turbidity as a Rapid Indicator
Yerim Song, Jongbin Kim, Jongsoo Kim, Joonhaeng Lee, Miran Han, Jisun Shin. IJCPD 2025;21:78-85. https://doi.org/10.15236/ijcpd.2025.21.3.78
- Open Access
- 31 August 2025
- Published by Korean Academy of Pediatric Dentistry in THE JOURNAL OF THE KOREAN ACADEMY OF PEDTATRIC DENTISTRY
- Vol. 52 (3) , 302-311
Effect of Laser Surface Texturing Using a Surface Transition Machine on Bonding Strength to Zirconia Ceramic
The purpose of this study was to evaluate the effect of zirconia surface treatment using laser surface texturing performed with a Surface Transition Machine (STM). Zirconia specimens were fabricated in two shapes: 40 cylindrical specimens and square specimens. These were divided into two groups: the sandblasting group and the STM treatment group. Each group was bonded with either resin cement (Duo-Link) or resin-modified glass ionomer (RMGI) cement (RelyX Luting 2) after Z-Prime Plus primer application. The shear bond strength was measured using a universal testing machine, and the surface characteristics were analyzed using scanning electron microscopy and high-performance 3D digital microscopy. The group bonded with resin cement after STM treatment (48.4 ± 10.4 MPa) exhibited the highest shear bond strength, whereas the group bonded with RMGI cement after sandblasting (8.1 ± 1.5 MPa) exhibited the lowest. The STM treatment group showed significantly higher shear bond strength than the sandblasted group, and the Duo-Link group demonstrated significantly higher bond strength than the RelyX Luting 2 group. Surface observations showed that the STM treatment group exhibited rough surfaces and regularly patterned retentive structures. The surface roughness (Sa) was also significantly higher in the STM treatment group (13.3 ± 1.5 μm) than in the sandblasting group (7.08 ± 0.4 μm). In conclusion, STM treatment effectively improved the shear bond strength between zirconia and cement, particularly providing the highest bond strength when used with resin cement.
- 31 August 2025
- Published by Korean Academy of Pediatric Dentistry in THE JOURNAL OF THE KOREAN ACADEMY OF PEDTATRIC DENTISTRY
- Vol. 52 (3) , 302-311
Open AccessEffect of Laser Surface Texturing Using a Surface Transition Machine on Bonding Strength to Zirconia Ceramic
The purpose of this study was to evaluate the effect of zirconia surface treatment using laser surface texturing performed with a Surface Transition Machine (STM). Zirconia specimens were fabricated in two shapes: 40 cylindrical specimens and square specimens. These were divided into two groups: the sandblasting group and the STM treatment group. Each group was bonded with either resin cement (Duo-Link) or resin-modified glass ionomer (RMGI) cement (RelyX Luting 2) after Z-Prime Plus primer application. The shear bond strength was measured using a universal testing machine, and the surface characteristics were analyzed using scanning electron microscopy and high-performance 3D digital microscopy. The group bonded with resin cement after STM treatment (48.4 ± 10.4 MPa) exhibited the highest shear bond strength, whereas the group bonded with RMGI cement after sandblasting (8.1 ± 1.5 MPa) exhibited the lowest. The STM treatment group showed significantly higher shear bond strength than the sandblasted group, and the Duo-Link group demonstrated significantly higher bond strength than the RelyX Luting 2 group. Surface observations showed that the STM treatment group exhibited rough surfaces and regularly patterned retentive structures. The surface roughness (Sa) was also significantly higher in the STM treatment group (13.3 ± 1.5 μm) than in the sandblasting group (7.08 ± 0.4 μm). In conclusion, STM treatment effectively improved the shear bond strength between zirconia and cement, particularly providing the highest bond strength when used with resin cement.
- Open Access
- 31 August 2025
- Published by Korean Academy of Pediatric Dentistry in THE JOURNAL OF THE KOREAN ACADEMY OF PEDTATRIC DENTISTRY
- Vol. 52 (3) , 374-384
Evaluation of the Bonding Performance of a New Universal Adhesive to Artificially Created Caries-Affected Dentin
This study aimed to evaluate the bonding performance of a newly developed universal adhesive, Scotchbond Universal Plus, to artificially created caries-affected dentin compared to sound dentin. Bovine teeth were used to prepare specimens with either sound dentin or caries-affected dentin, which was induced by 14 cycles of alternating demineralization and remineralization using a pH-cycling model. Forty specimens were randomly divided into four groups according to the dentin substrate condition and the type of adhesive used. The adhesives were applied according to the manufacturer’s instructions, followed by composite resin restoration. Shear bond strength was measured using a universal testing machine, and the resindentin interface was analyzed by scanning electron microscopy. The mean shear bond strength of Scotchbond Universal Plus was 37.32 ± 3.28 MPa on sound dentin and 31.21 ± 2.97 MPa on caries-affected dentin, while that of Single Bond Universal was 36.63 ± 3.93 MPa and 25.32 ± 4.67 MPa, respectively. There was no significant difference between the two adhesives on sound dentin (p = 0.621), but Scotchbond Universal Plus exhibited significantly higher bond strength than Single Bond Universal on caries-affected dentin (p = 0.008). Scanning electron microscopy and quantitative analysis revealed that Scotchbond Universal Plus produced longer and more abundant resin tags and a thinner adhesive layer compared to Single Bond Universal in caries-affected dentin. These outcomes may be attributed to the lower viscosity of the new adhesive, which facilitated improved infiltration. Within the limitations of this in vitro study, the new universal adhesive demonstrated enhanced bonding performance to caries-affected dentin and may offer clinical advantages for restorative procedures involving demineralized dentin. Further clinical investigations are necessary to validate its long-term effectiveness under natural caries conditions.
- 31 August 2025
- Published by Korean Academy of Pediatric Dentistry in THE JOURNAL OF THE KOREAN ACADEMY OF PEDTATRIC DENTISTRY
- Vol. 52 (3) , 374-384
Open AccessEvaluation of the Bonding Performance of a New Universal Adhesive to Artificially Created Caries-Affected Dentin
This study aimed to evaluate the bonding performance of a newly developed universal adhesive, Scotchbond Universal Plus, to artificially created caries-affected dentin compared to sound dentin. Bovine teeth were used to prepare specimens with either sound dentin or caries-affected dentin, which was induced by 14 cycles of alternating demineralization and remineralization using a pH-cycling model. Forty specimens were randomly divided into four groups according to the dentin substrate condition and the type of adhesive used. The adhesives were applied according to the manufacturer’s instructions, followed by composite resin restoration. Shear bond strength was measured using a universal testing machine, and the resindentin interface was analyzed by scanning electron microscopy. The mean shear bond strength of Scotchbond Universal Plus was 37.32 ± 3.28 MPa on sound dentin and 31.21 ± 2.97 MPa on caries-affected dentin, while that of Single Bond Universal was 36.63 ± 3.93 MPa and 25.32 ± 4.67 MPa, respectively. There was no significant difference between the two adhesives on sound dentin (p = 0.621), but Scotchbond Universal Plus exhibited significantly higher bond strength than Single Bond Universal on caries-affected dentin (p = 0.008). Scanning electron microscopy and quantitative analysis revealed that Scotchbond Universal Plus produced longer and more abundant resin tags and a thinner adhesive layer compared to Single Bond Universal in caries-affected dentin. These outcomes may be attributed to the lower viscosity of the new adhesive, which facilitated improved infiltration. Within the limitations of this in vitro study, the new universal adhesive demonstrated enhanced bonding performance to caries-affected dentin and may offer clinical advantages for restorative procedures involving demineralized dentin. Further clinical investigations are necessary to validate its long-term effectiveness under natural caries conditions.
- Open Access
- 31 August 2025
- Published by Korean Academy of Pediatric Dentistry in THE JOURNAL OF THE KOREAN ACADEMY OF PEDTATRIC DENTISTRY
- Vol. 52 (3) , 312-321
Translucency and Masking Ability of Single-Shade Opaque Composite Resin Compared with Conventional Opaque Composite Resins According to Thickness
This study aimed to evaluate and compare the translucency and masking ability of a single-shade opaque composite resin with those of conventional opaque-shade composite resins of varying thicknesses. Three types of composite resin specimens, Omnichroma Blocker, Filtek Z350 XT A2D, and Gradia Direct Anterior AO2, were fabricated with a diameter of 8.0 mm and thicknesses of 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, and 4.0 mm. Three background plates were tested: a white tile, a black tile, and a C4-shade porcelain plate. The CIE L*a*b* values of the resin specimens on each background and in their inherent color were measured using a spectrophotometer, and the translucency parameter (TP) and color difference (ΔE*ab) were calculated. In all groups, TP and ΔE*ab values decreased with increasing specimen thickness. The black background was masked at a thickness of 1.5 mm or more, while the C4-shade porcelain background was masked at all tested thicknesses. Within the limitations of this study, a minimum thickness of 1.5 mm is recommended to mask intraoral darkness, and a thickness of 0.5 mm or greater is recommended to mask stained or discolored tooth structures.
- 31 August 2025
- Published by Korean Academy of Pediatric Dentistry in THE JOURNAL OF THE KOREAN ACADEMY OF PEDTATRIC DENTISTRY
- Vol. 52 (3) , 312-321
Open AccessTranslucency and Masking Ability of Single-Shade Opaque Composite Resin Compared with Conventional Opaque Composite Resins According to Thickness
This study aimed to evaluate and compare the translucency and masking ability of a single-shade opaque composite resin with those of conventional opaque-shade composite resins of varying thicknesses. Three types of composite resin specimens, Omnichroma Blocker, Filtek Z350 XT A2D, and Gradia Direct Anterior AO2, were fabricated with a diameter of 8.0 mm and thicknesses of 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, and 4.0 mm. Three background plates were tested: a white tile, a black tile, and a C4-shade porcelain plate. The CIE L*a*b* values of the resin specimens on each background and in their inherent color were measured using a spectrophotometer, and the translucency parameter (TP) and color difference (ΔE*ab) were calculated. In all groups, TP and ΔE*ab values decreased with increasing specimen thickness. The black background was masked at a thickness of 1.5 mm or more, while the C4-shade porcelain background was masked at all tested thicknesses. Within the limitations of this study, a minimum thickness of 1.5 mm is recommended to mask intraoral darkness, and a thickness of 0.5 mm or greater is recommended to mask stained or discolored tooth structures.
- Open Access
- 30 June 2025
- Published by Korean Academy of Preventive Dentistry in International Journal of Clinical Preventive Dentistry
- Vol. 21 (2) , 31-37
Comparison of Laser Fluorescence Devices’ Diagnostic Validity in Occlusal Caries of Primary Teeth
YongWoo Choi, Seolhee Jeong, Jongbin Kim, Mi Ran Han, Jisun Shin, Joonhaeng Lee, JongSoo Kim. IJCPD 2025;21:31-7. https://doi.org/10.15236/ijcpd.2025.21.2.31
- 30 June 2025
- Published by Korean Academy of Preventive Dentistry in International Journal of Clinical Preventive Dentistry
- Vol. 21 (2) , 31-37
Open AccessComparison of Laser Fluorescence Devices’ Diagnostic Validity in Occlusal Caries of Primary Teeth
YongWoo Choi, Seolhee Jeong, Jongbin Kim, Mi Ran Han, Jisun Shin, Joonhaeng Lee, JongSoo Kim. IJCPD 2025;21:31-7. https://doi.org/10.15236/ijcpd.2025.21.2.31