NBNicholas K. Brown

Nicholas K. Brown

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Nicholas K. Brown has a total of 19 co-authors. Here are the top co-authors by number of shared publications:

  • Amanda Hauck

    Department of Pediatrics, Northwestern University Feinberg School of Medicine, Lurie Children’s Hospital, Chicago, IL 60611, USA

    2 shared publications
  • Cynthia K. Rigsby

    Department of Medical Imaging, Ann & Robert H Lurie Children’s Hospital of Chicago, Chicago, USA

    2 shared publications
  • Joshua D. Robinson

    Ann & Robert H. Lurie Children's Hospital of Chicago, Chicago, IL, USA

    2 shared publications
  • Nazia Husain

    Division of Cardiology, Department of Pediatrics Ann & Robert H. Lurie Children's Hospital of Chicago, Northwestern University Feinberg School of Medicine Chicago Illinois USA

    2 shared publications
  • Pei-Ni Jone

    Department of Pediatrics, Pediatric Cardiology, Ann & Robert Lurie Children’s Hospital of Chicago, Northwestern University Feinberg School of Medicine, IL (P.-N.J.).

    2 shared publications
  • Sandhya R. Ramlogan

    Division of Cardiology, Department of Pediatrics, Ann & Robert H. Lurie Children’s Hospital of Chicago, Northwestern University Feinberg School of Medicine, Chicago, USA

    2 shared publications

Latest Publications

  • Going with the flow: Implementing a 4D flow MRI program at a children’s hospital

    by Aparna Sodhi, Nicholas K. Brown, Joshua D. Robinson, Andrada R. Popescu, Michael Markl, Cynthia K. Rigsby

    Four-dimensional phase contrast MRI (4D flow) has emerged as a versatile imaging technique for comprehensive visualization and both qualitative and quantitative assessment of cardiovascular blood flow. 4D flow is a three-dimensional, time-resolved acquisition that is gated to the cardiac cycle. 4D flow provides cardiovascular velocity and flow assessment across the volume of acquisition and yields a multitude of advanced hemodynamic parameters that help to assess the impact of cardiovascular disease on flow and vice versa, guiding the clinical and surgical management of patients with congenital and acquired heart disease. In the past, lengthy scan acquisition and complex post-processing workflows hindered 4D flow adoption into routine clinical practice. Decreasing image acquisition times and improvements in post-processing techniques have made 4D flow a clinically useful tool. The purpose of this communication is to facilitate more widespread adoption of 4D flow by describing its clinical utility, technical acquisition, optimization, and post-processing in pediatric cardiovascular imaging at our center. Graphical abstract


  • Pediatric Echocardiography

    by Nicholas K. Brown, Pei-Ni Jone, Shivani Patel, Amanda L. Hauck

  • Echocardiography

    by Nicholas K. Brown, Pei-Ni Jone, Shivani Patel, Amanda L. Hauck

  • Right Ventricular Remodeling Assessed by MRI in Duchenne Muscular Dystrophy

    by Nicholas K. Brown, Haben Berhane, Katheryn Gambetta, Michael Markl, Cynthia K. Rigsby, Joshua D. Robinson, Nazia Husain

    Background: In Duchenne muscular dystrophy (DMD), the right ventricle (RV) tends to be relatively well preserved, but characterization remains difficult due to its complex architecture. Tissue phase mapping (TPM) is a phase contrast cine MRI technique that allows for multidirectional assessment of myocardial velocities.Purpose: To use TPM to elucidate relationships between myocardial structure, function, and clinical variables in DMD.Study Type: Retrospective.Subjects: A total of 20 patients with muscular dystrophy (median age: 16 years); 18 age‐matched normal controls (median age: 15 years).Field Strength/Sequence: Three‐directional velocity encoded cine gradient echo sequence (TPM) at 1.5 T, balanced steady‐state free procession (bSSFP), T1 mapping with extracellular volume (ECV), and late gadolinium enhancement (LGE).Assessment: TPM in basal, mid, and apical short‐axis planes was performed as part of a standard MRI study with collection of clinical data. Radial, circumferential, and longitudinal velocities (Vr, Vφ, and Vz, respectively) and corresponding time to peak (TTP) velocities were quantified from TPM and used to calculate RV twist as well as intraventricular and interventricular dyssynchrony. The correlations between TPM velocities, myocardial structure/function, and clinical variables were assessed.Statistical Test: Unpaired t‐test, Wilcoxon rank‐sum test, Bland–Altman analyses were used for comparisons between DMD patients and controls and between DMD subgroups. Pearson's test was used for correlations (r). Significance level: P < 0.05.Results: Compared to controls, DMD patients had preserved RV ejection fraction (RVEF 53% ± 8%) but significantly increased interventricular dyssynchrony (Vφ: 0.49 ± 0.21 vs. 0.72 ± 0.17). Within the DMD cohort, RV dyssynchrony significantly increased with lower LV ejection fraction (intraventricular Vr and Vz: r = −0.49; interventricular Vz: r = 0.48). In addition, RV intraventricular dyssynchrony significantly increased with older age (Vz: r = 0.67).Data Conclusion: RV remodeling in DMD occurs in the context of preserved RVEF. Within DMD, this abnormal RV deformation is associated with older age and decreased LVEF.Evidence Level: 4.Technical Efficacy: Stage 2.


  • Open Access

    Combined Echo and Fluoroscopy-Guided Pulmonary Valvuloplasty in Neonates and Infants: Efficacy and Safety

    by Nicholas K. Brown, Nazia Husain, Jennifer Arzu, Sandhya R. Ramlogan, Alan W. Nugent, Paul Tannous

    Percutaneous balloon pulmonary valvuloplasty (PBPV) is the treatment of choice for isolated pulmonary valve stenosis. While this procedure is highly efficacious and has an excellent safety profile, as currently practiced, patients are obligatorily exposed to the secondary risks of ionizing radiation and contrast media. To mitigate these risks, we developed a protocol which utilized echo guidance for portions of the procedure which typically require fluoroscopy and/or angiography. Ten cases of echo-guided pulmonary valvuloplasty (EG-PBPV) for isolated pulmonary stenosis in children less than a year of age were compared to a historical cohort of nineteen standard cases using fluoroscopy/angiography alone, which demonstrated equivalent procedural outcomes and safety, while achieving a median reduction in radiation (total dose area product) and contrast load of 80% and 84%, respectively. Our early experience demonstrates that EG-PBPV in neonates and infants has results equivalent to standard valvuloplasty but with less radiation and contrast.