Sachio Kuribayashi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sachio Kuribayashi has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Masahiro Jinzaki
Department of Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan
3 shared publications - Shigeo Okuda
Department of Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan
3 shared publications - Akio Kawamura
Association of Cardiac Rehabilitation (JACR
2 shared publications Masahiro Jinzaki
Department of Radiology, Keio University Hospital
2 shared publications- Minoru Yamada
Department of Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan
2 shared publications - Yoshitake Yamada
Department of Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan
2 shared publications
Latest Publications
- 1 May 2022
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
- Vol. 16 (3) , 239-244
Accuracy of ultra-high–resolution computed tomography with a 0.3-mm detector for quantitative assessment of coronary artery stenosis grading in comparison with conventional computed tomography: A phantom study
- 1 May 2022
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
- Vol. 16 (3) , 239-244
Accuracy of ultra-high–resolution computed tomography with a 0.3-mm detector for quantitative assessment of coronary artery stenosis grading in comparison with conventional computed tomography: A phantom study
- 30 April 2015
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 33 (7) , 911-917
Three-dimensional cardiac cine imaging using the kat ARC acceleration: Initial experience in clinical adult patients at 3T
- 30 April 2015
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 33 (7) , 911-917
Three-dimensional cardiac cine imaging using the kat ARC acceleration: Initial experience in clinical adult patients at 3T
- Open Access
- 1 January 2015
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 79 (2) , 406-412
Non-Invasive Computed Fractional Flow Reserve From Computed Tomography (CT) for Diagnosing Coronary Artery Disease
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- 1 January 2015
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 79 (2) , 406-412
Open AccessNon-Invasive Computed Fractional Flow Reserve From Computed Tomography (CT) for Diagnosing Coronary Artery Disease
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- Open Access
- 1 January 2013
- Published by Japanese Society for Magnetic Resonance in Medicine in Magnetic Resonance in Medical Sciences
- Vol. 12 (4) , 271-280
What is the Most Effective Tool for Detecting Prostate Cancer using a Standard MR Scanner?
Purpose: We aimed to determine which of the following magnetic resonance (MR) imaging sequences is most effective for detecting prostate cancer: T2-weighted (T2W), dynamic contrast-enhanced (DCE) T1-weighted (T1W), or diffusion-weighted (DWI) imaging or apparent diffusion coefficient (ADC) mapping. Materials and Methods: We included 37 male patients with prostate cancer who underwent MR imaging before radical prostatectomy in this retrospective study. Sixty-four foci (>5 mm in size; 35 in the peripheral zone [PZ], 29 in the transitional zone [TZ]) were histopathologically determined to be prostate cancer. We determined the capacity of T2W, DCE-T1W, DWI, ADC mapping alone, and the combination of ADC mapping with DWI, and conventional MR sequences to detect prostate cancer, including their sensitivity and positive predictive value (PPV), with reference to the results obtained in histopathological examinations of whole-mount sections. Results: In the PZ, sensitivities were 31.4% (T2W), 37.1% (DCE-T1W), 51.4% (DWI), and 71.4% (ADC mapping); PPVs were 78.6% (T2W), 92.9% (DCE-T1W), 94.7% (DWI), and 96.0% (ADC mapping). Sensitivity was significantly higher of ADC mapping than other sequences. In the TZ, sensitivities were 55.1% (T2W), 44.8% (DCE-T1W), 82.8% (DWI), and 89.7% (ADC mapping); PPVs were 64.0% (T2W), 46.4% (DCE-T1W), 70.6% (DWI), and 72.2% (ADC mapping). Sensitivity was significantly higher of ADC mapping and DWI than conventional MR imaging, but there was no significant correlation between DWI/ADC mapping and T2W/DCE-T1W with respect to PPVs. Combining sequences did not improve sensitivity; only the PPV in the TZ improved when ADC mapping was combined with DCE-T1W. Conclusion: ADC mapping is the most effective standard MR imaging tool for detecting prostate cancer. The addition of DCE-T1W may improve the PPV of ADC mapping for diagnosing cancer in the TZ.
- 1 January 2013
- Published by Japanese Society for Magnetic Resonance in Medicine in Magnetic Resonance in Medical Sciences
- Vol. 12 (4) , 271-280
Open AccessWhat is the Most Effective Tool for Detecting Prostate Cancer using a Standard MR Scanner?
Purpose: We aimed to determine which of the following magnetic resonance (MR) imaging sequences is most effective for detecting prostate cancer: T2-weighted (T2W), dynamic contrast-enhanced (DCE) T1-weighted (T1W), or diffusion-weighted (DWI) imaging or apparent diffusion coefficient (ADC) mapping. Materials and Methods: We included 37 male patients with prostate cancer who underwent MR imaging before radical prostatectomy in this retrospective study. Sixty-four foci (>5 mm in size; 35 in the peripheral zone [PZ], 29 in the transitional zone [TZ]) were histopathologically determined to be prostate cancer. We determined the capacity of T2W, DCE-T1W, DWI, ADC mapping alone, and the combination of ADC mapping with DWI, and conventional MR sequences to detect prostate cancer, including their sensitivity and positive predictive value (PPV), with reference to the results obtained in histopathological examinations of whole-mount sections. Results: In the PZ, sensitivities were 31.4% (T2W), 37.1% (DCE-T1W), 51.4% (DWI), and 71.4% (ADC mapping); PPVs were 78.6% (T2W), 92.9% (DCE-T1W), 94.7% (DWI), and 96.0% (ADC mapping). Sensitivity was significantly higher of ADC mapping than other sequences. In the TZ, sensitivities were 55.1% (T2W), 44.8% (DCE-T1W), 82.8% (DWI), and 89.7% (ADC mapping); PPVs were 64.0% (T2W), 46.4% (DCE-T1W), 70.6% (DWI), and 72.2% (ADC mapping). Sensitivity was significantly higher of ADC mapping and DWI than conventional MR imaging, but there was no significant correlation between DWI/ADC mapping and T2W/DCE-T1W with respect to PPVs. Combining sequences did not improve sensitivity; only the PPV in the TZ improved when ADC mapping was combined with DCE-T1W. Conclusion: ADC mapping is the most effective standard MR imaging tool for detecting prostate cancer. The addition of DCE-T1W may improve the PPV of ADC mapping for diagnosing cancer in the TZ.
- 1 November 2011
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 54 (5) , 1488-1491
Successful endovascular treatment of hemosuccus pancreaticus due to splenic artery aneurysm associated with segmental arterial mediolysis
- 1 November 2011
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 54 (5) , 1488-1491
Successful endovascular treatment of hemosuccus pancreaticus due to splenic artery aneurysm associated with segmental arterial mediolysis
- Open Access
- 1 January 2009
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 73 (4) , 691-698
Diagnostic Accuracy of Angiographic View Image for the Detection of Coronary Artery Stenoses by 64-Detector Row CT A Pilot Study Comparison With Conventional Post-Processing Methods and Axial Images Alone
The angiographic view (AGV) image is a new post-processing method that is similar to conventional coronary angiography (CAG). The purpose of this study was to evaluate its accuracy for coronary stenosis detection by 64-detector row computed tomography (CT). CT evaluation results of 17 patients were compared with the results of invasive CAG on a coronary segment basis concerning the presence of stenoses>50% diameter reduction. All images of the 3 viewing methods (combination of conventional methods, AGV image alone, and axial images alone) were evaluated in consensus by 3 cardiovascular radiologists. Among 196 assessable segments, invasive CAG showed significant coronary artery stenoses in 44 segments. 43 of 44 lesions were detected with the AGV image, and absence of significant stenosis was correctly identified in 135 of 152 segments (sensitivity 98%; specificity 89%; accuracy 91%; positive predictive value 72%, negative predictive value 99%). The sensitivity of the AGV image was the same as that of conventional methods (98%). There was no significant difference in accuracy between the AGV image (91%) and conventional methods (94%). The accuracy of the AGV image was significantly higher than the axial images alone (78%). AGV image shows promise as a post-processing method for identifying coronary artery stenosis with high accuracy.
- 1 January 2009
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 73 (4) , 691-698
Open AccessDiagnostic Accuracy of Angiographic View Image for the Detection of Coronary Artery Stenoses by 64-Detector Row CT A Pilot Study Comparison With Conventional Post-Processing Methods and Axial Images Alone
The angiographic view (AGV) image is a new post-processing method that is similar to conventional coronary angiography (CAG). The purpose of this study was to evaluate its accuracy for coronary stenosis detection by 64-detector row computed tomography (CT). CT evaluation results of 17 patients were compared with the results of invasive CAG on a coronary segment basis concerning the presence of stenoses>50% diameter reduction. All images of the 3 viewing methods (combination of conventional methods, AGV image alone, and axial images alone) were evaluated in consensus by 3 cardiovascular radiologists. Among 196 assessable segments, invasive CAG showed significant coronary artery stenoses in 44 segments. 43 of 44 lesions were detected with the AGV image, and absence of significant stenosis was correctly identified in 135 of 152 segments (sensitivity 98%; specificity 89%; accuracy 91%; positive predictive value 72%, negative predictive value 99%). The sensitivity of the AGV image was the same as that of conventional methods (98%). There was no significant difference in accuracy between the AGV image (91%) and conventional methods (94%). The accuracy of the AGV image was significantly higher than the axial images alone (78%). AGV image shows promise as a post-processing method for identifying coronary artery stenosis with high accuracy.
- Open Access
- 1 January 2005
- Published by Japanese Society of Radiological Technology in Japanese Journal of Radiological Technology
- Vol. 61 (4) , 506-513
Improving Coronary Artery Imaging Quality in the High Heart Rate Region and on MDCT Using a Pulsating Cardiac Phantom
The multi-sector reconstruction (MSR) algorithm and cardiac half-reconstruction (CHR) algorithm are the main algorithms used in cardiac reconstruction. Analysis of effective temporal resolution (TR) confirmed that optimal rotation speed depends on different heart rates when using MSR. During visualization (3D/MPR image) and quantitative (EF : ejection fraction) evaluations, it was found that image quality and measurement accuracy are well correlated with effective temporal resolution (TR) by the different algorithms. The CHR algorithm resulted in less desirable image quality at TR 250 ms than that from MSR at high heart rates (>75 bpm) in the phantom experiment. We determined that the combination of the MSR algorithm and the optimal selection of gantry rotation speed is important for obtaining high-quality cardiac imaging in the high heart rate region.
- 1 January 2005
- Published by Japanese Society of Radiological Technology in Japanese Journal of Radiological Technology
- Vol. 61 (4) , 506-513
Open AccessImproving Coronary Artery Imaging Quality in the High Heart Rate Region and on MDCT Using a Pulsating Cardiac Phantom
The multi-sector reconstruction (MSR) algorithm and cardiac half-reconstruction (CHR) algorithm are the main algorithms used in cardiac reconstruction. Analysis of effective temporal resolution (TR) confirmed that optimal rotation speed depends on different heart rates when using MSR. During visualization (3D/MPR image) and quantitative (EF : ejection fraction) evaluations, it was found that image quality and measurement accuracy are well correlated with effective temporal resolution (TR) by the different algorithms. The CHR algorithm resulted in less desirable image quality at TR 250 ms than that from MSR at high heart rates (>75 bpm) in the phantom experiment. We determined that the combination of the MSR algorithm and the optimal selection of gantry rotation speed is important for obtaining high-quality cardiac imaging in the high heart rate region.
- Open Access
- 1 January 2005
- Published by Japanese Society for Magnetic Resonance in Medicine in Magnetic Resonance in Medical Sciences
- Vol. 4 (2) , 53-60
Hepatocyte-Targeted MR Contrast Agents: Contrast Enhanced Detection of Liver Cancer in Diffusely Damaged Liver
The performance of hepatocyte-targeted magnetic resonance (MR) contrast agents in the detection of liver tumor was tested in rats with hepatitis. Hepatocyte-targeted MR contrast agents (paramagnetic hepatobiliary complex [manganese-DPDP] and superparamagnetic iron oxide coated with arabinogalactan [SPIO-AG]) were injected into normal rats and rats with carbon tetrachloride-induced hepatitis. Before and after injection of either contrast agent, ex vivo relaxometry (0.94T) or in vivo MR imaging (1.0T) were performed. The obtained liver and tumor T1 and T2 relaxation times, liver and tumor signal-to-noise ratios (SNR), and tumor-liver contrast-to-noise ratios (CNR) of control rats and rats with hepatitis were compared. Both relaxometry and MR imaging showed that MnDPDP and SPIO-AG selectively enhanced liver tissue in controls and in rats with hepatitis to the same degree, and little tumor enhancement was seen in either group. As a result, no significant difference between control rats and rats with hepatitis was observed in the postcontrast tumor-liver CNR. For a MnDPDP-enhanced CNR with spin echo (SE) of 310/15, the results were -10.4±3.6 in control rats vs. -11.5±1.4 in rats with hepatitis; for a SPIO-AG-enhanced CNR with SE 2000/45 and 2000/90, respectively, the results were 30.7±9.2 and 18.7±4.7 in control rats vs. 31.9±7.1 and 17.7±2.4 in rats with hepatitis. These results indicate that hepatocyte-targeted contrast agents effectively enhance liver tissue and enhance liver-tumor image contrast despite hepatocellular dysfunction.
- 1 January 2005
- Published by Japanese Society for Magnetic Resonance in Medicine in Magnetic Resonance in Medical Sciences
- Vol. 4 (2) , 53-60
Open AccessHepatocyte-Targeted MR Contrast Agents: Contrast Enhanced Detection of Liver Cancer in Diffusely Damaged Liver
The performance of hepatocyte-targeted magnetic resonance (MR) contrast agents in the detection of liver tumor was tested in rats with hepatitis. Hepatocyte-targeted MR contrast agents (paramagnetic hepatobiliary complex [manganese-DPDP] and superparamagnetic iron oxide coated with arabinogalactan [SPIO-AG]) were injected into normal rats and rats with carbon tetrachloride-induced hepatitis. Before and after injection of either contrast agent, ex vivo relaxometry (0.94T) or in vivo MR imaging (1.0T) were performed. The obtained liver and tumor T1 and T2 relaxation times, liver and tumor signal-to-noise ratios (SNR), and tumor-liver contrast-to-noise ratios (CNR) of control rats and rats with hepatitis were compared. Both relaxometry and MR imaging showed that MnDPDP and SPIO-AG selectively enhanced liver tissue in controls and in rats with hepatitis to the same degree, and little tumor enhancement was seen in either group. As a result, no significant difference between control rats and rats with hepatitis was observed in the postcontrast tumor-liver CNR. For a MnDPDP-enhanced CNR with spin echo (SE) of 310/15, the results were -10.4±3.6 in control rats vs. -11.5±1.4 in rats with hepatitis; for a SPIO-AG-enhanced CNR with SE 2000/45 and 2000/90, respectively, the results were 30.7±9.2 and 18.7±4.7 in control rats vs. 31.9±7.1 and 17.7±2.4 in rats with hepatitis. These results indicate that hepatocyte-targeted contrast agents effectively enhance liver tissue and enhance liver-tumor image contrast despite hepatocellular dysfunction.
- Open Access
- 1 January 2004
- Published by Japanese Society for Magnetic Resonance in Medicine in Magnetic Resonance in Medical Sciences
- Vol. 3 (2) , 95-100
Accuracy of MR Temperature Measurement Based on Chemical Shift Change for Radiofrequency Ablation Using Hook-shaped Electrodes
The purpose of the current study is to evaluate the accuracy of MR thermometry for radiofrequency ablation (RFA) with hook-shaped electrodes. The objects were eight extracted bovine livers. The chemical shift change was calculated from MR images acquired with a spoiled gradient echo sequence and compared with the temperature directly measured with a thermocouple. Linear regression was established between them with a coefficient of -0.0110±0.0007 ppm/°C and errors were calculated as -0.50±7.50°C. MR thermometry is capable of monitoring temperature for RFA.
- 1 January 2004
- Published by Japanese Society for Magnetic Resonance in Medicine in Magnetic Resonance in Medical Sciences
- Vol. 3 (2) , 95-100
Open AccessAccuracy of MR Temperature Measurement Based on Chemical Shift Change for Radiofrequency Ablation Using Hook-shaped Electrodes
The purpose of the current study is to evaluate the accuracy of MR thermometry for radiofrequency ablation (RFA) with hook-shaped electrodes. The objects were eight extracted bovine livers. The chemical shift change was calculated from MR images acquired with a spoiled gradient echo sequence and compared with the temperature directly measured with a thermocouple. Linear regression was established between them with a coefficient of -0.0110±0.0007 ppm/°C and errors were calculated as -0.50±7.50°C. MR thermometry is capable of monitoring temperature for RFA.